{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T20:44:28Z","timestamp":1782765868120,"version":"3.54.5"},"reference-count":9,"publisher":"Elsevier BV","issue":"25","license":[{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T00:00:00Z","timestamp":1776816000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jacc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JACC: Case Reports"],"published-print":{"date-parts":[[2026,6]]},"DOI":"10.1016\/j.jaccas.2026.108391","type":"journal-article","created":{"date-parts":[[2026,5,22]],"date-time":"2026-05-22T11:45:22Z","timestamp":1779450322000},"page":"108391","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Dedicated Transcatheter Valve for Pure Aortic Regurgitation in a Failed Stentless Bioprosthesis"],"prefix":"10.1016","volume":"31","author":[{"given":"Silvia","family":"Corona","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebasti\u00e1n","family":"Mrad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Remi","family":"Kouz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reda","family":"Ibrahim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Julien","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marina","family":"Ibrahim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christine","family":"Henri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Louis-Philippe","family":"David","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ralph Stephan","family":"von Bardeleben","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Walid","family":"Ben Ali","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"16","key":"10.1016\/j.jaccas.2026.108391_bib1","article-title":"Navigating the nuances: overcoming challenges in valve-in-valve TAVR for sutureless and stentless valves","volume":"29","author":"Zaid","year":"2024","journal-title":"JACC Case Rep"},{"key":"10.1016\/j.jaccas.2026.108391_bib2","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1093\/eurheartj\/ehx455","article-title":"Incidence, predictors, clinical outcomes of coronary obstruction following transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: insights from the VIVID registry","volume":"39","author":"Ribeiro","year":"2018","journal-title":"Eur Heart J"},{"issue":"6","key":"10.1016\/j.jaccas.2026.108391_bib3","first-page":"1106","article-title":"A comparison of valve-in-valve transcatheter aortic valve replacement in failed stentless versus stented surgical bioprosthetic aortic valves","volume":"93","author":"Choi","year":"2019","journal-title":"Catheter Cardiovasc Interv"},{"issue":"16","key":"10.1016\/j.jaccas.2026.108391_bib4","doi-asserted-by":"crossref","first-page":"1965","DOI":"10.1016\/j.jcin.2023.07.038","article-title":"Transcatheter aortic valve replacement for isolated aortic regurgitation using a new self-expanding TAVR system","volume":"16","author":"Adam","year":"2023","journal-title":"JACC Cardiovasc Interv"},{"issue":"10435","key":"10.1016\/j.jaccas.2026.108391_bib5","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.1016\/S0140-6736(23)02806-4","article-title":"Transcatheter aortic valve implantation in patients with high-risk symptomatic native aortic regurgitation (ALIGN-AR): a prospective, multicentre, single-arm study","volume":"403","author":"Vahl","year":"2024","journal-title":"Lancet"},{"issue":"6","key":"10.1016\/j.jaccas.2026.108391_bib6","doi-asserted-by":"crossref","first-page":"3488","DOI":"10.1002\/ehf2.14832","article-title":"Transcatheter aortic valve replacement for aortic regurgitation: a systematic review and meta-analysis","volume":"11","author":"Liu","year":"2024","journal-title":"ESC Heart Fail"},{"key":"10.1016\/j.jaccas.2026.108391_bib7","doi-asserted-by":"crossref","first-page":"1030","DOI":"10.1016\/j.jcin.2020.02.005","article-title":"Rationale, definitions, techniques, and outcomes of commissural alignment in TAVR from the ALIGN-TAVR consortium","volume":"13","author":"Tang","year":"2020","journal-title":"JACC Cardiovasc Interv"},{"issue":"19","key":"10.1016\/j.jaccas.2026.108391_bib8","doi-asserted-by":"crossref","first-page":"1974","DOI":"10.1016\/j.jcin.2023.07.026","article-title":"Transcatheter aortic valve replacement for pure native aortic valve regurgitation: the PANTHEON International project","volume":"16","author":"Poletti","year":"2023","journal-title":"JACC Cardiovasc Interv"},{"issue":"4","key":"10.1016\/j.jaccas.2026.108391_bib9","first-page":"766","article-title":"A heart valve dedicated for aortic regurgitation: review of technology and early clinical experience with the transfemoral Trilogy system","volume":"102","author":"Baumbach","year":"2023","journal-title":"Catheter Cardiovasc Interv"}],"container-title":["JACC: Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666084926015500?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666084926015500?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T19:55:49Z","timestamp":1782762949000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2666084926015500"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6]]},"references-count":9,"journal-issue":{"issue":"25","published-print":{"date-parts":[[2026,6]]}},"alternative-id":["S2666084926015500"],"URL":"https:\/\/doi.org\/10.1016\/j.jaccas.2026.108391","relation":{},"ISSN":["2666-0849"],"issn-type":[{"value":"2666-0849","type":"print"}],"subject":[],"published":{"date-parts":[[2026,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Dedicated Transcatheter Valve for Pure Aortic Regurgitation in a Failed Stentless Bioprosthesis","name":"articletitle","label":"Article Title"},{"value":"JACC: Case Reports","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jaccas.2026.108391","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.","name":"copyright","label":"Copyright"}],"article-number":"108391"}}