{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T06:23:19Z","timestamp":1790749399419,"version":"4.1.0"},"reference-count":37,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2011,2,1]],"date-time":"2011-02-01T00:00:00Z","timestamp":1296518400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2011,2,1]],"date-time":"2011-02-01T00:00:00Z","timestamp":1296518400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2011,2,1]],"date-time":"2011-02-01T00:00:00Z","timestamp":1296518400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2011,2,1]],"date-time":"2011-02-01T00:00:00Z","timestamp":1296518400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2011,2,1]],"date-time":"2011-02-01T00:00:00Z","timestamp":1296518400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2011,2,1]],"date-time":"2011-02-01T00:00:00Z","timestamp":1296518400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2011,2,1]],"date-time":"2011-02-01T00:00:00Z","timestamp":1296518400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Biomechanics"],"published-print":{"date-parts":[[2011,2]]},"DOI":"10.1016\/j.jbiomech.2010.09.034","type":"journal-article","created":{"date-parts":[[2010,10,28]],"date-time":"2010-10-28T04:17:04Z","timestamp":1288239424000},"page":"461-466","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":35,"title":["Does the personal lift-assist device affect the local dynamic stability of the spine during lifting?"],"prefix":"10.1016","volume":"44","author":[{"given":"Ryan B.","family":"Graham","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erin M.","family":"Sadler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joan M.","family":"Stevenson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jbiomech.2010.09.034_bib1","doi-asserted-by":"crossref","first-page":"1331","DOI":"10.1103\/RevModPhys.65.1331","article-title":"The analysis of observed data in physical systems","volume":"65","author":"Abarbanel","year":"1993","journal-title":"Reviews of Modern Physics"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib2","unstructured":"Abdoli-E, M., 2005. Design and instrumentation of a mechanical personal lift augmentation device (PLAD) for manual lifting tasks. Ph.D. Thesis, Queen\u2019s University."},{"key":"10.1016\/j.jbiomech.2010.09.034_bib3","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1016\/j.clinbiomech.2005.12.021","article-title":"An on-body personal lift augmentation device (PLAD) reduces EMG amplitude of erector spinae during lifting tasks","volume":"21","author":"Abdoli-E","year":"2006","journal-title":"Clinical Biomechanics"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib4","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1016\/j.clinbiomech.2007.10.012","article-title":"The effect of on-body lift assistive device on the lumbar 3D dynamic moments and EMG during asymmetric freestyle lifting","volume":"23","author":"Abdoli-E","year":"2008","journal-title":"Clinical Biomechanics"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib5","doi-asserted-by":"crossref","first-page":"1694","DOI":"10.1016\/j.jbiomech.2006.09.006","article-title":"Mathematical and empirical proof of principle for an on-body personal lift augmentation device","volume":"40","author":"Abdoli-E","year":"2007","journal-title":"Journal of Biomechanics"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib6","unstructured":"Agnew, M., 2008. Kinetic and kinematic adaptations to use of a personal lift assist device. Ph.D. Thesis, Queen\u2019s University."},{"key":"10.1016\/j.jbiomech.2010.09.034_bib7","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3109\/17453678909154177","article-title":"Stability of the lumbar spine: a study in mechanical engineering","volume":"Supplement 230","author":"Bergmark","year":"1989","journal-title":"Acta Orthopaedica Scandinavica"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib8","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1097\/00007632-198604000-00011","article-title":"Back injuries in industry: a retrospective study. II. Injury factors","volume":"11","author":"Bigos","year":"1986","journal-title":"Spine"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib9","doi-asserted-by":"crossref","first-page":"1506","DOI":"10.1016\/j.jbiomech.2009.03.047","article-title":"Is slow walking more stable?","volume":"42","author":"Bruijn","year":"2009","journal-title":"Journal of Biomechanics"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib10","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1080\/001401399185829","article-title":"Low-back stresses when learning to use a materials handling device","volume":"42","author":"Chaffin","year":"1999","journal-title":"Ergonomics"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib11","doi-asserted-by":"crossref","first-page":"1377","DOI":"10.1016\/S0021-9290(00)00118-4","article-title":"Effects of external trunk loads on lumbar spine stability","volume":"33","author":"Cholewicki","year":"2000","journal-title":"Journal of Biomechanics"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/0268-0033(95)00035-6","article-title":"Mechanical stability of the in vivo lumbar spine: implications for injury and chronic low back pain","volume":"11","author":"Cholewicki","year":"1996","journal-title":"Clinical Biomechanics"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib13","doi-asserted-by":"crossref","first-page":"848","DOI":"10.1063\/1.1324008","article-title":"Nonlinear time series analysis of normal and pathological human walking","volume":"10","author":"Dingwell","year":"2000","journal-title":"Chaos"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib14","first-page":"27","article-title":"Local dynamic stability versus kinematic variability of continuous overground and treadmill walking","volume":"123","author":"Dingwell","year":"2001","journal-title":"Journal of Biomechanics"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib15","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1016\/j.jbiomech.2004.12.014","article-title":"Kinematic variability and local dynamic stability of upper body motions when walking at different speeds","volume":"39","author":"Dingwell","year":"2006","journal-title":"Journal of Biomechanics"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib16","doi-asserted-by":"crossref","first-page":"1134","DOI":"10.1103\/PhysRevA.33.1134","article-title":"Independent coordinates for strange attractors from mutual information","volume":"33","author":"Fraser","year":"1986","journal-title":"Physical Review A"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib17","doi-asserted-by":"crossref","first-page":"e403","DOI":"10.1016\/j.jelekin.2008.12.002","article-title":"PLAD (personal lift assistive device) stiffness affects the lumbar flexion\/extension moment and the posterior chain EMG during symmetrical lifting tasks","volume":"19","author":"Frost","year":"2009","journal-title":"Journal of Electromyography and Kinesiology"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib18","doi-asserted-by":"crossref","first-page":"802","DOI":"10.1002\/jor.1100130521","article-title":"Role of muscles in lumbar stability in maximum extension efforts","volume":"13","author":"Gardner-Morse","year":"1995","journal-title":"Journal of Orthopaedic Research"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib19","doi-asserted-by":"crossref","first-page":"1345","DOI":"10.1016\/j.jbiomech.2009.03.015","article-title":"Comparison of different state space definitions for local dynamic stability analyses","volume":"42","author":"Gates","year":"2009","journal-title":"Journal of Biomechanics"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib20","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/j.ergon.2008.05.008","article-title":"Testing the efficacy of an ergonomic lifting aid at diminishing muscular fatigue in women over a prolonged period of lifting","volume":"39","author":"Godwin","year":"2009","journal-title":"International Journal of Industrial Ergonomics"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib21","doi-asserted-by":"crossref","unstructured":"Graham, R.B., 2008. Effectiveness of an on-body lifting aid at reducing low back physical demands during an automotive assembly task: assessment of EMG response and user acceptability. M.Sc. Thesis, Queen\u2019s University.","DOI":"10.1016\/j.apergo.2009.01.006"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib22","doi-asserted-by":"crossref","first-page":"936","DOI":"10.1016\/j.apergo.2009.01.006","article-title":"Effectiveness of an on-body lifting aid at reducing low back physical demands during an automotive assembly task: assessment of EMG response and user acceptability","volume":"40","author":"Graham","year":"2009","journal-title":"Applied Ergonomics"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib23","doi-asserted-by":"crossref","first-page":"E271","DOI":"10.1097\/01.brs.0000216445.28943.d1","article-title":"Stability of dynamic trunk movement","volume":"31","author":"Granata","year":"2006","journal-title":"Spine"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib24","doi-asserted-by":"crossref","first-page":"1258","DOI":"10.1080\/00140130802030722","article-title":"Fatigue influences the dynamic stability of the torso","volume":"51","author":"Granata","year":"2008","journal-title":"Ergonomics"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib25","first-page":"650","article-title":"Trunk posture and spinal stability","volume":"16","author":"Granata","year":"2001","journal-title":"Journal of Biomechanics"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib26","doi-asserted-by":"crossref","first-page":"2231","DOI":"10.1016\/j.jbiomech.2009.06.038","article-title":"Dynamics and stability of muscle activations during walking in healthy young and older adults","volume":"42","author":"Kang","year":"2009","journal-title":"Journal of Biomechanics"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib27","doi-asserted-by":"crossref","first-page":"3403","DOI":"10.1103\/PhysRevA.45.3403","article-title":"Determining embedding dimension for phase-space reconstruction using a geometrical construction","volume":"45","author":"Kennel","year":"1992","journal-title":"Physical Review A"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib28","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/j.jelekin.2007.08.006","article-title":"The effect of an on-body personal lift assist device (PLAD) on fatigue during a repetitive lifting task","volume":"19","author":"Lotz","year":"2009","journal-title":"Journal of Electromyography and Kinesiology"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib29","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1080\/00140139508925111","article-title":"Biomechanical risk factors for occupationally related low back disorders","volume":"38","author":"Marras","year":"1995","journal-title":"Ergonomics"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib30","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1016\/S0268-0033(98)00020-5","article-title":"Ontario Universities Back Pain Study (OUBPS) Group","volume":"13","author":"Norman","year":"1998","journal-title":"Clinical Biomechanics"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib31","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1053\/apmr.2003.50008","article-title":"Effect of fatigue on torque output and electromyographic measures of trunk muscles during isometric axial rotation","volume":"84","author":"Ng","year":"2003","journal-title":"Archives of Physical Medicine and Rehabilitation"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib32","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1097\/00002517-199212000-00001","article-title":"The stabilizing system of the spine: Part 1. Function, dysfunction, adaptation, and enhancement","volume":"5","author":"Panjabi","year":"1992","journal-title":"Journal of Spinal Disorders"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib33","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1016\/j.jelekin.2008.07.004","article-title":"Occupational spine biomechanics: a journey to the spinal frontier","volume":"18","author":"Potvin","year":"2008","journal-title":"Journal of Electromyography and Kinesiology"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib34","doi-asserted-by":"crossref","first-page":"973","DOI":"10.1016\/j.jbiomech.2004.06.004","article-title":"An equation to calculate individual muscle contributions to joint stability","volume":"38","author":"Potvin","year":"2005","journal-title":"Journal of Biomechanics"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib35","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/0167-2789(93)90009-P","article-title":"A practical method for calculating largest Lyapunov exponents from small data sets","volume":"65","author":"Rosenstein","year":"1993","journal-title":"Physica D"},{"key":"10.1016\/j.jbiomech.2010.09.034_bib36","unstructured":"Sadler, E.M. Graham, R.B. Stevenson, J.M. The personal lift-assist device and lifting technique: a principal component analysis. Ergonomics, under review, TERG-2010-0062R1."},{"key":"10.1016\/j.jbiomech.2010.09.034_bib37","series-title":"Nonlinear Dynamics and Chaos\u2014With Applications to Physics, Biology, Chemistry, and Engineering","author":"Strogatz","year":"1994"}],"container-title":["Journal of Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S002192901000552X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S002192901000552X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,19]],"date-time":"2025-09-19T01:09:56Z","timestamp":1758244196000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S002192901000552X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,2]]},"references-count":37,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2011,2]]}},"alternative-id":["S002192901000552X"],"URL":"https:\/\/doi.org\/10.1016\/j.jbiomech.2010.09.034","relation":{},"ISSN":["0021-9290"],"issn-type":[{"value":"0021-9290","type":"print"}],"subject":[],"published":{"date-parts":[[2011,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Does the personal lift-assist device affect the local dynamic stability of the spine during lifting?","name":"articletitle","label":"Article Title"},{"value":"Journal of Biomechanics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jbiomech.2010.09.034","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2010 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}