{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T14:19:41Z","timestamp":1780582781601,"version":"3.54.1"},"reference-count":36,"publisher":"Elsevier BV","issue":"12","license":[{"start":{"date-parts":[[2013,8,1]],"date-time":"2013-08-01T00:00:00Z","timestamp":1375315200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2013,8,1]],"date-time":"2013-08-01T00:00:00Z","timestamp":1375315200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Biomechanics"],"published-print":{"date-parts":[[2013,8]]},"DOI":"10.1016\/j.jbiomech.2013.05.025","type":"journal-article","created":{"date-parts":[[2013,6,20]],"date-time":"2013-06-20T10:45:48Z","timestamp":1371725148000},"page":"2039-2044","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":12,"title":["Effect of bar cross-section geometry on stress distribution in overdenture-retaining system simulating horizontal misfit and bone loss"],"prefix":"10.1016","volume":"46","author":[{"given":"Alo\u00edsio Oro","family":"Spazzin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ana Rosa","family":"Costa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Am\u00e9rico Bortolazzo","family":"Correr","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rafael Leonardo Xediek","family":"Consani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Louren\u00e7o","family":"Correr-Sobrinho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mateus Bertolini Fernandes dos","family":"Santos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jbiomech.2013.05.025_bib1","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.prosdent.2005.03.013","article-title":"The glossary of prosthodontic terms","volume":"94","author":"Anon","year":"2005","journal-title":"Journal of Prosthetic Dentistry"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib2","first-page":"559","article-title":"The effect of a hydroxyapatite-reinforced polyethylene stress distributor in a dental implant on compressive stress levels in surrounding bone","volume":"15","author":"Abu-Hammad","year":"2000","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib3","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1046\/j.1365-2842.2003.01002.x","article-title":"A mimic osseointegrated implant model for three-dimensional finite element analysis","volume":"30","author":"Akagawa","year":"2003","journal-title":"Journal of Oral Rehabilitation"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib4","first-page":"125","article-title":"A comparison of the accuracy of fit of 2 methods for fabricating implant-prosthodontic frameworks","volume":"20","author":"Al-Fadda","year":"2007","journal-title":"International Journal of Prosthodontics"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib5","first-page":"38","article-title":"Changes in prosthetic screw stability because of misfit of implant-supported prostheses","volume":"15","author":"al-Turki","year":"2002","journal-title":"International Journal of Prosthodontics"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib6","first-page":"195","article-title":"Prosthodontic complications with implant overdentures: a systematic literature review","volume":"23","author":"Andreiotelli","year":"2010","journal-title":"International Journal of Prosthodontics"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib7","first-page":"216","article-title":"Accuracy of implant impression techniques","volume":"11","author":"Assif","year":"1996","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib8","first-page":"425","article-title":"Long-term treatment outcomes in edentulous patients with implant overdentures: the Toronto study","volume":"17","author":"Attard","year":"2004","journal-title":"International Journal of Prosthodontics"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib9","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/0022-3913(85)90066-6","article-title":"Clinical long-term study of complete denture wearers","volume":"53","author":"Bergman","year":"1985","journal-title":"Journal of Prosthetic Dentistry"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib10","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/S0022-3913(11)60088-7","article-title":"Randomized, prospective, clinical evaluation of prosthodontic modalities for mandibular implant overdenture treatment","volume":"106","author":"Burns","year":"2011","journal-title":"Journal of Prosthetic Dentistry"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib11","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1111\/j.1532-849X.1993.tb00373.x","article-title":"Full-arch implant framework casting accuracy: preliminary in vitro observation for in vivo testing","volume":"2","author":"Carr","year":"1993","journal-title":"Journal of Prosthodontics"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib12","series-title":"Restorative Dental Materials","author":"Craig","year":"1989"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib13","doi-asserted-by":"crossref","first-page":"1761","DOI":"10.1016\/j.jbiomech.2010.02.017","article-title":"Load transfer along the bone\u2014dental implant interface","volume":"43","author":"Faegh","year":"2010","journal-title":"Journal of Biomechanics"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib14","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1016\/S0022-3913(07)60147-4","article-title":"Effect of implant-supported or retained dentures on masticatory performance: A systematic review","volume":"98","author":"Fueki","year":"2007","journal-title":"Journal of Prosthetic Dentistry"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib15","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1111\/j.1365-2842.2010.02149.x","article-title":"Current computational modelling trends in craniomandibular biomechanics and their clinical implications","volume":"38","author":"Hannam","year":"2011","journal-title":"Journal of Oral Rehabilitation"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib16","series-title":"Basic Stress Analysis","author":"Iremonger","year":"1982"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib17","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1590\/S1678-77572004000400016","article-title":"Use of base metal casting alloys for implant framework: Marginal accuracy analysis","volume":"12","author":"Kano","year":"2004","journal-title":"Journal of Applied Oral Science"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib18","first-page":"555","article-title":"Effect of intraoral scanning on the passivity of fit of implant-supported fixed dental prostheses","volume":"43","author":"Karl","year":"2012","journal-title":"Quintessence International"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib19","doi-asserted-by":"crossref","first-page":"838","DOI":"10.1111\/j.1600-0501.2009.01723.x","article-title":"Rotational movements of mandibular two-implant overdentures","volume":"20","author":"Kimoto","year":"2009","journal-title":"Clinical Oral Implants Research"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib20","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/S0022-3913(99)70129-0","article-title":"Influence of mandibular superstructure shape on implant stresses during simulated posterior biting","volume":"82","author":"Korioth","year":"1999","journal-title":"Journal of Prosthetic Dentistry"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib21","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1111\/j.1600-051X.2004.00510.x","article-title":"Mandibular overdentures supported by two Branemark, IMZ or ITI implants: A 5-year prospective study","volume":"31","author":"Meijer","year":"2004","journal-title":"Journal of Clinical Periodontology"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib22","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1111\/j.1600-051X.2009.01442.x","article-title":"Mandibular overdentures supported by two Branemark, IMZ or ITI implants: A ten-year prospective randomized study","volume":"36","author":"Meijer","year":"2009","journal-title":"Journal of Clinical Periodontology"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib23","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1016\/j.dental.2005.08.001","article-title":"Evaluation of stress induced in peri-implant bone tissue by misfit in multi-implant prosthesis","volume":"22","author":"Natali","year":"2006","journal-title":"Dental Materials"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib24","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1016\/0022-3913(89)90285-0","article-title":"Basic biomechanics of dental implants in prosthetic dentistry","volume":"61","author":"Richter","year":"1989","journal-title":"Journal of Prosthetic Dentistry"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib25","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1067\/mpr.2000.111494","article-title":"Accuracy of three corrective techniques for implant bar fabrication","volume":"84","author":"Romero","year":"2000","journal-title":"Journal of Prosthetic Dentistry"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib26","first-page":"491","article-title":"Comparison of interface relationships between implant components for laser-welded titanium frameworks and standard cast frameworks","volume":"14","author":"Rubenstein","year":"1999","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib27","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1097\/00008505-200104000-00003","article-title":"The significance of passive framework fit in implant prosthodontics: current status","volume":"10","author":"Sahin","year":"2001","journal-title":"Implant Dentistry"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib28","first-page":"655","article-title":"Nonlinear finite element contact analysis of dental implant components","volume":"8","author":"Sakaguchi","year":"1993","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib29","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.prosdent.2004.04.001","article-title":"In vitro comparative analysis of the fit of gold alloy or commercially pure titanium implant-supported prostheses before and after electroerosion","volume":"92","author":"Sartori","year":"2004","journal-title":"Journal of Prosthetic Dentistry"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib30","first-page":"96","article-title":"Influence of laser-welding and electroerosion on passive fit of implant-supported prosthesis","volume":"10","author":"Silva","year":"2008","journal-title":"Stomatologija"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib31","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1111\/j.1532-849X.2011.00708.x","article-title":"Evaluation of stress distribution in overdenture-retaining bar with different levels of vertical misfit","volume":"20","author":"Spazzin","year":"2011","journal-title":"Journal of Prosthodontics"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib32","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1111\/j.1532-849X.2011.00759.x","article-title":"Effects of horizontal misfit and bar framework material on the stress distribution of an overdenture-retaining bar system: A 3D finite element analysis","volume":"20","author":"Spazzin","year":"2011","journal-title":"Journal of Prosthodontics"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib33","doi-asserted-by":"crossref","unstructured":"Szabo, M.E., Thurner, P.J., 2012. Anisotropy of bovine cortical bone tissue damage properties. Journal of Biomechanics","DOI":"10.1016\/j.jbiomech.2012.08.002"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib34","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/0022-3913(90)90202-N","article-title":"The influence of clinical variables on patients' satisfaction with complete dentures","volume":"63","author":"van Waas","year":"1990","journal-title":"Journal of Prosthetic Dentistry"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib35","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/0022-3913(83)90029-X","article-title":"Osseointegrated dental implants: preliminary report on a replication study","volume":"50","author":"Zarb","year":"1983","journal-title":"Journal of Prosthetic Dentistry"},{"key":"10.1016\/j.jbiomech.2013.05.025_bib36","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1111\/j.1532-849X.1999.tb00032.x","article-title":"Distortion of three-unit implant frameworks during casting, soldering, and simulated porcelain firings","volume":"8","author":"Zervas","year":"1999","journal-title":"Journal of Prosthodontics"}],"container-title":["Journal of Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021929013002583?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021929013002583?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,19]],"date-time":"2025-09-19T01:12:10Z","timestamp":1758244330000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0021929013002583"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,8]]},"references-count":36,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2013,8]]}},"alternative-id":["S0021929013002583"],"URL":"https:\/\/doi.org\/10.1016\/j.jbiomech.2013.05.025","relation":{},"ISSN":["0021-9290"],"issn-type":[{"value":"0021-9290","type":"print"}],"subject":[],"published":{"date-parts":[[2013,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Effect of bar cross-section geometry on stress distribution in overdenture-retaining system simulating horizontal misfit and bone loss","name":"articletitle","label":"Article Title"},{"value":"Journal of Biomechanics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jbiomech.2013.05.025","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2013 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}