{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T09:28:30Z","timestamp":1793525310342,"version":"4.5.0"},"reference-count":18,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Biomechanics"],"published-print":{"date-parts":[[2026,11]]},"DOI":"10.1016\/j.jbiomech.2026.113624","type":"journal-article","created":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T22:47:19Z","timestamp":1791672439000},"page":"113624","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Two-laboratory comparability of apparent elastic modulus measurements in bovine lumbar vertebral trabecular bone under a standardized compression protocol"],"prefix":"10.1016","volume":"208","author":[{"given":"Irina","family":"Parshina","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dmitrii","family":"Ivanov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1885-0404","authenticated-orcid":false,"given":"Ilia","family":"Vindokurov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5636-1644","authenticated-orcid":false,"given":"Leonid","family":"Bessonov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aleksandr","family":"Dol","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mikhail","family":"Tashkinov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jbiomech.2026.113624_b0005","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"327","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"10.1016\/j.jbiomech.2026.113624_b0010","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1016\/0021-9290(93)90014-6","article-title":"Mechanical and textural properties of pelvic trabecular bone","volume":"26","author":"Dalstra","year":"1993","journal-title":"J. Biomech."},{"key":"10.1016\/j.jbiomech.2026.113624_b0015","doi-asserted-by":"crossref","DOI":"10.1016\/j.jbiomech.2025.113021","article-title":"Community challenge towards consensus on characterization of biological tissue: C4Bio\u2019s first findings","volume":"194","author":"Famaey","year":"2026","journal-title":"J. Biomech."},{"key":"10.1016\/j.jbiomech.2026.113624_b0020","doi-asserted-by":"crossref","first-page":"10181","DOI":"10.1038\/s41598-018-28155-w","article-title":"Juvenile bovine bone is an appropriate surrogate for normal and reduced density human bone in biomechanical testing: a validation study","volume":"8","author":"Fletcher","year":"2018","journal-title":"Sci. Rep."},{"key":"10.1016\/j.jbiomech.2026.113624_b0025","doi-asserted-by":"crossref","first-page":"862","DOI":"10.3390\/bioengineering12080862","article-title":"Approach to standardized material characterization of the human lumbopelvic system: testing and evaluation","volume":"12","author":"Gebhardt","year":"2025","journal-title":"Bioengineering"},{"key":"10.1016\/j.jbiomech.2026.113624_b0030","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/j.clinbiomech.2007.08.024","article-title":"Mathematical relationships between bone density and mechanical properties: a literature review","volume":"23","author":"Helgason","year":"2008","journal-title":"Clin. Biomech."},{"key":"10.1016\/j.jbiomech.2026.113624_b0035","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1016\/0021-9290(93)90059-N","article-title":"Trabecular bone modulus and strength can depend on specimen geometry","volume":"26","author":"Keaveny","year":"1993","journal-title":"J. Biomech."},{"key":"10.1016\/j.jbiomech.2026.113624_b0045","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1146\/annurev.bioeng.3.1.307","article-title":"Biomechanics of trabecular bone","volume":"3","author":"Keaveny","year":"2001","journal-title":"Annu. Rev. Biomed. Eng."},{"key":"10.1016\/j.jbiomech.2026.113624_b0040","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1002\/jor.1100150115","article-title":"Systematic and random errors in compression testing of trabecular bone","volume":"15","author":"Keaveny","year":"1997","journal-title":"J. Orthop. Res."},{"key":"10.1016\/j.jbiomech.2026.113624_b0050","doi-asserted-by":"crossref","first-page":"897","DOI":"10.1016\/S0021-9290(03)00071-X","article-title":"Trabecular bone modulus\u2013density relationships depend on anatomic site","volume":"36","author":"Morgan","year":"2003","journal-title":"J. Biomech."},{"key":"10.1016\/j.jbiomech.2026.113624_b0055","doi-asserted-by":"crossref","first-page":"e1176","DOI":"10.1002\/jsp2.1176","article-title":"Density and mechanical properties of vertebral trabecular bone\u2013a review","volume":"4","author":"\u00d6hman-M\u00e4gi","year":"2021","journal-title":"JOR Spine"},{"key":"10.1016\/j.jbiomech.2026.113624_b0060","doi-asserted-by":"crossref","unstructured":"Parshina, I.F., Dol\u2019, A.V., Bessonov, L.V., Falkovich, A.S., Ivanov, D.V., 2024. On the question of the effect of the loading method on the cancellous bone effective elasticity modulus. Mechanics of Solids 59, 3870\u20133879. Doi: 10.1134\/S0025654424606645.","DOI":"10.1134\/S0025654424606645"},{"key":"10.1016\/j.jbiomech.2026.113624_b0065","first-page":"231","article-title":"On the issue of studying the structural and mechanical characteristics of bovine cancellous bone. Izvestiya of Saratov University","volume":"25","author":"Parshina","year":"2025","journal-title":"Mathematics. Mechanics. Informatics"},{"key":"10.1016\/j.jbiomech.2026.113624_b0070","doi-asserted-by":"crossref","unstructured":"Parshina, I.F., Dol\u2019, A.V., Ivanov, D.V., Chentsov, A.V., Lisovenko, D.S., Kossovich, L.Yu., 2025b. Standardization of Mechanical Experiments with Biomaterials. Mechanics of Solids 60, 5526\u20135534. Doi: 10.1134\/S0025654425604525.","DOI":"10.1134\/S0025654425604525"},{"key":"10.1016\/j.jbiomech.2026.113624_b0075","doi-asserted-by":"crossref","first-page":"1059","DOI":"10.1016\/0021-9290(91)90022-F","article-title":"Physical and mechanical properties of calf lumbosacral trabecular bone","volume":"24","author":"Swartz","year":"1991","journal-title":"J. Biomech."},{"key":"10.1016\/j.jbiomech.2026.113624_b0080","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1016\/8756-3282(93)90081-K","article-title":"Basic biomechanical measurements of bone: a tutorial","volume":"14","author":"Turner","year":"1993","journal-title":"Bone"},{"key":"10.1016\/j.jbiomech.2026.113624_b0085","doi-asserted-by":"crossref","first-page":"1325","DOI":"10.1016\/S0021-9290(00)00069-5","article-title":"Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur","volume":"33","author":"Wirtz","year":"2000","journal-title":"J. Biomech."},{"key":"10.1016\/j.jbiomech.2026.113624_b0090","doi-asserted-by":"crossref","first-page":"524","DOI":"10.1302\/2046-3758.78.BJR-2018-0025.R1","article-title":"Standardizing compression testing for measuring the stiffness of human bone","volume":"7","author":"Zhao","year":"2018","journal-title":"Bone & Joint Research"}],"container-title":["Journal of Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S002192902600480X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S002192902600480X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T09:02:47Z","timestamp":1793523767000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S002192902600480X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,11]]},"references-count":18,"alternative-id":["S002192902600480X"],"URL":"https:\/\/doi.org\/10.1016\/j.jbiomech.2026.113624","relation":{},"ISSN":["0021-9290"],"issn-type":[{"value":"0021-9290","type":"print"}],"subject":[],"published":{"date-parts":[[2026,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Two-laboratory comparability of apparent elastic modulus measurements in bovine lumbar vertebral trabecular bone under a standardized compression protocol","name":"articletitle","label":"Article Title"},{"value":"Journal of Biomechanics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jbiomech.2026.113624","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"113624"}}