{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,16]],"date-time":"2026-02-16T09:31:33Z","timestamp":1771234293934,"version":"3.50.1"},"reference-count":16,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2021,5,1]],"date-time":"2021-05-01T00:00:00Z","timestamp":1619827200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,5,1]],"date-time":"2021-05-01T00:00:00Z","timestamp":1619827200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2022,4,16]],"date-time":"2022-04-16T00:00:00Z","timestamp":1650067200000},"content-version":"am","delay-in-days":350,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100000038","name":"US Food and Drug Administration","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000038","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Biomechanics"],"published-print":{"date-parts":[[2021,5]]},"DOI":"10.1016\/j.jbiomech.2021.110412","type":"journal-article","created":{"date-parts":[[2021,4,5]],"date-time":"2021-04-05T12:21:40Z","timestamp":1617625300000},"page":"110412","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":8,"special_numbering":"C","title":["Development of an in vitro test method to simulate intra-operative impaction loading on lumbar intervertebral body fusion devices"],"prefix":"10.1016","volume":"121","author":[{"given":"Vivek","family":"Palepu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonathan H.","family":"Peck","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eileen S.","family":"Cadel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0107-5533","authenticated-orcid":false,"given":"Ankit R.","family":"Parikh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9454-4022","authenticated-orcid":false,"given":"Scott C.","family":"Wagner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"suffix":"Jr.","given":"Donald R.","family":"Fredericks","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Melvin D.","family":"Helgeson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anton E.","family":"Dmitriev","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jbiomech.2021.110412_b0005","unstructured":"ASTM, 2018a. ASTM F2077-18, Test methods for intervertebral body fusion devices. ASTM International, West Conshohockem, PA."},{"key":"10.1016\/j.jbiomech.2021.110412_b0010","series-title":"ASTM F2267-04, Standard test method for measuring load induced subsidence of intervertebral body fusion device under static axial compression","author":"ASTM","year":"2018"},{"key":"10.1016\/j.jbiomech.2021.110412_b0015","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1007\/s12178-009-9053-8","article-title":"Comparison of low back fusion techniques: transforaminal lumbar interbody fusion (TLIF) or posterior lumbar interbody fusion (PLIF) approaches","volume":"2","author":"Cole","year":"2009","journal-title":"Curr. Rev. Musculoskeletal Med."},{"key":"10.1016\/j.jbiomech.2021.110412_b0020","doi-asserted-by":"crossref","unstructured":"Deyo, R.A., Mirza, S.K., 2006. Trends and Variations in the Use of Spine Surgery 443, 139-146.","DOI":"10.1097\/01.blo.0000198726.62514.75"},{"key":"10.1016\/j.jbiomech.2021.110412_b0025","doi-asserted-by":"crossref","unstructured":"DiPaola, C.P., Molinari, R.W., 2008. Posterior Lumbar Interbody Fusion 16, 130-139.","DOI":"10.5435\/00124635-200803000-00004"},{"key":"10.1016\/j.jbiomech.2021.110412_b0030","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1016\/j.jbiomech.2018.10.030","article-title":"An in vitro model of impaction during hip arthroplasty","volume":"82","author":"Doyle","year":"2019","journal-title":"J. Biomech."},{"key":"10.1016\/j.jbiomech.2021.110412_b0035","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1007\/s00776-008-1212-z","article-title":"Experimental investigations of the insertion and deformation behavior of press-fit and threaded acetabular cups for total hip replacement","volume":"13","author":"Fritsche","year":"2008","journal-title":"J. Orthopaedic Sci."},{"key":"10.1016\/j.jbiomech.2021.110412_b0040","first-page":"2208","article-title":"Variation in Surgical Decision Making for Degenerative Spinal Disorders","volume":"30","author":"Irwin","year":"2005","journal-title":"Part I: Lumbar Spine"},{"key":"10.1016\/j.jbiomech.2021.110412_b0045","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.spinee.2015.09.038","article-title":"Does impaction of titanium-coated interbody fusion cages into the disc space cause wear debris or delamination?","volume":"16","author":"Kienle","year":"2016","journal-title":"Spine J."},{"key":"10.1016\/j.jbiomech.2021.110412_b0050","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1054\/arth.2002.30412","article-title":"Impact biomechanics and pelvic deformation during insertion of press-fit acetabular cups","volume":"17","author":"Kroeber","year":"2002","journal-title":"J. Arthroplasty"},{"key":"10.1016\/j.jbiomech.2021.110412_b0055","article-title":"Intraoperative impact: characterization and laboratory simulation on composite hip prostheses, Composite materials for implant applications in the human body: characterization and testing","author":"Maharaj","year":"1993","journal-title":"ASTM Int."},{"key":"10.1016\/j.jbiomech.2021.110412_b0060","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.jbiomech.2018.07.022","article-title":"Mechanical performance of lumbar intervertebral body fusion devices: An analysis of data submitted to the Food and Drug Administration","volume":"78","author":"Peck","year":"2018","journal-title":"J. Biomech."},{"key":"10.1016\/j.jbiomech.2021.110412_b0065","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1016\/j.spinee.2018.01.003","article-title":"Impaction durability of porous polyether-ether-ketone (PEEK) and titanium-coated PEEK interbody fusion devices","volume":"18","author":"Torstrick","year":"2018","journal-title":"Spine J."},{"key":"10.1016\/j.jbiomech.2021.110412_b0070","doi-asserted-by":"crossref","first-page":"E10","DOI":"10.3171\/2018.1.FOCUS17724","article-title":"Assessment of cost drivers and cost variation for lumbar interbody fusion procedures using the Value Driven Outcomes database","volume":"44","author":"Twitchell","year":"2018","journal-title":"Neurosurg Focus"},{"key":"10.1016\/j.jbiomech.2021.110412_b0075","unstructured":"West, C., Fryman, J.C., 2008. Year Cadaveric measurement of impact force on total hip arthroplasty surgical instrumentation. In Am. Soc. Biomech. Conference."},{"key":"10.1016\/j.jbiomech.2021.110412_b0080","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1097\/00007632-199904150-00005","article-title":"New in vivo measurements of pressures in the intervertebral disc in daily life","volume":"24","author":"Wilke","year":"1999","journal-title":"Spine"}],"container-title":["Journal of Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021929021001925?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021929021001925?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,19]],"date-time":"2025-09-19T01:31:26Z","timestamp":1758245486000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0021929021001925"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5]]},"references-count":16,"alternative-id":["S0021929021001925"],"URL":"https:\/\/doi.org\/10.1016\/j.jbiomech.2021.110412","relation":{},"ISSN":["0021-9290"],"issn-type":[{"value":"0021-9290","type":"print"}],"subject":[],"published":{"date-parts":[[2021,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Development of an in vitro test method to simulate intra-operative impaction loading on lumbar intervertebral body fusion devices","name":"articletitle","label":"Article Title"},{"value":"Journal of Biomechanics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jbiomech.2021.110412","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"110412"}}