{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T12:11:34Z","timestamp":1793707894480,"version":"4.6.1"},"reference-count":41,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T00:00:00Z","timestamp":1775001600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T00:00:00Z","timestamp":1775001600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,1,29]],"date-time":"2026-01-29T00:00:00Z","timestamp":1769644800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Biomechanics"],"published-print":{"date-parts":[[2026,4]]},"DOI":"10.1016\/j.jbiomech.2026.113187","type":"journal-article","created":{"date-parts":[[2026,1,25]],"date-time":"2026-01-25T06:50:57Z","timestamp":1769323857000},"page":"113187","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"special_numbering":"C","title":["The use of residual lower limb \u2013prosthetic socket interface pressure measurements to inform clinical decisions: A systematic review"],"prefix":"10.1016","volume":"199","author":[{"given":"Lucy","family":"Armitage","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-7576-6796","authenticated-orcid":false,"given":"Kenny","family":"Cho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tawnee L.","family":"Sparling","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Todd","family":"Sleeman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gursel","family":"Alici","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manish","family":"Sreenivasa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"9\u201310","key":"10.1016\/j.jbiomech.2026.113187_b0005","doi-asserted-by":"crossref","first-page":"994","DOI":"10.1016\/j.clinbiomech.2013.09.004","article-title":"Interface pressure in transtibial socket during ascent and descent on stairs and its effect on patient satisfaction","volume":"28","author":"Ali","year":"2013","journal-title":"Clin. Biomech. (Bristol, Avon)"},{"issue":"7","key":"10.1016\/j.jbiomech.2026.113187_b0010","doi-asserted-by":"crossref","first-page":"3778","DOI":"10.3390\/s23073778","article-title":"Validation of a Custom Interface pressure Measurement System to Improve Fitting of Transtibial Prosthetic Check Sockets","volume":"23","author":"Armitage","year":"2023","journal-title":"Sensors"},{"issue":"2","key":"10.1016\/j.jbiomech.2026.113187_bib216","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1097\/PXR.0000000000000174","article-title":"Transtibial prosthetic socket fitting: Australian prosthetist perspectives on primary challenges, management strategies, and opportunities for workflow and technological innovation","volume":"47","author":"Amitage","year":"2023","journal-title":"Prosthet. Orthot. Int."},{"key":"10.1016\/j.jbiomech.2026.113187_b0015","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.medengphy.2021.09.008","article-title":"Human-device interface pressure measurement in prosthetic, orthotic and exoskeleton applications: a systematic review","volume":"97","author":"Armitage","year":"2021","journal-title":"Med. Eng. Phys."},{"key":"10.1016\/j.jbiomech.2026.113187_b0020","unstructured":"Australian Physiotherapists in Amputee Rehabilitation, 2018."},{"issue":"1","key":"10.1016\/j.jbiomech.2026.113187_b0025","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1186\/s12938-018-0470-z","article-title":"Technologies to monitor the health of loaded skin tissues","volume":"17","author":"Bader","year":"2018","journal-title":"Biomed. Eng. Online"},{"issue":"1","key":"10.1016\/j.jbiomech.2026.113187_b0030","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1186\/s12984-023-01270-0","article-title":"Adjustable prosthetic sockets: a systematic review of industrial and research design characteristics and their justifications","volume":"20","author":"Baldock","year":"2023","journal-title":"J. Neuroeng. Rehabil."},{"key":"10.1016\/j.jbiomech.2026.113187_b0035","series-title":"Lower Limb Prostheses: Measurement Instruments, Comparison of Component Effects by Subgroups, and Long-Term Outcomes","author":"Balk","year":"2018"},{"issue":"4","key":"10.1016\/j.jbiomech.2026.113187_b0040","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1002\/pmrj.12899","article-title":"The relationship between residual limb health, motion within the socket, and prosthetic suspension","volume":"15","author":"Baumann","year":"2023","journal-title":"PM R"},{"key":"10.1016\/j.jbiomech.2026.113187_b0045","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.medengphy.2020.01.011","article-title":"Establishing a measurement array to assess tissue tolerance during loading representative of prosthetic use","volume":"78","author":"Bramley","year":"2020","journal-title":"Med. Eng. Phys."},{"issue":"7311","key":"10.1016\/j.jbiomech.2026.113187_b0050","first-page":"487","article-title":"Systematic reviews in health care: Systematic reviews of evaluations of diagnostic and screening tests","volume":"323","author":"Deeks","year":"2001","journal-title":"BMJ"},{"issue":"4","key":"10.1016\/j.jbiomech.2026.113187_b0055","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1016\/j.apmr.2004.09.003","article-title":"Dermatologic conditions associated with use of a lower-extremity prosthesis","volume":"86","author":"Dudek","year":"2005","journal-title":"Arch. Phys. Med. Rehabil."},{"issue":"1","key":"10.1016\/j.jbiomech.2026.113187_b0060","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1682\/JRRD.2006.11.0147","article-title":"Review of secondary physical conditions associated with lower-limb amputation and long-term prosthesis use","volume":"45","author":"Gailey","year":"2008","journal-title":"J. Rehabil. Res. Dev."},{"issue":"3","key":"10.1016\/j.jbiomech.2026.113187_b0065","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1111\/iwj.13667","article-title":"Our contemporary understanding of the aetiology of pressure ulcers\/pressure injuries","volume":"19","author":"Gefen","year":"2022","journal-title":"Int. Wound J."},{"issue":"4","key":"10.1016\/j.jbiomech.2026.113187_b0070","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1080\/10400435.2022.2079763","article-title":"The association of the localized pain sensitivity in the residual limb and prosthesis use in male veterans with transtibial amputation","volume":"35","author":"Ghoseiri","year":"2023","journal-title":"Assist. Technol."},{"issue":"1","key":"10.1016\/j.jbiomech.2026.113187_b0075","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1177\/0309364614550264","article-title":"Issues affecting the level of prosthetics research evidence: Secondary analysis of a systematic review","volume":"40","author":"Hafner","year":"2014","journal-title":"Prosthet. Orthot. Int."},{"issue":"22","key":"10.1016\/j.jbiomech.2026.113187_b0080","doi-asserted-by":"crossref","first-page":"1278","DOI":"10.1080\/09638280310001603983","article-title":"Prosthetic socket fit comfort score","volume":"25","author":"Hanspal","year":"2003","journal-title":"Disability and Rehabiliation"},{"issue":"2","key":"10.1016\/j.jbiomech.2026.113187_b0085","first-page":"55","article-title":"End-bearing characteristics of patellar-tendon-bearing prosthesis\u2013a preliminary report","volume":"16","author":"Katz","year":"1979","journal-title":"Bull. Prosthet. Res."},{"issue":"15","key":"10.1016\/j.jbiomech.2026.113187_b0090","doi-asserted-by":"crossref","first-page":"5016","DOI":"10.3390\/s21155016","article-title":"A Scoping Review of pressure Measurements in Prosthetic Sockets of Transfemoral Amputees during Ambulation: Key Considerations for Sensor Design","volume":"21","author":"Ko","year":"2021","journal-title":"Sensors"},{"key":"10.1016\/j.jbiomech.2026.113187_b0095","doi-asserted-by":"crossref","DOI":"10.3389\/fresc.2023.1322202","article-title":"Distal weight bearing in transtibial prosthesis users wearing pin suspension","volume":"4","author":"Krout","year":"2023","journal-title":"Front. Rehabil. Sci."},{"issue":"3","key":"10.1016\/j.jbiomech.2026.113187_b0100","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1097\/PHM.0000000000001043","article-title":"An Investigation of pressure Profiles and Wearer Comfort during walking with a Transtibial Hydrocast Socket","volume":"98","author":"Laing","year":"2019","journal-title":"Am. J. Phys. Med. Rehabil."},{"issue":"8","key":"10.1016\/j.jbiomech.2026.113187_b0110","doi-asserted-by":"crossref","first-page":"923","DOI":"10.1016\/j.medengphy.2006.09.008","article-title":"Using computational simulation to aid in the prediction of socket fit: a preliminary study","volume":"29","author":"Lee","year":"2007","journal-title":"Med. Eng. Phys."},{"issue":"4","key":"10.1016\/j.jbiomech.2026.113187_b0115","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1016\/j.apmr.2004.08.005","article-title":"Regional differences in pain threshold and tolerance of the transtibial residual limb: including the effects of age and interface material","volume":"86","author":"Lee","year":"2005","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"10.1016\/j.jbiomech.2026.113187_b0120","unstructured":"Limbs 4 Life, 2025. A Practical Guide for Amputees-12."},{"issue":"2","key":"10.1016\/j.jbiomech.2026.113187_b0125","doi-asserted-by":"crossref","first-page":"173","DOI":"10.2340\/00015555-1040","article-title":"Skin problems of the stump in lower limb amputees: 1","volume":"91","author":"Meulenbelt","year":"2011","journal-title":"A Clinical Study. Acta Dermato Venereologica"},{"issue":"1","key":"10.1016\/j.jbiomech.2026.113187_b0130","doi-asserted-by":"crossref","DOI":"10.1080\/07853890.2024.2380798","article-title":"The AERO prosthetic liner: socket pressure distribution, comfort and material composition","volume":"56","author":"Miyata","year":"2024","journal-title":"Ann. Med."},{"issue":"1","key":"10.1016\/j.jbiomech.2026.113187_b0135","article-title":"Concepts of pressure in an Ischial Containment Socket: Measurement","volume":"17","author":"Neumann","year":"2005","journal-title":"JPO: Journal of Prosthetics and Orthotics"},{"key":"10.1016\/j.jbiomech.2026.113187_b0140","doi-asserted-by":"crossref","DOI":"10.3389\/fresc.2022.853414","article-title":"The Impact of Limited Prosthetic Socket Documentation: a Researcher Perspective","volume":"3","author":"Olsen","year":"2022","journal-title":"Front. Rehabil. Sci."},{"key":"10.1016\/j.jbiomech.2026.113187_b0145","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"issue":"9","key":"10.1016\/j.jbiomech.2026.113187_b0150","first-page":"1996","article-title":"Sockets for Limb Prostheses: a Review of existing Technologies and Open challenges","volume":"65","author":"Paterno","year":"2018","journal-title":"I.E.E.E. Trans. Biomed. Eng."},{"issue":"3","key":"10.1016\/j.jbiomech.2026.113187_b0155","doi-asserted-by":"crossref","first-page":"147","DOI":"10.3109\/03093648209166575","article-title":"Measurement of maximal end-weight-bearing in lower limb amputees","volume":"6","author":"Persson","year":"1982","journal-title":"Prosthet. Orthot. Int."},{"issue":"4","key":"10.1016\/j.jbiomech.2026.113187_b0160","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1016\/j.medengphy.2009.12.006","article-title":"Real-time subject-specific analyses of dynamic internal tissue loads in the residual limb of transtibial amputees","volume":"32","author":"Portnoy","year":"2010","journal-title":"Med. Eng. Phys."},{"key":"10.1016\/j.jbiomech.2026.113187_b0165","doi-asserted-by":"crossref","unstructured":"Safari MR., et al., Socket Interface Pressure and Amputee Reported Outcomes for Comfortable and Uncomfortable Conditions of Patellar Tendon Bearing Socket: A Pilot Study. Assist Technol. 2015. 27(1):24-31; quiz 2-3. doi:10.1080\/10400435.2014.949016.","DOI":"10.1080\/10400435.2014.949016"},{"issue":"3","key":"10.1016\/j.jbiomech.2026.113187_b0175","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1080\/03093640600810266","article-title":"Effects of fluid insert volume changes on socket pressures and shear stresses: case studies from two trans-tibial amputee subjects","volume":"30","author":"Sanders","year":"2006","journal-title":"Prosthet. Orthot. Int."},{"issue":"3","key":"10.1016\/j.jbiomech.2026.113187_b0180","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1109\/86.788464","article-title":"In vivo indentation of lower extremity limb soft tissues","volume":"7","author":"Silver-Thorn","year":"1999","journal-title":"IEEE Trans. Rehabil. Eng."},{"issue":"10","key":"10.1016\/j.jbiomech.2026.113187_b0185","first-page":"2740","article-title":"A Framework for measuring the Time-Varying Shape and Full-Field Deformation of Residual Limbs using 3-D Digital image Correlation","volume":"66","author":"Solav","year":"2019","journal-title":"I.E.E.E. Trans. Biomed. Eng."},{"issue":"1","key":"10.1016\/j.jbiomech.2026.113187_b0190","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1097\/PXR.0000000000000147","article-title":"Optimal design and 3D printing of prosthetic socket based on the interface pressure between the socket and residual limb","volume":"47","author":"Tang","year":"2023","journal-title":"Prosthet. Orthot. Int."},{"issue":"3","key":"10.1016\/j.jbiomech.2026.113187_b0195","doi-asserted-by":"crossref","DOI":"10.1016\/j.arrct.2020.100059","article-title":"Perceived effect of Socket Fit on Major lower Limb Prosthetic Rehabilitation: a Clinician and Amputee Perspective","volume":"2","author":"Turner","year":"2020","journal-title":"Archives of Rehabilitation Research and Clinical Translation"},{"issue":"6","key":"10.1016\/j.jbiomech.2026.113187_b0200","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1080\/02533839.2003.9670840","article-title":"A proposal for the pre\u2010evaluation protocol of below\u2010knee socket design - integration pain tolerance with finite element analysis","volume":"26","author":"Wu","year":"2003","journal-title":"J. Chin. Inst. Eng."},{"issue":"11","key":"10.1016\/j.jbiomech.2026.113187_b0205","doi-asserted-by":"crossref","first-page":"888","DOI":"10.3109\/09638288.2012.712197","article-title":"Effects of long-distance walking on socket-limb interface pressure, tactile sensitivity and subjective perceptions of trans-tibial amputees","volume":"35","author":"Yeung","year":"2013","journal-title":"Disabil. Rehabil."},{"issue":"1","key":"10.1016\/j.jbiomech.2026.113187_b0215","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1080\/03093640500468074","article-title":"Quantifying the regional load-bearing ability of trans-tibial stumps","volume":"30","author":"Zhang","year":"2006","journal-title":"Prosthet. Orthot. Int."}],"container-title":["Journal of Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021929026000412?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021929026000412?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T04:05:09Z","timestamp":1779336309000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0021929026000412"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4]]},"references-count":41,"alternative-id":["S0021929026000412"],"URL":"https:\/\/doi.org\/10.1016\/j.jbiomech.2026.113187","relation":{},"ISSN":["0021-9290"],"issn-type":[{"value":"0021-9290","type":"print"}],"subject":[],"published":{"date-parts":[[2026,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The use of residual lower limb \u2013prosthetic socket interface pressure measurements to inform clinical decisions: A systematic review","name":"articletitle","label":"Article Title"},{"value":"Journal of Biomechanics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jbiomech.2026.113187","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"113187"}}