{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T05:44:39Z","timestamp":1790747079534,"version":"4.1.0"},"reference-count":31,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"funder":[{"DOI":"10.13039\/501100001840","name":"Rannis","doi-asserted-by":"publisher","award":["164061-0611"],"award-info":[{"award-number":["164061-0611"]}],"id":[{"id":"10.13039\/501100001840","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Biomechanics"],"published-print":{"date-parts":[[2021,6]]},"DOI":"10.1016\/j.jbiomech.2021.110440","type":"journal-article","created":{"date-parts":[[2021,4,14]],"date-time":"2021-04-14T21:43:25Z","timestamp":1618436605000},"page":"110440","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":38,"special_numbering":"C","title":["Variable stiffness foot design and validation"],"prefix":"10.1016","volume":"122","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6385-8467","authenticated-orcid":false,"given":"Christophe","family":"Lecomte","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna L\u00e1ra","family":"\u00c1rmannsd\u00f3ttir","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5345-3730","authenticated-orcid":false,"given":"Felix","family":"Starker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0789-8338","authenticated-orcid":false,"given":"Heimir","family":"Tryggvason","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0606-991X","authenticated-orcid":false,"given":"Kristin","family":"Briem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sigur\u00f0ur","family":"Brynjolfsson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jbiomech.2021.110440_b0005","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1016\/j.humov.2017.04.005","article-title":"Sensitivity of biomechanical outcomes to independent variations of hindfoot and forefoot stiffness in foot prostheses","volume":"54","author":"Adamczyk","year":"2017","journal-title":"Hum. Mov. Sci."},{"key":"10.1016\/j.jbiomech.2021.110440_b0010","unstructured":"American Orthotic and Prosthetic Association, 2013. AOPA Prosthetic Foot Project Report [WWW Document]. URL https:\/\/www.aopanet.org\/wp-content\/uploads\/2013\/12\/Prosthetic_Foot_Project.pdf (accessed 6.17.20)."},{"key":"10.1016\/j.jbiomech.2021.110440_b0015","doi-asserted-by":"crossref","unstructured":"Cappozzo, a, Catani, F., Della Croce, U., Leardini, A., 1995. Position and orientation in space of bones during movement. Clin. Biomech. 10, 171\u2013178.","DOI":"10.1016\/0268-0033(95)91394-T"},{"key":"10.1016\/j.jbiomech.2021.110440_b0020","first-page":"1","article-title":"Body Segment Parameters","volume":"16","author":"Contini","year":"1972","journal-title":"Part II. Artif. Limbs"},{"key":"10.1016\/j.jbiomech.2021.110440_b0025","doi-asserted-by":"crossref","unstructured":"Fey, N.P., Klute, G.K., Neptune, R.R., 2011. The influence of energy storage and return foot stiffness on walking mechanics and muscle activity in below-knee amputees. Clin. Biomech. (Bristol, Avon) 26, 1025\u201332. https:\/\/doi.org\/10.1016\/j.clinbiomech.2011.06.007","DOI":"10.1016\/j.clinbiomech.2011.06.007"},{"key":"10.1016\/j.jbiomech.2021.110440_b0030","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1097\/00008526-200109000-00011","article-title":"Energy Loss and Stiffness Properties of Dynamic Elastic Response Prosthetic Feet","volume":"13","author":"Geil","year":"2001","journal-title":"JPO J. Prosthetics Orthot."},{"key":"10.1016\/j.jbiomech.2021.110440_b0035","unstructured":"Glanzer, E.M., Adamczyk, P.G., Member, I., 2018. Design and Validation of a Semi-Active Variable Stiffness Foot Prosthesis 1\u20139."},{"key":"10.1016\/j.jbiomech.2021.110440_b0040","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/j.gaitpost.2010.04.014","article-title":"Effective rocker shapes used by able-bodied persons for walking and fore-aft swaying: implications for design of ankle-foot prostheses","volume":"32","author":"Hansen","year":"2010","journal-title":"Gait Posture"},{"key":"10.1016\/j.jbiomech.2021.110440_b0045","article-title":"Mechanical and dynamic characterization of prosthetic feet for high activity users during weighted and unweighted walking","volume":"1\u201316","author":"Koehler-McNicholas","year":"2018","journal-title":"PLoS One"},{"key":"10.1016\/j.jbiomech.2021.110440_b0050","article-title":"transfemoral amputee physiological requirements: Comparison Between SACH Foot Walking and Flex-Foot Walking","author":"MacFarlane","year":"1997","journal-title":"J. Prosthetics Orthot."},{"key":"10.1016\/j.jbiomech.2021.110440_b0055","doi-asserted-by":"crossref","unstructured":"MacFarlane, P.., D.H, N., D.G, S., Meier, K., 1991. Perception of Walking Difficulty by Below-Knee Amputees Using a Conventional Foot Versus the Flex-Foot. Prosthet. Orthot. Int.","DOI":"10.1097\/00008526-199106000-00007"},{"key":"10.1016\/j.jbiomech.2021.110440_b0060","article-title":"The effects of common footwear on stance-phase mechanical properties of the prosthetic foot-shoe system","author":"Major","year":"2017","journal-title":"Prosthet. Orthot. Int."},{"key":"10.1016\/j.jbiomech.2021.110440_b0065","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1007\/s00158-008-0291-y","article-title":"Uniform strength for large deflections of cantilever beams under end point load","volume":"38","author":"Oore","year":"2008","journal-title":"Struct. Multidiscip. Optim."},{"key":"10.1016\/j.jbiomech.2021.110440_b0070","unstructured":"\u00d6ssur Pro-Flex LP [WWW Document], 2020. URL https:\/\/www.ossur.com\/en-gb\/prosthetics\/feet\/pro-flex-lp (accessed 4.13.20)."},{"key":"10.1016\/j.jbiomech.2021.110440_b0075","unstructured":"Ottobock Empower [WWW Document], 2020. URL https:\/\/www.ottobockus.com\/prosthetics\/lower-limb-prosthetics\/solution-overview\/empower-ankle\/ (accessed 4.10.20)."},{"key":"10.1016\/j.jbiomech.2021.110440_b0080","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.apmr.2005.11.026","article-title":"Advances in amputee care","volume":"87","author":"Pasquina","year":"2006","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"10.1016\/j.jbiomech.2021.110440_b0085","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.medengphy.2017.07.002","article-title":"Second generation prototype of a variable stiffness transverse plane adapter for a lower limb prosthesis","volume":"49","author":"Pew","year":"2017","journal-title":"Med. Eng. Phys."},{"key":"10.1016\/j.jbiomech.2021.110440_b0090","first-page":"1","article-title":"Design of lower limb prosthesis transverse plane adaptor with variable stiffness. J. Med. Devices","volume":"9","author":"Pew","year":"2015","journal-title":"Trans. ASME"},{"key":"10.1016\/j.jbiomech.2021.110440_b0095","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1097\/00002060-200101000-00007","article-title":"Muscle power compensatory mechanisms in below-knee amputee gait","volume":"80","author":"Sadeghi","year":"2001","journal-title":"Am. J. Phys. Med. Rehabil."},{"key":"10.1016\/j.jbiomech.2021.110440_b0100","article-title":"A more compliant prosthetic foot better accommodates added load while walking among Servicemembers with transtibial limb loss","volume":"109395","author":"Schnall","year":"2019","journal-title":"J. Biomech."},{"key":"10.1016\/j.jbiomech.2021.110440_b0105","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.clinbiomech.2017.08.003","article-title":"The effects of prosthetic foot stiffness on transtibial amputee walking mechanics and balance control during turning","volume":"49","author":"Shell","year":"2017","journal-title":"Clin. Biomech."},{"key":"10.1016\/j.jbiomech.2021.110440_b0110","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12984-018-0432-5","article-title":"Amputee perception of prosthetic ankle stiffness during locomotion","volume":"15","author":"Shepherd","year":"2018","journal-title":"J. Neuroeng. Rehabil."},{"key":"10.1016\/j.jbiomech.2021.110440_b0115","doi-asserted-by":"crossref","unstructured":"Shepherd, Max K, Member, S., Azocar, A.F., Member, S., Matthew, J., Rouse, E.J., 2018. The Just Noticeable Difference of Ankle - Foot Prosthesis Stiffness for Persons with Transtibial Amputation.","DOI":"10.1109\/BIOROB.2018.8488075"},{"key":"10.1016\/j.jbiomech.2021.110440_b0120","first-page":"6672","article-title":"Design of a quasi-passive ankle-foot prosthesis with biomimetic, variable stiffness","author":"Shepherd","year":"2017","journal-title":"Proc. - IEEE Int. Conf. Robot. Autom."},{"key":"10.1016\/j.jbiomech.2021.110440_b0125","doi-asserted-by":"crossref","first-page":"2375","DOI":"10.1109\/TNSRE.2017.2750113","article-title":"The VSPA Foot: A Quasi-Passive Ankle-Foot Prosthesis with Continuously Variable Stiffness","volume":"25","author":"Shepherd","year":"2017","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"10.1016\/j.jbiomech.2021.110440_b0130","doi-asserted-by":"crossref","unstructured":"Tryggvason, H., Starker, F., Lecomte, C., Jonsdottir, F., 2020. Use of Dynamic FEA for Design Modification and Energy Analysis of a Variable Stiffness Prosthetic Foot.","DOI":"10.3390\/app10020650"},{"key":"10.1016\/j.jbiomech.2021.110440_b0135","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1016\/j.clinbiomech.2004.02.005","article-title":"A comparison of two prosthetic feet on the multi-joint and multi-plane kinetic gait compensations in individuals with a unilateral trans-tibial amputation","volume":"19","author":"Underwood","year":"2004","journal-title":"Clin. Biomech."},{"key":"10.1016\/j.jbiomech.2021.110440_b0140","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1016\/j.gaitpost.2010.11.009","article-title":"The effect of prosthetic ankle energy storage and return properties on muscle activity in below-knee amputee walking","volume":"33","author":"Ventura","year":"2011","journal-title":"Gait Posture"},{"key":"10.1016\/j.jbiomech.2021.110440_b0145","doi-asserted-by":"crossref","unstructured":"Warder, H.H., Iii, J.K.F., Coutts, J., Glisson, R.R., Gall, K., 2018. Examining the viability of carbon fiber reinforced three-dimensionally printed prosthetic feet created by composite filament fabrication 1\u20138. https:\/\/doi.org\/10.1177\/0309364618785726","DOI":"10.1177\/0309364618785726"},{"key":"10.1016\/j.jbiomech.2021.110440_b0150","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/S0966-6362(99)00009-0","article-title":"The energy expenditure of normal and pathologic gait","volume":"9","author":"Waters","year":"1999","journal-title":"Gait Posture"},{"key":"10.1016\/j.jbiomech.2021.110440_b0155","article-title":"Adaptive Foot in Lower-Limb Prostheses","volume":"2017","author":"Weerakkody","year":"2017","journal-title":"J. Robot."}],"container-title":["Journal of Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021929021002207?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021929021002207?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,3]],"date-time":"2025-11-03T17:04:26Z","timestamp":1762189466000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0021929021002207"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6]]},"references-count":31,"alternative-id":["S0021929021002207"],"URL":"https:\/\/doi.org\/10.1016\/j.jbiomech.2021.110440","relation":{},"ISSN":["0021-9290"],"issn-type":[{"value":"0021-9290","type":"print"}],"subject":[],"published":{"date-parts":[[2021,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Variable stiffness foot design and validation","name":"articletitle","label":"Article Title"},{"value":"Journal of Biomechanics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jbiomech.2021.110440","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}],"article-number":"110440"}}