{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,26]],"date-time":"2026-02-26T15:37:51Z","timestamp":1772120271982,"version":"3.50.1"},"reference-count":75,"publisher":"Elsevier BV","issue":"7","license":[{"start":{"date-parts":[[2018,7,1]],"date-time":"2018-07-01T00:00:00Z","timestamp":1530403200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2018,7,1]],"date-time":"2018-07-01T00:00:00Z","timestamp":1530403200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2019,7,2]],"date-time":"2019-07-02T00:00:00Z","timestamp":1562025600000},"content-version":"vor","delay-in-days":366,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100004374","name":"Medtronic","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004374","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100007497","name":"Biosense Webster","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007497","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100008497","name":"Boston Scientific Corporation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008497","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100003793","name":"Hj\u00e4rt-Lungfonden","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100003793","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100005035","name":"Biotronik","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100005035","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jacc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JACC: Clinical Electrophysiology"],"published-print":{"date-parts":[[2018,7]]},"DOI":"10.1016\/j.jacep.2018.04.014","type":"journal-article","created":{"date-parts":[[2018,6,27]],"date-time":"2018-06-27T20:59:09Z","timestamp":1530133149000},"page":"847-859","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":21,"title":["Management of Arrhythmias and Cardiac Implantable Electronic Devices in Patients\u00a0With\u00a0Left Ventricular Assist Devices"],"prefix":"10.1016","volume":"4","author":[{"given":"Gordon","family":"Ho","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oscar \u00d6.","family":"Braun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eric D.","family":"Adler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gregory K.","family":"Feld","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Victor G.","family":"Pretorius","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ulrika","family":"Birgersdotter-Green","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jacep.2018.04.014_bib1","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1056\/NEJMoa012175","article-title":"Long-term use of a left ventricular assist device for end-stage heart failure","volume":"345","author":"Rose","year":"2001","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.jacep.2018.04.014_bib2","doi-asserted-by":"crossref","first-page":"2241","DOI":"10.1056\/NEJMoa0909938","article-title":"Advanced heart failure treated with continuous-flow left ventricular assist device","volume":"361","author":"Slaughter","year":"2009","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.jacep.2018.04.014_bib3","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1056\/NEJMoa1610426","article-title":"A\u00a0fully magnetically levitated circulatory pump for advanced heart failure","volume":"376","author":"Mehra","year":"2017","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.jacep.2018.04.014_bib4","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1056\/NEJMoa1602954","article-title":"Intrapericardial left ventricular assist device for advanced heart failure","volume":"376","author":"Rogers","year":"2017","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.jacep.2018.04.014_bib5","doi-asserted-by":"crossref","first-page":"1080","DOI":"10.1016\/j.healun.2017.07.005","article-title":"Eighth annual INTERMACS report: special focus on framing the impact of adverse events","volume":"36","author":"Kirklin","year":"2017","journal-title":"J\u00a0Heart Lung Transplant"},{"key":"10.1016\/j.jacep.2018.04.014_bib6","first-page":"369","article-title":"Implant strategies change over time and impact outcomes: insights from the INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support)","volume":"1","author":"Teuteberg","year":"2013","journal-title":"J\u00a0Am Coll Cardiol HF"},{"key":"10.1016\/j.jacep.2018.04.014_bib7","doi-asserted-by":"crossref","first-page":"1540","DOI":"10.1016\/j.jacc.2016.07.743","article-title":"Cardiac recovery during long-term left ventricular assist device support","volume":"68","author":"Wever-Pinzon","year":"2016","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib8","doi-asserted-by":"crossref","first-page":"2542","DOI":"10.1016\/j.jacc.2013.04.020","article-title":"Ventricular arrhythmias and implantable cardioverter-defibrillator therapy in patients with continuous-flow left ventricular assist devices: need for primary prevention?","volume":"61","author":"Garan","year":"2013","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib9","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.healun.2012.10.001","article-title":"Axial and centrifugal continuous-flow rotary pumps: a translation from pump mechanics to clinical practice","volume":"32","author":"Moazami","year":"2013","journal-title":"J\u00a0Heart Lung Transplant"},{"key":"10.1016\/j.jacep.2018.04.014_bib10","doi-asserted-by":"crossref","first-page":"1164","DOI":"10.1016\/j.healun.2017.05.008","article-title":"Bleeding and thrombosis associated with ventricular assist device therapy","volume":"36","author":"Shah","year":"2017","journal-title":"J\u00a0Heart Lung Transplant"},{"key":"10.1016\/j.jacep.2018.04.014_bib11","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1016\/j.healun.2009.03.011","article-title":"Incidence of ventricular arrhythmias in patients on long-term support with a continuous-flow assist device (HeartMate II)","volume":"28","author":"Andersen","year":"2009","journal-title":"J\u00a0Heart Lung Transplant"},{"key":"10.1016\/j.jacep.2018.04.014_bib12","doi-asserted-by":"crossref","first-page":"1151","DOI":"10.1016\/j.amjcard.2006.11.051","article-title":"Ventricular arrhythmias during left ventricular assist device support","volume":"99","author":"Bedi","year":"2007","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib13","doi-asserted-by":"crossref","first-page":"1611","DOI":"10.1016\/j.healun.2015.05.018","article-title":"Early post-operative ventricular arrhythmias in patients with continuous-flow left ventricular assist devices","volume":"34","author":"Garan","year":"2015","journal-title":"J\u00a0Heart Lung Transplant"},{"key":"10.1016\/j.jacep.2018.04.014_bib14","doi-asserted-by":"crossref","first-page":"1246","DOI":"10.1111\/j.1540-8159.2008.01173.x","article-title":"Ventricular arrhythmias after left ventricular assist device implantation","volume":"31","author":"Refaat","year":"2008","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib15","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1016\/j.healun.2010.02.001","article-title":"Implantable cardioverter-defibrillator shocks in patients with a left ventricular assist device","volume":"29","author":"Ambardekar","year":"2010","journal-title":"J\u00a0Heart Lung Transplant"},{"key":"10.1016\/j.jacep.2018.04.014_bib16","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1016\/j.hrthm.2009.12.022","article-title":"Improved survival among ventricular assist device recipients with a concomitant implantable cardioverter-defibrillator","volume":"7","author":"Cantillon","year":"2010","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.04.014_bib17","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1097\/MAT.0000000000000349","article-title":"Arrhythmias in patients with cardiac implantable electrical devices after implantation of a left ventricular assist device","volume":"62","author":"Rosenbaum","year":"2016","journal-title":"ASAIO J"},{"key":"10.1016\/j.jacep.2018.04.014_bib18","doi-asserted-by":"crossref","first-page":"1052","DOI":"10.1016\/j.hrthm.2016.01.033","article-title":"Predictors and clinical relevance of ventricular tachyarrhythmias in ambulatory patients with a continuous flow left ventricular assist device","volume":"13","author":"Yoruk","year":"2016","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.04.014_bib19","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1016\/j.ejcts.2004.05.010","article-title":"Left ventricular assist device (LVAD) enables survival during 7 h of sustained ventricular fibrillation","volume":"26","author":"Salzberg","year":"2004","journal-title":"Eur J Cardiothor Surg"},{"key":"10.1016\/j.jacep.2018.04.014_bib20","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1016\/j.healun.2013.11.005","article-title":"Low cardiac output associated with ventricular tachyarrhythmias in continuous-flow LVAD recipients with a concomitant ICD (LoCo VT Study)","volume":"33","author":"Cantillon","year":"2014","journal-title":"J\u00a0Heart Lung Transplant"},{"key":"10.1016\/j.jacep.2018.04.014_bib21","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1097\/MAT.0000000000000061","article-title":"Catheter ablation for ventricular tachyarrhythmias in patients supported by continuous-flow left ventricular assist devices","volume":"60","author":"Garan","year":"2014","journal-title":"ASAIO J"},{"key":"10.1016\/j.jacep.2018.04.014_bib22","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1161\/CIRCEP.108.769471","article-title":"Ventricular tachycardia ablation: evolution of patients and procedures over 8 years","volume":"1","author":"Sacher","year":"2008","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib23","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1016\/j.healun.2007.05.011","article-title":"Suction events during left ventricular support and ventricular arrhythmias","volume":"26","author":"Vollkron","year":"2007","journal-title":"J\u00a0Heart Lung Transplant"},{"key":"10.1016\/j.jacep.2018.04.014_bib24","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1161\/CIRCEP.114.002394","article-title":"Characteristics of ventricular tachycardia ablation in patients with continuous flow left ventricular assist devices","volume":"8","author":"Sacher","year":"2015","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib25","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/j.hrthm.2012.01.018","article-title":"Electrophysiologic characteristics and catheter ablation of ventricular tachyarrhythmias among patients with heart failure on ventricular assist device support","volume":"9","author":"Cantillon","year":"2012","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2018.04.014_bib26","first-page":"CD008093","article-title":"Amiodarone versus other pharmacological interventions for prevention of sudden cardiac death. Cochrane Heart Group, editor","volume":"352","author":"Claro","year":"2015","journal-title":"Cochrane Database Syst Rev"},{"key":"10.1016\/j.jacep.2018.04.014_bib27","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1016\/j.healun.2016.07.009","article-title":"Amiodarone use in patients listed for heart transplant is associated with increased 1-year post-transplant mortality","volume":"36","author":"Cooper","year":"2017","journal-title":"J\u00a0Heart Lung Transplant"},{"key":"10.1016\/j.jacep.2018.04.014_bib28","first-page":"1412","article-title":"Characterization of ventricular tachycardia after left ventricular assist device implantation as destination therapy: a single-center ablation experience","volume":"3","author":"Moss","year":"2017","journal-title":"J\u00a0Am Coll Cardiol EP"},{"key":"10.1016\/j.jacep.2018.04.014_bib29","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1111\/jce.13114","article-title":"Effect of ventricular arrhythmia ablation in patients with heart mate ii left ventricular assist devices: an evaluation of ablation therapy","volume":"28","author":"Snipelisky","year":"2017","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib30","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1111\/chf.12034","article-title":"Catheter ablation of atrial flutter in patients with left ventricular assist device improves symptoms of right heart failure","volume":"19","author":"Hottigoudar","year":"2013","journal-title":"Congest Heart Fail"},{"key":"10.1016\/j.jacep.2018.04.014_bib31","doi-asserted-by":"crossref","first-page":"1207","DOI":"10.1016\/j.jtcvs.2012.03.061","article-title":"Cryoablation during left ventricular assist device implantation reduces postoperative ventricular tachyarrhythmias","volume":"145","author":"Mulloy","year":"2013","journal-title":"J\u00a0Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jacep.2018.04.014_bib32","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1111\/jce.12839","article-title":"Safety and feasibility of open chest epicardial mapping and ablation of ventricular tachycardia during the period of left ventricular assist device implantation","volume":"27","author":"Patel","year":"2016","journal-title":"J\u00a0CardiovascElectrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib33","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1016\/j.healun.2016.11.008","article-title":"The role of implantable cardioverter defibrillators in patients bridged to transplantation with a continuous-flow left ventricular assist device: a propensity score matched analysis","volume":"36","author":"Clerkin","year":"2017","journal-title":"J\u00a0Heart Lung Transplant"},{"key":"10.1016\/j.jacep.2018.04.014_bib34","author":"Al-Khatib","year":"2017","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib35","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.healun.2012.09.013","article-title":"The 2013 International Society for Heart and Lung Transplantation guidelines for mechanical circulatory support: executive summary","volume":"32","author":"Feldman","year":"2013","journal-title":"J\u00a0Heart Lung Transplant"},{"key":"10.1016\/j.jacep.2018.04.014_bib36","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/j.cardfail.2011.10.020","article-title":"Survival benefit of implantable cardioverter-defibrillators in left ventricular assist device-supported heart failure patients","volume":"18","author":"Refaat","year":"2012","journal-title":"J\u00a0Card Fail"},{"key":"10.1016\/j.jacep.2018.04.014_bib37","doi-asserted-by":"crossref","first-page":"925","DOI":"10.1111\/pace.12654","article-title":"Impact of implantable cardioverter defibrillators on survival of patients with centrifugal left ventricular assist devices","volume":"38","author":"Lee","year":"2015","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib38","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1161\/CIRCEP.113.000457","article-title":"The role of implantable cardioverter-defibrillators in patients with continuous flow left ventricular assist devices","volume":"6","author":"Enriquez","year":"2013","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib39","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1016\/j.ijcard.2016.07.257","article-title":"The role of implantable cardioverter-defibrillators in patients with continuous flow left ventricular assist devices \u2014 a meta-analysis","volume":"222","author":"Agrawal","year":"2016","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib40","first-page":"916","article-title":"Implantable cardioverter-defibrillators in patients with a continuous-flow left ventricular assist device","volume":"5","author":"Clerkin","year":"2017","journal-title":"J\u00a0Am Coll Cardiol HF"},{"key":"10.1016\/j.jacep.2018.04.014_bib41","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1111\/j.1540-8159.2009.02569.x","article-title":"Continued rise in rates of cardiovascular implantable electronic device infections in the United States: temporal trends and causative insights","volume":"33","author":"Voigt","year":"2010","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib42","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1111\/pace.12240","article-title":"Cardiovascular implantable electronic device infections in left ventricular assist device recipients","volume":"37","author":"Riaz","year":"2014","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib43","doi-asserted-by":"crossref","first-page":"1199","DOI":"10.1111\/jce.12461","article-title":"Cardiac implantable electronic device removal in patients with left ventricular assist device associated infections","volume":"25","author":"Krishnamoorthy","year":"2014","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib44","doi-asserted-by":"crossref","first-page":"183","DOI":"10.14503\/THIJ-14-4795","article-title":"No electromagnetic interference occurred in a patient with a HeartMate II left ventricular assist system and a subcutaneous implantable cardioverter-defibrillator","volume":"43","author":"Raman","year":"2016","journal-title":"Tex Heart Inst J"},{"key":"10.1016\/j.jacep.2018.04.014_bib45","doi-asserted-by":"crossref","first-page":"140","DOI":"10.14503\/THIJ-14-4166","article-title":"Subcutaneous implantable cardioverter-defibrillator implantation in a patient with a left ventricular assist device already in place","volume":"42","author":"Gupta","year":"2015","journal-title":"Tex Heart Inst J"},{"key":"10.1016\/j.jacep.2018.04.014_bib46","doi-asserted-by":"crossref","first-page":"e32","DOI":"10.1161\/CIRCEP.113.000240","article-title":"Left ventricular assist device in a patient with a concomitant subcutaneous implantable cardioverter defibrillator","volume":"6","author":"Saeed","year":"2013","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib47","doi-asserted-by":"crossref","first-page":"e004633","DOI":"10.1161\/CIRCEP.116.004633","article-title":"Subcutaneous implantable cardioverter-defibrillator shocks after left ventricular assist device implantation","volume":"9","author":"Pfeffer","year":"2016","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib48","doi-asserted-by":"crossref","first-page":"e30","DOI":"10.1016\/j.ejim.2017.05.004","article-title":"Should subcutaneous implantable cardioverter-defibrillators be implanted in patients who are candidates for continuous flow left ventricular assist device?","volume":"43","author":"Raffa","year":"2017","journal-title":"Eur J Int Med"},{"key":"10.1016\/j.jacep.2018.04.014_bib49","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1016\/j.amjcard.2009.09.044","article-title":"Simultaneous use of implantable cardioverter-defibrillators and left ventricular assist devices in patients with severe heart failure","volume":"105","author":"K\u00fchne","year":"2010","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib50","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1007\/s10840-013-9854-y","article-title":"Clinical implications of left ventricular assist device implantation in patients with an implantable cardioverter-defibrillator","volume":"39","author":"Boudgh\u00e8ne-Stambouli","year":"2014","journal-title":"J\u00a0Interv Card Electrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib51","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1111\/j.1540-8167.2007.00805.x","article-title":"Adverse interaction between a left ventricular assist device and an implantable cardioverter defibrillator","volume":"18","author":"Matthews","year":"2007","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib52","doi-asserted-by":"crossref","first-page":"1613","DOI":"10.1016\/j.jacc.2008.01.025","article-title":"Device interactions in patients with advanced cardiomyopathy","volume":"51","author":"Mehta","year":"2008","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib53","doi-asserted-by":"crossref","first-page":"945","DOI":"10.1111\/j.1540-8159.2009.02419.x","article-title":"Overcoming electromagnetic interference by LVADs on ICD function by shielding the ICD programmer wand and extension cable","volume":"32","author":"Biviano","year":"2009","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib54","doi-asserted-by":"crossref","first-page":"e272","DOI":"10.1111\/j.1540-8159.2012.03370.x","article-title":"Interactions between a left ventricular assist device and implantable cardioverter-defibrillator","volume":"35","author":"Netzler","year":"2012","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib55","doi-asserted-by":"crossref","first-page":"909","DOI":"10.1111\/j.1540-8159.2009.02676.x","article-title":"The creative method to reduce device-device interferences","volume":"33","author":"Duncker","year":"2010","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib56","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1111\/pace.13210","article-title":"A\u00a0case of electromagnetic interference between HeartMate 3 LVAD and implantable cardioverter defibrillator","volume":"41","author":"Sehatbakhsh","year":"2018","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib57","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1007\/s00399-017-0509-z","article-title":"Electric smog: telemetry interference between ICD and LVAD","volume":"28","author":"Duncker","year":"2017","journal-title":"Herzschrittmacherther Elektrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib58","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1007\/s10840-009-9415-6","article-title":"\u201cPseudo\u201d Faraday cage: a solution for telemetry link interaction between a left ventricular assist device and an implantable cardioverter defibrillator","volume":"28","author":"Jacob","year":"2010","journal-title":"J\u00a0Interv Card Electrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib59","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1016\/j.cardfail.2009.12.003","article-title":"Effect of left ventricular assist device placement on preexisting implantable cardioverter-defibrillator leads","volume":"16","author":"Ambardekar","year":"2010","journal-title":"J\u00a0Card Fail"},{"key":"10.1016\/j.jacep.2018.04.014_bib60","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1111\/pace.12290","article-title":"ICD lead parameters, performance, and adverse events following continuous-flow LVAD implantation","volume":"37","author":"Thomas","year":"2014","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib61","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1111\/jce.12273","article-title":"Programming implantable cardioverter-defibrillators in patients with primary prevention indication to prolong time to first shock: results from the PROVIDE study","volume":"25","author":"Saeed","year":"2014","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib62","doi-asserted-by":"crossref","first-page":"1903","DOI":"10.1001\/jama.2013.4598","article-title":"Effect of long-detection interval vs standard-detection interval for implantable cardioverter-defibrillators on antitachycardia pacing and shock delivery: the ADVANCE III randomized clinical trial","volume":"309","author":"Gasparini","year":"2013","journal-title":"JAMA"},{"key":"10.1016\/j.jacep.2018.04.014_bib63","doi-asserted-by":"crossref","first-page":"2591","DOI":"10.1161\/01.CIR.0000145610.64014.E4","volume":"110","author":"Wathen","year":"2004","journal-title":"Circulation"},{"key":"10.1016\/j.jacep.2018.04.014_bib64","doi-asserted-by":"crossref","first-page":"2275","DOI":"10.1056\/NEJMoa1211107","article-title":"Reduction in inappropriate therapy and mortality through ICD programming","volume":"367","author":"Moss","year":"2012","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.jacep.2018.04.014_bib65","doi-asserted-by":"crossref","first-page":"e007748","DOI":"10.1161\/JAHA.117.007748","article-title":"Prospective randomized evaluation of implantable cardioverter-defibrillator programming in patients with a left ventricular assist device","volume":"7","author":"Richardson","year":"2018","journal-title":"J\u00a0Am Heart Assoc"},{"key":"10.1016\/j.jacep.2018.04.014_bib66","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1016\/j.amjcard.2016.05.050","article-title":"Effect of continued cardiac resynchronization therapy on ventricular arrhythmias after left ventricular assist device implantation","volume":"118","author":"Schleifer","year":"2016","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib67","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1016\/j.cardfail.2014.12.006","article-title":"Impact of cardiac resynchronization therapy on clinical outcomes in patients with continuous-flow left ventricular assist devices","volume":"21","author":"Gopinathannair","year":"2015","journal-title":"J\u00a0Card Fail"},{"key":"10.1016\/j.jacep.2018.04.014_bib68","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1046\/j.1540-8167.2003.03303.x","article-title":"Increase in ventricular tachycardia frequency after biventricular implantable cardioverter defibrillator upgrade","volume":"14","author":"Guerra","year":"2003","journal-title":"J\u00a0CardiovascElectrophysiol"},{"key":"10.1016\/j.jacep.2018.04.014_bib69","doi-asserted-by":"crossref","first-page":"906","DOI":"10.1016\/j.healun.2016.03.003","article-title":"Preoperative atrial fibrillation may not increase thromboembolic events in left ventricular assist device recipients on midterm follow-up","volume":"35","author":"Xia","year":"2016","journal-title":"J\u00a0Heart Lung Transplant"},{"key":"10.1016\/j.jacep.2018.04.014_bib70","doi-asserted-by":"crossref","unstructured":"Enriquez AD, Calenda B, Gandhi PU, Nair AP, Anyanwu AC, Pinney SP. Clinical impact of atrial fibrillation in patients with the HeartMate II left ventricular assist device. J Am Coll Cardiol 2014;64:1883\u201390.","DOI":"10.1016\/j.jacc.2014.07.989"},{"key":"10.1016\/j.jacep.2018.04.014_bib71","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1111\/jocs.12336","article-title":"The incidence, risk, and consequences of atrial arrhythmias in patients with continuous-flow left ventricular assist devices","volume":"29","author":"Brisco","year":"2014","journal-title":"J\u00a0Card Surg"},{"key":"10.1016\/j.jacep.2018.04.014_bib72","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1097\/MAT.0000000000000520","article-title":"Permanent atrial fibrillation and 2 year clinical outcomes in patients with a left ventricular assist device implant","volume":"63","author":"Oezpeker","year":"2017","journal-title":"ASAIO J"},{"key":"10.1016\/j.jacep.2018.04.014_bib73","doi-asserted-by":"crossref","first-page":"2161","DOI":"10.1016\/j.athoracsur.2013.07.004","article-title":"Preoperative atrial fibrillation increases risk of thromboembolic events after left ventricular assist device implantation","volume":"96","author":"Stulak","year":"2013","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jacep.2018.04.014_bib74","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1056\/NEJMoa1707855","article-title":"Catheter ablation for atrial fibrillation with heart failure","volume":"378","author":"Marrouche","year":"2018","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.jacep.2018.04.014_bib75","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1007\/s10840-010-9476-6","article-title":"First experience of percutaneous radio-frequency ablation for atrial flutter and atrial fibrillation in a patient with HeartMate II left ventricular assist device","volume":"29","author":"Maury","year":"2010","journal-title":"J\u00a0Interv Card Electrophysiol"}],"container-title":["JACC: Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405500X18303785?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405500X18303785?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T07:25:49Z","timestamp":1762500349000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2405500X18303785"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7]]},"references-count":75,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2018,7]]}},"alternative-id":["S2405500X18303785"],"URL":"https:\/\/doi.org\/10.1016\/j.jacep.2018.04.014","relation":{},"ISSN":["2405-500X"],"issn-type":[{"value":"2405-500X","type":"print"}],"subject":[],"published":{"date-parts":[[2018,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Management of Arrhythmias and Cardiac Implantable Electronic Devices in Patients\u00a0With\u00a0Left Ventricular Assist Devices","name":"articletitle","label":"Article Title"},{"value":"JACC: Clinical Electrophysiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jacep.2018.04.014","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 by the American College of Cardiology Foundation. Published by Elsevier.","name":"copyright","label":"Copyright"}]}}