{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T09:06:43Z","timestamp":1793524003635,"version":"4.5.0"},"reference-count":17,"publisher":"Elsevier BV","issue":"10","license":[{"start":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T00:00:00Z","timestamp":1759276800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T00:00:00Z","timestamp":1759276800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"vor","delay-in-days":365,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100000002","name":"NIH","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jacc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JACC: Clinical Electrophysiology"],"published-print":{"date-parts":[[2025,10]]},"DOI":"10.1016\/j.jacep.2025.05.021","type":"journal-article","created":{"date-parts":[[2025,7,23]],"date-time":"2025-07-23T18:39:26Z","timestamp":1753295966000},"page":"2190-2201","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":8,"title":["Esophageal Heating and Damage With High-Power-Short-Duration Radiofrequency and Pulsed Field Ablation"],"prefix":"10.1016","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7937-4686","authenticated-orcid":false,"given":"Armen A.","family":"Kocharian","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9678-7474","authenticated-orcid":false,"given":"Adi","family":"Lador","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sufen","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul A.","family":"Schurmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amish S.","family":"Dave","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas E.","family":"Hong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qi","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jennifer","family":"Maffre","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tushar","family":"Sharma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andres","family":"Altmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher","family":"Beeckler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miguel","family":"Valderr\u00e1bano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jacep.2025.05.021_bib1","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.121.010663","article-title":"90 vs 50-Watt radiofrequency applications for pulmonary vein isolation: experimental and clinical findings","volume":"15","author":"Bortone","year":"2022","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2025.05.021_bib2","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1111\/jce.13651","article-title":"High-power and short-duration ablation for pulmonary vein isolation: safety, efficacy, and long-term durability","volume":"29","author":"Barkagan","year":"2018","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2025.05.021_bib3","doi-asserted-by":"crossref","first-page":"652","DOI":"10.1016\/j.jacep.2023.01.022","article-title":"PV Isolation using a spherical array PFA catheter: preclinical assessment and comparison to radiofrequency ablation","volume":"9","author":"Koruth","year":"2023","journal-title":"JACC Clin Electrophysiol"},{"issue":"18","key":"10.1016\/j.jacep.2025.05.021_bib4","doi-asserted-by":"crossref","first-page":"1660","DOI":"10.1056\/NEJMoa2307291","article-title":"Pulsed field or conventional thermal ablation for paroxysmal atrial fibrillation","volume":"389","author":"Reddy","year":"2023","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jacep.2025.05.021_bib5","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.120.008716","article-title":"Focal pulsed field ablation for pulmonary vein isolation and linear atrial lesions: a preclinical assessment of safety and durability","volume":"13","author":"Koruth","year":"2020","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2025.05.021_bib6","first-page":"385","article-title":"Incidence of asymptomatic oesophageal lesions after atrial fibrillation ablation using an oesophageal temperature probe with insulated thermocouples: a comparative controlled study","volume":"19","author":"Halbfass","year":"2017","journal-title":"Europace"},{"key":"10.1016\/j.jacep.2025.05.021_bib7","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1016\/j.jacep.2017.11.018","article-title":"High-power and short-duration ablation for pulmonary vein isolation: biophysical characterization","volume":"4","author":"Leshem","year":"2018","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.jacep.2025.05.021_bib8","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.121.010205","article-title":"Impact of high-power short-duration radiofrequency ablation on esophageal temperature dynamic","volume":"14","author":"Yavin","year":"2021","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2025.05.021_bib9","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1016\/j.hrthm.2020.01.014","article-title":"Esophageal temperature dynamics during high-power short-duration posterior wall ablation","volume":"17","author":"Barbhaiya","year":"2020","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.jacep.2025.05.021_bib10","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1111\/jce.14883","article-title":"Incidence of ablation-induced esophageal injury associated with high-power short duration temperature-controlled pulmonary vein isolation using a specialized open-irrigated ablation catheter: a retrospective single-center study","volume":"32","author":"Piringer","year":"2021","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2025.05.021_bib11","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1111\/jce.15782","article-title":"In vivo tissue temperatures during 90 W\/4 sec-very high power-short-duration (vHPSD) ablation versus ablation index-guided 50 W-HPSD ablation: a porcine study","volume":"34","author":"Otsuka","year":"2023","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.jacep.2025.05.021_bib12","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.120.009229","article-title":"Circular multielectrode pulsed field ablation catheter lasso pulsed field ablation: lesion characteristics, durability, and effect on neighboring structures","volume":"14","author":"Yavin","year":"2021","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2025.05.021_bib13","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.120.008580","article-title":"Pulsed field ablation using a lattice electrode for focal energy delivery: biophysical characterization, lesion durability, and safety evaluation","volume":"13","author":"Yavin","year":"2020","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2025.05.021_bib14","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.119.008303","article-title":"Pulsed field ablation versus radiofrequency ablation: esophageal injury in a novel porcine model","volume":"13","author":"Koruth","year":"2020","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2025.05.021_bib15","doi-asserted-by":"crossref","first-page":"1369","DOI":"10.1093\/europace\/euad030","article-title":"Preclinical assessment of the feasibility, safety and lesion durability of a novel 'single-shot' pulsed field ablation catheter for pulmonary vein isolation","volume":"25","author":"Koruth","year":"2023","journal-title":"Europace"},{"issue":"5","key":"10.1016\/j.jacep.2025.05.021_bib16","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.116.004672","article-title":"Acute and long-term effects of full-power electroporation ablation directly on the porcine esophagus","volume":"10","author":"Neven","year":"2017","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.jacep.2025.05.021_bib17","doi-asserted-by":"crossref","first-page":"2203","DOI":"10.1111\/jce.16010","article-title":"Preclinical evaluation of a novel single-shot pulsed field ablation system for pulmonary vein and atrial ablation","volume":"34","author":"Aryana","year":"2023","journal-title":"J Cardiovasc Electrophysiol"}],"container-title":["JACC: Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405500X25004463?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405500X25004463?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T03:57:34Z","timestamp":1790827054000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2405500X25004463"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10]]},"references-count":17,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2025,10]]}},"alternative-id":["S2405500X25004463"],"URL":"https:\/\/doi.org\/10.1016\/j.jacep.2025.05.021","relation":{},"ISSN":["2405-500X"],"issn-type":[{"value":"2405-500X","type":"print"}],"subject":[],"published":{"date-parts":[[2025,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Esophageal Heating and Damage With High-Power-Short-Duration Radiofrequency and Pulsed Field Ablation","name":"articletitle","label":"Article Title"},{"value":"JACC: Clinical Electrophysiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jacep.2025.05.021","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 by the American College of Cardiology Foundation. Published by Elsevier.","name":"copyright","label":"Copyright"}]}}