{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T19:36:49Z","timestamp":1790797009216,"version":"4.1.0"},"reference-count":37,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["12072214"],"award-info":[{"award-number":["12072214"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Biomechanics"],"published-print":{"date-parts":[[2024,1]]},"DOI":"10.1016\/j.jbiomech.2024.111937","type":"journal-article","created":{"date-parts":[[2024,1,9]],"date-time":"2024-01-09T12:06:12Z","timestamp":1704801972000},"page":"111937","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"special_numbering":"C","title":["A streamlined controlled-expansion covered tapered stent for TIPS in the treatment of PHT"],"prefix":"10.1016","volume":"163","author":[{"given":"Zhuxiang","family":"Xiong","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoze","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuling","family":"Yan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhan","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuefeng","family":"Luo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0597-3245","authenticated-orcid":false,"given":"Tinghui","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"8","key":"10.1016\/j.jbiomech.2024.111937_b0005","doi-asserted-by":"crossref","first-page":"1636-+","DOI":"10.1016\/j.cgh.2021.07.018","article-title":"North American Practice-Based Recommendations for Transjugular Intrahepatic Portosystemic Shunts in Portal Hypertension","volume":"20","author":"Boike","year":"2022","journal-title":"Clin. Gastroenterol. Hepatol."},{"issue":"1","key":"10.1016\/j.jbiomech.2024.111937_b0010","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1016\/j.jhep.2020.09.018","article-title":"Small diameter shunts should lead to safe expansion of the use of TIPS","volume":"74","author":"Bosch","year":"2021","journal-title":"J. Hepatol."},{"issue":"10","key":"10.1016\/j.jbiomech.2024.111937_b0015","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1038\/nrgastro.2009.149","article-title":"The clinical use of HVPG measurements in chronic liver disease","volume":"6","author":"Bosch","year":"2009","journal-title":"Nat. Rev. Gastroenterol. Hepatol."},{"issue":"2","key":"10.1016\/j.jbiomech.2024.111937_b0020","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1002\/hep.20037","article-title":"Changing clinical practice with measurements of portal pressure","volume":"39","author":"Boyer","year":"2004","journal-title":"Hepatology"},{"issue":"1","key":"10.1016\/j.jbiomech.2024.111937_b0025","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1002\/hep.23383","article-title":"Role of transjugular intrahepatic portosystemic shunt (TIPS) in the management of portal hypertension: update 2009","volume":"51","author":"Boyer","year":"2010","journal-title":"Hepatology"},{"issue":"2","key":"10.1016\/j.jbiomech.2024.111937_b0030","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1053\/j.gastro.2003.11.016","article-title":"Improved clinical outcome using polytetrafluoroethylene-coated stents for TIPS: results of a randomized study","volume":"126","author":"Bureau","year":"2004","journal-title":"Gastroenterology"},{"issue":"4","key":"10.1016\/j.jbiomech.2024.111937_b0035","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1053\/j.tvir.2009.04.003","article-title":"Management of shunt dysfunction in the era of TIPS endografts","volume":"11","author":"Clark","year":"2008","journal-title":"Tech. Vasc. Interv. Radiol."},{"issue":"5","key":"10.1016\/j.jbiomech.2024.111937_b0040","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1097\/MCA.0000000000000253","article-title":"Current developments and future applications of intracoronary hemodynamics","volume":"26","author":"Coverstone","year":"2015","journal-title":"Coron. Artery Dis."},{"issue":"3","key":"10.1016\/j.jbiomech.2024.111937_b0045","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1016\/j.jhep.2015.05.022","article-title":"Expanding consensus in portal hypertension: Report of the Baveno VI Consensus Workshop: Stratifying risk and individualizing care for portal hypertension","volume":"63","author":"de Franchis","year":"2015","journal-title":"J. Hepatol."},{"issue":"13","key":"10.1016\/j.jbiomech.2024.111937_b0050","doi-asserted-by":"crossref","first-page":"1438","DOI":"10.1080\/10255842.2017.1370460","article-title":"Flow visualisation study of spiral flow in the aorta-renal bifurcation","volume":"20","author":"Fulker","year":"2017","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"issue":"9","key":"10.1016\/j.jbiomech.2024.111937_b0055","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1056\/NEJMra0901512","article-title":"Current concepts: management of varices and variceal hemorrhage in cirrhosis","volume":"362","author":"Garcia-Tsao","year":"2010","journal-title":"N. Engl. J. Med."},{"issue":"1","key":"10.1016\/j.jbiomech.2024.111937_b0060","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1007\/s13239-014-0195-5","article-title":"Hemodynamics in normal and diseased livers: application of image-based computational models","volume":"6","author":"George","year":"2015","journal-title":"Cardiovasc. Eng. Technol."},{"issue":"8","key":"10.1016\/j.jbiomech.2024.111937_b0065","doi-asserted-by":"crossref","first-page":"1729","DOI":"10.1161\/01.ATV.0000229658.76797.30","article-title":"Flow effects on coagulation and thrombosis","volume":"26","author":"Hathcock","year":"2006","journal-title":"Arterioscler. Thromb. Vasc. Biol."},{"issue":"5","key":"10.1016\/j.jbiomech.2024.111937_b0070","doi-asserted-by":"crossref","first-page":"996","DOI":"10.1016\/j.gie.2016.09.026","article-title":"EUS-guided portal pressure gradient measurement with a simple novel device: a human pilot study","volume":"85","author":"Huang","year":"2017","journal-title":"Gastrointest. Endosc."},{"issue":"4","key":"10.1016\/j.jbiomech.2024.111937_b0075","first-page":"623","article-title":"Transjugular intrahepatic portosystemic shunt: a meta-analysis of 8 mm versus 10 mm stents","volume":"16","author":"Huang","year":"2021","journal-title":"Wideochir Inne Tech Maloinwazyjne"},{"issue":"1","key":"10.1016\/j.jbiomech.2024.111937_b0080","doi-asserted-by":"crossref","first-page":"11","DOI":"10.12891\/ceog1675.2015","article-title":"The application of high definition flow imaging in fetal hemodynamics","volume":"42","author":"Li","year":"2015","journal-title":"Clin. Exp. Obstet. Gynecol."},{"key":"10.1016\/j.jbiomech.2024.111937_b0085","first-page":"S233","article-title":"Computational hemodynamics of portal vein hypertension in hepatic cirrhosis patients","volume":"26","author":"Li","year":"2015","journal-title":"Biomed. Mater. Eng."},{"key":"10.1016\/j.jbiomech.2024.111937_b0090","doi-asserted-by":"crossref","unstructured":"Liu, J., Wehrenberg-Klee, E.P., Bethea, E.D., Uppot, R.N., Yamada, K., Ganguli, S., 2020. Transjugular Intrahepatic Portosystemic Shunt Placement for Portal Hypertension: Meta-Analysis of Safety and Efficacy of 8 mm vs. 10 mm Stents. Gastroenterol Res Pract, 2020, 9149065. doi: 10.1155\/2020\/9149065.","DOI":"10.1155\/2020\/9149065"},{"issue":"6","key":"10.1016\/j.jbiomech.2024.111937_b0095","doi-asserted-by":"crossref","first-page":"e00376","DOI":"10.14309\/ctg.0000000000000376","article-title":"Potential benefits of underdilation of 8-mm covered stent in transjugular intrahepatic portosystemic shunt creation","volume":"12","author":"Liu","year":"2021","journal-title":"Clin. Transl. Gastroenterol."},{"issue":"6","key":"10.1016\/j.jbiomech.2024.111937_b0100","doi-asserted-by":"crossref","first-page":"835","DOI":"10.1016\/j.jvir.2014.11.041","article-title":"Segmental liver ischemia\/infarction after elective transjugular intrahepatic portosystemic shunt creation: clinical outcomes in 10 patients","volume":"26","author":"Lopera","year":"2015","journal-title":"J. Vasc. Interv. Radiol."},{"key":"10.1016\/j.jbiomech.2024.111937_b0105","doi-asserted-by":"crossref","DOI":"10.1016\/j.cmpb.2021.106242","article-title":"Virtual ABI: a computationally derived ABI index for noninvasive assessment of femoro-popliteal bypass surgery outcome","volume":"208","author":"Milasinovic","year":"2021","journal-title":"Comput. Methods Programs Biomed."},{"issue":"1","key":"10.1016\/j.jbiomech.2024.111937_b0110","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1007\/s00270-018-2040-y","article-title":"Transjugular intrahepatic portosystemic shunt using the new gore viatorr controlled expansion endoprosthesis: prospective, single-center, preliminary experience","volume":"42","author":"Miraglia","year":"2019","journal-title":"Cardiovasc. Intervent. Radiol."},{"key":"10.1016\/j.jbiomech.2024.111937_b0115","unstructured":"Munson, B.R., Okiishi, T.H., Huebsch, W.W., Rothmayer, A.., 2012. Fundamentals of Fluid Mechanics, Student Solutions Manual and Study Guide."},{"issue":"1","key":"10.1016\/j.jbiomech.2024.111937_b0120","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1097\/MAT.0b013e31815d6898","article-title":"Platelet activation due to hemodynamic shear stresses: Damage accumulation model and comparison to measurements","volume":"54","author":"Nobili","year":"2008","journal-title":"ASAIO J."},{"issue":"4","key":"10.1016\/j.jbiomech.2024.111937_b0125","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1016\/j.bpa.2021.01.005","article-title":"Application of perioperative hemodynamics today and potentials for tomorrow","volume":"35","author":"Ramsingh","year":"2021","journal-title":"Best Pract. Res. Clin. Anaesthesiol."},{"issue":"3","key":"10.1016\/j.jbiomech.2024.111937_b0130","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1007\/BF02282344","article-title":"Hepatic encephalopathy after transjugular intrahepatic portosystemic shunt - Incidence and risk factors","volume":"41","author":"Riggio","year":"1996","journal-title":"Dig. Dis. Sci."},{"issue":"7","key":"10.1016\/j.jbiomech.2024.111937_b0135","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1161\/CIRCULATIONAHA.111.021824","article-title":"Coronary artery wall shear stress is associated with progression and transformation of atherosclerotic plaque and arterial remodeling in patients with coronary artery disease","volume":"124","author":"Samady","year":"2011","journal-title":"Circulation"},{"issue":"7","key":"10.1016\/j.jbiomech.2024.111937_b0140","doi-asserted-by":"crossref","first-page":"1153","DOI":"10.1016\/j.cgh.2018.01.029","article-title":"Under-dilated TIPS associate with efficacy and reduced encephalopathy in a prospective, non-randomized study of patients with cirrhosis","volume":"16","author":"Schepis","year":"2018","journal-title":"Clin. Gastroenterol. Hepatol."},{"issue":"4","key":"10.1016\/j.jbiomech.2024.111937_b0145","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1007\/s13239-019-00437-y","article-title":"Haemodynamics study of tapered stents intervention to tapered arteries","volume":"10","author":"Shen","year":"2019","journal-title":"Cardiovasc. Eng. Technol."},{"issue":"4","key":"10.1016\/j.jbiomech.2024.111937_b0150","doi-asserted-by":"crossref","first-page":"1442","DOI":"10.1007\/s10439-010-9936-2","article-title":"High-shear stress sensitizes platelets to subsequent low-shear conditions","volume":"38","author":"Sheriff","year":"2010","journal-title":"Ann. Biomed. Eng."},{"issue":"3","key":"10.1016\/j.jbiomech.2024.111937_b0155","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1007\/s00270-017-1807-x","article-title":"Transjugular intrahepatic portosystemic shunt reduction using the GORE VIATORR controlled expansion endoprosthesis: hemodynamics of reducing an established 10-mm TIPS to 8-mm in diameter","volume":"41","author":"Srinivasa","year":"2018","journal-title":"Cardiovasc. Intervent. Radiol."},{"key":"10.1016\/j.jbiomech.2024.111937_b0160","doi-asserted-by":"crossref","unstructured":"Wang, K.X., Wang, S., Xiong, M.H., Wang, C.Y., Wang, H., 2021. Non-invasive Assessment of Hepatic Venous Pressure Gradient (HVPG) Based on MR Flow Imaging and Computational Fluid Dynamics. Medical Image Computing and Computer Assisted Intervention - Miccai 2021, Pt Vii, 12907, 33-42. doi: 10.1007\/978-3-030-87234-2_4.","DOI":"10.1007\/978-3-030-87234-2_4"},{"issue":"3","key":"10.1016\/j.jbiomech.2024.111937_b0165","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1016\/j.jhep.2017.05.006","article-title":"Eight millimetre covered TIPS does not compromise shunt function but reduces hepatic encephalopathy in preventing variceal rebleeding","volume":"67","author":"Wang","year":"2017","journal-title":"J. Hepatol."},{"key":"10.1016\/j.jbiomech.2024.111937_b0170","doi-asserted-by":"crossref","DOI":"10.1186\/s12938-016-0259-x","article-title":"Hemodynamic analysis of sequential graft from right coronary system to left coronary system","volume":"15","author":"Wang","year":"2016","journal-title":"Biomed. Eng. Online"},{"issue":"5","key":"10.1016\/j.jbiomech.2024.111937_b0175","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1097\/MAT.0b013e3182246e0a","article-title":"A comparative study of helical-type and traditional-type artery bypass grafts: numerical simulation","volume":"57","author":"Wen","year":"2011","journal-title":"ASAIO J."},{"key":"10.1016\/j.jbiomech.2024.111937_b0180","doi-asserted-by":"crossref","DOI":"10.1002\/mp.16481","article-title":"The effect of splenic vein diameter on the diagnosis of portal vein thrombosis","author":"Xiong","year":"2023","journal-title":"Med. Phys."},{"key":"10.1016\/j.jbiomech.2024.111937_b0185","doi-asserted-by":"crossref","DOI":"10.1016\/j.jbiomech.2022.111303","article-title":"Computational hemodynamic analysis for optimal stent position in the transjugular intrahepatic portosystemic shunt procedure","volume":"143","author":"Yin","year":"2022","journal-title":"J. Biomech."}],"container-title":["Journal of Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021929024000149?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021929024000149?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,19]],"date-time":"2025-09-19T01:44:03Z","timestamp":1758246243000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0021929024000149"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1]]},"references-count":37,"alternative-id":["S0021929024000149"],"URL":"https:\/\/doi.org\/10.1016\/j.jbiomech.2024.111937","relation":{},"ISSN":["0021-9290"],"issn-type":[{"value":"0021-9290","type":"print"}],"subject":[],"published":{"date-parts":[[2024,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A streamlined controlled-expansion covered tapered stent for TIPS in the treatment of PHT","name":"articletitle","label":"Article Title"},{"value":"Journal of Biomechanics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jbiomech.2024.111937","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}],"article-number":"111937"}}