{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T06:45:24Z","timestamp":1793774724942,"version":"4.6.1"},"reference-count":12,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2022,5,24]],"date-time":"2022-05-24T00:00:00Z","timestamp":1653350400000},"content-version":"am","delay-in-days":357,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100000005","name":"US Department of Defense","doi-asserted-by":"publisher","award":["W81XWH-16-1-0010"],"award-info":[{"award-number":["W81XWH-16-1-0010"]}],"id":[{"id":"10.13039\/100000005","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100006282","name":"Federal Aviation Administration","doi-asserted-by":"publisher","award":["13-G-005"],"award-info":[{"award-number":["13-G-005"]}],"id":[{"id":"10.13039\/100006282","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Biomechanics"],"published-print":{"date-parts":[[2021,6]]},"DOI":"10.1016\/j.jbiomech.2021.110537","type":"journal-article","created":{"date-parts":[[2021,5,15]],"date-time":"2021-05-15T19:51:51Z","timestamp":1621108311000},"page":"110537","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"special_numbering":"C","title":["A novel posture control device to induce high-rate complex loads for spine biomechanical studies"],"prefix":"10.1016","volume":"123","author":[{"given":"John","family":"Humm","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Narayan","family":"Yoganandan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"DeRosia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Klaus","family":"Driesslein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph","family":"Avila","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frank","family":"Pintar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jbiomech.2021.110537_b0005","doi-asserted-by":"crossref","first-page":"3407","DOI":"10.1016\/j.jbiomech.2016.09.009","article-title":"The effect of six degree of freedom loading sequence on the in-vitro compressive properties of human lumbar spine segments","volume":"49","author":"Amin","year":"2016","journal-title":"J. Biomech."},{"key":"10.1016\/j.jbiomech.2021.110537_b0010","series-title":"Accidental Injury: Biomechanics and Prevention","first-page":"811","article-title":"Civil avaition crash injury protection","author":"DeWeese","year":"2015"},{"key":"10.1016\/j.jbiomech.2021.110537_b0015","unstructured":"FMVSS-208, 2001. FMVSS 208: 49Code of Federal Regulations: 571.208. US Government Printing Office, Washington, DC."},{"key":"10.1016\/j.jbiomech.2021.110537_b0020","first-page":"135","article-title":"Responses and Injuries to PMHS in Side-Facing and Oblique Seats in Horizontal Longitudinal Sled Tests per FAA Emergency Landing Conditions","volume":"60","author":"Humm","year":"2016","journal-title":"Stapp Car Crash J."},{"key":"10.1016\/j.jbiomech.2021.110537_b0025","first-page":"13","article-title":"Seating Positions and Activities in Highly Automated Cars \u2013 A Qualitative Study of Future Automated Driving Scenarios","author":"Jorl\u00f6v","year":"2017","journal-title":"IRCOBI"},{"key":"10.1016\/j.jbiomech.2021.110537_b0030","first-page":"57","article-title":"Preinjury cervical alignment affecting spinal trauma","volume":"97","author":"Maiman","year":"2002","journal-title":"J. Neurosurg."},{"key":"10.1016\/j.jbiomech.2021.110537_b0035","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1016\/j.jbiomech.2015.10.035","article-title":"Fundamental biomechanics of the spine\u2013What we have learned in the past 25 years and future directions","volume":"49","author":"Oxland","year":"2016","journal-title":"J. Biomech."},{"key":"10.1016\/j.jbiomech.2021.110537_b0040","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1016\/S0736-0266(02)00202-4","article-title":"Effect of compressive follower preload on the flexion-extension response of the human lumbar spine","volume":"21","author":"Patwardhan","year":"2003","journal-title":"J. Orthop. Res."},{"key":"10.1016\/j.jbiomech.2021.110537_b0045","doi-asserted-by":"crossref","unstructured":"Prasad, P., 2015. Injury criteria and motor vehicle regulations, Accidental Injury: Biomechanics and Prevention, third ed. Springer, NY, pp. 793\u2013809.","DOI":"10.1007\/978-1-4939-1732-7_27"},{"key":"10.1016\/j.jbiomech.2021.110537_b0050","series-title":"The Seated Soldier Study: Posture and Body Shape in Vehicle Seats","author":"Reed","year":"2014"},{"key":"10.1016\/j.jbiomech.2021.110537_b0055","doi-asserted-by":"crossref","first-page":"1363","DOI":"10.1007\/s00586-016-4416-5","article-title":"A new dynamic six degrees of freedom disc-loading simulator allows to provoke disc damage and herniation","volume":"25","author":"Wilke","year":"2016","journal-title":"Eur. Spine J."},{"key":"10.1016\/j.jbiomech.2021.110537_b0060","doi-asserted-by":"crossref","unstructured":"Yoganandan, N., Cusick, J.F., Pintar, F.A., Droese, K., Reinartz, J., 1994. Cyclic compression-flexion loading of the human lumbar spine. Spine (Phila Pa 1976) 19, 784\u2013790 (discussion 791).","DOI":"10.1097\/00007632-199404000-00010"}],"container-title":["Journal of Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021929021003183?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021929021003183?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,3]],"date-time":"2025-11-03T17:04:56Z","timestamp":1762189496000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0021929021003183"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6]]},"references-count":12,"alternative-id":["S0021929021003183"],"URL":"https:\/\/doi.org\/10.1016\/j.jbiomech.2021.110537","relation":{},"ISSN":["0021-9290"],"issn-type":[{"value":"0021-9290","type":"print"}],"subject":[],"published":{"date-parts":[[2021,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A novel posture control device to induce high-rate complex loads for spine biomechanical studies","name":"articletitle","label":"Article Title"},{"value":"Journal of Biomechanics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jbiomech.2021.110537","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"110537"}}