{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T03:16:28Z","timestamp":1791429388057,"version":"4.3.3"},"reference-count":28,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2014,3,1]],"date-time":"2014-03-01T00:00:00Z","timestamp":1393632000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["jbiomech.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Biomechanics"],"published-print":{"date-parts":[[2014,3]]},"DOI":"10.1016\/j.jbiomech.2014.01.024","type":"journal-article","created":{"date-parts":[[2014,1,21]],"date-time":"2014-01-21T06:01:33Z","timestamp":1390284093000},"page":"957-965","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":40,"title":["In vitro assessment of the influence of aortic annulus ovality on the hydrodynamic performance of self-expanding transcatheter heart valve prostheses"],"prefix":"10.1016","volume":"47","author":[{"given":"Maximilian","family":"Kuetting","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Sedaghat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc","family":"Utzenrath","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan-Malte","family":"Sinning","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christoph","family":"Schmitz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Roggenkamp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nikos","family":"Werner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Schmitz-Rode","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ulrich","family":"Steinseifer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jbiomech.2014.01.024_bib1","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1111\/j.1540-8183.2011.00679.x","article-title":"Transfemorally or transapically deployed Sapien Edwards bioprosthesis is always deformed","volume":"25","author":"Allam","year":"2012","journal-title":"J. Interv. Cardiol."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib2","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1016\/j.jtcvs.2011.12.036","article-title":"In vitro assessment of prosthesis type and pressure recovery characteristics: Doppler echocardiography overestimation of bileaflet mechanical and bioprosthetic aortic valve gradients","volume":"144","author":"Bach","year":"2012","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib3","series-title":"Theoretical Microfluidics. Oxford Master Series in Condensed Matter Physics","first-page":"37","author":"Bruus","year":"2008"},{"key":"10.1016\/j.jbiomech.2014.01.024_bib5","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1161\/CIRCINTERVENTIONS.112.971614","article-title":"Efficacy and safety of postdilatation to reduce paravalvular regurgitation during balloon-expandable transcatheter aortic valve replacement","volume":"6","author":"Daneault","year":"2013","journal-title":"Circ. Cardiovasc. Interv."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib6","doi-asserted-by":"crossref","first-page":"821","DOI":"10.1016\/j.jcin.2009.07.003","article-title":"Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence","volume":"2","author":"Detaint","year":"2009","journal-title":"JACC Cardiovasc. Interv."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib7","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1055\/s-2005-873061","article-title":"Impact of pressure recovery in the evaluation of the Omnicarbon tilting disc valve","volume":"54","author":"Dohmen","year":"2006","journal-title":"Thorac. Cardiovasc. Surg."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib8","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1055\/s-0030-1271012","article-title":"Influence of aortic dimensions on the hemodynamic performance of small aortic valve prostheses: impact on patient\/prosthesis mismatch","volume":"59","author":"Dohmen","year":"2011","journal-title":"Thorac. Cardiovasc. Surg."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib9","doi-asserted-by":"crossref","first-page":"1705","DOI":"10.1056\/NEJMoa1114705","article-title":"Registry of transcatheter aortic-valve implantation in high-risk patients","volume":"366","author":"Gilard","year":"2012","journal-title":"N. Engl. J. Med."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib10","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/j.jtcvs.2009.09.037","article-title":"A new approach to interventional atrioventricular valve therapy","volume":"140","author":"Goetzenich","year":"2010","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib11","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1016\/j.amjcard.2012.04.064","article-title":"Feasibility and outcomes of transcatheter aortic valve implantation in high-risk patients with stenotic bicuspid aortic valves","volume":"110","author":"Himbert","year":"2012","journal-title":"Am. J. Cardiol."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib12","unstructured":"ISO 5840-3, 2013. Cardiovascular Implants \u2013 Cardiac Valve Prostheses \u2013 Part 3: Heart Valve Substitutes Implanted by Transcatheter Technique. ISO 5840-3:2013. ISO, Geneva, Switzerland."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib13","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1093\/ejcts\/ezs064","article-title":"Aortic annulus sizing: echocardiographic versus computed tomography derived measurements in comparison with direct surgical sizing","volume":"42","author":"Kempfert","year":"2012","journal-title":"Eur. J. Cardiothorac. Surg."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib14","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/j.jcin.2012.07.019","article-title":"Intracardiac visualization of transcatheter aortic valve and valve-in-valve implantation in an in vitro passive beating heart","volume":"6","author":"Leopaldi","year":"2013","journal-title":"JACC Cardiovasc. Interv."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib15","doi-asserted-by":"crossref","first-page":"1133","DOI":"10.1016\/j.jbiomech.2012.02.007","article-title":"In vitro hemodynamics and valve imaging in passive beating hearts","volume":"45","author":"Leopaldi","year":"2012","journal-title":"J. Biomech."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib16","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1016\/j.jacc.2009.06.063","article-title":"Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation","volume":"55","author":"Messika-Zeitoun","year":"2010","journal-title":"J. Am. Coll. Cardiol."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib17","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/0021-9290(90)90351-3","article-title":"The geometry of the aortic root in health, at valve disease and after valve replacement","volume":"23","author":"Reul","year":"1990","journal-title":"J. Biomech."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib18","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1016\/S0022-5223(19)34073-5","article-title":"In vitro comparison of bileaflet aortic heart valve prostheses. St. Jude Medical, CarboMedics, modified Edwards-Duromedics, and Sorin-Bicarbon valves","volume":"106","author":"Reul","year":"1993","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib19","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1007\/s10439-009-9653-x","article-title":"A dynamic heart system to facilitate the development of mitral valve repair techniques","volume":"37","author":"Richards","year":"2009","journal-title":"Ann. Biomed. Eng."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib20","doi-asserted-by":"crossref","first-page":"564","DOI":"10.4244\/EIJV7I5A92","article-title":"Aortic annulus dimensions and leaflet calcification from contrast MSCT predict the need for balloon post-dilatation after TAVI with the Medtronic CoreValve prosthesis","volume":"7","author":"Schultz","year":"2011","journal-title":"EuroIntervention"},{"key":"10.1016\/j.jbiomech.2014.01.024_bib21","doi-asserted-by":"crossref","first-page":"911","DOI":"10.1016\/j.jacc.2009.04.075","article-title":"Geometry and degree of apposition of the CoreValve ReValving system with multislice computed tomography after implantation in patients with aortic stenosis","volume":"54","author":"Schultz","year":"2009","journal-title":"J. Am. Coll. Cardiol."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib22","doi-asserted-by":"crossref","first-page":"1134","DOI":"10.1016\/j.jacc.2011.11.048","article-title":"Aortic regurgitation index defines severity of peri-prosthetic regurgitation and predicts outcome in patients after transcatheter aortic valve implantation","volume":"59","author":"Sinning","year":"2012","journal-title":"J. Am. Coll. Cardiol."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib23","doi-asserted-by":"crossref","first-page":"3085","DOI":"10.1016\/j.jbiomech.2010.08.010","article-title":"Simulated elliptical bioprosthetic valve deformation: implications for asymmetric transcatheter valve deployment","volume":"43","author":"Sun","year":"2010","journal-title":"J. Biomech."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib24","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1016\/j.jcmg.2007.12.006","article-title":"Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement","volume":"1","author":"Tops","year":"2008","journal-title":"JACC. Cardiovasc. Imaging"},{"key":"10.1016\/j.jbiomech.2014.01.024_bib25","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1093\/eurheartj\/ehr491","article-title":"Transcatheter aortic valve implantation: 3-year outcomes of self-expanding CoreValve prosthesis","volume":"33","author":"Ussia","year":"2012","journal-title":"Eur. Heart J."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib26","first-page":"167","article-title":"Guidelines on the management of valvular heart disease (version 2012). The Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS)","volume":"14","author":"Vahanian","year":"2013","journal-title":"G. Ital. Cardiol. (Rome)"},{"key":"10.1016\/j.jbiomech.2014.01.024_bib27","doi-asserted-by":"crossref","first-page":"858","DOI":"10.1016\/j.jcin.2012.04.011","article-title":"Impact of paravalvular leakage on outcome in patients after transcatheter aortic valve implantation","volume":"5","author":"Vasa-Nicotera","year":"2012","journal-title":"JACC Cardiovasc. Interv."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib28","first-page":"190","article-title":"Relationship of aortic annular eccentricity and paravalvular regurgitation post transcatheter aortic valve implantation with corevalve","volume":"25","author":"Wong","year":"2013","journal-title":"J. Invasive Cardiol."},{"key":"10.1016\/j.jbiomech.2014.01.024_bib29","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1016\/j.jacc.2007.10.023","article-title":"Is it reasonable to treat all calcified stenotic aortic valves with a valved stent? Results from a human anatomic study in adults","volume":"51","author":"Zegdi","year":"2008","journal-title":"J. Am. Coll. Cardiol."}],"container-title":["Journal of Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021929014000554?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021929014000554?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2020,8,14]],"date-time":"2020-08-14T10:43:04Z","timestamp":1597401784000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0021929014000554"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,3]]},"references-count":28,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2014,3]]}},"alternative-id":["S0021929014000554"],"URL":"https:\/\/doi.org\/10.1016\/j.jbiomech.2014.01.024","relation":{},"ISSN":["0021-9290"],"issn-type":[{"value":"0021-9290","type":"print"}],"subject":[],"published":{"date-parts":[[2014,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"In vitro assessment of the influence of aortic annulus ovality on the hydrodynamic performance of self-expanding transcatheter heart valve prostheses","name":"articletitle","label":"Article Title"},{"value":"Journal of Biomechanics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jbiomech.2014.01.024","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}