{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T05:20:33Z","timestamp":1789536033079,"version":"build-2803163510"},"reference-count":27,"publisher":"Elsevier BV","issue":"10","license":[{"start":{"date-parts":[[2011,7,1]],"date-time":"2011-07-01T00:00:00Z","timestamp":1309478400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2011,7,1]],"date-time":"2011-07-01T00:00:00Z","timestamp":1309478400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2011,7,1]],"date-time":"2011-07-01T00:00:00Z","timestamp":1309478400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2011,7,1]],"date-time":"2011-07-01T00:00:00Z","timestamp":1309478400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2011,7,1]],"date-time":"2011-07-01T00:00:00Z","timestamp":1309478400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2011,7,1]],"date-time":"2011-07-01T00:00:00Z","timestamp":1309478400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2011,7,1]],"date-time":"2011-07-01T00:00:00Z","timestamp":1309478400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["LA 2418\/1-1"],"award-info":[{"award-number":["LA 2418\/1-1"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["PA 792\/5-1"],"award-info":[{"award-number":["PA 792\/5-1"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Biomechanics"],"published-print":{"date-parts":[[2011,7]]},"DOI":"10.1016\/j.jbiomech.2011.04.029","type":"journal-article","created":{"date-parts":[[2011,5,20]],"date-time":"2011-05-20T18:02:33Z","timestamp":1305914553000},"page":"1892-1900","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":30,"title":["An analysis of the measurement principle of smart brackets for 3D force and moment monitoring in orthodontics"],"prefix":"10.1016","volume":"44","author":[{"given":"S.","family":"Rues","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B.","family":"Panchaphongsaphak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Gieschke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"O.","family":"Paul","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B.G.","family":"Lapatki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"4","key":"10.1016\/j.jbiomech.2011.04.029_bib1","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1016\/j.ajodo.2009.02.025","article-title":"Three-dimensional orthodontic force measurements","volume":"136","author":"Badawi","year":"2009","journal-title":"American Journal of Orthodontics and Dentofacial Orthopedics"},{"key":"10.1016\/j.jbiomech.2011.04.029_bib2","series-title":"Sensors: A Comprehensive Survey, vol. 7. Mechanical Sensors","first-page":"437","article-title":"Sensors for measuring force","author":"Barbato","year":"1994"},{"issue":"5","key":"10.1016\/j.jbiomech.2011.04.029_bib3","doi-asserted-by":"crossref","first-page":"872","DOI":"10.1109\/JSEN.2005.853600","article-title":"Multidimensional CMOS in-plane stress sensor","volume":"5","author":"Bartholomeyczik","year":"2005","journal-title":"IEEE Sensors Journal"},{"issue":"2","key":"10.1016\/j.jbiomech.2011.04.029_bib4","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1034\/j.1600-0722.2002.11193.x","article-title":"Experience of pain during an orthodontic procedure","volume":"110","author":"Bergius","year":"2002","journal-title":"European Journal of Oral Sciences"},{"issue":"2","key":"10.1016\/j.jbiomech.2011.04.029_bib5","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1007\/BF01300354","article-title":"Pain in orthodontics. A review and discussion of the literature","volume":"61","author":"Bergius","year":"2000","journal-title":"Journal of Orofacial Orthopedics"},{"issue":"5","key":"10.1016\/j.jbiomech.2011.04.029_bib6","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1016\/0141-5425(92)90081-U","article-title":"An experimental apparatus for the simulation of three-dimensional movements in orthodontics","volume":"14","author":"Bourauel","year":"1992","journal-title":"Journal of Biomedical Engineering"},{"key":"10.1016\/j.jbiomech.2011.04.029_bib7","series-title":"Problem solving in orthodontic: goal-oriented treatment strategies","author":"Burstone","year":"2000"},{"key":"10.1016\/j.jbiomech.2011.04.029_bib8","series-title":"Orthodontics\u2014Current Principles and Techniques","first-page":"293","article-title":"Application of bioengineering to clinical orthodontics","author":"Burstone","year":"2005"},{"issue":"4","key":"10.1016\/j.jbiomech.2011.04.029_bib9","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1007\/PL00001936","article-title":"Root resorptions in upper first premolars after application of continuous torque moment: intra-individual study","volume":"62","author":"Casa","year":"2001","journal-title":"Journal of Orofacial Orthopedics"},{"issue":"2","key":"10.1016\/j.jbiomech.2011.04.029_bib10","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1016\/j.ajodo.2003.11.026","article-title":"Physical properties of root cementum: part 5. Volumetric analysis of root resorption craters after application of light and heavy orthodontic forces","volume":"127","author":"Chan","year":"2005","journal-title":"American Journal of Orthodontics and Dentofacial Orthopedics"},{"issue":"1","key":"10.1016\/j.jbiomech.2011.04.029_bib11","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/S0021-9290(98)00112-2","article-title":"Measuring system for in vivo recording of force systems in orthodontic treatment-concept and analysis of accuracy","volume":"32","author":"Friedrich","year":"1999","journal-title":"Journal of Biomechanics"},{"key":"10.1016\/j.jbiomech.2011.04.029_bib12","doi-asserted-by":"crossref","unstructured":"Gieschke, P., Nurcahyo, Y., Herrmann, M., Kuhl, M., Ruther, P., Paul, O., 2008. Integrated stress mapping chip with 32 piezoresistive field effect transistors. In: Proceedings of the Eurosensors XXII Conference, Dresden, Germany.","DOI":"10.1109\/MEMSYS.2009.4805496"},{"key":"10.1016\/j.jbiomech.2011.04.029_bib13","doi-asserted-by":"crossref","unstructured":"Gieschke, P., Nurcahyo, Y., Herrmann, M., Kuhl, M., Ruther, P., Paul, O., 2009. CMOS integrated stress mapping chips with 32N-type or P-type piezoresistive field effect transistors. In: Proceedings of the 22nd IEEE International Conference on Micro Electro Mechanical Systems (MEMS), Sorrento, Italy.","DOI":"10.1109\/MEMSYS.2009.4805496"},{"issue":"3","key":"10.1016\/j.jbiomech.2011.04.029_bib14","first-page":"239","article-title":"An improved transpalatal bar design. Part I. Comparison of moments and forces delivered by two bar designs for symmetrical molar derotation","volume":"73","author":"G\u00fcnd\u00fcz","year":"2003","journal-title":"Angle Orthodontist"},{"issue":"3","key":"10.1016\/j.jbiomech.2011.04.029_bib15","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/j.ajodo.2004.07.037","article-title":"Influence of force systems on archwire-bracket combinations","volume":"127","author":"Kusy","year":"2005","journal-title":"American Journal of Orthodontics and Dentofacial Orthopedics"},{"issue":"1","key":"10.1016\/j.jbiomech.2011.04.029_bib16","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1177\/154405910708600112","article-title":"Smart bracket for multi-dimensional force and moment measurement","volume":"86","author":"Lapatki","year":"2007","journal-title":"Journal of Dental Research"},{"issue":"5","key":"10.1016\/j.jbiomech.2011.04.029_bib17","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1007\/s00056-007-0728-8","article-title":"Smart brackets for 3D-force\u2013moment measurements in orthodontic research and therapy\u2013Developmental status and prospects","volume":"68","author":"Lapatki","year":"2007","journal-title":"Journal of Orofacial Orthopedics"},{"key":"10.1016\/j.jbiomech.2011.04.029_bib18","doi-asserted-by":"crossref","unstructured":"Lemke, B., Kratt, K., Baskaran, R., Paul, O., 2009. Towards piezoresistive CMOS sensors for out-of-plane stress. In: Proceedings of the Technical Digest of IEEE 22nd International Conference on Micro Electro Mechanical Systems, Sorrento, Italy, pp. 781\u2013784.","DOI":"10.1109\/MEMSYS.2009.4805499"},{"issue":"3","key":"10.1016\/j.jbiomech.2011.04.029_bib19","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1093\/ejo\/cjl001","article-title":"The tissue, cellular, and molecular regulation of orthodontic tooth movement: 100 years after Carl Sandstedt","volume":"28","author":"Meikle","year":"2006","journal-title":"European Journal of Orthodontics"},{"issue":"1","key":"10.1016\/j.jbiomech.2011.04.029_bib20","first-page":"49","article-title":"3-D experimental identification of force systems from orthodontic loops activated for first order corrections","volume":"69","author":"Menghi","year":"1999","journal-title":"Angle Orthodontist"},{"key":"10.1016\/j.jbiomech.2011.04.029_bib21","series-title":"Bioengineering Analysis of Orthodontic Mechanics","author":"Nikolai","year":"1985"},{"key":"10.1016\/j.jbiomech.2011.04.029_bib22","series-title":"Physical Properties of Crystals: Their Representation by Tensors and Matrices","author":"Nye","year":"1985"},{"key":"10.1016\/j.jbiomech.2011.04.029_bib23","series-title":"Contemporary Orthodontics","first-page":"326","article-title":"Mechanical principles in orthodontic force control","author":"Proffit","year":"2000"},{"key":"10.1016\/j.jbiomech.2011.04.029_bib24","series-title":"Bioprogressive Therapie","author":"Ricketts","year":"1988"},{"issue":"6","key":"10.1016\/j.jbiomech.2011.04.029_bib25","doi-asserted-by":"crossref","first-page":"538","DOI":"10.1109\/TBME.1977.326167","article-title":"A device for determining the mechanical behavior of orthodontic appliances","volume":"24","author":"Solonche","year":"1977","journal-title":"IEEE Transactions on Biomedical Engineering"},{"key":"10.1016\/j.jbiomech.2011.04.029_bib26","unstructured":"Tseng, F.-G., Yang, C.-S., Pan, L.-C., 2004. An elastomeric tactile sensor employing dielectric constant variation and applicable to orthodontia. In: Proceedings of the 17th IEEE International Conference on Micro Electro Mechanical Systems (MEMS), Maastricht, Netherlands."},{"issue":"2","key":"10.1016\/j.jbiomech.2011.04.029_bib27","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1007\/s00056-004-0214-5","article-title":"Development and biomechanical investigation of a new compound palatal arch","volume":"65","author":"Wichelhaus","year":"2004","journal-title":"Journal of Orofacial Orthopedics"}],"container-title":["Journal of Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021929011003496?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021929011003496?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,19]],"date-time":"2025-09-19T01:09:44Z","timestamp":1758244184000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0021929011003496"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,7]]},"references-count":27,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2011,7]]}},"alternative-id":["S0021929011003496"],"URL":"https:\/\/doi.org\/10.1016\/j.jbiomech.2011.04.029","relation":{},"ISSN":["0021-9290"],"issn-type":[{"value":"0021-9290","type":"print"}],"subject":[],"published":{"date-parts":[[2011,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"An analysis of the measurement principle of smart brackets for 3D force and moment monitoring in orthodontics","name":"articletitle","label":"Article Title"},{"value":"Journal of Biomechanics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jbiomech.2011.04.029","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2011 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}