{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,15]],"date-time":"2025-05-15T04:14:03Z","timestamp":1747282443240,"version":"3.40.5"},"reference-count":2,"publisher":"Elsevier BV","issue":"10","license":[{"start":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T00:00:00Z","timestamp":1746057600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T00:00:00Z","timestamp":1746057600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,4,14]],"date-time":"2025-04-14T00:00:00Z","timestamp":1744588800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JACC: Case Reports"],"published-print":{"date-parts":[[2025,5]]},"DOI":"10.1016\/j.jaccas.2025.104025","type":"journal-article","created":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T18:44:02Z","timestamp":1747248242000},"page":"104025","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Trans-Subclavian Artery Combined With\u00a0Artificial Graft Technique for Severe\u00a0Calcific Aortic Stenosis With Tortuous Anatomy"],"prefix":"10.1016","volume":"30","author":[{"given":"Feng","family":"Gao","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xijing","family":"Zhuang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xuezhi","family":"He","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yang","family":"Gao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenjun","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lei","family":"Shi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Weiwang","family":"Fan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lin","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"12","key":"10.1016\/j.jaccas.2025.104025_bib1","article-title":"Extracorporeal femoro-carotid shunt for transcarotid transcatheter aortic valve replacement","volume":"29","author":"Semco","year":"2024","journal-title":"JACC Case Rep"},{"key":"10.1016\/j.jaccas.2025.104025_bib2","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/j.xjtc.2023.07.019","article-title":"Transcarotid versus transaxillary access for transcatheter aortic valve replacement with a self-expanding valve: a propensity-matched analysis","volume":"21","author":"Allen","year":"2023","journal-title":"JTCVS Tech"}],"container-title":["JACC: Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S266608492500806X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S266608492500806X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T18:44:06Z","timestamp":1747248246000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S266608492500806X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5]]},"references-count":2,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2025,5]]}},"alternative-id":["S266608492500806X"],"URL":"https:\/\/doi.org\/10.1016\/j.jaccas.2025.104025","relation":{},"ISSN":["2666-0849"],"issn-type":[{"value":"2666-0849","type":"print"}],"subject":[],"published":{"date-parts":[[2025,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Trans-Subclavian Artery Combined With\u00a0Artificial Graft Technique for Severe\u00a0Calcific Aortic Stenosis With Tortuous Anatomy","name":"articletitle","label":"Article Title"},{"value":"JACC: Case Reports","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jaccas.2025.104025","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 Published by Elsevier on behalf of the American College of Cardiology Foundation.","name":"copyright","label":"Copyright"}],"article-number":"104025"}}