{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T09:36:15Z","timestamp":1785576975692,"version":"3.56.0"},"reference-count":31,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2017,6,1]],"date-time":"2017-06-01T00:00:00Z","timestamp":1496275200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2017,6,1]],"date-time":"2017-06-01T00:00:00Z","timestamp":1496275200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2018,6,2]],"date-time":"2018-06-02T00:00:00Z","timestamp":1527897600000},"content-version":"vor","delay-in-days":366,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jacc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JACC: Clinical Electrophysiology"],"published-print":{"date-parts":[[2017,6]]},"DOI":"10.1016\/j.jacep.2016.12.007","type":"journal-article","created":{"date-parts":[[2017,3,29]],"date-time":"2017-03-29T14:30:15Z","timestamp":1490797815000},"page":"623-631","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":19,"title":["Cleaning and Sterilization of Used Cardiac\u00a0Implantable Electronic Devices\u00a0With Process Validation"],"prefix":"10.1016","volume":"3","author":[{"given":"Thomas C.","family":"Crawford","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Craig","family":"Allmendinger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jay","family":"Snell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin","family":"Weatherwax","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Balasundaram","family":"Lavan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timir S.","family":"Baman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pat","family":"Sovitch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Alyesh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Carrigan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Noah","family":"Klugman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Denis","family":"Kune","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew","family":"Hughey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Lautenbach","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nathan","family":"Sovitch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karman","family":"Tandon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George","family":"Samson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles","family":"Newman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sheldon","family":"Davis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Archie","family":"Brown","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brad","family":"Wasserman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ed","family":"Goldman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandra L.","family":"Arlinghaus","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hakan","family":"Oral","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kim A.","family":"Eagle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jacep.2016.12.007_bib1","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.1056\/NEJM199804163381602","article-title":"Quality of life and clinical outcomes in elderly patients treated with ventricular pacing as compared with dual-chamber pacing. Pacemaker Selection in the Elderly Investigators","volume":"338","author":"Lamas","year":"1998","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.jacep.2016.12.007_bib2","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1111\/j.0954-6820.1978.tb14919.x","article-title":"Patients with high-grade atrioventricular block treated and not treated with a pacemaker","volume":"203","author":"Ohm","year":"1978","journal-title":"Acta Med Scand"},{"key":"10.1016\/j.jacep.2016.12.007_bib3","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1056\/NEJMoa043399","article-title":"Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure","volume":"352","author":"Bardy","year":"2005","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.jacep.2016.12.007_bib4","doi-asserted-by":"crossref","first-page":"1540","DOI":"10.1016\/j.jacc.2012.07.017","article-title":"Trends in permanent pacemaker implantation in the United States from 1993 to 2009: increasing complexity of patients and procedures","volume":"60","author":"Greenspon","year":"2012","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jacep.2016.12.007_bib5","doi-asserted-by":"crossref","first-page":"1013","DOI":"10.1111\/j.1540-8159.2011.03150.x","article-title":"The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: calendar year 2009\u2014a World Society of Arrhythmia's project","volume":"34","author":"Mond","year":"2011","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2016.12.007_bib6","doi-asserted-by":"crossref","first-page":"1649","DOI":"10.1161\/CIRCULATIONAHA.110.970483","article-title":"Pacemaker reuse: an initiative to alleviate the burden of symptomatic bradyarrhythmia in impoverished nations around the world","volume":"122","author":"Baman","year":"2010","journal-title":"Circulation"},{"key":"10.1016\/j.jacep.2016.12.007_bib7","doi-asserted-by":"crossref","first-page":"1177","DOI":"10.1161\/CIRCULATIONAHA.113.001584","article-title":"Reuse of pacemakers: comparison of short and long-term performance","volume":"127","author":"Nava","year":"2013","journal-title":"Circulation"},{"key":"10.1016\/j.jacep.2016.12.007_bib8","unstructured":"U.S. Food and Drug Administration (FDA). US FDA Compliance Manuals: CPG Section 310.100, Pacemaker Reuse (CPG 7124.12). Available at: http:\/\/www.fda.gov\/ICECI\/ComplianceManuals\/CompliancePolicyGuidanceManual\/ucm073891.htm Accessed January 24, 2016."},{"key":"10.1016\/j.jacep.2016.12.007_bib9","unstructured":"U.S. Department of Health and Human Services, Food and Drug Administration, Center for Devices and Radiological Health, Division of Enforcement III, Office of Compliance. Enforcement priorities for single-use devices reprocessed by third parties and hospitals. Available at: http:\/\/www.fda.gov\/OHRMS\/DOCKETS\/98fr\/000053g2.pdf. Accessed June 2,\u00a02014."},{"key":"10.1016\/j.jacep.2016.12.007_bib10","doi-asserted-by":"crossref","first-page":"1628","DOI":"10.1053\/euhj.1998.1298","article-title":"Re-use of devices in cardiology. Proceedings from a Policy Conference at the European Heart House, 5\u20136 February, 1998","volume":"19","author":"Ryden","year":"1998","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jacep.2016.12.007_bib11","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1016\/j.amjcard.2011.08.036","article-title":"Reuse\u00a0of explanted permanent pacemakers donated by funeral homes","volume":"109","author":"Kantharia","year":"2012","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jacep.2016.12.007_bib12","doi-asserted-by":"crossref","first-page":"542","DOI":"10.7326\/0003-4819-157-8-201210160-00004","article-title":"Reuse of explanted, resterilized implantable cardioverter-defibrillators: a cohort study","volume":"157","author":"Pavri","year":"2012","journal-title":"Ann Intern Med"},{"key":"10.1016\/j.jacep.2016.12.007_bib13","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/j.hrthm.2011.09.067","article-title":"Feasibility of postmortem device acquisition for potential reuse in underserved nations","volume":"9","author":"Baman","year":"2012","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2016.12.007_bib14","unstructured":"ANSI\/AAMI\/ISO 11135-1:2014. Sterilization of health care products\u2014ethylene oxide\u2014 part 1: requirements for development, validation, and routine control of a sterilization process for medical devices. Available at: https:\/\/www.iso.org\/obp\/ui\/#iso:std:56137:en. Accessed January 24, 2016."},{"key":"10.1016\/j.jacep.2016.12.007_bib15","unstructured":"AAMI TIR-30:2011. A compendium of processes, materials, test methods, and acceptance criteria for cleaning reusable medical devices. Available at: https:\/\/global.ihs.com\/doc_detail.cfm?&rid=ASA&item_s_key=00447201. Accessed January 24, 2016."},{"key":"10.1016\/j.jacep.2016.12.007_bib16","unstructured":"ANSI\/AAMI\/ISO 11737-1:2006. Sterilization of medical devices\u2014microbiological methods\u2014part 1: determination of population of microorganisms on\u00a0product. Available at: https:\/\/www.iso.org\/obp\/ui\/#iso:std:iso:11737:-1:ed-2:v1:en. Accessed January 24, 2016."},{"key":"10.1016\/j.jacep.2016.12.007_bib17","unstructured":"ANSI\/AAMI\/ISO 14161:2009. Sterilization of health care products\u2014biological indicators\u2014guidance for the selection, use, and interpretation of results. Available at: https:\/\/www.iso.org\/obp\/ui\/#iso:std:iso:14161:ed-2:v1:en. Accessed January 24, 2016."},{"key":"10.1016\/j.jacep.2016.12.007_bib18","unstructured":"US Pharmacopeia and National Formulary <643> Total organic carbon. Available at: https:\/\/hmc.usp.org\/sites\/default\/files\/documents\/HMC\/GCs-Pdfs\/c643.pdf. Accessed January 24, 2016."},{"key":"10.1016\/j.jacep.2016.12.007_bib19","unstructured":"ANSI\/AAMI\/ISO 10993-10:2010. Biological evaluation of medical devices\u2014part 10: tests for irritation and delayed type hypersensitivity. Available at: https:\/\/www.iso.org\/obp\/ui\/#iso:std:iso:10993:-10:ed-3:v1:en. Accessed January 24, 2016."},{"key":"10.1016\/j.jacep.2016.12.007_bib20","unstructured":"US Pharmacopeia and National Formulary.\u00a0<87> Biological reactivity tests, in\u00a0vitro. Available\u00a0at: http:\/\/www.usp.org\/sites\/default\/files\/usp_pdf\/EN\/USPNF\/iras\/gc-87-biolgoical-reactivity.pdf. Accessed January 24, 2016."},{"key":"10.1016\/j.jacep.2016.12.007_bib21","unstructured":"ANSI\/AAMI\/ISO 10993-5:2009. Biological evaluation of medical devices\u2014part 5: tests for\u00a0in\u00a0vitro cytotoxicity. Available at: https:\/\/www.iso.org\/obp\/ui\/#iso:std:iso:10993:-5:ed-3:v1:en. Accessed January 24, 2016."},{"key":"10.1016\/j.jacep.2016.12.007_bib22","unstructured":"FDA. Guidance for industry: pyrogen and endotoxins testing: questions and answers. June\u00a02012. Available at: http:\/\/www.fda.gov\/drugs\/guidancecomplianceregulatoryinformation\/guidances\/ucm314718.htm. Accessed August 20,\u00a02014."},{"key":"10.1016\/j.jacep.2016.12.007_bib23","unstructured":"ANSI\/AAMI\/ISO 10993-7:2008. Biological evaluation of medical devices\u2014part 7: ethylene oxide sterilization residuals. Available at: https:\/\/www.iso.org\/obp\/ui\/#iso:std:iso:10993:-7:ed-2:v1:en. Accessed January 24, 2016."},{"key":"10.1016\/j.jacep.2016.12.007_bib24","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1111\/pace.12321","article-title":"Cardiac implantable electronic device reutilization: battery life of explanted devices at a tertiary care center","volume":"37","author":"Gakenheimer","year":"2014","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2016.12.007_bib25","doi-asserted-by":"crossref","first-page":"720","DOI":"10.1086\/502609","article-title":"Cleaning and sterilization protocol for reused cardiac electrophysiology catheters inactivates hepatitis and coxsackie viruses","volume":"26","author":"Druce","year":"2005","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.jacep.2016.12.007_bib26","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1086\/502190","article-title":"A\u00a0decontamination and sterilization protocol employed during reuse of cardiac electrophysiology catheters inactivates human immunodeficiency virus","volume":"24","author":"Druce","year":"2003","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.jacep.2016.12.007_bib27","doi-asserted-by":"crossref","first-page":"1623","DOI":"10.1016\/j.hrthm.2010.04.027","article-title":"Reuse of pacemakers and defibrillators in developing countries: logistical, legal, and ethical barriers and solutions","volume":"7","author":"Kirkpatrick","year":"2010","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2016.12.007_bib28","doi-asserted-by":"crossref","first-page":"1348","DOI":"10.1086\/319997","article-title":"Creutzfeldt-Jakob disease: recommendations for disinfection and sterilization","volume":"32","author":"Rutala","year":"2001","journal-title":"Clin Infect Dis"},{"key":"10.1016\/j.jacep.2016.12.007_bib29","unstructured":"ISO 10993-5:2009. Biological evaluation of medical devices\u2014part 5: tests for in\u00a0vitro cytotoxicity. Available at: https:\/\/www.iso.org\/obp\/ui\/#iso:std:36406:en. Accessed January 24, 2016."},{"key":"10.1016\/j.jacep.2016.12.007_bib30","unstructured":"AAMI TIR 12:2010 Designing, Testing, And Labeling Reusable Medical Devices For Reprocessing In Health Care Facilities: A Guide For Medical Device Manufacturers. Available at: http:\/\/shop.standards.ie\/nsai\/details.aspx?ProductID=1442465. Accessed January 24, 2016."},{"key":"10.1016\/j.jacep.2016.12.007_bib31","unstructured":"ANSI\/AAMI\/ISO 10993-11:2006. Biological evaluation of medical devices\u2014part 11: tests for systemic toxicity. Available at: https:\/\/www.iso.org\/obp\/ui\/#iso:std:iso:10993:-11:ed-2:v1:en. Accessed January 24, 2016."}],"container-title":["JACC: Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405500X16305217?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405500X16305217?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T07:24:22Z","timestamp":1762500262000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2405500X16305217"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,6]]},"references-count":31,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2017,6]]}},"alternative-id":["S2405500X16305217"],"URL":"https:\/\/doi.org\/10.1016\/j.jacep.2016.12.007","relation":{},"ISSN":["2405-500X"],"issn-type":[{"value":"2405-500X","type":"print"}],"subject":[],"published":{"date-parts":[[2017,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Cleaning and Sterilization of Used Cardiac\u00a0Implantable Electronic Devices\u00a0With Process Validation","name":"articletitle","label":"Article Title"},{"value":"JACC: Clinical Electrophysiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jacep.2016.12.007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 by the American College of Cardiology Foundation. Published by Elsevier.","name":"copyright","label":"Copyright"}]}}