{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T19:29:34Z","timestamp":1769196574557,"version":"3.49.0"},"reference-count":47,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2019,3,1]],"date-time":"2019-03-01T00:00:00Z","timestamp":1551398400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"name":"Canadian Radiological Foundation, Ottawa, Canada"},{"name":"Cardiology Research Fund"},{"name":"Vancouver General Hospital, Vancouver, Canada"},{"name":"Department of Radiology Research Fund"},{"name":"Vancouver General Hospital, Vancouver, Canada"}],"content-domain":{"domain":["journalofcardiovascularct.com","clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Cardiovascular Computed Tomography"],"published-print":{"date-parts":[[2019,3]]},"DOI":"10.1016\/j.jcct.2019.01.020","type":"journal-article","created":{"date-parts":[[2019,1,30]],"date-time":"2019-01-30T12:44:57Z","timestamp":1548852297000},"page":"86-91","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":11,"title":["Quantified dual energy computed tomography perfusion imaging using myocardial iodine concentration: Validation using CT derived myocardial blood flow and invasive fractional flow reserve in a porcine model"],"prefix":"10.1016","volume":"13","author":[{"given":"Rohan","family":"Poulter","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David A.","family":"Wood","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1447-2220","authenticated-orcid":false,"given":"Andrew","family":"Starovoytov","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7014-5681","authenticated-orcid":false,"given":"Stephanie","family":"Smith","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mehran","family":"Chitsaz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John","family":"Mayo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jcct.2019.01.020_bib1","doi-asserted-by":"crossref","first-page":"e44","DOI":"10.1016\/j.jacc.2012.07.013","volume":"60","author":"Fihn","year":"2012","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib2","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1016\/j.jacc.2015.09.011","volume":"67","author":"Rybicki","year":"2016","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib3","doi-asserted-by":"crossref","first-page":"1724","DOI":"10.1016\/j.jacc.2008.07.031","volume":"52","author":"Budoff","year":"2008","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib4","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1016\/j.jacc.2008.05.024","article-title":"Comprehensive assessment of coronary artery stenoses: computed tomography coronary angiography versus conventional coronary angiography and correlation with fractional flow reserve in patients with stable angina","volume":"52","author":"Meijboom","year":"2008","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib5","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1016\/j.jacc.2008.10.043","article-title":"Prognostic value of multislice computed tomography and gated single-photon emission computed tomography in patients with suspected coronary artery disease","volume":"53","author":"van Werkhoven","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib6","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1016\/j.ijcard.2009.04.024","article-title":"Correlation between coronary computed tomographic angiography and fractional flow reserve","volume":"144","author":"Kristensen","year":"2010","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib7","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1007\/s10554-016-0994-x","article-title":"Prediction of clinical outcome by myocardial CT perfusion in patients with low-risk unstable angina pectoris","volume":"33","author":"Linde","year":"2017","journal-title":"Int J Cardiovasc Imag"},{"key":"10.1016\/j.jcct.2019.01.020_bib8","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1097\/RLI.0b013e3181dfa2f2","article-title":"Adenosine-stress dynamic myocardial CT perfusion imaging: initial clinical experience","volume":"45","author":"Bastarrika","year":"2010","journal-title":"Invest Radiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib9","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/j.jcct.2010.01.015","article-title":"Adenosine-stress dynamic myocardial volume perfusion imaging with second generation dual-source computed tomography: concepts and first experiences","volume":"4","author":"Bastarrika","year":"2010","journal-title":"Journal of cardiovascular computed tomography"},{"key":"10.1016\/j.jcct.2019.01.020_bib10","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1097\/RLI.0b013e318124a884","article-title":"Quantification of myocardial perfusion using dynamic 64-detector computed tomography","volume":"42","author":"George","year":"2007","journal-title":"Invest Radiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib11","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.jacc.2006.04.014","article-title":"Multidetector computed tomography myocardial perfusion imaging during adenosine stress","volume":"48","author":"George","year":"2006","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib12","doi-asserted-by":"crossref","unstructured":"Mahnken AH, Klotz E, Pietsch H, et al. Quantitative whole heart stress perfusion CT imaging as noninvasive assessment of hemodynamics in coronary artery stenosis: preliminary animal experience. Invest Radiol;45:298-305.","DOI":"10.1097\/RLI.0b013e3181dfa3cf"},{"key":"10.1016\/j.jcct.2019.01.020_bib13","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1016\/j.jcmg.2010.05.009","article-title":"Stress and rest dynamic myocardial perfusion imaging by evaluation of complete time-attenuation curves with dual-source CT","volume":"3","author":"Ho","year":"2010","journal-title":"JACC Cardiovasc Imaging"},{"key":"10.1016\/j.jcct.2019.01.020_bib14","doi-asserted-by":"crossref","first-page":"W67","DOI":"10.2214\/AJR.14.14087","article-title":"Absolute versus relative myocardial blood flow by dynamic CT myocardial perfusion imaging in patients with anatomic coronary artery disease","volume":"205","author":"Wichmann","year":"2015","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.jcct.2019.01.020_bib15","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1007\/s00330-011-2260-x","article-title":"Non-invasive assessment of functionally relevant coronary artery stenoses with quantitative CT perfusion: preliminary clinical experiences","volume":"22","author":"So","year":"2012","journal-title":"Eur Radiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib16","doi-asserted-by":"crossref","first-page":"801","DOI":"10.1097\/RLI.0000000000000087","article-title":"Relative myocardial blood flow by dynamic computed tomographic perfusion imaging predicts hemodynamic significance of coronary stenosis better than absolute blood flow","volume":"49","author":"Kono","year":"2014","journal-title":"Invest Radiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib17","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1007\/s00330-013-3063-z","article-title":"Dose reduction in dynamic CT stress myocardial perfusion imaging: comparison of 80-kV\/370-mAs and 100-kV\/300-mAs protocols","volume":"24","author":"Fujita","year":"2014","journal-title":"Eur Radiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib18","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1007\/s12350-009-9156-z","article-title":"Direct comparison of rest and adenosine stress myocardial perfusion CT with rest and stress SPECT","volume":"17","author":"Okada","year":"2010","journal-title":"J Nucl Cardiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib19","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1148\/radiol.09091014","article-title":"Incremental value of adenosine-induced stress myocardial perfusion imaging with dual-source CT at cardiac CT angiography","volume":"254","author":"Rocha-Filho","year":"2010","journal-title":"Radiology"},{"key":"10.1016\/j.jcct.2019.01.020_bib20","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCIMAGING.116.005189","volume":"9","author":"Penagaluri","year":"2016","journal-title":"Circ Cardiovasc Imaging"},{"key":"10.1016\/j.jcct.2019.01.020_bib21","doi-asserted-by":"crossref","first-page":"1510","DOI":"10.1007\/s00330-006-0517-6","article-title":"Material differentiation by dual energy CT: initial experience","volume":"17","author":"Johnson","year":"2007","journal-title":"Eur Radiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib22","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1016\/j.jacc.2009.06.014","article-title":"Adenosine-induced stress myocardial perfusion imaging using dual-source cardiac computed tomography","volume":"54","author":"Blankstein","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib23","doi-asserted-by":"crossref","first-page":"1244","DOI":"10.1161\/CIRCULATIONAHA.107.745711","article-title":"Images in cardiovascular medicine. Myocardial ischemia diagnosed by dual-energy computed tomography: correlation with single-photon emission computed tomography","volume":"117","author":"Ruzsics","year":"2008","journal-title":"Circulation"},{"key":"10.1016\/j.jcct.2019.01.020_bib24","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1016\/j.amjcard.2009.03.051","article-title":"Comparison of dual-energy computed tomography of the heart with single photon emission computed tomography for assessment of coronary artery stenosis and of the myocardial blood supply","volume":"104","author":"Ruzsics","year":"2009","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib25","doi-asserted-by":"crossref","first-page":"2414","DOI":"10.1007\/s00330-008-1022-x","article-title":"Dual-energy CT of the heart for diagnosing coronary artery stenosis and myocardial ischemia-initial experience","volume":"18","author":"Ruzsics","year":"2008","journal-title":"Eur Radiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib26","doi-asserted-by":"crossref","first-page":"1487","DOI":"10.1016\/j.amjcard.2009.02.005","article-title":"Combined assessment of coronary anatomy and myocardial perfusion using multidetector computed tomography for the evaluation of coronary artery disease","volume":"103","author":"Kachenoura","year":"2009","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib27","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1016\/j.jcct.2011.11.002","article-title":"Quantitative myocardial CT perfusion: a pictorial review and the current state of technology development","volume":"5","author":"So","year":"2011","journal-title":"Journal of cardiovascular computed tomography"},{"key":"10.1016\/j.jcct.2019.01.020_bib28","doi-asserted-by":"crossref","first-page":"443","DOI":"10.2214\/ajr.139.3.443","article-title":"The unreliability of CT numbers as absolute values","volume":"139","author":"Levi","year":"1982","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.jcct.2019.01.020_bib29","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1016\/j.jcmg.2011.02.008","article-title":"Impact of unexpected factors on quantitative myocardial perfusion and coronary flow reserve in young, asymptomatic volunteers","volume":"4","author":"Sdringola","year":"2011","journal-title":"JACC Cardiovasc Imaging"},{"key":"10.1016\/j.jcct.2019.01.020_bib30","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1053\/j.sult.2010.05.004","article-title":"Dual-energy computed tomography for integrative imaging of coronary artery disease: principles and clinical applications","volume":"31","author":"Kang","year":"2010","journal-title":"Semin Ultrasound CT MR"},{"issue":"2","key":"10.1016\/j.jcct.2019.01.020_bib31","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1097\/RTI.0000000000000284","article-title":"Quantitative analysis of iodine image of dual-energy computed tomography at rest: comparison with 99mtc-tetrofosmin stress-rest single-photon emission computed tomography myocardial perfusion imaging as the reference standard","volume":"33","author":"Nakahara","year":"2018","journal-title":"J Thorac Imag"},{"key":"10.1016\/j.jcct.2019.01.020_bib32","doi-asserted-by":"crossref","first-page":"1703","DOI":"10.1056\/NEJM199606273342604","article-title":"Measurement of fractional flow reserve to assess the functional severity of coronary-artery stenoses","volume":"334","author":"Pijls","year":"1996","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jcct.2019.01.020_bib33","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1056\/NEJMoa0807611","article-title":"Fractional flow reserve versus angiography for guiding percutaneous coronary intervention","volume":"360","author":"Tonino","year":"2009","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jcct.2019.01.020_bib34","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1056\/NEJMoa1205361","article-title":"Fractional flow reserve-guided PCI versus medical therapy in stable coronary disease","volume":"367","author":"De Bruyne","year":"2012","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jcct.2019.01.020_bib35","doi-asserted-by":"crossref","first-page":"837","DOI":"10.2307\/2531595","article-title":"Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach","volume":"44","author":"DeLong","year":"1988","journal-title":"Biometrics"},{"key":"10.1016\/j.jcct.2019.01.020_bib36","doi-asserted-by":"crossref","DOI":"10.1016\/j.hlc.2018.06.1050","article-title":"Development of a porcine model of coronary stenosis using fully percutaneous techniques suitable for performing cardiac computed tomography, CT-perfusion imaging and fractional flow reserve","author":"Poulter","year":"2018","journal-title":"Heart Lung Circ"},{"key":"10.1016\/j.jcct.2019.01.020_bib37","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1161\/CIRCIMAGING.108.813766","article-title":"Adenosine stress 64- and 256-row detector computed tomography angiography and perfusion imaging: a pilot study evaluating the transmural extent of perfusion abnormalities to predict atherosclerosis causing myocardial ischemia","volume":"2","author":"George","year":"2009","journal-title":"Circ Cardiovasc Imaging"},{"key":"10.1016\/j.jcct.2019.01.020_bib38","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1016\/j.jcct.2011.10.005","article-title":"CT stress myocardial perfusion imaging using multidetector CT--A review","volume":"5","author":"Ko","year":"2011","journal-title":"Journal of cardiovascular computed tomography"},{"key":"10.1016\/j.jcct.2019.01.020_bib39","doi-asserted-by":"crossref","first-page":"2411","DOI":"10.1016\/j.ejrad.2014.12.032","article-title":"The dream of a one-stop-shop: meta-analysis on myocardial perfusion CT","volume":"84","author":"Pelgrim","year":"2015","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib40","doi-asserted-by":"crossref","first-page":"487","DOI":"10.2214\/AJR.14.13546","article-title":"CT myocardial perfusion imaging","volume":"204","author":"Varga-Szemes","year":"2015","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.jcct.2019.01.020_bib41","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1016\/0735-1097(89)90105-8","article-title":"Noninvasive quantitation of myocardial blood flow in human subjects with oxygen-15-labeled water and positron emission tomography","volume":"14","author":"Bergmann","year":"1989","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib42","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1161\/01.CIR.80.5.1328","article-title":"13N ammonia myocardial imaging at rest and with exercise in normal volunteers. Quantification of absolute myocardial perfusion with dynamic positron emission tomography","volume":"80","author":"Krivokapich","year":"1989","journal-title":"Circulation"},{"key":"10.1016\/j.jcct.2019.01.020_bib43","doi-asserted-by":"crossref","first-page":"1989","DOI":"10.1016\/j.jacc.2011.06.066","volume":"58","author":"Koo","year":"2011","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib44","doi-asserted-by":"crossref","first-page":"1237","DOI":"10.1001\/2012.jama.11274","article-title":"Diagnostic accuracy of fractional flow reserve from anatomic CT angiography","volume":"308","author":"Min","year":"2012","journal-title":"J Am Med Assoc"},{"key":"10.1016\/j.jcct.2019.01.020_bib45","doi-asserted-by":"crossref","first-page":"1145","DOI":"10.1016\/j.jacc.2013.11.043","article-title":"Diagnostic performance of noninvasive fractional flow reserve derived from coronary computed tomography angiography in suspected coronary artery disease: the NXT trial (Analysis of Coronary Blood Flow Using CT Angiography: next Steps)","volume":"63","author":"Norgaard","year":"2014","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib46","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1001\/jamacardio.2017.1314","article-title":"Diagnostic accuracy of computed tomography-derived fractional flow reserve : a systematic review","volume":"2","author":"Cook","year":"2017","journal-title":"JAMA Cardiol"},{"key":"10.1016\/j.jcct.2019.01.020_bib47","doi-asserted-by":"crossref","first-page":"989","DOI":"10.2214\/AJR.13.11441","article-title":"CT angiography (CTA) and diagnostic performance of noninvasive fractional flow reserve: results from the Determination of Fractional Flow Reserve by Anatomic CTA (DeFACTO) study","volume":"202","author":"Leipsic","year":"2014","journal-title":"AJR Am J Roentgenol"}],"container-title":["Journal of Cardiovascular Computed Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1934592518302612?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1934592518302612?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,11,15]],"date-time":"2019-11-15T13:37:49Z","timestamp":1573825069000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1934592518302612"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3]]},"references-count":47,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2019,3]]}},"alternative-id":["S1934592518302612"],"URL":"https:\/\/doi.org\/10.1016\/j.jcct.2019.01.020","relation":{},"ISSN":["1934-5925"],"issn-type":[{"value":"1934-5925","type":"print"}],"subject":[],"published":{"date-parts":[[2019,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Quantified dual energy computed tomography perfusion imaging using myocardial iodine concentration: Validation using CT derived myocardial blood flow and invasive fractional flow reserve in a porcine model","name":"articletitle","label":"Article Title"},{"value":"Journal of Cardiovascular Computed Tomography","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcct.2019.01.020","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}