{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T07:43:32Z","timestamp":1782287012531,"version":"3.54.5"},"reference-count":16,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2023,6,1]],"date-time":"2023-06-01T00:00:00Z","timestamp":1685577600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,6,1]],"date-time":"2023-06-01T00:00:00Z","timestamp":1685577600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,5,11]],"date-time":"2023-05-11T00:00:00Z","timestamp":1683763200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.com.au","clinicalkey.es","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Biomechanics"],"published-print":{"date-parts":[[2023,6]]},"DOI":"10.1016\/j.jbiomech.2023.111635","type":"journal-article","created":{"date-parts":[[2023,5,15]],"date-time":"2023-05-15T10:36:39Z","timestamp":1684146999000},"page":"111635","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":8,"special_numbering":"C","title":["Resisting subsidence with a truss Implant: Application of the \u201cSnowshoe\u201d principle for interbody fusion devices"],"prefix":"10.1016","volume":"155","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7837-9191","authenticated-orcid":false,"given":"Ali","family":"Kiapour","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elie","family":"Massaad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manoj K.","family":"Kodigudla","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amey","family":"Kelkar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew R.","family":"Begley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vijay K.","family":"Goel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jon E.","family":"Block","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John H.","family":"Shin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jbiomech.2023.111635_b0005","doi-asserted-by":"crossref","first-page":"2377","DOI":"10.1007\/s00586-021-06912-2","article-title":"Evaluation of cage subsidence in standalone lateral lumbar interbody fusion: novel 3D-printed titanium versus polyetheretherketone (PEEK) cage","volume":"30","author":"Adl Amini","year":"2021","journal-title":"Eur. Spine J."},{"key":"10.1016\/j.jbiomech.2023.111635_b0010","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3171\/2020.1.SPINE19776","article-title":"Impact of endplate-implant area mismatch on rates and grades of subsidence following stand-alone lateral lumbar interbody fusion: an analysis of 623 levels","volume":"33","author":"Agarwal","year":"2020","journal-title":"J. Neurosurg. Spine"},{"key":"10.1016\/j.jbiomech.2023.111635_b0015","doi-asserted-by":"crossref","first-page":"4090","DOI":"10.1016\/j.jbiomech.2016.10.051","article-title":"Ex vivo loading of trussed implants for spine fusion induces heterogeneous strains consistent with homeostatic bone mechanobiology","volume":"49","author":"Caffrey","year":"2016","journal-title":"J. Biomech."},{"key":"10.1016\/j.jbiomech.2023.111635_b0020","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/j.cmpb.2018.05.022","article-title":"Stand-alone lumbar cage subsidence: A biomechanical sensitivity study of cage design and placement","volume":"162","author":"Calvo-Echenique","year":"2018","journal-title":"Comput. Methods Programs Biomed."},{"key":"10.1016\/j.jbiomech.2023.111635_b0025","doi-asserted-by":"crossref","first-page":"757","DOI":"10.21037\/jss.2018.12.01","article-title":"3-dimensional printing for anterior cervical surgery: a review","volume":"4","author":"Choy","year":"2018","journal-title":"J. Spine Surg."},{"key":"10.1016\/j.jbiomech.2023.111635_b0030","doi-asserted-by":"crossref","DOI":"10.1115\/1.4046584","article-title":"Subsidence of additively-manufactured cages in foam substrates: Effect of contact topology","volume":"142","author":"Collino","year":"2020","journal-title":"J. Biomech. Eng."},{"key":"10.1016\/j.jbiomech.2023.111635_b0035","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2018\/4760769","article-title":"3D printing applications in minimally invasive spine surgery","volume":"2018","author":"Hsu","year":"2018","journal-title":"Minim. Invasive Surg."},{"key":"10.1016\/j.jbiomech.2023.111635_b0040","doi-asserted-by":"crossref","first-page":"S286","DOI":"10.21037\/jss.2019.09.25","article-title":"Subsidence induced recurrent radiculopathy after staged two-level standalone endoscopic lumbar interbody fusion with a threaded cylindrical cage: a case report","volume":"6","author":"Lewandrowski","year":"2020","journal-title":"J. Spine Surg."},{"key":"10.1016\/j.jbiomech.2023.111635_b0045","doi-asserted-by":"crossref","first-page":"2389","DOI":"10.1097\/01.brs.0000143623.18098.e5","article-title":"A biomechanical study of regional endplate strength and cage morphology as it relates to structural interbody support","volume":"29","author":"Lowe","year":"2004","journal-title":"Spine"},{"key":"10.1016\/j.jbiomech.2023.111635_b0050","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1016\/j.wneu.2018.11.121","article-title":"Subsidence rates after lateral lumbar interbody fusion: A Systematic Review","volume":"122","author":"Macki","year":"2019","journal-title":"World Neurosurg."},{"key":"10.1016\/j.jbiomech.2023.111635_b0055","first-page":"1999","article-title":"Next-generation biomedical implants using additive manufacturing of complex, cellular and functional mesh arrays","volume":"368","author":"Murr","year":"2010","journal-title":"Philos. Trans. A Math. Phys. Eng. Sci."},{"key":"10.1016\/j.jbiomech.2023.111635_b0060","doi-asserted-by":"crossref","first-page":"1131","DOI":"10.1007\/s00586-020-06348-0","article-title":"Endplate volumetric bone mineral density measured by quantitative computed tomography as a novel predictive measure of severe cage subsidence after standalone lateral lumbar fusion","volume":"29","author":"Okano","year":"2020","journal-title":"Eur. Spine J."},{"key":"10.1016\/j.jbiomech.2023.111635_b0065","doi-asserted-by":"crossref","first-page":"168","DOI":"10.21037\/jss.2017.05.03","article-title":"Subsidence following anterior lumbar interbody fusion (ALIF): a prospective study","volume":"3","author":"Rao","year":"2017","journal-title":"J. Spine Surg."},{"key":"10.1016\/j.jbiomech.2023.111635_b0070","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1186\/s12891-021-04244-2","article-title":"A lattice topology optimization of cervical interbody fusion cage and finite element comparison with ZK60 and Ti-6Al-4V cages","volume":"22","author":"Sun","year":"2021","journal-title":"BMC Musculoskelet. Disord."},{"key":"10.1016\/j.jbiomech.2023.111635_b0075","doi-asserted-by":"crossref","unstructured":"Tan, J.-S., Bailey, C.S., Dvorak, M.F., Fisher, C.G., Oxland, T.R., 2005. Interbody device shape and size are important to strengthen the vertebra-implant interface. Spine (Phila. Pa. 1976) 30, 638\u2013644.","DOI":"10.1097\/01.brs.0000155419.24198.35"},{"key":"10.1016\/j.jbiomech.2023.111635_b0080","doi-asserted-by":"crossref","first-page":"433","DOI":"10.21037\/jss.2017.09.01","article-title":"Systematic review of 3D printing in spinal surgery: the current state of play","volume":"3","author":"Wilcox","year":"2017","journal-title":"J. Spine Surg."}],"container-title":["Journal of Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S002192902300204X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S002192902300204X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,1,8]],"date-time":"2025-01-08T16:39:21Z","timestamp":1736354361000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S002192902300204X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6]]},"references-count":16,"alternative-id":["S002192902300204X"],"URL":"https:\/\/doi.org\/10.1016\/j.jbiomech.2023.111635","relation":{},"ISSN":["0021-9290"],"issn-type":[{"value":"0021-9290","type":"print"}],"subject":[],"published":{"date-parts":[[2023,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Resisting subsidence with a truss Implant: Application of the \u201cSnowshoe\u201d principle for interbody fusion devices","name":"articletitle","label":"Article Title"},{"value":"Journal of Biomechanics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jbiomech.2023.111635","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Author(s). Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"111635"}}