{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T04:10:29Z","timestamp":1792642229084,"version":"4.5.0"},"reference-count":119,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2018,6,1]],"date-time":"2018-06-01T00:00:00Z","timestamp":1527811200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2018,6,1]],"date-time":"2018-06-01T00:00:00Z","timestamp":1527811200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2019,6,1]],"date-time":"2019-06-01T00:00:00Z","timestamp":1559347200000},"content-version":"vor","delay-in-days":365,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/501100001030","name":"National Heart Foundation of Australia","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001030","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001232","name":"Royal Australasian College of Physicians","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001232","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000925","name":"National Health and Medical Research Council","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000925","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jacc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JACC: Clinical Electrophysiology"],"published-print":{"date-parts":[[2018,6]]},"DOI":"10.1016\/j.jacep.2018.03.014","type":"journal-article","created":{"date-parts":[[2018,6,18]],"date-time":"2018-06-18T20:01:15Z","timestamp":1529352075000},"page":"707-723","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":112,"title":["Role of Contact Force Sensing in Catheter Ablation of Cardiac Arrhythmias"],"prefix":"10.1016","volume":"4","author":[{"given":"Nilshan","family":"Ariyarathna","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saurabh","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stuart P.","family":"Thomas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William G.","family":"Stevenson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory F.","family":"Michaud","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jacep.2018.03.014_bib1","doi-asserted-by":"crossref","first-page":"e004549","DOI":"10.1161\/JAHA.112.004549","article-title":"Long-term outcomes of catheter ablation of atrial fibrillation: a systematic review and meta-analysis","volume":"2","author":"Ganesan","year":"2013","journal-title":"J\u00a0Am Heart Assoc"},{"key":"10.1016\/j.jacep.2018.03.014_bib2","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1161\/CIRCULATIONAHA.104.533190","article-title":"Response of atrial fibrillation to pulmonary vein antrum isolation is directly related to resumption and delay of pulmonary vein conduction","volume":"112","author":"Verma","year":"2005","journal-title":"Circulation"},{"key":"10.1016\/j.jacep.2018.03.014_bib3","doi-asserted-by":"crossref","first-page":"1226","DOI":"10.1161\/01.CIR.0000121423.78120.49","article-title":"Resumption of electrical conduction in previously isolated pulmonary veins: rationale for a different strategy?","volume":"109","author":"Nanthakumar","year":"2004","journal-title":"Circulation"},{"key":"10.1016\/j.jacep.2018.03.014_bib4","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1161\/01.CIR.0000151289.73085.36","article-title":"Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: lessons from double Lasso technique","volume":"111","author":"Ouyang","year":"2005","journal-title":"Circulation"},{"key":"10.1016\/j.jacep.2018.03.014_bib5","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1161\/CIRCEP.111.964817","article-title":"Recovery of mitral isthmus conduction leads to the development of macro-reentrant tachycardia after left atrial linear ablation for atrial fibrillation","volume":"4","author":"Sawhney","year":"2011","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib6","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1016\/j.amjcard.2009.04.040","article-title":"Meta-analysis of ablation of atrial flutter and supraventricular tachycardia","volume":"104","author":"Spector","year":"2009","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib7","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1093\/europace\/eup098","volume":"11","author":"Aliot","year":"2009","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2018.03.014_bib8","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1111\/j.1540-8167.1991.tb01353.x","article-title":"Determinants of lesion size during radiofrequency catheter ablation: the role of electrode-tissue contact pressure and duration of energy delivery","volume":"2","author":"Haines","year":"1991","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib9","doi-asserted-by":"crossref","first-page":"1631","DOI":"10.1016\/j.hrthm.2017.07.023","article-title":"Safety of catheter ablation of atrial fibrillation using fiber optic-based contact force sensing","volume":"14","author":"Mansour","year":"2017","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.03.014_bib10","doi-asserted-by":"crossref","first-page":"1990","DOI":"10.1016\/j.hrthm.2015.06.026","article-title":"Use of contact force sensing technology during radiofrequency ablation reduces recurrence of atrial fibrillation: a systematic review and meta-analysis","volume":"12","author":"Afzal","year":"2015","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.03.014_bib11","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/j.hrthm.2017.10.010","article-title":"Contact force sensing for ablation of persistent atrial fibrillation: a randomized, multicenter trial","volume":"15","author":"Conti","year":"2017","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.03.014_bib12","doi-asserted-by":"crossref","first-page":"984","DOI":"10.1016\/j.hrthm.2014.03.019","article-title":"Comparison of lesion formation between contact force-guided and non-guided circumferential pulmonary vein isolation: a prospective, randomized study","volume":"11","author":"Kimura","year":"2014","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.03.014_bib13","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1007\/s10840-015-0056-7","article-title":"Randomized comparison of contact force-guided versus conventional circumferential pulmonary vein isolation of atrial fibrillation: prevalence, characteristics, and predictors of electrical reconnections and clinical outcomes","volume":"44","author":"Nakamura","year":"2015","journal-title":"J\u00a0Interv Card Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib14","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1111\/pace.12811","article-title":"Impact of contact force monitoring in acute pulmonary vein isolation using an anatomic approach. a randomized study","volume":"39","author":"Pedrote","year":"2016","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib15","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1161\/CIRCULATIONAHA.114.014092","volume":"132","author":"Reddy","year":"2015","journal-title":"Circulation"},{"key":"10.1016\/j.jacep.2018.03.014_bib16","doi-asserted-by":"crossref","first-page":"1761","DOI":"10.1016\/j.hrthm.2016.05.011","article-title":"Randomized trial comparing pulmonary vein isolation using the SmartTouch catheter with or without real-time contact force data","volume":"13","author":"Ullah","year":"2016","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.03.014_bib17","first-page":"S2","article-title":"Biophysics of ablation: application to technology","volume":"15 Suppl","author":"Haines","year":"2004","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib18","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1016\/S0735-1097(97)00435-X","article-title":"Effects of intracavitary blood flow and electrode-target distance on radiofrequency power required for transient conduction block in a Langendorff-perfused canine model","volume":"31","author":"Simmers","year":"1998","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib19","doi-asserted-by":"crossref","first-page":"1285","DOI":"10.1111\/j.1540-8159.2006.00533.x","article-title":"RF catheter ablation: lessons on lesions","volume":"29","author":"Wittkampf","year":"2006","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib20","doi-asserted-by":"crossref","first-page":"768","DOI":"10.1161\/01.CIR.100.7.768","article-title":"Is 8-mm more effective than 4-mm tip electrode catheter for ablation of typical atrial flutter?","volume":"100","author":"Tsai","year":"1999","journal-title":"Circulation"},{"key":"10.1016\/j.jacep.2018.03.014_bib21","doi-asserted-by":"crossref","first-page":"2264","DOI":"10.1161\/01.CIR.91.8.2264","article-title":"Comparison of in\u00a0vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation","volume":"91","author":"Nakagawa","year":"1995","journal-title":"Circulation"},{"key":"10.1016\/j.jacep.2018.03.014_bib22","series-title":"Catheter Ablation of Cardiac Arrhythmias","first-page":"4","article-title":"Biophysics of radiofrequency lesion formation","author":"Haines","year":"2006"},{"key":"10.1016\/j.jacep.2018.03.014_bib23","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1016\/j.jacc.2017.06.008","article-title":"Temperature-controlled radiofrequency ablation for pulmonary vein isolation in patients with atrial fibrillation","volume":"70","author":"Iwasawa","year":"2017","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib24","doi-asserted-by":"crossref","first-page":"1797","DOI":"10.1161\/01.CIR.0000058705.97823.F4","article-title":"Intramural coronary vasculature prevents transmural radiofrequency lesion formation: implications for linear ablation","volume":"107","author":"Fuller","year":"2003","journal-title":"Circulation"},{"key":"10.1016\/j.jacep.2018.03.014_bib25","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1007\/s10840-016-0147-0","article-title":"Wall thickness of the pulmonary vein-left atrial junction rather than electrical information as the major determinant of dormant conduction after contact force-guided pulmonary vein isolation","volume":"46","author":"Iso","year":"2016","journal-title":"J\u00a0Interv Card Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib26","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/S0002-8703(97)70242-4","article-title":"Biophysical characteristics of radiofrequency lesion formation in\u00a0vivo: dynamics of catheter tip-tissue contact evaluated by intracardiac echocardiography","volume":"133","author":"Kalman","year":"1997","journal-title":"Am Heart J"},{"key":"10.1016\/j.jacep.2018.03.014_bib27","doi-asserted-by":"crossref","first-page":"2899","DOI":"10.1111\/j.1540-8159.1997.tb05458.x","article-title":"The effects of electrode-tissue contact on radiofrequency lesion generation","volume":"20","author":"Avitall","year":"1997","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib28","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1161\/CIRCEP.108.803650","article-title":"Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus","volume":"1","author":"Yokoyama","year":"2008","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib29","doi-asserted-by":"crossref","first-page":"1038","DOI":"10.1111\/j.1540-8167.2010.01750.x","article-title":"Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in\u00a0vitro contractile model","volume":"21","author":"Shah","year":"2010","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib30","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1016\/j.eupc.2005.05.016","article-title":"Indication of the radiofrequency induced lesion size by pre-ablation measurements","volume":"7","author":"Stagegaard","year":"2005","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2018.03.014_bib31","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1046\/j.1460-9592.2002.00463.x","article-title":"Radiofrequency catheter ablation using cooled electrodes: impact of irrigation flow rate and catheter contact pressure on lesion dimensions","volume":"25","author":"Weiss","year":"2002","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib32","doi-asserted-by":"crossref","first-page":"1222","DOI":"10.1161\/CIRCEP.113.000184","article-title":"Characterization of catheter-tissue contact force during epicardial radiofrequency ablation in an ovine model","volume":"6","author":"Wong","year":"2013","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib33","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1111\/j.1540-8167.2008.01135.x","article-title":"A\u00a0systematical analysis of in\u00a0vivo contact forces on virtual catheter tip\/tissue surface contact during cardiac mapping and intervention","volume":"19","author":"Okumura","year":"2008","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib34","doi-asserted-by":"crossref","first-page":"1174","DOI":"10.1161\/CIRCEP.113.001094","volume":"7","author":"Ikeda","year":"2014","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib35","first-page":"775","article-title":"Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values","volume":"19","author":"Das","year":"2017","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2018.03.014_bib36","first-page":"1027","article-title":"The role of contact force in atrial fibrillation ablation","volume":"7","author":"Nakagawa","year":"2014","journal-title":"J\u00a0Atr Fibrillation"},{"key":"10.1016\/j.jacep.2018.03.014_bib37","first-page":"1114","article-title":"Impact of lowering irrigation flow rate on atrial lesion formation in thin atrial tissue","volume":"3","author":"Kumar","year":"2017","journal-title":"J\u00a0Am Coll Cardiol EP"},{"key":"10.1016\/j.jacep.2018.03.014_bib38","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1161\/CIRCEP.115.002779","article-title":"Real-time contact force measurement: a key parameter for controlling lesion creation with radiofrequency energy","volume":"8","author":"Shah","year":"2015","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib39","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.hrthm.2011.08.021","article-title":"A\u00a0novel radiofrequency ablation catheter using contact force sensing: Toccata study","volume":"9","author":"Kuck","year":"2012","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.03.014_bib40","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1007\/s10840-013-9824-4","article-title":"Effect of catheter movement and contact during application of radiofrequency energy on ablation lesion characteristics","volume":"38","author":"Olson","year":"2013","journal-title":"J\u00a0Interv Card Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib41","doi-asserted-by":"crossref","first-page":"e73242","DOI":"10.1371\/journal.pone.0073242","article-title":"Contact geometry affects lesion formation in radio-frequency cardiac catheter ablation","volume":"8","author":"Gallagher","year":"2013","journal-title":"PLoS One"},{"key":"10.1016\/j.jacep.2018.03.014_bib42","doi-asserted-by":"crossref","first-page":"1679","DOI":"10.1093\/europace\/eut351","article-title":"Characterization of the impact of catheter-tissue contact force in lesion formation during cavo-tricuspid isthmus ablation in an experimental swine model","volume":"16","author":"Matia Frances","year":"2014","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2018.03.014_bib43","first-page":"421","article-title":"The effect of contact force in atrial radiofrequency ablation: electroanatomical, cardiovascular magnetic resonance, and histological assessment in a chronic porcine model","volume":"1","author":"Williams","year":"2015","journal-title":"J\u00a0Am Coll Cardiol EP"},{"key":"10.1016\/j.jacep.2018.03.014_bib44","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1016\/j.ijcard.2016.07.186","article-title":"Impact of catheter tip-tissue contact on three-dimensional left atrial geometries: relationship between the external structures and anatomic distortion of 3D fast anatomical mapping and high contact force guided images","volume":"222","author":"Anjo","year":"2016","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib45","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1093\/europace\/euq403","article-title":"Catheter tip force required for mechanical perforation of porcine cardiac chambers","volume":"13","author":"Shah","year":"2011","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2018.03.014_bib46","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/j.hrthm.2014.11.028","article-title":"Optimal contact forces to minimize cardiac perforations before, during, and\/or after radiofrequency or cryothermal ablations","volume":"12","author":"Quallich","year":"2015","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.03.014_bib47","doi-asserted-by":"crossref","first-page":"1129","DOI":"10.1111\/pace.12409","article-title":"Contact-force recovery can predict cardiac perforation during radiofrequency ablation","volume":"37","author":"Nazeri","year":"2014","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib48","doi-asserted-by":"crossref","first-page":"806","DOI":"10.1111\/j.1540-8167.2009.01693.x","article-title":"Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex\u00a0vivo model using a force-sensing catheter","volume":"21","author":"Thiagalingam","year":"2010","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib49","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1161\/CIRCEP.111.974501","article-title":"Endocardial versus epicardial ventricular radiofrequency ablation: utility of in\u00a0vivo contact force assessment","volume":"6","author":"Sacher","year":"2013","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib50","doi-asserted-by":"crossref","first-page":"1168","DOI":"10.1161\/CIRCEP.113.001219","article-title":"Characterization of contact force during endocardial and epicardial ventricular mapping","volume":"7","author":"Jesel","year":"2014","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib51","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1111\/jce.13383","article-title":"Higher contact force, energy setting, and impedance rise during radiofrequency ablation predicts charring: new insights from contact force-guided in\u00a0vivo ablation","volume":"29","author":"Makimoto","year":"2017","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib52","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1111\/jce.13391","article-title":"Excessive contact force can overcome irrigated tip catheter benefits during atrial fibrillation ablation","volume":"29","author":"Bunch","year":"2017","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib53","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1111\/jce.13100","article-title":"Fiberoptic contact-force sensing electrophysiological catheters: how precise is the technology?","volume":"28","author":"Bourier","year":"2017","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib54","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1111\/jce.12886","article-title":"Electromagnetic contact-force sensing electrophysiological catheters: how accurate is the technology?","volume":"27","author":"Bourier","year":"2016","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib55","doi-asserted-by":"crossref","first-page":"826","DOI":"10.1111\/jce.12707","article-title":"High incidence of low catheter-tissue contact force at the cavotricuspid isthmus during catheter ablation of atrial flutter: implications for achieving isthmus block","volume":"26","author":"Kumar","year":"2015","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib56","doi-asserted-by":"crossref","first-page":"1124","DOI":"10.1161\/CIRCEP.112.972208","article-title":"Prospective characterization of catheter-tissue contact force at different anatomic sites during antral pulmonary vein isolation","volume":"5","author":"Kumar","year":"2012","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib57","doi-asserted-by":"crossref","first-page":"746","DOI":"10.1161\/CIRCEP.113.978320","article-title":"Locations of high contact force during left atrial mapping in atrial fibrillation patients: electrogram amplitude and impedance are poor predictors of electrode-tissue contact force for ablation of atrial fibrillation","volume":"6","author":"Nakagawa","year":"2013","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib58","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1111\/jce.12293","article-title":"Catheter-tissue contact force determines atrial electrogram characteristics before and lesion efficacy after antral pulmonary vein isolation in humans","volume":"25","author":"Kumar","year":"2014","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib59","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1016\/j.hrthm.2013.03.022","article-title":"Predictive value of impedance changes for real-time contact force measurements during catheter ablation of atrial arrhythmias in humans","volume":"10","author":"Kumar","year":"2013","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.03.014_bib60","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1161\/CIRCEP.113.001137","article-title":"Target indices for clinical ablation in atrial fibrillation: insights from contact force, electrogram, and biophysical parameter analysis","volume":"7","author":"Ullah","year":"2014","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib61","doi-asserted-by":"crossref","first-page":"1789","DOI":"10.1016\/j.hrthm.2012.07.016","article-title":"The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study","volume":"9","author":"Reddy","year":"2012","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.03.014_bib62","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1136\/heart.86.3.265","article-title":"Architecture of the pulmonary veins: relevance to radiofrequency ablation","volume":"86","author":"Ho","year":"2001","journal-title":"Heart"},{"key":"10.1016\/j.jacep.2018.03.014_bib63","doi-asserted-by":"crossref","first-page":"1282","DOI":"10.1111\/j.1540-8167.2007.00981.x","article-title":"Electrophysiologic and anatomic characterization of sites resistant to electrical isolation during circumferential pulmonary vein ablation for atrial fibrillation: a prospective study","volume":"18","author":"Kistler","year":"2007","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib64","doi-asserted-by":"crossref","first-page":"1195","DOI":"10.1088\/0967-3334\/29\/10\/004","article-title":"Myocardial electrical impedance as a predictor of the quality of RF-induced linear lesions","volume":"29","author":"Dumas Iii","year":"2008","journal-title":"Physiol Meas"},{"key":"10.1016\/j.jacep.2018.03.014_bib65","doi-asserted-by":"crossref","first-page":"1210","DOI":"10.1111\/jce.12215","article-title":"Ablation effect indicated by impedance fall is correlated with contact force level during ablation for atrial fibrillation","volume":"24","author":"De Bortoli","year":"2013","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib66","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.hrthm.2013.10.048","article-title":"Initial impedance decrease as an indicator of good catheter contact: insights from radiofrequency ablation with force sensing catheters","volume":"11","author":"Reichlin","year":"2014","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.03.014_bib67","doi-asserted-by":"crossref","first-page":"1030","DOI":"10.1161\/CIRCEP.114.002483","article-title":"Impact of catheter contact force on human left atrial electrogram characteristics in sinus rhythm and atrial fibrillation","volume":"8","author":"Ullah","year":"2015","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib68","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1111\/jce.12621","article-title":"Feasibility, efficacy, and safety of radiofrequency ablation of atrial fibrillation guided by monitoring of the initial impedance decrease as a surrogate of catheter contact","volume":"26","author":"Reichlin","year":"2015","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib69","doi-asserted-by":"crossref","first-page":"1390","DOI":"10.1111\/jce.13095","article-title":"Sites with small impedance decrease during catheter ablation for atrial fibrillation are associated with recovery of pulmonary vein conduction","volume":"27","author":"Chinitz","year":"2016","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib70","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1007\/s10840-015-0002-8","article-title":"Contact force and impedance decrease during ablation depends on catheter location and orientation: insights from pulmonary vein isolation using a contact force-sensing catheter","volume":"43","author":"Knecht","year":"2015","journal-title":"J\u00a0Interv Card Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib71","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.1016\/j.hrthm.2012.02.015","article-title":"Effect of respiration on catheter-tissue contact force during ablation of atrial arrhythmias","volume":"9","author":"Kumar","year":"2012","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.03.014_bib72","doi-asserted-by":"crossref","first-page":"997","DOI":"10.1007\/s00380-017-0961-z","article-title":"General anesthesia improves contact force and reduces gap formation in pulmonary vein isolation: a comparison with conscious sedation","volume":"32","author":"Chikata","year":"2017","journal-title":"Heart Vessels"},{"key":"10.1016\/j.jacep.2018.03.014_bib73","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1007\/s10840-016-0135-4","article-title":"Steerable versus non-steerable sheaths during pulmonary vein isolation: impact of left atrial enlargement on the catheter-tissue contact force","volume":"47","author":"Masuda","year":"2016","journal-title":"J\u00a0Interv Card Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib74","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1111\/jce.12573","article-title":"Impact of steerable sheaths on contact forces and reconnection sites in ablation for persistent atrial fibrillation","volume":"26","author":"Ullah","year":"2015","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib75","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1111\/jce.12542","article-title":"Factors affecting catheter contact in the human left atrium and their impact on ablation efficacy","volume":"26","author":"Ullah","year":"2015","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib76","doi-asserted-by":"crossref","first-page":"1160","DOI":"10.1016\/j.ijcard.2012.11.072","article-title":"Contact force sensing technology identifies sites of inadequate contact and reduces acute pulmonary vein reconnection: a prospective case control study","volume":"168","author":"Haldar","year":"2013","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib77","doi-asserted-by":"crossref","first-page":"1919","DOI":"10.1016\/j.hrthm.2014.07.033","article-title":"Pulmonary vein isolation using \u201ccontact force\u201d ablation: the effect on dormant conduction and long-term freedom from recurrent atrial fibrillation: a prospective study","volume":"11","author":"Andrade","year":"2014","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.03.014_bib78","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1093\/europace\/eut262","article-title":"Catheter-tissue contact force for pulmonary veins isolation: a pilot multicentre study on effect on procedure and fluoroscopy time","volume":"16","author":"Stabile","year":"2014","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2018.03.014_bib79","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1093\/europace\/euu329","article-title":"Low contact force and force-time integral predict early recovery and dormant conduction revealed by adenosine after pulmonary vein isolation","volume":"17","author":"le Polain de Waroux","year":"2015","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2018.03.014_bib80","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1161\/CIRCEP.113.000374","article-title":"Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: results from the EFFICAS I study","volume":"6","author":"Neuzil","year":"2013","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib81","doi-asserted-by":"crossref","first-page":"e002476","DOI":"10.1161\/JAHA.115.002476","article-title":"Impact of contact force technology on atrial fibrillation ablation: a meta-analysis","volume":"4","author":"Shurrab","year":"2015","journal-title":"J\u00a0Am Heart Assoc"},{"key":"10.1016\/j.jacep.2018.03.014_bib82","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/j.ijcard.2014.11.105","article-title":"A\u00a0prospective study on safety of catheter ablation procedures: contact force guided ablation could reduce the risk of cardiac perforation","volume":"179","author":"Akca","year":"2015","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib83","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1080\/14017431.2017.1285043","article-title":"Is the knowledge of contact force beneficial in pulmonary vein antrum isolation?","volume":"51","author":"Borregaard","year":"2017","journal-title":"Scand Cardiovasc J"},{"key":"10.1016\/j.jacep.2018.03.014_bib84","doi-asserted-by":"crossref","first-page":"1229","DOI":"10.1093\/europace\/euv057","article-title":"EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation","volume":"17","author":"Kautzner","year":"2015","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2018.03.014_bib85","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1016\/j.jacc.2014.04.072","article-title":"Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial","volume":"64","author":"Natale","year":"2014","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib86","first-page":"691","article-title":"Relationship between catheter stability and 12-month success after pulmonary vein isolation","volume":"2","author":"Reddy","year":"2016","journal-title":"J\u00a0Am Coll Cardiol EP"},{"key":"10.1016\/j.jacep.2018.03.014_bib87","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1093\/europace\/euu068","article-title":"Contact force and force-time integral in atrial radiofrequency ablation predict transmurality of lesions","volume":"16","author":"Squara","year":"2014","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2018.03.014_bib88","doi-asserted-by":"crossref","first-page":"1241","DOI":"10.1093\/europace\/eut058","article-title":"Remote magnetic with open-irrigated catheter vs. manual navigation for ablation of atrial fibrillation: a systematic review and meta-analysis","volume":"15","author":"Proietti","year":"2013","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2018.03.014_bib89","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1007\/s10840-017-0257-3","article-title":"A\u00a0meta-analysis of manual versus remote magnetic navigation for ventricular tachycardia ablation","volume":"49","author":"Turagam","year":"2017","journal-title":"J\u00a0Interv Card Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib90","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s10840-015-0023-3","article-title":"Magnetic guidance versus manual control: comparison of radiofrequency lesion dimensions and evaluation of the effect of heart wall motion in a myocardial phantom","volume":"44","author":"Bhaskaran","year":"2015","journal-title":"J\u00a0Interv Card Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib91","doi-asserted-by":"crossref","first-page":"745","DOI":"10.1111\/jce.13222","article-title":"Radiofrequency catheter ablation of atrial fibrillation: electrical modification suggesting transmurality is faster achieved with remote magnetic catheter in comparison with contact force use","volume":"28","author":"Bun","year":"2017","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib92","doi-asserted-by":"crossref","first-page":"893","DOI":"10.1111\/j.1540-8159.2008.01105.x","article-title":"Remote magnetic navigation-assisted catheter ablation enhances catheter stability and ablation success with lower catheter temperatures","volume":"31","author":"Davis","year":"2008","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib93","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1016\/j.hrthm.2014.02.022","article-title":"Radiofrequency ablation annotation algorithm reduces the incidence of linear gaps and reconnection after pulmonary vein isolation","volume":"11","author":"Anter","year":"2014","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.03.014_bib94","doi-asserted-by":"crossref","first-page":"941","DOI":"10.1111\/jce.12443","article-title":"Regional difference of optimal contact force to prevent acute pulmonary vein reconnection during radiofrequency catheter ablation for atrial fibrillation","volume":"25","author":"Sotomi","year":"2014","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib95","doi-asserted-by":"crossref","first-page":"e003155","DOI":"10.1161\/JAHA.115.003155","article-title":"Optimal force-time integral for pulmonary vein isolation according to anatomical wall thickness under the ablation line","volume":"5","author":"Chikata","year":"2016","journal-title":"J\u00a0Am Heart Assoc"},{"key":"10.1016\/j.jacep.2018.03.014_bib96","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1007\/s10840-016-0164-z","article-title":"Predictors of chronic pulmonary vein reconnections after contact force-guided ablation: importance of completing electrical isolation with circumferential lines and creating sufficient ablation lesion densities","volume":"47","author":"Nakamura","year":"2016","journal-title":"J\u00a0Interv Card Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib97","doi-asserted-by":"crossref","first-page":"1037","DOI":"10.1111\/jce.13281","article-title":"Prospective use of ablation index targets improves clinical outcomes following ablation for atrial fibrillation","volume":"28","author":"Hussein","year":"2017","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib98","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1016\/j.hrthm.2017.04.024","article-title":"Risk of atrioesophageal fistula formation with contact force-sensing catheters","volume":"14","author":"Black-Maier","year":"2017","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.03.014_bib99","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1161\/CIRCEP.110.960567","article-title":"Gaps in the ablation line as a potential cause of recovery from electrical isolation and their visualization using MRI","volume":"4","author":"Ranjan","year":"2011","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib100","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1016\/j.jacc.2011.09.076","article-title":"Histopathologic characterization of chronic radiofrequency ablation lesions for pulmonary vein isolation","volume":"59","author":"Kowalski","year":"2012","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib101","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1161\/CIRCEP.111.966523","article-title":"Acute pulmonary vein isolation is achieved by a combination of reversible and irreversible atrial injury after catheter ablation: evidence from magnetic resonance imaging","volume":"5","author":"Arujuna","year":"2012","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib102","first-page":"14","article-title":"The timing and frequency of pulmonary veins unexcitability relative to completion of a wide area circumferential ablation line for pulmonary vein isolation","volume":"2","author":"Baldinger","year":"2016","journal-title":"J\u00a0Am Coll Cardiol EP"},{"key":"10.1016\/j.jacep.2018.03.014_bib103","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1046\/j.1540-8167.2002.00056.x","article-title":"Acute and chronic electrophysiologic changes surrounding radiofrequency lesions","volume":"13","author":"Wood","year":"2002","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib104","doi-asserted-by":"crossref","first-page":"1723","DOI":"10.1161\/CIRCULATIONAHA.105.596593","article-title":"Effects of gap geometry on conduction through discontinuous radiofrequency lesions","volume":"113","author":"P\u00e9rez","year":"2006","journal-title":"Circulation"},{"key":"10.1016\/j.jacep.2018.03.014_bib105","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1023\/A:1009838201448","article-title":"The effect of a residual isthmus of surviving tissue on conduction after linear ablation in atrial myocardium","volume":"4","author":"Thomas","year":"2000","journal-title":"J\u00a0Interv Card Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib106","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1111\/jce.12396","article-title":"Mechanisms of pulmonary vein reconnection after radiofrequency ablation of atrial fibrillation: the deterministic role of contact force and interlesion distance","volume":"25","author":"Park","year":"2014","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib107","doi-asserted-by":"crossref","first-page":"e004867","DOI":"10.1161\/CIRCEP.116.004867","article-title":"Determinants of acute and late pulmonary vein reconnection in contact force-guided pulmonary vein isolation: identifying the weakest link in the ablation chain","volume":"10","author":"El Haddad","year":"2017","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib108","doi-asserted-by":"crossref","first-page":"1130","DOI":"10.1161\/CIRCEP.112.973164","article-title":"Identification and acute targeting of gaps in atrial ablation lesion sets using a real-time magnetic resonance imaging system","volume":"5","author":"Ranjan","year":"2012","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib109","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1161\/CIRCEP.115.002894","article-title":"Elimination of the negative component of the unipolar atrial electrogram as an in\u00a0vivo marker of transmural lesion creation: acute study in canines","volume":"8","author":"Bortone","year":"2015","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib110","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1016\/j.hrthm.2010.06.014","article-title":"Local unipolar and bipolar electrogram criteria for evaluating the transmurality of atrial ablation lesions at different catheter orientations relative to the endocardial surface","volume":"7","author":"Otomo","year":"2010","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.03.014_bib111","doi-asserted-by":"crossref","first-page":"1095","DOI":"10.1161\/CIRCEP.113.000749","article-title":"Unipolar signal modification as a guide for lesion creation during radiofrequency application in the left atrium: a prospective study in humans in the setting of paroxysmal atrial fibrillation catheter ablation","volume":"6","author":"Bortone","year":"2013","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib112","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1093\/europace\/eus381","article-title":"Loss of pace capture after radiofrequency application predicts the formation of uniform transmural lesions","volume":"15","author":"Kosmidou","year":"2013","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2018.03.014_bib113","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1016\/j.hrthm.2009.11.011","article-title":"Loss of pace capture on the ablation line: a new marker for complete radiofrequency lesions to achieve pulmonary vein isolation","volume":"7","author":"Steven","year":"2010","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.03.014_bib114","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1016\/j.jacc.2013.03.059","article-title":"Benefit of pulmonary vein isolation guided by loss of pace capture on the ablation line: results from a prospective 2-center randomized trial","volume":"62","author":"Steven","year":"2013","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib115","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.113.000454","article-title":"Pulmonary vein isolation using a pace-capture guided versus an adenosine guided approach: effect on dormant conduction and long-term freedom from recurrent atrial fibrillation: a prospective study","volume":"6","author":"Andrade","year":"2013","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib116","first-page":"1262","article-title":"5-Year outcome of pulmonary vein isolation by loss of pace capture on the ablation line versus electrical circumferential pulmonary vein isolation","volume":"3","author":"Moser","year":"2017","journal-title":"J\u00a0Am Coll Cardiol EP"},{"key":"10.1016\/j.jacep.2018.03.014_bib117","doi-asserted-by":"crossref","DOI":"10.1111\/jce.12762","article-title":"Safety and clinical outcome of catheter ablation of ventricular arrhythmias using contact force sensing: consecutive case series","author":"Hendriks","year":"2015","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib118","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1111\/jce.12080","article-title":"Contact force monitoring for cardiac mapping in patients with ventricular tachycardia","volume":"24","author":"Mizuno","year":"2013","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.03.014_bib119","doi-asserted-by":"crossref","first-page":"230","DOI":"10.4330\/wjc.v9.i3.230","article-title":"Paroxysmal atrial fibrillation ablation: achieving permanent pulmonary vein isolation by point-by-point radiofrequency lesions","volume":"9","author":"Pedrote","year":"2017","journal-title":"World J Cardiol"}],"container-title":["JACC: Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405500X18302834?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405500X18302834?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T07:25:14Z","timestamp":1762500314000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2405500X18302834"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6]]},"references-count":119,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2018,6]]}},"alternative-id":["S2405500X18302834"],"URL":"https:\/\/doi.org\/10.1016\/j.jacep.2018.03.014","relation":{},"ISSN":["2405-500X"],"issn-type":[{"value":"2405-500X","type":"print"}],"subject":[],"published":{"date-parts":[[2018,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Role of Contact Force Sensing in Catheter Ablation of Cardiac Arrhythmias","name":"articletitle","label":"Article Title"},{"value":"JACC: Clinical Electrophysiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jacep.2018.03.014","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 by the American College of Cardiology Foundation. Published by Elsevier.","name":"copyright","label":"Copyright"}]}}