{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T22:21:36Z","timestamp":1790720496496,"version":"4.1.0"},"reference-count":29,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2023,3,1]],"date-time":"2023-03-01T00:00:00Z","timestamp":1677628800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,3,1]],"date-time":"2023-03-01T00:00:00Z","timestamp":1677628800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T00:00:00Z","timestamp":1709251200000},"content-version":"vor","delay-in-days":366,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100007497","name":"Biosense Webster","doi-asserted-by":"publisher","award":["IIS-484"],"award-info":[{"award-number":["IIS-484"]}],"id":[{"id":"10.13039\/100007497","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100001316","name":"Abbott Laboratories","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100001316","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jacc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JACC: Clinical Electrophysiology"],"published-print":{"date-parts":[[2023,3]]},"DOI":"10.1016\/j.jacep.2022.10.001","type":"journal-article","created":{"date-parts":[[2022,10,10]],"date-time":"2022-10-10T10:48:21Z","timestamp":1665398901000},"page":"330-340","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":7,"title":["Radiofrequency Ablation of the Diseased\u00a0Human Left Ventricle"],"prefix":"10.1016","volume":"9","author":[{"given":"Alexander P.","family":"Bates","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Paisey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arthur","family":"Yue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Phil","family":"Banks","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul R.","family":"Roberts","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Waqas","family":"Ullah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"12 pt 1","key":"10.1016\/j.jacep.2022.10.001_bib1","doi-asserted-by":"crossref","first-page":"2899","DOI":"10.1111\/j.1540-8159.1997.tb05458.x","article-title":"The effects of electrode-tissue contact on radiofrequency lesion generation","volume":"20","author":"Avitall","year":"1997","journal-title":"Pacing Clin Electrophysiol"},{"issue":"6","key":"10.1016\/j.jacep.2022.10.001_bib2","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1111\/j.1540-8167.1991.tb01353.x","article-title":"Determinants of lesion size during radiofrequency catheter ablation: the role of electrode-tissue contact pressure and duration of energy delivery","volume":"2","author":"Haines","year":"1991","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"issue":"6","key":"10.1016\/j.jacep.2022.10.001_bib3","doi-asserted-by":"crossref","first-page":"1174","DOI":"10.1161\/CIRCEP.113.001094","volume":"7","author":"Ikeda","year":"2014","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"7","key":"10.1016\/j.jacep.2022.10.001_bib4","first-page":"902","article-title":"Longer duration versus increasing power during radiofrequency ablation yields different ablation lesion characteristics","volume":"4","author":"Borne","year":"2018","journal-title":"J\u00a0Am Coll Cardiol EP"},{"issue":"6","key":"10.1016\/j.jacep.2022.10.001_bib5","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1111\/j.1540-8159.1989.tb05034.x","article-title":"Tissue heating during radiofrequency catheter ablation: a thermodynamic model and observations in isolated perfused and superfused canine right ventricular free wall","volume":"12","author":"Haines","year":"1989","journal-title":"Pacing Clin Electrophysiol"},{"issue":"9","key":"10.1016\/j.jacep.2022.10.001_bib6","doi-asserted-by":"crossref","first-page":"1038","DOI":"10.1111\/j.1540-8167.2010.01750.x","article-title":"Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in\u00a0vitro contractile model","volume":"21","author":"Shah","year":"2010","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"issue":"suppl 22","key":"10.1016\/j.jacep.2022.10.001_bib7","article-title":"Abstract 12104: prospective study using a new formula incorporating contact force, radiofrequency power and application time (force-power-time index) for quantifying lesion formation to guide long continuous atrial lesions in the beating canine heart","volume":"128","author":"Nakagawa","year":"2013","journal-title":"Circulation"},{"issue":"5","key":"10.1016\/j.jacep.2022.10.001_bib8","doi-asserted-by":"crossref","first-page":"S475","DOI":"10.1016\/j.hrthm.2022.03.1122","article-title":"Prospective study to test the ability to create RF lesions at predicted depths of 3, 5, 7 and 9\u00a0mm using a new formula incorporating contact force, radiofrequency power and application time (force-power-time index) in the beating canine heart","volume":"10","author":"Nakagawa","year":"2013","journal-title":"Heart Rhythm"},{"issue":"7","key":"10.1016\/j.jacep.2022.10.001_bib9","doi-asserted-by":"crossref","first-page":"1042","DOI":"10.1093\/europace\/euab004","article-title":"Local catheter impedance drop during pulmonary vein isolation predicts acute conduction block in patients with paroxysmal atrial fibrillation: initial results of the LOCALIZE clinical trial","volume":"23","author":"Das","year":"2021","journal-title":"EP Europace"},{"issue":"8","key":"10.1016\/j.jacep.2022.10.001_bib10","doi-asserted-by":"crossref","first-page":"1229","DOI":"10.1093\/europace\/euv057","article-title":"EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation","volume":"17","author":"Kautzner","year":"2015","journal-title":"Europace"},{"issue":"1","key":"10.1016\/j.jacep.2022.10.001_bib11","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1161\/CIRCEP.113.001137","article-title":"Target indices for clinical ablation in atrial fibrillation: insights from contact force, electrogram, and biophysical parameter analysis","volume":"7","author":"Ullah","year":"2014","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"10","key":"10.1016\/j.jacep.2022.10.001_bib12","first-page":"1080","article-title":"Ablation index and surround flow catheter irrigation: impedance-based appraisal in clinical ablation","volume":"3","author":"Ullah","year":"2017","journal-title":"J\u00a0Am Coll Cardiol EP"},{"issue":"8","key":"10.1016\/j.jacep.2022.10.001_bib13","first-page":"920","article-title":"Histopathological characterization of radiofrequency ablation in ventricular scar tissue","volume":"5","author":"Barkagan","year":"2019","journal-title":"J\u00a0Am Coll Cardiol EP"},{"issue":"12","key":"10.1016\/j.jacep.2022.10.001_bib14","doi-asserted-by":"crossref","first-page":"1919","DOI":"10.1093\/europace\/euz247","article-title":"Radiofrequency ablation lesions in low-, intermediate-, and normal-voltage myocardium: an in\u00a0vivo study in a porcine heart model","volume":"21","author":"Tofig","year":"2019","journal-title":"Europace"},{"issue":"5","key":"10.1016\/j.jacep.2022.10.001_bib15","doi-asserted-by":"crossref","first-page":"S26","DOI":"10.1016\/j.hrthm.2022.03.605","article-title":"CA-530-04 Utility of ablation index for guiding ablation in ventricular tissue","volume":"19","author":"Zilberman","year":"2022","journal-title":"Heart Rhythm"},{"issue":"2","key":"10.1016\/j.jacep.2022.10.001_bib16","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1111\/jce.12542","article-title":"Factors affecting catheter contact in the human left atrium and their impact on ablation efficacy","volume":"26","author":"Ullah","year":"2015","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"issue":"11","key":"10.1016\/j.jacep.2022.10.001_bib17","doi-asserted-by":"crossref","first-page":"1262","DOI":"10.1111\/j.1540-8167.2009.01538.x","article-title":"Effect of electrode orientation on lesion sizes produced by irrigated radiofrequency ablation catheters","volume":"20","author":"Wood","year":"2009","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"issue":"4","key":"10.1016\/j.jacep.2022.10.001_bib18","first-page":"636","article-title":"Relationship between the ablation index, lesion formation, and incidence of steam pops","volume":"35","author":"Mori","year":"2019","journal-title":"J\u00a0Arrhythm"},{"issue":"4","key":"10.1016\/j.jacep.2022.10.001_bib19","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1111\/jce.15379","article-title":"Comparison of ablation index versus time-guided radiofrequency energy dosing using normal and half-normal saline irrigation in a porcine left ventricular model","volume":"33","author":"Larsen","year":"2022","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"issue":"3","key":"10.1016\/j.jacep.2022.10.001_bib20","doi-asserted-by":"crossref","first-page":"1034","DOI":"10.1161\/01.CIR.82.3.1034","article-title":"Observations on electrode-tissue interface temperature and effect on electrical impedance during radiofrequency ablation of ventricular myocardium","volume":"82","author":"Haines","year":"1990","journal-title":"Circulation"},{"issue":"1","key":"10.1016\/j.jacep.2022.10.001_bib21","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1093\/europace\/euaa228","article-title":"Prospective use of ablation index for the ablation of right ventricle outflow tract premature ventricular contractions: a proof of concept study","volume":"23","author":"Gasperetti","year":"2020","journal-title":"Europace"},{"issue":"6","key":"10.1016\/j.jacep.2022.10.001_bib22","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1016\/j.hrthm.2019.01.005","article-title":"Ablation Index as a predictor of long-term efficacy in premature ventricular complex ablation: a regional target value analysis","volume":"16","author":"Casella","year":"2019","journal-title":"Heart Rhythm"},{"issue":"4","key":"10.1016\/j.jacep.2022.10.001_bib23","first-page":"465","article-title":"Utility of prolonged duration endocardial ablation for ventricular arrhythmias originating from the left ventricular summit","volume":"8","author":"Garg","year":"2022","journal-title":"J\u00a0Am Coll Cardiol EP"},{"issue":"5","key":"10.1016\/j.jacep.2022.10.001_bib24","first-page":"775","article-title":"Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values","volume":"19","author":"Das","year":"2017","journal-title":"Europace"},{"issue":"9","key":"10.1016\/j.jacep.2022.10.001_bib25","doi-asserted-by":"crossref","first-page":"1037","DOI":"10.1111\/jce.13281","article-title":"Prospective use of Ablation Index targets improves clinical outcomes following ablation for atrial fibrillation","volume":"28","author":"Hussein","year":"2017","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"issue":"6","key":"10.1016\/j.jacep.2022.10.001_bib26","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1093\/europace\/euu329","article-title":"Low contact force and force-time integral predict early recovery and dormant conduction revealed by adenosine after pulmonary vein isolation","volume":"17","author":"le Polain de Waroux","year":"2015","journal-title":"Europace"},{"issue":"7","key":"10.1016\/j.jacep.2022.10.001_bib27","doi-asserted-by":"crossref","first-page":"933","DOI":"10.1111\/j.1540-8159.2004.00561.x","article-title":"Ablation lesion size correlates with pacing threshold: a physiological basis for use of pacing to assess ablation lesions","volume":"27","author":"Sapp","year":"2004","journal-title":"Pacing Clin Electrophysiol"},{"issue":"10","key":"10.1016\/j.jacep.2022.10.001_bib28","doi-asserted-by":"crossref","first-page":"1993","DOI":"10.1046\/j.1460-9592.2003.00307.x","article-title":"Assessment of radiofrequency ablation effect from unipolar pacing threshold","volume":"26","author":"Delacretaz","year":"2003","journal-title":"Pacing Clin Electrophysiol"},{"issue":"1","key":"10.1016\/j.jacep.2022.10.001_bib29","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1161\/CIRCEP.110.959957","article-title":"Endocardial unipolar voltage mapping to detect epicardial ventricular tachycardia substrate in patients with nonischemic left ventricular cardiomyopathy","volume":"4","author":"Hutchinson","year":"2011","journal-title":"Circ Arrhythm Electrophysiol"}],"container-title":["JACC: Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405500X22008477?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405500X22008477?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T07:31:57Z","timestamp":1762500717000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2405500X22008477"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3]]},"references-count":29,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2023,3]]}},"alternative-id":["S2405500X22008477"],"URL":"https:\/\/doi.org\/10.1016\/j.jacep.2022.10.001","relation":{},"ISSN":["2405-500X"],"issn-type":[{"value":"2405-500X","type":"print"}],"subject":[],"published":{"date-parts":[[2023,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Radiofrequency Ablation of the Diseased\u00a0Human Left Ventricle","name":"articletitle","label":"Article Title"},{"value":"JACC: Clinical Electrophysiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jacep.2022.10.001","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 by the American College of Cardiology Foundation. Published by Elsevier.","name":"copyright","label":"Copyright"}]}}