{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T02:01:24Z","timestamp":1767924084643,"version":"3.49.0"},"reference-count":25,"publisher":"Elsevier BV","issue":"7","license":[{"start":{"date-parts":[[2018,7,1]],"date-time":"2018-07-01T00:00:00Z","timestamp":1530403200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2018,7,1]],"date-time":"2018-07-01T00:00:00Z","timestamp":1530403200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2019,7,2]],"date-time":"2019-07-02T00:00:00Z","timestamp":1562025600000},"content-version":"vor","delay-in-days":366,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100008497","name":"Boston Scientific Corporation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008497","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100004374","name":"Medtronic","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004374","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100009947","name":"Merck Sharp and Dohme","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100009947","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100006279","name":"St. Jude Medical","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100006279","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100013410","name":"LivaNova","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100013410","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100005035","name":"Biotronik","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100005035","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100001316","name":"Abbott Laboratories","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100001316","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100007497","name":"Biosense Webster","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007497","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jacc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JACC: Clinical Electrophysiology"],"published-print":{"date-parts":[[2018,7]]},"DOI":"10.1016\/j.jacep.2018.02.005","type":"journal-article","created":{"date-parts":[[2018,3,28]],"date-time":"2018-03-28T16:12:53Z","timestamp":1522253573000},"page":"881-889","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":19,"title":["Pressure-Volume Loop Analysis of Multipoint Pacing With a Quadripolar Left\u00a0Ventricular Lead in Cardiac Resynchronization Therapy"],"prefix":"10.1016","volume":"4","author":[{"given":"Wouter M.","family":"van Everdingen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alwin","family":"Zweerink","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Odette A.E.","family":"Salden","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maarten J.","family":"Cramer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pieter A.","family":"Doevendans","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elien B.","family":"Engels","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Albert C.","family":"van Rossum","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frits W.","family":"Prinzen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kevin","family":"Vernooy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cornelis P.","family":"Allaart","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mathias","family":"Meine","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jacep.2018.02.005_bib1","doi-asserted-by":"crossref","first-page":"1318","DOI":"10.1016\/j.jacc.2012.12.017","article-title":"ACCF\/HRS\/AHA\/ASE\/HFSA\/SCAI\/SCCT\/SCMR 2013 appropriate use criteria for implantable cardioverter-defibrillators and cardiac resynchronization therapy","volume":"61","author":"Russo","year":"2013","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jacep.2018.02.005_bib2","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1093\/europace\/euv411","article-title":"2015 HRS\/EHRA\/APHRS\/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing","volume":"18","author":"Wilkoff","year":"2016","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2018.02.005_bib3","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1016\/j.jacc.2008.11.024","article-title":"Insights from a cardiac resynchronization optimization clinic as part of a heart failure disease management program","volume":"53","author":"Mullens","year":"2009","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jacep.2018.02.005_bib4","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/j.hrthm.2013.10.018","article-title":"Acute electrical and hemodynamic effects of multisite left ventricular pacing for cardiac resynchronization therapy in the dyssynchronous canine heart","volume":"11","author":"Ploux","year":"2014","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.02.005_bib5","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1016\/j.hrthm.2015.01.034","article-title":"Multipoint pacing by a left ventricular quadripolar lead improves the acute hemodynamic response to CRT compared with conventional biventricular pacing at any site","volume":"12","author":"Zanon","year":"2015","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.02.005_bib6","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1093\/europace\/eut420","article-title":"A\u00a0comparison of left ventricular endocardial, multisite, and multipolar epicardial cardiac resynchronization: an acute haemodynamic and electroanatomical study","author":"Shetty","year":"2014","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2018.02.005_bib7","first-page":"225","article-title":"Quadripolar leads in cardiac resynchronization therapy","volume":"1","author":"van Everdingen","year":"2015","journal-title":"J\u00a0Am Coll Cardiol EP"},{"key":"10.1016\/j.jacep.2018.02.005_bib8","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1016\/j.hrthm.2013.11.023","article-title":"Multipoint left ventricular pacing improves acute hemodynamic response assessed with pressure-volume loops in cardiac resynchronization therapy patients","volume":"11","author":"Pappone","year":"2014","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.02.005_bib9","doi-asserted-by":"crossref","first-page":"984","DOI":"10.1093\/europace\/eus435","article-title":"Acute haemodynamic comparison of multisite and biventricular pacing with a quadripolar left ventricular lead","volume":"15","author":"Thibault","year":"2013","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2018.02.005_bib10","doi-asserted-by":"crossref","first-page":"927","DOI":"10.1016\/j.amjcard.2010.11.010","article-title":"Defining left bundle branch block in the era of cardiac resynchronization therapy","volume":"107","author":"Strauss","year":"2011","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jacep.2018.02.005_bib11","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1016\/S0735-1097(01)01738-7","article-title":"A\u00a0standardized definition of ischemic cardiomyopathy for use in clinical research","volume":"39","author":"Felker","year":"2002","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jacep.2018.02.005_bib12","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1172\/JCI116540","article-title":"Myocardial electrical propagation in patients with idiopathic dilated cardiomyopathy","volume":"92","author":"Anderson","year":"1993","journal-title":"J\u00a0Clin Invest"},{"key":"10.1016\/j.jacep.2018.02.005_bib13","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.ijcard.2013.10.069","article-title":"Cardiac resynchronisation therapy optimisation strategies: systematic classification, detailed analysis, minimum standards and a roadmap for development and testing","volume":"170","author":"Sohaib","year":"2013","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.jacep.2018.02.005_bib14","doi-asserted-by":"crossref","first-page":"1262","DOI":"10.1093\/europace\/euq167","article-title":"Can optimization of pacing settings compensate for a non-optimal left ventricular pacing site?","volume":"12","author":"Bogaard","year":"2010","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2018.02.005_bib15","doi-asserted-by":"crossref","first-page":"e0154024","DOI":"10.1371\/journal.pone.0154024","article-title":"In heart failure patients with left bundle branch block single lead multispot left ventricular pacing does not improve acute hemodynamic response to conventional biventricular pacing. A multicenter prospective, interventional, non-randomized study","volume":"11","author":"Sterlinski","year":"2016","journal-title":"PLoS One"},{"key":"10.1016\/j.jacep.2018.02.005_bib16","first-page":"1508","article-title":"Improved patient selection for cardiac resynchronization therapy by normalization of QRS duration to left ventricular dimension","volume":"19","author":"Zweerink","year":"2017","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2018.02.005_bib17","first-page":"844","article-title":"Sex-specific response to cardiac resynchronization therapy","volume":"3","author":"Varma","year":"2017","journal-title":"J\u00a0Am Coll EP"},{"key":"10.1016\/j.jacep.2018.02.005_bib18","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1111\/j.1540-8159.2011.03243.x","article-title":"Biophysical modeling to simulate the response to multisite left ventricular stimulation using a quadripolar pacing lead","volume":"35","author":"Niederer","year":"2012","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2018.02.005_bib19","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1093\/europace\/eur336","article-title":"Multi-site left ventricular pacing as a potential treatment for patients with postero-lateral scar: insights from cardiac magnetic resonance imaging and invasive haemodynamic assessment","volume":"14","author":"Ginks","year":"2011","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2018.02.005_bib20","doi-asserted-by":"crossref","first-page":"2449","DOI":"10.1016\/j.hrthm.2015.07.012","article-title":"Mechanistic insights into the benefits of multisite pacing in cardiac resynchronization therapy: the importance of electrical substrate and rate of left ventricular activation","volume":"12","author":"Sohal","year":"2015","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.02.005_bib21","doi-asserted-by":"crossref","first-page":"1061","DOI":"10.1161\/CIRCULATIONAHA.110.960898","article-title":"effectiveness of cardiac resynchronization therapy by QRS morphology in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT)","volume":"123","author":"Zareba","year":"2011","journal-title":"Circulation"},{"key":"10.1016\/j.jacep.2018.02.005_bib22","first-page":"1510","article-title":"Safety and efficacy of multipoint pacing in cardiac resynchronization therapy","volume":"3","author":"Niazi","year":"2017","journal-title":"J\u00a0Am Coll EP"},{"key":"10.1016\/j.jacep.2018.02.005_bib23","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1093\/eurjhf\/hfs190","article-title":"Prediction of long-term outcome of cardiac resynchronization therapy by acute pressure-volume loop measurements","volume":"15","author":"de Roest","year":"2013","journal-title":"Eur J Heart Fail"},{"key":"10.1016\/j.jacep.2018.02.005_bib24","doi-asserted-by":"crossref","first-page":"948","DOI":"10.1111\/j.1540-8159.2012.03435.x","article-title":"Fully automatable, reproducible, noninvasive simple plethysmographic optimization: proof of concept and potential for implantability","volume":"35","author":"Kyriacou","year":"2012","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2018.02.005_bib25","doi-asserted-by":"crossref","first-page":"1746","DOI":"10.1093\/europace\/eus170","article-title":"Cardiac resynchronization therapy beyond nominal settings: who needs individual programming of the atrioventricular and interventricular delay?","volume":"14","author":"Bogaard","year":"2012","journal-title":"Europace"}],"container-title":["JACC: Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405500X18301191?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405500X18301191?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T07:25:29Z","timestamp":1762500329000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2405500X18301191"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7]]},"references-count":25,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2018,7]]}},"alternative-id":["S2405500X18301191"],"URL":"https:\/\/doi.org\/10.1016\/j.jacep.2018.02.005","relation":{},"ISSN":["2405-500X"],"issn-type":[{"value":"2405-500X","type":"print"}],"subject":[],"published":{"date-parts":[[2018,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Pressure-Volume Loop Analysis of Multipoint Pacing With a Quadripolar Left\u00a0Ventricular Lead in Cardiac Resynchronization Therapy","name":"articletitle","label":"Article Title"},{"value":"JACC: Clinical Electrophysiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jacep.2018.02.005","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 by the American College of Cardiology Foundation. Published by Elsevier.","name":"copyright","label":"Copyright"}]}}