{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,18]],"date-time":"2026-07-18T19:57:10Z","timestamp":1784404630130,"version":"3.55.0"},"reference-count":32,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2021,1,27]],"date-time":"2021-01-27T00:00:00Z","timestamp":1611705600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100004374","name":"Medtronic","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004374","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100007497","name":"Biosense Webster","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007497","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jacc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JACC: Clinical Electrophysiology"],"published-print":{"date-parts":[[2021,3]]},"DOI":"10.1016\/j.jacep.2020.11.009","type":"journal-article","created":{"date-parts":[[2021,1,27]],"date-time":"2021-01-27T16:51:17Z","timestamp":1611766277000},"page":"352-363","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":51,"title":["A Novel Temperature-Controlled Radiofrequency Catheter Ablation System Used to Treat Patients With Paroxysmal Atrial Fibrillation"],"prefix":"10.1016","volume":"7","author":[{"given":"Josef","family":"Kautzner","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Paul","family":"Albenque","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Natale","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William","family":"Maddox","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frank","family":"Cuoco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Petr","family":"Neuzil","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Herve","family":"Poty","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael K.","family":"Getman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shufeng","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zdenek","family":"Starek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Srinivas R.","family":"Dukkipati","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"III","given":"B. Judson","family":"Colley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amin","family":"Al-Ahmad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Darren S.","family":"Sidney","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H. Thomas","family":"McElderry","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jacep.2020.11.009_bib1","doi-asserted-by":"crossref","first-page":"e275","DOI":"10.1016\/j.hrthm.2017.05.012","article-title":"2017 HRS\/EHRA\/ECAS\/APHRS\/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation","volume":"14","author":"Calkins","year":"2017","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2020.11.009_bib2","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1056\/NEJM199809033391003","article-title":"Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins","volume":"339","author":"Ha\u00efssaguerre","year":"1998","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.jacep.2020.11.009_bib3","doi-asserted-by":"crossref","first-page":"1812","DOI":"10.1056\/NEJMoa1408288","article-title":"Approaches to catheter ablation for persistent atrial fibrillation","volume":"372","author":"Verma","year":"2015","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.jacep.2020.11.009_bib4","doi-asserted-by":"crossref","first-page":"2368","DOI":"10.1161\/CIRCULATIONAHA.110.946806","article-title":"Long-term results of catheter ablation in paroxysmal atrial fibrillation: lessons from a 5-year follow-up","volume":"122","author":"Ouyang","year":"2010","journal-title":"Circulation"},{"key":"10.1016\/j.jacep.2020.11.009_bib5","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1161\/CIRCEP.113.000374","article-title":"Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: results from the EFFICAS I study","volume":"6","author":"Neuzil","year":"2013","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2020.11.009_bib6","doi-asserted-by":"crossref","first-page":"1229","DOI":"10.1093\/europace\/euv057","article-title":"EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation","volume":"17","author":"Kautzner","year":"2015","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2020.11.009_bib7","doi-asserted-by":"crossref","first-page":"1034","DOI":"10.1161\/01.CIR.82.3.1034","article-title":"Observations on electrode-tissue interface temperature and effect on electrical impedance during radiofrequency ablation of ventricular myocardium","volume":"82","author":"Haines","year":"1990","journal-title":"Circulation"},{"issue":"Suppl 12","key":"10.1016\/j.jacep.2020.11.009_bib8","first-page":"S431","article-title":"The past, the present, and the future of cardiac arrhythmia ablation","volume":"30","author":"Andrade","year":"2014","journal-title":"Can J Cardiol"},{"key":"10.1016\/j.jacep.2020.11.009_bib9","doi-asserted-by":"crossref","first-page":"2264","DOI":"10.1161\/01.CIR.91.8.2264","article-title":"Comparison of in\u00a0vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation","volume":"91","author":"Nakagawa","year":"1995","journal-title":"Circulation"},{"key":"10.1016\/j.jacep.2020.11.009_bib10","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1161\/CIRCULATIONAHA.105.540062","article-title":"Comparison of electrode cooling between internal and open irrigation in radiofrequency ablation lesion depth and incidence of thrombus and steam pop","volume":"113","author":"Yokoyama","year":"2006","journal-title":"Circulation"},{"key":"10.1016\/j.jacep.2020.11.009_bib11","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1016\/j.jacc.2017.06.008","article-title":"Temperature-controlled radiofrequency ablation for pulmonary vein isolation in patients with atrial fibrillation","volume":"70","author":"Iwasawa","year":"2017","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jacep.2020.11.009_bib12","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.hrthm.2011.08.021","article-title":"A\u00a0novel radiofrequency ablation catheter using contact force sensing: Toccata study","volume":"9","author":"Kuck","year":"2012","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2020.11.009_bib13","doi-asserted-by":"crossref","first-page":"1789","DOI":"10.1016\/j.hrthm.2012.07.016","article-title":"The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study","volume":"9","author":"Reddy","year":"2012","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2020.11.009_bib14","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1016\/j.ahj.2013.04.015","article-title":"Interpreting changes in quality of life in atrial fibrillation: how much change is meaningful?","volume":"166","author":"Dorian","year":"2013","journal-title":"Am Heart J"},{"key":"10.1016\/j.jacep.2020.11.009_bib15","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1001\/jama.2009.2029","article-title":"Comparison of antiarrhythmic drug therapy and radiofrequency catheter ablation in patients with paroxysmal atrial fibrillation: a randomized controlled trial","volume":"303","author":"Wilber","year":"2010","journal-title":"JAMA"},{"key":"10.1016\/j.jacep.2020.11.009_bib16","doi-asserted-by":"crossref","first-page":"1713","DOI":"10.1016\/j.jacc.2012.11.064","article-title":"Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: first results of the North American Arctic Front (STOP AF) pivotal trial","volume":"61","author":"Packer","year":"2013","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jacep.2020.11.009_bib17","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1161\/CIRCULATIONAHA.114.014092","volume":"132","author":"Reddy","year":"2015","journal-title":"Circulation"},{"key":"10.1016\/j.jacep.2020.11.009_bib19","doi-asserted-by":"crossref","first-page":"1350","DOI":"10.1016\/j.jacc.2015.07.036","article-title":"Pulmonary vein isolation using the visually guided laser balloon: a prospective, multicenter, and randomized comparison to standard radiofrequency ablation","volume":"66","author":"Dukkipati","year":"2015","journal-title":"J\u00a0Am Coll Cardiol"},{"issue":"Pt 1","key":"10.1016\/j.jacep.2020.11.009_bib20","doi-asserted-by":"crossref","first-page":"2899","DOI":"10.1111\/j.1540-8159.1997.tb05458.x","article-title":"The effects of electrode-tissue contact on radiofrequency lesion generation","volume":"20","author":"Avitall","year":"1997","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2020.11.009_bib21","first-page":"707","article-title":"Role of contact force sensing in catheter ablation of cardiac arrhythmias: evolution or history repeating itself?","volume":"4","author":"Ariyarathna","year":"2018","journal-title":"J\u00a0Am Coll Cardiol EP"},{"key":"10.1016\/j.jacep.2020.11.009_bib22","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1016\/j.ccep.2019.05.007","article-title":"Contact force and ablation index","volume":"11","author":"Virk","year":"2019","journal-title":"Card Electrophysiol Clin"},{"key":"10.1016\/j.jacep.2020.11.009_bib23","doi-asserted-by":"crossref","first-page":"994","DOI":"10.1111\/jce.13264","article-title":"Role of contact force-guided radiofrequency catheter ablation for treatment of atrial fibrillation: a systematic review and meta-analysis","volume":"28","author":"Lin","year":"2017","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2020.11.009_bib24","first-page":"1589","article-title":"Atrial fibrillation ablation with multipolar phased-radiofrequency catheter: the learning curve effect for procedural parameters, but not for the long-term outcome","volume":"8","author":"Glowniak","year":"2019","journal-title":"J\u00a0Clin Med"},{"key":"10.1016\/j.jacep.2020.11.009_bib25","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1111\/pace.12975","article-title":"Pulmonary vein isolation with the cryoballoon technique: feasibility, procedural outcomes, and adoption in the real world: data from One Shot Technologies TO Pulmonary Vein Isolation (1STOP) Project","volume":"40","author":"Padeletti","year":"2017","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2020.11.009_bib26","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1093\/europace\/euv186","article-title":"Use of a contact force-sensing ablation catheter with advanced catheter location significantly reduces fluoroscopy time and radiation dose in catheter ablation of atrial fibrillation","volume":"18","author":"Lee","year":"2016","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2020.11.009_bib27","doi-asserted-by":"crossref","first-page":"968","DOI":"10.1002\/clc.23391","article-title":"Procedural outcomes and learning curve of cardiac arrhythmias catheter ablation using remote magnetic navigation: experience from a large-scale single-center study","volume":"43","author":"Li","year":"2020","journal-title":"Clin Cardiol"},{"key":"10.1016\/j.jacep.2020.11.009_bib28","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1093\/europace\/eul100","article-title":"The effectiveness of a high output\/short duration radiofrequency current application technique in segmental pulmonary vein isolation for atrial fibrillation","volume":"8","author":"Nilsson","year":"2006","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2020.11.009_bib29","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1016\/j.hrthm.2018.11.031","article-title":"Low complication rates using high power (45-50\u00a0W) for short duration for atrial fibrillation ablations","volume":"16","author":"Winkle","year":"2019","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2020.11.009_bib30","first-page":"874","article-title":"Five seconds of 50-60\u00a0W radio frequency atrial ablations were transmural and safe: an in\u00a0vitro mechanistic assessment and force-controlled in\u00a0vivo validation","volume":"19","author":"Bhaskaran","year":"2017","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2020.11.009_bib31","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1111\/jce.13363","article-title":"Thermal latency adds to lesion depth after application of high-power short-duration radiofrequency energy:\u00a0Results of a computer-modeling study","volume":"29","author":"Irastorza","year":"2018","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2020.11.009_bib32","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1001\/jama.2019.0693","article-title":"Effect of catheter ablation vs antiarrhythmic drug therapy on mortality, stroke, bleeding, and cardiac arrest among patients with atrial fibrillation: the CABANA Randomized Clinical Trial","volume":"321","author":"Packer","year":"2019","journal-title":"JAMA"},{"key":"10.1016\/j.jacep.2020.11.009_bib33","doi-asserted-by":"crossref","first-page":"2254","DOI":"10.1016\/j.jacc.2019.08.1036","article-title":"Risk of mortality following catheter ablation of atrial fibrillation [published correction appears in J Am Coll Cardiol 2020;75:1093","volume":"74","author":"Cheng","year":"2019","journal-title":"J\u00a0Am Coll Cardiol"}],"container-title":["JACC: Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405500X20311907?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405500X20311907?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T07:29:40Z","timestamp":1762500580000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2405500X20311907"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3]]},"references-count":32,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021,3]]}},"alternative-id":["S2405500X20311907"],"URL":"https:\/\/doi.org\/10.1016\/j.jacep.2020.11.009","relation":{},"ISSN":["2405-500X"],"issn-type":[{"value":"2405-500X","type":"print"}],"subject":[],"published":{"date-parts":[[2021,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A Novel Temperature-Controlled Radiofrequency Catheter Ablation System Used to Treat Patients With Paroxysmal Atrial Fibrillation","name":"articletitle","label":"Article Title"},{"value":"JACC: Clinical Electrophysiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jacep.2020.11.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.","name":"copyright","label":"Copyright"}]}}