{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T19:30:58Z","timestamp":1769974258425,"version":"3.49.0"},"reference-count":35,"publisher":"Elsevier BV","issue":"12","license":[{"start":{"date-parts":[[2023,12,1]],"date-time":"2023-12-01T00:00:00Z","timestamp":1701388800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,12,1]],"date-time":"2023-12-01T00:00:00Z","timestamp":1701388800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"vor","delay-in-days":366,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100007497","name":"Biosense Webster Inc","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007497","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jacc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JACC: Clinical Electrophysiology"],"published-print":{"date-parts":[[2023,12]]},"DOI":"10.1016\/j.jacep.2023.08.005","type":"journal-article","created":{"date-parts":[[2023,10,4]],"date-time":"2023-10-04T14:40:35Z","timestamp":1696430435000},"page":"2573-2583","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":10,"title":["50-W vs 40-W During High-Power Short-Duration Ablation for\u00a0Paroxysmal\u00a0Atrial Fibrillation"],"prefix":"10.1016","volume":"9","author":[{"given":"Alexandru","family":"Costea","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0887-1700","authenticated-orcid":false,"given":"Juan Carlos","family":"Diaz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jose","family":"Osorio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3228-7435","authenticated-orcid":false,"given":"Carlos D.","family":"Matos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3973-9828","authenticated-orcid":false,"given":"Carolina","family":"Hoyos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6915-9835","authenticated-orcid":false,"given":"Sandeep","family":"Goyal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charles","family":"Te","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Benjamin","family":"D\u2019Souza","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohit","family":"Rastogi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nestor","family":"Lopez-Cabanillas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laura C.","family":"Ibanez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher","family":"Thorne","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Allyson L.","family":"Varley","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul C.","family":"Zei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William H.","family":"Sauer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jorge E.","family":"Romero","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jacep.2023.08.005_bib1","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1001\/jama.2009.2029","article-title":"Comparison of antiarrhythmic drug therapy and radiofrequency catheter ablation in patients with paroxysmal atrial fibrillation: a randomized controlled trial","volume":"303","author":"Wilber","year":"2010","journal-title":"JAMA"},{"key":"10.1016\/j.jacep.2023.08.005_bib2","doi-asserted-by":"crossref","first-page":"1275","DOI":"10.1001\/jama.2019.0692","article-title":"Effect of Catheter Ablation vs Medical Therapy on Quality of Life Among Patients With Atrial Fibrillation: the CABANA randomized clinical trial","volume":"321","author":"Mark","year":"2019","journal-title":"JAMA"},{"key":"10.1016\/j.jacep.2023.08.005_bib3","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1001\/jama.2019.0693","article-title":"Effect of Catheter Ablation vs Antiarrhythmic Drug Therapy on Mortality, Stroke, Bleeding, and Cardiac Arrest Among Patients With Atrial Fibrillation: the CABANA randomized clinical trial","volume":"321","author":"Packer","year":"2019","journal-title":"JAMA"},{"key":"10.1016\/j.jacep.2023.08.005_bib4","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1001\/jamacardio.2021.0852","article-title":"Assessment of catheter ablation or antiarrhythmic drugs for first-line therapy of atrial fibrillation: a meta-analysis of randomized clinical trials","volume":"6","author":"Turagam","year":"2021","journal-title":"JAMA Cardiol"},{"key":"10.1016\/j.jacep.2023.08.005_bib5","doi-asserted-by":"crossref","first-page":"854","DOI":"10.1111\/jce.13484","article-title":"Temporal trends in safety and complication rates of catheter ablation for atrial fibrillation","volume":"29","author":"Muthalaly","year":"2018","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2023.08.005_bib6","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1111\/j.1540-8167.2008.01355.x","article-title":"Relationship between catheter forces, lesion characteristics, \"popping,\" and char formation: experience with robotic navigation system","volume":"20","author":"Biase","year":"2008","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2023.08.005_bib7","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1111\/jce.15282","article-title":"Actual tissue temperature during ablation index-guided high-power short-duration ablation versus standard ablation: Implications in terms of the efficacy and safety of atrial fibrillation ablation","volume":"33","author":"Otsuka","year":"2022","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2023.08.005_bib8","first-page":"467","article-title":"High-power and short-duration ablation for pulmonary vein isolation: biophysical characterization","volume":"4","author":"Leshem","year":"2018","journal-title":"J\u00a0Am Coll Cardiol EP"},{"key":"10.1016\/j.jacep.2023.08.005_bib9","first-page":"295","article-title":"Pulmonary vein reconnection no longer occurs in the majority of patients after a single pulmonary vein isolation procedure","volume":"5","author":"De Pooter","year":"2019","journal-title":"J\u00a0Am Coll Cardiol EP"},{"key":"10.1016\/j.jacep.2023.08.005_bib10","doi-asserted-by":"crossref","first-page":"f419","DOI":"10.1093\/europace\/eux376","article-title":"Improving procedural and one-year outcome after contact force-guided pulmonary vein isolation: the role of interlesion distance, ablation index, and contact force variability in the 'CLOSE'-protocol","volume":"20","author":"Phlips","year":"2018","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2023.08.005_bib11","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1016\/j.hrthm.2016.11.009","article-title":"Durability of wide-area left atrial appendage isolation: results from extensive catheter ablation for treatment of persistent atrial fibrillation","volume":"14","author":"Reissmann","year":"2017","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2023.08.005_bib12","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1007\/s10840-022-01205-0","article-title":"Practice patterns of operators participating in the Real-World Experience of Catheter Ablation for Treatment of Symptomatic Paroxysmal and Persistent Atrial Fibrillation (REAL-AF) Registry","volume":"65","author":"Kreidieh","year":"2022","journal-title":"J\u00a0Interv Card Electrophysiol"},{"key":"10.1016\/j.jacep.2023.08.005_bib13","doi-asserted-by":"crossref","first-page":"2751","DOI":"10.1111\/jce.14223","article-title":"High-power application is associated with shorter procedure time and higher rate of first-pass pulmonary vein isolation in ablation index-guided atrial fibrillation ablation","volume":"30","author":"Okamatsu","year":"2019","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"issue":"5","key":"10.1016\/j.jacep.2023.08.005_bib14","first-page":"611","article-title":"A\u00a0randomized trial of high vs standard power radiofrequency ablation for pulmonary vein isolation: SHORT-AF","volume":"9","author":"Lee","year":"2023","journal-title":"J\u00a0Am Coll Cardiol EP"},{"key":"10.1016\/j.jacep.2023.08.005_bib15","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1080\/00015385.2021.1939512","article-title":"Meta-analysis of high power short duration in atrial fibrillation ablation - a superior efficient ablation strategy","volume":"77","author":"Xu","year":"2022","journal-title":"Acta Cardiol"},{"key":"10.1016\/j.jacep.2023.08.005_bib16","doi-asserted-by":"crossref","first-page":"710","DOI":"10.1093\/europace\/euaa327","article-title":"High-power short duration vs. conventional radiofrequency ablation of atrial fibrillation: a systematic review and meta-analysis","volume":"23","author":"Ravi","year":"2021","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2023.08.005_bib17","doi-asserted-by":"crossref","first-page":"2408","DOI":"10.1111\/jce.15158","article-title":"Procedural efficacy and safety of standardized, ablation index guided fixed 50\u00a0W high-power short-duration pulmonary vein isolation and substrate modification using the CLOSE protocol","volume":"32","author":"Francke","year":"2021","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2023.08.005_bib18","first-page":"778","article-title":"pulmonary vein isolation with very high power, short duration, temperature-controlled lesions: the QDOT-FAST trial","volume":"5","author":"Reddy","year":"2019","journal-title":"J\u00a0Am Coll Cardiol EP"},{"key":"10.1016\/j.jacep.2023.08.005_bib19","doi-asserted-by":"crossref","first-page":"1219","DOI":"10.1111\/jce.14989","article-title":"High-power, short-duration atrial fibrillation ablation compared with a conventional approach: outcomes and reconnection patterns","volume":"32","author":"Hansom","year":"2021","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"issue":"3","key":"10.1016\/j.jacep.2023.08.005_bib20","first-page":"367","article-title":"Very high-power ablation for contiguous pulmonary vein isolation: results from the randomized POWER PLUS trial","volume":"8","author":"O'Neill","year":"2022","journal-title":"J\u00a0Am Coll Cardiol EP"},{"issue":"9","key":"10.1016\/j.jacep.2023.08.005_bib21","first-page":"1077","article-title":"Very high-power short-duration, temperature-controlled radiofrequency ablation in paroxysmal atrial fibrillation: the prospective multicenter Q-FFICIENCY trial","volume":"8","author":"Osorio","year":"2022","journal-title":"J\u00a0Am Coll Cardiol EP"},{"key":"10.1016\/j.jacep.2023.08.005_bib22","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1111\/jce.15782","article-title":"In\u00a0vivo tissue temperatures during 90 W\/4 sec-very high power-short-duration (vHPSD) ablation versus ablation index-guided 50 W-HPSD ablation: a porcine study","volume":"34","author":"Otsuka","year":"2022","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"issue":"3","key":"10.1016\/j.jacep.2023.08.005_bib23","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1007\/s10840-021-01031-w","article-title":"A\u00a0prospective multi-site registry of real-world experience of catheter ablation for treatment of symptomatic paroxysmal and persistent atrial fibrillation (REAL-AF): design and objectives","volume":"62","author":"Varley","year":"2021","journal-title":"J\u00a0Interv Card Electrophysiol"},{"issue":"3","key":"10.1016\/j.jacep.2023.08.005_bib24","doi-asserted-by":"crossref","first-page":"880","DOI":"10.1093\/europace\/euac243","article-title":"Very high-power short-duration ablation for pulmonary vein isolation utilizing a very-close protocol-the FAST AND FURIOUS PVI study","volume":"25","author":"Heeger","year":"2023","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2023.08.005_bib25","doi-asserted-by":"crossref","first-page":"1814","DOI":"10.1111\/jce.15028","article-title":"Predictors of clinical success after paroxysmal atrial fibrillation catheter ablation","volume":"32","author":"Osorio","year":"2021","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2023.08.005_bib26","first-page":"321","article-title":"Improved procedural efficiency of atrial fibrillation ablation using a dedicated ablation protocol and lean management","volume":"7","author":"Berte","year":"2021","journal-title":"J\u00a0Am Coll Cardiol EP"},{"key":"10.1016\/j.jacep.2023.08.005_bib27","doi-asserted-by":"crossref","first-page":"1763","DOI":"10.1093\/europace\/euac048","article-title":"Process optimization for atrial fibrillation ablation","volume":"24","author":"Boehmer","year":"2022","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2023.08.005_bib28","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1093\/europace\/euac215","article-title":"Safety profile and long-term efficacy of very high-power short-duration (60-70 W) catheter ablation for atrial fibrillation: results of a large comparative analysis","volume":"25","author":"Popa","year":"2022","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2023.08.005_bib29","doi-asserted-by":"crossref","first-page":"2528","DOI":"10.1111\/jce.15676","article-title":"Characterization of high-power and very-high-power short-duration radiofrequency lesions performed with a new-generation catheter and a temperature-control ablation mode","volume":"33","author":"Lozano-Granero","year":"2022","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2023.08.005_bib30","first-page":"899","article-title":"High-power, short-duration ablation during Box isolation for atrial fibrillation","volume":"36","author":"Kumagai","year":"2020","journal-title":"J\u00a0Arrhythm"},{"key":"10.1016\/j.jacep.2023.08.005_bib31","doi-asserted-by":"crossref","first-page":"1465","DOI":"10.1007\/s10840-022-01449-w","article-title":"Optimal prevention method of phrenic nerve injury in superior vena cava isolation: efficacy of high-power, short-duration radiofrequency energy application on the risk points","volume":"66","author":"Yamaji","year":"2023","journal-title":"J\u00a0Interv Card Electrophysiol"},{"key":"10.1016\/j.jacep.2023.08.005_bib32","first-page":"26","article-title":"Comparison of microemboli formation between irrigated catheter tip architecture using a microemboli monitoring system","volume":"8","author":"Konishi","year":"2022","journal-title":"J\u00a0Am Coll Cardiol EP"},{"key":"10.1016\/j.jacep.2023.08.005_bib33","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.115.003226","article-title":"Effect of left atrial ablation process and strategy on microemboli formation during irrigated radiofrequency catheter ablation in an in\u00a0vivo model","volume":"9","author":"Takami","year":"2016","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2023.08.005_bib35","doi-asserted-by":"crossref","first-page":"2942","DOI":"10.1093\/eurheartj\/ehy176","article-title":"Apixaban in patients at risk of stroke undergoing atrial fibrillation ablation","volume":"39","author":"Kirchhof","year":"2018","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jacep.2023.08.005_bib36","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1016\/j.hrcr.2021.09.012","article-title":"Radiofrequency ablation data associated with atrioesophageal fistula","volume":"7","author":"Tomlinson","year":"2021","journal-title":"HeartRhythm Case Rep"}],"container-title":["JACC: Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405500X23006187?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405500X23006187?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T07:33:44Z","timestamp":1762500824000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2405500X23006187"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12]]},"references-count":35,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2023,12]]}},"alternative-id":["S2405500X23006187"],"URL":"https:\/\/doi.org\/10.1016\/j.jacep.2023.08.005","relation":{},"ISSN":["2405-500X"],"issn-type":[{"value":"2405-500X","type":"print"}],"subject":[],"published":{"date-parts":[[2023,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"50-W vs 40-W During High-Power Short-Duration Ablation for\u00a0Paroxysmal\u00a0Atrial Fibrillation","name":"articletitle","label":"Article Title"},{"value":"JACC: Clinical Electrophysiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jacep.2023.08.005","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 by the American College of Cardiology Foundation. Published by Elsevier.","name":"copyright","label":"Copyright"}]}}