{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,16]],"date-time":"2026-01-16T17:12:15Z","timestamp":1768583535350,"version":"3.49.0"},"reference-count":35,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/501100000854","name":"Human Frontier Science Program","doi-asserted-by":"publisher","award":["HFSP RGY0067"],"award-info":[{"award-number":["HFSP RGY0067"]}],"id":[{"id":"10.13039\/501100000854","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journalofcardiovascularct.com","clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Cardiovascular Computed Tomography"],"published-print":{"date-parts":[[2019,1]]},"DOI":"10.1016\/j.jcct.2018.09.007","type":"journal-article","created":{"date-parts":[[2018,10,2]],"date-time":"2018-10-02T11:25:13Z","timestamp":1538479513000},"page":"21-30","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":50,"title":["Pre-procedural fit-testing of TAVR valves using parametric modeling and 3D printing"],"prefix":"10.1016","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1844-481X","authenticated-orcid":false,"given":"Ahmed","family":"Hosny","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joshua D.","family":"Dilley","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4718-3839","authenticated-orcid":false,"given":"Tatiana","family":"Kelil","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Moses","family":"Mathur","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5026-6216","authenticated-orcid":false,"given":"Mason N.","family":"Dean","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James C.","family":"Weaver","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Beth","family":"Ripley","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"10034","key":"10.1016\/j.jcct.2018.09.007_bib1","doi-asserted-by":"crossref","first-page":"2218","DOI":"10.1016\/S0140-6736(16)30073-3","article-title":"Transcatheter aortic valve replacement versus surgical valve replacement in intermediate-risk patients: a propensity score analysis","volume":"387","author":"Thourani","year":"2016","journal-title":"Lancet"},{"issue":"23","key":"10.1016\/j.jcct.2018.09.007_bib2","doi-asserted-by":"crossref","first-page":"2187","DOI":"10.1056\/NEJMoa1103510","article-title":"Transcatheter versus surgical aortic-valve replacement in high-risk patients","volume":"364","author":"Smith","year":"2011","journal-title":"N Engl J Med"},{"issue":"8","key":"10.1016\/j.jcct.2018.09.007_bib3","doi-asserted-by":"crossref","first-page":"840","DOI":"10.1016\/j.hlc.2016.12.003","article-title":"Transcatheter versus surgical aortic valve replacement in patients with lower surgical risk scores: a systematic review and meta-analysis of early outcomes","volume":"26","author":"Arora","year":"2017","journal-title":"Heart Lung Circ"},{"issue":"9","key":"10.1016\/j.jcct.2018.09.007_bib4","doi-asserted-by":"crossref","first-page":"908","DOI":"10.1016\/j.jacc.2012.11.055","article-title":"Aortic annular sizing for transcatheter aortic valve replacement using cross-sectional 3-dimensional transesophageal echocardiography","volume":"61","author":"Jilaihawi","year":"2013","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jcct.2018.09.007_bib5","doi-asserted-by":"crossref","DOI":"10.1002\/ccd.26987","article-title":"Anatomical risk models for paravalvular leak and landing zone complications for balloon-expandable transcatheter aortic valve replacement","author":"Condado","year":"2017","journal-title":"Cathet Cardiovasc Interv"},{"issue":"11","key":"10.1016\/j.jcct.2018.09.007_bib6","doi-asserted-by":"crossref","first-page":"1965","DOI":"10.1016\/j.jbiomech.2012.05.008","article-title":"Patient-specific modeling of biomechanical interaction in transcatheter aortic valve deployment","volume":"45","author":"Wang","year":"2012","journal-title":"J Biomech"},{"issue":"12","key":"10.1016\/j.jcct.2018.09.007_bib7","doi-asserted-by":"crossref","first-page":"1347","DOI":"10.1080\/10255842.2012.746676","article-title":"Simulation of transcatheter aortic valve implantation: a patient-specific finite element approach","volume":"17","author":"Auricchio","year":"2014","journal-title":"Comput Methods Biomech Biomed Eng"},{"issue":"6","key":"10.1016\/j.jcct.2018.09.007_bib8","doi-asserted-by":"crossref","first-page":"904","DOI":"10.1161\/CIRCRESAHA.116.310546","article-title":"Impact of three-dimensional printing on the study and treatment of congenital heart disease","volume":"120","author":"Bramlet","year":"2017","journal-title":"Circ Res"},{"issue":"5","key":"10.1016\/j.jcct.2018.09.007_bib9","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1097\/RTI.0000000000000217","article-title":"Cardiothoracic applications of 3-dimensional printing","volume":"31","author":"Giannopoulos","year":"2016","journal-title":"J Thorac Imag"},{"issue":"7","key":"10.1016\/j.jcct.2018.09.007_bib10","doi-asserted-by":"crossref","first-page":"1989","DOI":"10.1148\/rg.2015140260","article-title":"Three-dimensional physical modeling: applications and experience at mayo clinic","volume":"35","author":"Matsumoto","year":"2015","journal-title":"Radiographics"},{"issue":"7","key":"10.1016\/j.jcct.2018.09.007_bib11","doi-asserted-by":"crossref","first-page":"1965","DOI":"10.1148\/rg.2015140320","article-title":"Medical 3D printing for the radiologist","volume":"35","author":"Mitsouras","year":"2015","journal-title":"Radiographics"},{"issue":"3","key":"10.1016\/j.jcct.2018.09.007_bib12","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1002\/jmri.25526","article-title":"3D printing from MRI Data: harnessing strengths and minimizing weaknesses","volume":"45","author":"Ripley","year":"2017","journal-title":"J Magn Reson Imag"},{"issue":"1","key":"10.1016\/j.jcct.2018.09.007_bib13","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.jtcvs.2016.08.007","article-title":"Scan, plan, print, practice, perform: development and use of a patient-specific 3-dimensional printed model in adult cardiac surgery","volume":"153","author":"Hermsen","year":"2017","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"2","key":"10.1016\/j.jcct.2018.09.007_bib14","doi-asserted-by":"crossref","first-page":"e31","DOI":"10.1016\/j.athoracsur.2011.09.031","article-title":"Three-dimensional printing of models for preoperative planning and simulation of transcatheter valve replacement","volume":"93","author":"Schmauss","year":"2012","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jcct.2018.09.007_bib15","first-page":"1","article-title":"3D printing and intraoperative neuronavigation tailoring for skull base reconstruction after extended endoscopic endonasal surgery: proof of concept","author":"Essayed","year":"2018","journal-title":"J Neurosurg. March"},{"issue":"7","key":"10.1016\/j.jcct.2018.09.007_bib16","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1016\/j.jcmg.2017.04.005","article-title":"Quantitative prediction of paravalvular leak in transcatheter aortic valve replacement based on tissue-mimicking 3D printing","volume":"10","author":"Qian","year":"2017","journal-title":"JACC Cardiovasc Imaging"},{"issue":"9","key":"10.1016\/j.jcct.2018.09.007_bib17","doi-asserted-by":"crossref","first-page":"1323","DOI":"10.1016\/j.mri.2012.05.001","article-title":"3D slicer as an image computing platform for the quantitative imaging network","volume":"30","author":"Fedorov","year":"2012","journal-title":"Magn Reson Imaging"},{"issue":"1","key":"10.1016\/j.jcct.2018.09.007_bib18","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.jcct.2015.12.004","article-title":"3D printing based on cardiac CT assists anatomic visualization prior to transcatheter aortic valve replacement","volume":"10","author":"Ripley","year":"2016","journal-title":"J Cardiovasc Comput Tomogr"},{"issue":"3","key":"10.1016\/j.jcct.2018.09.007_bib19","doi-asserted-by":"crossref","first-page":"593","DOI":"10.2214\/ajr.182.3.1820593","article-title":"Using MRI to assess aortic wall thickness in the multiethnic study of atherosclerosis: distribution by race, sex, and age","volume":"182","author":"Li","year":"2004","journal-title":"AJR Am J Roentgenol"},{"issue":"7","key":"10.1016\/j.jcct.2018.09.007_bib20","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1016\/0002-9149(88)90971-X","article-title":"Age-related changes in aortic and mitral valve thickness: implications for two-dimensional echocardiography based on an autopsy study of 200 normal human hearts","volume":"62","author":"Sahasakul","year":"1988","journal-title":"Am J Cardiol"},{"issue":"6244","key":"10.1016\/j.jcct.2018.09.007_bib21","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1126\/science.aab0129","article-title":"A 3D-printed, functionally graded soft robot powered by combustion","volume":"349","author":"Bartlett","year":"2015","journal-title":"Science"},{"issue":"9","key":"10.1016\/j.jcct.2018.09.007_bib22","doi-asserted-by":"crossref","first-page":"1989","DOI":"10.1007\/s10439-014-1051-3","article-title":"Simulation of self expanding transcatheter aortic valve in a realistic aortic root: implications of deployment geometry on leaflet deformation","volume":"42","author":"Gunning","year":"2014","journal-title":"Ann Biomed Eng"},{"issue":"6","key":"10.1016\/j.jcct.2018.09.007_bib23","doi-asserted-by":"crossref","first-page":"1037","DOI":"10.1161\/CIRCRESAHA.114.302292","article-title":"Evolution of transcatheter aortic valve replacement","volume":"114","author":"Bourantas","year":"2014","journal-title":"Circ Res"},{"issue":"6","key":"10.1016\/j.jcct.2018.09.007_bib24","doi-asserted-by":"crossref","first-page":"1214","DOI":"10.1016\/j.jacc.2006.01.049","article-title":"Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience","volume":"47","author":"Cribier","year":"2006","journal-title":"J Am Coll Cardiol"},{"issue":"8","key":"10.1016\/j.jcct.2018.09.007_bib25","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1007\/s00392-017-1097-y","article-title":"In-hospital mortality in propensity-score matched low-risk patients undergoing routine isolated surgical or transfemoral transcatheter aortic valve replacement in 2014","volume":"106","author":"Frerker","year":"2017","journal-title":"Research in Cardiology"},{"issue":"8","key":"10.1016\/j.jcct.2018.09.007_bib26","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1056\/NEJMra1313875","article-title":"Aortic-valve stenosis--from patients at risk to severe valve obstruction","volume":"371","author":"Otto","year":"2014","journal-title":"N Engl J Med"},{"issue":"2","key":"10.1016\/j.jcct.2018.09.007_bib27","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.jcct.2013.12.013","article-title":"The aortic valve calcium nodule score (AVCNS) independently predicts paravalvular regurgitation after transcatheter aortic valve replacement (TAVR)","volume":"8","author":"Azzalini","year":"2014","journal-title":"J Cardiovasc Comput Tomogr"},{"issue":"8","key":"10.1016\/j.jcct.2018.09.007_bib28","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1016\/j.jcin.2014.03.007","article-title":"Quantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement","volume":"7","author":"Khalique","year":"2014","journal-title":"JACC Cardiovasc Interv"},{"issue":"4","key":"10.1016\/j.jcct.2018.09.007_bib29","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1016\/j.jcct.2013.08.005","article-title":"Multidetector CT predictors of prosthesis\u2013patient mismatch in transcatheter aortic valve replacement","volume":"7","author":"Freeman","year":"2013","journal-title":"J Cardiovasc Comput Tomogr"},{"issue":"6","key":"10.1016\/j.jcct.2018.09.007_bib30","doi-asserted-by":"crossref","first-page":"732","DOI":"10.4244\/EIJV10I6A126","article-title":"Extent and distribution of calcification of both the aortic annulus and the left ventricular outflow tract predict aortic regurgitation after transcatheter aortic valve replacement","volume":"10","author":"Buellesfeld","year":"2014","journal-title":"EuroIntervention"},{"issue":"4","key":"10.1016\/j.jcct.2018.09.007_bib31","first-page":"190","article-title":"Relationship of aortic annular eccentricity and paravalvular regurgitation post transcatheter aortic valve implantation with CoreValve","volume":"25","author":"Wong","year":"2013","journal-title":"J Invasive Cardiol"},{"issue":"3","key":"10.1016\/j.jcct.2018.09.007_bib32","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1016\/j.jcin.2014.10.014","article-title":"Incidence and severity of paravalvular aortic regurgitation with multidetector computed tomography nominal area oversizing or undersizing after transcatheter heart valve replacement with the sapien 3","volume":"8","author":"Yang","year":"2015","journal-title":"JACC Cardiovasc Interv"},{"issue":"3","key":"10.1016\/j.jcct.2018.09.007_bib33","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1016\/j.jtcvs.2010.09.068","article-title":"Determination of the elastic modulus of ascending thoracic aortic aneurysm at different ranges of pressure using uniaxial tensile testing","volume":"142","author":"Khanafer","year":"2011","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"Part A","key":"10.1016\/j.jcct.2018.09.007_bib34","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.addma.2016.06.006","article-title":"Dual-material 3D printed metamaterials with tunable mechanical properties for patient-specific tissue-mimicking phantoms","volume":"12","author":"Wang","year":"2016","journal-title":"Additive Manufacturing"},{"issue":"3","key":"10.1016\/j.jcct.2018.09.007_bib35","doi-asserted-by":"crossref","DOI":"10.1088\/1758-5082\/4\/3\/035005","article-title":"Rapid 3D printing of anatomically accurate and mechanically heterogeneous aortic valve hydrogel scaffolds","volume":"4","author":"Hockaday","year":"2012","journal-title":"Biofabrication"}],"container-title":["Journal of Cardiovascular Computed Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1934592518301722?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1934592518301722?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,8,8]],"date-time":"2019-08-08T13:42:18Z","timestamp":1565271738000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1934592518301722"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,1]]},"references-count":35,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,1]]}},"alternative-id":["S1934592518301722"],"URL":"https:\/\/doi.org\/10.1016\/j.jcct.2018.09.007","relation":{},"ISSN":["1934-5925"],"issn-type":[{"value":"1934-5925","type":"print"}],"subject":[],"published":{"date-parts":[[2019,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Pre-procedural fit-testing of TAVR valves using parametric modeling and 3D printing","name":"articletitle","label":"Article Title"},{"value":"Journal of Cardiovascular Computed Tomography","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcct.2018.09.007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Published by Elsevier Inc. on behalf of Society of Cardiovascular Computed Tomography","name":"copyright","label":"Copyright"}]}}