{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T15:06:40Z","timestamp":1789571200855,"version":"build-2803163510"},"reference-count":27,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2024,5,1]],"date-time":"2024-05-01T00:00:00Z","timestamp":1714521600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,5,1]],"date-time":"2024-05-01T00:00:00Z","timestamp":1714521600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,4,27]],"date-time":"2025-04-27T00:00:00Z","timestamp":1745712000000},"content-version":"am","delay-in-days":361,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["journalofcardiovascularct.com","clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Cardiovascular Computed Tomography"],"published-print":{"date-parts":[[2024,5]]},"DOI":"10.1016\/j.jcct.2024.02.008","type":"journal-article","created":{"date-parts":[[2024,2,29]],"date-time":"2024-02-29T13:24:55Z","timestamp":1709213095000},"page":"281-290","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":14,"title":["Usefulness of second-generation motion correction algorithm in improving delineation and reducing motion artifact of coronary computed tomography angiography"],"prefix":"10.1016","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-0593-8499","authenticated-orcid":false,"given":"Shintaro","family":"Yamaguchi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6383-207X","authenticated-orcid":false,"given":"Yasutaka","family":"Ichikawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6883-8059","authenticated-orcid":false,"given":"Masafumi","family":"Takafuji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hajime","family":"Sakuma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4402-6846","authenticated-orcid":false,"given":"Kakuya","family":"Kitagawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jcct.2024.02.008_bib1","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1093\/eurheartj\/ehab892","article-title":"European Society of Cardiology: cardiovascular disease statistics 2021","volume":"43","author":"Timmis","year":"2022","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jcct.2024.02.008_bib2","doi-asserted-by":"crossref","first-page":"e93","DOI":"10.1161\/CIR.0000000000001123","article-title":"Heart disease and stroke statistics-2023 update: a report from the American heart association","volume":"147","author":"Tsao","year":"2023","journal-title":"Circulation"},{"key":"10.1016\/j.jcct.2024.02.008_bib3","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1001\/jamacardio.2017.4973","article-title":"Use of high-risk coronary atherosclerotic plaque detection for risk stratification of patients with stable chest pain: a secondary analysis of the PROMISE randomized clinical trial","volume":"3","author":"Ferencik","year":"2018","journal-title":"JAMA Cardiol"},{"key":"10.1016\/j.jcct.2024.02.008_bib4","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/j.jacc.2015.05.069","article-title":"Plaque characterization by coronary computed tomography angiography and the likelihood of acute coronary events in mid-term follow-up","volume":"66","author":"Motoyama","year":"2015","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcct.2024.02.008_bib5","doi-asserted-by":"crossref","first-page":"1289","DOI":"10.1093\/eurheartj\/ehaa575","article-title":"2020 ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation","volume":"42","author":"Collet","year":"2021","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jcct.2024.02.008_bib6","doi-asserted-by":"crossref","first-page":"2218","DOI":"10.1016\/j.jacc.2021.07.052","article-title":"2021 AHA\/ACC\/ASE\/CHEST\/SAEM\/SCCT\/SCMR guideline for the evaluation and diagnosis of chest pain: executive summary: a report of the American college of cardiology\/American heart association joint committee on clinical practice guidelines","volume":"78","author":"Gulati","year":"2021","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcct.2024.02.008_bib7","doi-asserted-by":"crossref","first-page":"982","DOI":"10.1136\/heartjnl-2015-308341","article-title":"National Institute for Health and Care Excellence updates the stable chest pain guideline with radical changes to the diagnostic paradigm","volume":"103","author":"Timmis","year":"2017","journal-title":"Heart"},{"key":"10.1016\/j.jcct.2024.02.008_bib8","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1080\/17434440.2016.1184968","article-title":"Recent developments in the use of computed tomography scanners in coronary artery imaging","volume":"13","author":"Aghayev","year":"2016","journal-title":"Expet Rev Med Dev"},{"key":"10.1016\/j.jcct.2024.02.008_bib9","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1097\/RCT.0000000000000641","article-title":"Impact of SSF on diagnostic performance of coronary computed tomography angiography within 1 heart beat in patients with high heart rate using a 256-row detector computed tomography","volume":"42","author":"Liang","year":"2018","journal-title":"J\u00a0Comput Assist Tomogr"},{"key":"10.1016\/j.jcct.2024.02.008_bib10","doi-asserted-by":"crossref","first-page":"1603","DOI":"10.1007\/s10554-014-0499-4","article-title":"Impact of a vendor-specific motion-correction algorithm on image quality, interpretability, and diagnostic performance of daily routine coronary CT angiography: influence of heart rate on the effect of motion-correction","volume":"30","author":"Lee","year":"2014","journal-title":"Int J Cardiovasc Imag"},{"key":"10.1016\/j.jcct.2024.02.008_bib11","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1007\/s11604-014-0382-1","article-title":"Influence of the motion correction algorithm on the quality and interpretability of images of single-source 64-detector coronary CT angiography among patients grouped by heart rate","volume":"33","author":"Machida","year":"2015","journal-title":"Jpn J Radiol"},{"key":"10.1016\/j.jcct.2024.02.008_bib12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.clinimag.2016.11.002","article-title":"Impact of a motion correction algorithm on image quality in patients undergoing CT angiography: a randomized controlled trial","volume":"42","author":"Sheta","year":"2017","journal-title":"Clin Imag"},{"key":"10.1016\/j.jcct.2024.02.008_bib13","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1097\/RCT.0000000000000683","article-title":"A\u00a0preliminary study of computed tomography coronary angiography within a single cardiac cycle in patients with atrial fibrillation using 256-row detector computed tomography","volume":"42","author":"Wen","year":"2018","journal-title":"J\u00a0Comput Assist Tomogr"},{"key":"10.1016\/j.jcct.2024.02.008_bib14","doi-asserted-by":"crossref","DOI":"10.1016\/j.crad.2017.03.004","article-title":"Diagnostic performance of 256-row detector coronary CT angiography in patients with high heart rates within a single cardiac cycle: a preliminary study","volume":"72","author":"Liang","year":"2017","journal-title":"Clin Radiol"},{"key":"10.1016\/j.jcct.2024.02.008_bib15","doi-asserted-by":"crossref","first-page":"4215","DOI":"10.1007\/s00330-018-5929-6","article-title":"Second-generation motion correction algorithm improves diagnostic accuracy of single-beat coronary CT angiography in patients with increased heart rate","volume":"29","author":"Liang","year":"2019","journal-title":"Eur Radiol"},{"key":"10.1016\/j.jcct.2024.02.008_bib16","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1118\/1.4938265","article-title":"Automated selection of the optimal cardiac phase for single-beat coronary CT angiography reconstruction","volume":"43","author":"Stassi","year":"2016","journal-title":"Med Phys"},{"key":"10.1016\/j.jcct.2024.02.008_bib17","article-title":"Clinical evaluation of new automatic coronary-specific best cardiac phase selection algorithm for single-beat coronary CT angiography","volume":"12","author":"Wang","year":"2017","journal-title":"PLoS One"},{"key":"10.1016\/j.jcct.2024.02.008_bib18","doi-asserted-by":"crossref","first-page":"4245","DOI":"10.1118\/1.4725712","article-title":"Nonrigid registration-based coronary artery motion correction for cardiac computed tomography","volume":"39","author":"Bhagalia","year":"2012","journal-title":"Med Phys"},{"key":"10.1016\/j.jcct.2024.02.008_bib19","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1016\/j.jcct.2016.08.001","article-title":"The effect of a whole heart motion-correction algorithm on CT image quality and measurement reproducibility in Pre-TAVR aortic annulus evaluation","volume":"10","author":"Soon","year":"2016","journal-title":"J\u00a0Cardiovasc Comput Tomogr"},{"key":"10.1016\/j.jcct.2024.02.008_bib20","doi-asserted-by":"crossref","first-page":"2620","DOI":"10.1007\/s00330-021-08367-x","article-title":"Radiation dose reduction with deep-learning image reconstruction for coronary computed tomography angiography","volume":"32","author":"Benz","year":"2022","journal-title":"Eur Radiol"},{"key":"10.1016\/j.jcct.2024.02.008_bib21","doi-asserted-by":"crossref","first-page":"598","DOI":"10.1007\/s11604-021-01089-6","article-title":"Deep learning image reconstruction for improvement of image quality of abdominal computed tomography: comparison with hybrid iterative reconstruction","volume":"39","author":"Ichikawa","year":"2021","journal-title":"Jpn J Radiol"},{"key":"10.1016\/j.jcct.2024.02.008_bib22","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1161\/01.CIR.51.4.5","article-title":"A\u00a0reporting system on patients evaluated for coronary artery disease. Report of the ad hoc committee for grading of coronary artery disease, council on cardiovascular surgery, American heart association","volume":"51","author":"Austen","year":"1975","journal-title":"Circulation"},{"key":"10.1016\/j.jcct.2024.02.008_bib23","series-title":"The Measurement, Reporting, and Management of Radiation Dose in CT: Report of AAPM Task Group 23 of the Diagnostic Imaging Council CT Committee. AAPM Report No. 96. College Park (MD): American Association of Physicists in Medicine","year":"2008"},{"key":"10.1016\/j.jcct.2024.02.008_bib24","doi-asserted-by":"crossref","first-page":"2024","DOI":"10.1016\/j.ejrad.2014.08.002","article-title":"Effect of a novel motion correction algorithm (SSF) on the image quality of coronary CTA with intermediate heart rates: segment-based and vessel-based analyses","volume":"83","author":"Li","year":"2014","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.jcct.2024.02.008_bib25","doi-asserted-by":"crossref","first-page":"765","DOI":"10.2214\/AJR.12.9037","article-title":"Image quality and radiation dose stratified by patient heart rate for coronary 64- and 320-MDCT angiography","volume":"200","author":"Fujimoto","year":"2013","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.jcct.2024.02.008_bib26","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1148\/radiol.2021210245","article-title":"Influence of heart rate on image quality and radiation dose exposure in coronary CT angiography","volume":"300","author":"Stocker","year":"2021","journal-title":"Radiology"},{"key":"10.1016\/j.jcct.2024.02.008_bib27","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1016\/j.jcct.2020.11.001","article-title":"SCCT 2021 expert consensus document on coronary computed tomographic angiography: a report of the society of cardiovascular computed tomography","volume":"15","author":"Narula","year":"2021","journal-title":"J\u00a0Cardiovasc Comput Tomogr"}],"container-title":["Journal of Cardiovascular Computed Tomography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1934592524000595?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1934592524000595?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,4,28]],"date-time":"2024-04-28T14:01:53Z","timestamp":1714312913000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1934592524000595"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5]]},"references-count":27,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024,5]]}},"alternative-id":["S1934592524000595"],"URL":"https:\/\/doi.org\/10.1016\/j.jcct.2024.02.008","relation":{},"ISSN":["1934-5925"],"issn-type":[{"value":"1934-5925","type":"print"}],"subject":[],"published":{"date-parts":[[2024,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Usefulness of second-generation motion correction algorithm in improving delineation and reducing motion artifact of coronary computed tomography angiography","name":"articletitle","label":"Article Title"},{"value":"Journal of Cardiovascular Computed Tomography","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcct.2024.02.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}