{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,6]],"date-time":"2025-02-06T05:27:40Z","timestamp":1738819660953,"version":"3.37.0"},"reference-count":10,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T00:00:00Z","timestamp":1738368000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T00:00:00Z","timestamp":1738368000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,12,17]],"date-time":"2024-12-17T00:00:00Z","timestamp":1734393600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JACC: Case Reports"],"published-print":{"date-parts":[[2025,2]]},"DOI":"10.1016\/j.jaccas.2024.103128","type":"journal-article","created":{"date-parts":[[2025,2,5]],"date-time":"2025-02-05T18:35:52Z","timestamp":1738780552000},"page":"103128","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Use of a Bare Metal Dissection Stent to Manage Aortic Embolization of a Self-Expanding Valve"],"prefix":"10.1016","volume":"30","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9849-0965","authenticated-orcid":false,"given":"Matthew P.","family":"Huber","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oscar L.","family":"Maitas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David M.","family":"Elison","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sara L.","family":"Zettervall","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthew P.","family":"Sweet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James M.","family":"McCabe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Scott C.","family":"DeRoo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christine J.","family":"Chung","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"21","key":"10.1016\/j.jaccas.2024.103128_bib1","doi-asserted-by":"crossref","first-page":"1959","DOI":"10.1056\/NEJMoa2312573","article-title":"Self-expanding or balloon-expandable TAVR in patients with a small aortic annulus","volume":"390","author":"Herrmann","year":"2024","journal-title":"N\u00a0Engl J Med"},{"issue":"20","key":"10.1016\/j.jaccas.2024.103128_bib2","doi-asserted-by":"crossref","first-page":"2173","DOI":"10.1016\/j.jacc.2015.03.034","article-title":"Perioperative results and complications in 15,964 transcatheter aortic valve replacements: prospective data from the GARY registry","volume":"65","author":"Walther","year":"2015","journal-title":"J\u00a0Am Coll Cardiol"},{"issue":"15","key":"10.1016\/j.jaccas.2024.103128_bib3","doi-asserted-by":"crossref","first-page":"1589","DOI":"10.1016\/j.jcin.2016.05.015","article-title":"Acute and 30-day outcomes in women after TAVR: results from the WIN-TAVI (Women's INternational Transcatheter Aortic Valve Implantation) real-world registry","volume":"9","author":"Chieffo","year":"2016","journal-title":"JACC Cardiovasc Interv"},{"issue":"38","key":"10.1016\/j.jaccas.2024.103128_bib4","doi-asserted-by":"crossref","first-page":"3156","DOI":"10.1093\/eurheartj\/ehz429","article-title":"Incidence and outcome of peri-procedural transcatheter heart valve embolization and migration: the TRAVEL registry (TranscatheteR HeArt Valve EmboLization and Migration)","volume":"40","author":"Kim","year":"2019","journal-title":"Eur Heart J"},{"issue":"5","key":"10.1016\/j.jaccas.2024.103128_bib5","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1016\/j.jacc.2013.04.037","article-title":"Determinants and outcomes of acute transcatheter valve-in-valve therapy or embolization: a study of multiple valve implants in the U.S. PARTNER trial (Placement of AoRTic TraNscathetER Valve Trial Edwards SAPIEN Transcatheter Heart Valve)","volume":"62","author":"Makkar","year":"2013","journal-title":"J\u00a0Am Coll Cardiol"},{"issue":"2","key":"10.1016\/j.jaccas.2024.103128_bib6","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/j.jcin.2018.08.033","article-title":"Device embolization in structural heart interventions: incidence, outcomes, and retrieval techniques","volume":"12","author":"Alkhouli","year":"2019","journal-title":"JACC Cardiovasc Interv"},{"issue":"12","key":"10.1016\/j.jaccas.2024.103128_bib7","doi-asserted-by":"crossref","first-page":"e29","DOI":"10.2459\/JCM.0000000000001224","article-title":"Type A aortic dissection after transcatheter aortic valve replacement: is a surgical approach always needed?","volume":"22","author":"Santangelo","year":"2021","journal-title":"J\u00a0Cardiovasc Med (Hagerstown)"},{"issue":"7","key":"10.1016\/j.jaccas.2024.103128_bib8","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1080\/17434440.2019.1627198","article-title":"Device profile of the Zenith Dissection Endovascular System for aortic dissection","volume":"16","author":"Spanos","year":"2019","journal-title":"Expert Rev Med Devices"},{"key":"10.1016\/j.jaccas.2024.103128_bib9","author":"Cook"},{"key":"10.1016\/j.jaccas.2024.103128_bib10","article-title":"Innovative approach to manage transcatheter aortic valve embolization","volume":"7","author":"Keeton","year":"2023","journal-title":"JACC Case Rep"}],"container-title":["JACC: Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666084924011926?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666084924011926?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,2,5]],"date-time":"2025-02-05T18:35:56Z","timestamp":1738780556000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2666084924011926"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2]]},"references-count":10,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,2]]}},"alternative-id":["S2666084924011926"],"URL":"https:\/\/doi.org\/10.1016\/j.jaccas.2024.103128","relation":{},"ISSN":["2666-0849"],"issn-type":[{"value":"2666-0849","type":"print"}],"subject":[],"published":{"date-parts":[[2025,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Use of a Bare Metal Dissection Stent to Manage Aortic Embolization of a Self-Expanding Valve","name":"articletitle","label":"Article Title"},{"value":"JACC: Case Reports","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jaccas.2024.103128","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.","name":"copyright","label":"Copyright"}],"article-number":"103128"}}