{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T08:29:30Z","timestamp":1782203370021,"version":"3.54.5"},"reference-count":26,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2017,3,1]],"date-time":"2017-03-01T00:00:00Z","timestamp":1488326400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"name":"American Heart Association Scientist Development","award":["#14SDG19690010"],"award-info":[{"award-number":["#14SDG19690010"]}]}],"content-domain":{"domain":["jbiomech.com","clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Biomechanics"],"published-print":{"date-parts":[[2017,3]]},"DOI":"10.1016\/j.jbiomech.2017.01.048","type":"journal-article","created":{"date-parts":[[2017,2,7]],"date-time":"2017-02-07T00:47:24Z","timestamp":1486428444000},"page":"111-116","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":17,"special_numbering":"C","title":["Patient-specific in vitro models for hemodynamic analysis of congenital heart disease \u2013 Additive manufacturing approach"],"prefix":"10.1016","volume":"54","author":[{"given":"Rafael","family":"Medero","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sylvana","family":"Garc\u00eda-Rodr\u00edguez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher J.","family":"Fran\u00e7ois","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alejandro","family":"Rold\u00e1n-Alzate","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jbiomech.2017.01.048_b0005","doi-asserted-by":"crossref","unstructured":"Anderson, J.R., Diaz, O., Klucznik, R., Zhang, Y.J., Britz, G.W., Grossman, R.G., Lv, N., Huang, Q., Karmonik, C., 2014. Validation of computational fluid dynamics methods with anatomically exact, 3D printed MRI phantoms and 4D pcMRI. In: Conf. Proc. Ellipsis Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. IEEE Eng. Med. Biol. Soc. Annu. Conf., pp. 6699\u20136701. http:\/\/dx.doi.org\/10.1109\/EMBC.2014.6945165.","DOI":"10.1109\/EMBC.2014.6945165"},{"key":"10.1016\/j.jbiomech.2017.01.048_b0010","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1148\/radiol.12120778","article-title":"Caval blood flow distribution in patients with Fontan circulation: quantification by using particle traces from 4D flow MR imaging","volume":"267","author":"B\u00e4chler","year":"2013","journal-title":"Radiology"},{"key":"10.1016\/j.jbiomech.2017.01.048_b0015","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1115\/1.1537734","article-title":"Experimental flow studies in exact-replica phantoms of atherosclerotic carotid bifurcations under steady input conditions","volume":"125","author":"Bale-Glickman","year":"2003","journal-title":"J. Biomech. Eng."},{"key":"10.1016\/j.jbiomech.2017.01.048_b0020","doi-asserted-by":"crossref","first-page":"2873","DOI":"10.1161\/01.CIR.98.25.2873","article-title":"In vivo evaluation of Fontan pathway flow dynamics by multidimensional phase-velocity magnetic resonance imaging","volume":"98","author":"Be\u2019eri","year":"2015","journal-title":"Circulation"},{"key":"10.1016\/j.jbiomech.2017.01.048_b0025","first-page":"2550","article-title":"Characterization of cerebral aneurysms for assessing risk of rupture by using patient-specific computational hemodynamics models","volume":"26","author":"Cebral","year":"2005","journal-title":"Am. J. Neuroradiol."},{"key":"10.1016\/j.jbiomech.2017.01.048_b0030","doi-asserted-by":"crossref","first-page":"2094","DOI":"10.1016\/j.athoracsur.2004.12.052","article-title":"In vitro flow analysis of a patient-specific intraatrial total cavopulmonary connection","volume":"79","author":"de Z\u00e9licourt","year":"2005","journal-title":"Ann. Thorac. Surg."},{"key":"10.1016\/j.jbiomech.2017.01.048_b0035","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1002\/cnm.2508","article-title":"Influence of bypass angles on extracardiac Fontan connections: a numerical study","volume":"29","author":"Ding","year":"2013","journal-title":"Int. J. Numer. Method. Biomed. Eng."},{"key":"10.1016\/j.jbiomech.2017.01.048_b0040","doi-asserted-by":"crossref","first-page":"31012","DOI":"10.1115\/1.4000954","article-title":"Optimization of inflow waveform phase-difference for minimized total cavopulmonary power loss","volume":"132","author":"Dur","year":"2010","journal-title":"J. Biomech. Eng."},{"key":"10.1016\/j.jbiomech.2017.01.048_b0045","series-title":"Understanding Additive Manufacturing: Rapid Prototyping, Rapid Tooling, Rapid Manufacturing","author":"Gebhardt","year":"2012"},{"key":"10.1016\/j.jbiomech.2017.01.048_b0050","series-title":"Additive Manufacturing Technologies: Rapid Prototyping to Direct Digital Manufacturing","author":"Gibson","year":"2010"},{"key":"10.1016\/j.jbiomech.2017.01.048_b0055","first-page":"743","article-title":"PC VIPR: a high-speed 3D phase-contrast method for flow quantification and high-resolution angiography","volume":"26","author":"Gu","year":"2005","journal-title":"Am. J. Neuroradiol."},{"key":"10.1016\/j.jbiomech.2017.01.048_b0060","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s10439-012-0614-4","article-title":"Comparing pre- and post-operative Fontan hemodynamic simulations: implications for the reliability of surgical planning","volume":"40","author":"Haggerty","year":"2012","journal-title":"Ann. Biomed. Eng."},{"key":"10.1016\/j.jbiomech.2017.01.048_b0065","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1016\/j.jtcvs.2012.03.076","article-title":"Simulating hemodynamics of the Fontan Y-graft based on patient-specific invivo connections","volume":"145","author":"Haggerty","year":"2013","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"10.1016\/j.jbiomech.2017.01.048_b0070","doi-asserted-by":"crossref","first-page":"2065","DOI":"10.1016\/j.jacc.2004.08.031","article-title":"Cardiac transplantation after the Fontan or Glenn procedure","volume":"44","author":"Jayakumar","year":"2004","journal-title":"J. Am. Coll. Cardiol."},{"key":"10.1016\/j.jbiomech.2017.01.048_b0075","doi-asserted-by":"crossref","first-page":"6300","DOI":"10.1118\/1.3652917","article-title":"Flow characteristics in a canine aneurysm model: a comparison of 4D accelerated phase-contrast MR measurements and computational fluid dynamics simulations","volume":"38","author":"Jiang","year":"2011","journal-title":"Med. Phys."},{"key":"10.1016\/j.jbiomech.2017.01.048_b0080","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1002\/mrm.22202","article-title":"Improved SNR in phase contrast velocimetry with five-point balanced flow encoding","volume":"63","author":"Johnson","year":"2010","journal-title":"Magn. Reson. Med."},{"key":"10.1016\/j.jbiomech.2017.01.048_b0085","first-page":"2115","article-title":"Long-term survival, modes of death, and predictors of mortality in patients with Fontan surgery","author":"Khairy","year":"2008","journal-title":"Circulation"},{"key":"10.1016\/j.jbiomech.2017.01.048_b0090","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1002\/jmri.24233","article-title":"Effect of temporal resolution on 4D flow MRI in the portal circulation","volume":"39","author":"Landgraf","year":"2014","journal-title":"J. Magn. Reson. Imaging"},{"key":"10.1016\/j.jbiomech.2017.01.048_b0095","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1097\/00008480-200210000-00010","article-title":"Outcomes after the Fontan procedure","author":"Marino","year":"2002","journal-title":"Curr. Opin. Pediatr."},{"key":"10.1016\/j.jbiomech.2017.01.048_b0100","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/j.ejcts.2010.05.026","article-title":"Time-resolved three-dimensional magnetic resonance velocity mapping of cardiovascular flow paths in volunteers and patients with Fontan circulation","volume":"39","author":"Markl","year":"2011","journal-title":"Eur. J. Cardio-Thoracic Surg."},{"key":"10.1016\/j.jbiomech.2017.01.048_b0105","doi-asserted-by":"crossref","first-page":"1325","DOI":"10.1016\/j.jbiomech.2015.03.009","article-title":"Hemodynamic study of TCPC using in vivo and in vitro 4D Flow MRI and numerical simulation","volume":"48","author":"Rold\u00e1n-Alzate","year":"2015","journal-title":"J. Biomech."},{"key":"10.1016\/j.jbiomech.2017.01.048_b0110","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1016\/S1010-7940(03)00495-0","article-title":"Surgical results of patients with a functional single ventricle","volume":"24","author":"Ryul","year":"2003","journal-title":"Eur. J. Cardio-Thoracic Surg."},{"key":"10.1016\/j.jbiomech.2017.01.048_b0115","doi-asserted-by":"crossref","unstructured":"Soerensen, D.D., Pekkan, K., Sundareswaran, K.S., Yoganathan, A.P., 2004. New power loss optimized Fontan connection evaluated by calculation of power loss using high resolution PC-MRI and CFD. In: Conf. Proc. Ellipsis Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. IEEE Eng. Med. Biol. Soc. Annu. Conf., vol. 2, pp. 1144\u20131147. http:\/\/dx.doi.org\/10.1109\/IEMBS.2004.1403367.","DOI":"10.1109\/IEMBS.2004.1403367"},{"key":"10.1016\/j.jbiomech.2017.01.048_b0120","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1016\/j.ijthermalsci.2006.01.004","article-title":"Characterization of the effect of surface roughness and texture on fluid flow\u2014past, present, and future","volume":"45","author":"Taylor","year":"2006","journal-title":"Int. J. Therm. Sci."},{"key":"10.1016\/j.jbiomech.2017.01.048_b0125","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCULATIONAHA.106.680827","article-title":"Nonlinear power loss during exercise in single-ventricle patients after the Fontan: insights from computational fluid dynamics","volume":"116","author":"Whitehead","year":"2007","journal-title":"Circulation"},{"key":"10.1016\/j.jbiomech.2017.01.048_b0130","doi-asserted-by":"crossref","first-page":"800","DOI":"10.1002\/mrm.1910360521","article-title":"Temporally resolved 3D phase-contrast imaging","volume":"36","author":"Wigstrom","year":"1996","journal-title":"Magn. Reson. Med."}],"container-title":["Journal of Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021929017300842?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021929017300842?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,4]],"date-time":"2018-09-04T09:52:00Z","timestamp":1536054720000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0021929017300842"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,3]]},"references-count":26,"alternative-id":["S0021929017300842"],"URL":"https:\/\/doi.org\/10.1016\/j.jbiomech.2017.01.048","relation":{},"ISSN":["0021-9290"],"issn-type":[{"value":"0021-9290","type":"print"}],"subject":[],"published":{"date-parts":[[2017,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Patient-specific in vitro models for hemodynamic analysis of congenital heart disease \u2013 Additive manufacturing approach","name":"articletitle","label":"Article Title"},{"value":"Journal of Biomechanics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jbiomech.2017.01.048","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}