{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T22:24:52Z","timestamp":1789597492753,"version":"build-2803163510"},"reference-count":24,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jcehepatology.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Clinical and Experimental Hepatology"],"published-print":{"date-parts":[[2026,5]]},"DOI":"10.1016\/j.jceh.2026.103496","type":"journal-article","created":{"date-parts":[[2026,2,18]],"date-time":"2026-02-18T00:29:31Z","timestamp":1771374571000},"page":"103496","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"title":["EUS-guided Liver Biopsy and Portosystemic Pressure Gradient Assessment (Using Modified Non-proprietary Setup) in Patients With Suspected cACLD or Cirrhosis"],"prefix":"10.1016","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8567-1676","authenticated-orcid":false,"given":"Arka","family":"De","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arpit","family":"Shastri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5520-8306","authenticated-orcid":false,"given":"Suvradeep","family":"Mitra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sweta","family":"Rose","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naveen K","family":"Balakrishnan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9858-7935","authenticated-orcid":false,"given":"Malvika","family":"Shastri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Babulal","family":"Meena","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9446-4209","authenticated-orcid":false,"given":"Naveen","family":"Bhagat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4328-0914","authenticated-orcid":false,"given":"Nipun","family":"Verma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Madhumita","family":"Premkumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sunil","family":"Taneja","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ajay","family":"Duseja","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jceh.2026.103496_bib1","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1016\/j.jhep.2021.12.022","article-title":"Baveno VII Faculty. Baveno VII - Renewing consensus in portal hypertension","volume":"76","author":"de Franchis","year":"2022","journal-title":"J Hepatol"},{"key":"10.1016\/j.jceh.2026.103496_bib2","doi-asserted-by":"crossref","first-page":"171","DOI":"10.4103\/EUS-D-21-00268","article-title":"EUS-guided versus percutaneous liver biopsy: A comprehensive review and meta-analysis of outcomes","volume":"12","author":"Chandan","year":"2023","journal-title":"Endosc Ultrasound"},{"key":"10.1016\/j.jceh.2026.103496_bib3","doi-asserted-by":"crossref","first-page":"1238","DOI":"10.3390\/diagnostics14121238","article-title":"Diagnostic Yield of Endoscopic Ultrasound-Guided Liver Biopsy in Comparison to Percutaneous Liver Biopsy: A Meta-Analysis of Randomized Controlled Trials and Trial Sequential Analysis","volume":"14","author":"Bhandari","year":"2024","journal-title":"Diagnostics (Basel)"},{"key":"10.1016\/j.jceh.2026.103496_bib4","article-title":"Comparison of Diagnostic Accuracy and Diagnostic Adequacy Between Endoscopic Ultrasound-Guided and Percutaneous Liver Biopsies: A Meta-Analysis of Randomized Controlled Trials and Observational Studies","volume":"16","author":"Ahmad","year":"2024","journal-title":"Cureus"},{"key":"10.1016\/j.jceh.2026.103496_bib5","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1080\/17474124.2022.2020645","article-title":"Diagnostic yield of endoscopic ultrasound-guided liver biopsy in comparison to percutaneous liver biopsy: a systematic review and meta-analysis","volume":"16","author":"Facciorusso","year":"2022","journal-title":"Expert Rev Gastroenterol Hepatol"},{"key":"10.1016\/j.jceh.2026.103496_bib6","article-title":"EUS-Guided Liver Biopsy and Portal Pressure Measurement Compared With a Transjugular Approach: A Randomized Controlled Trial","volume":"S1542-3565(25)00850-X","author":"Benmassaoud","year":"2025","journal-title":"Clin Gastroenterol Hepatol"},{"key":"10.1016\/j.jceh.2026.103496_bib7","doi-asserted-by":"crossref","first-page":"2903","DOI":"10.1111\/tri.14105","article-title":"Endoscopic ultrasound guided portal-systemic pressure gradient measurement to determine candidacy for kidney transplant alone versus combined liver kidney transplant in patients with advanced fibrosis or cirrhosis","volume":"34","author":"Rubin","year":"2021","journal-title":"Transpl Int"},{"key":"10.1016\/j.jceh.2026.103496_bib8","doi-asserted-by":"crossref","first-page":"2167","DOI":"10.1016\/j.cgh.2024.12.022","article-title":"Endoscopic Ultrasound-Guided Portosystemic Pressure Gradient Correlates With Clinical Parameters and Liver Histology","volume":"23","author":"Kolb","year":"2025","journal-title":"Clin Gastroenterol Hepatol"},{"key":"10.1016\/j.jceh.2026.103496_bib9","doi-asserted-by":"crossref","first-page":"1373","DOI":"10.1111\/jgh.15875","article-title":"Endoscopic ultrasound-guided portal pressure gradient with liver biopsy: 6 years of endo-hepatology in practice","volume":"37","author":"Choi","year":"2022","journal-title":"J Gastroenterol Hepatol"},{"key":"10.1016\/j.jceh.2026.103496_bib10","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1016\/j.gie.2021.11.037","article-title":"Simultaneous EUS-guided portosystemic pressure measurement and liver biopsy sampling correlate with clinically meaningful outcomes","volume":"95","author":"Hajifathalian","year":"2022","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.jceh.2026.103496_bib11","first-page":"356","article-title":"Endoscopic ultrasound-guided portal pressure gradient measurement: a systematic review and meta-analysis","volume":"37","author":"Dhindsa","year":"2024","journal-title":"Ann Gastroenterol"},{"key":"10.1016\/j.jceh.2026.103496_bib12","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1016\/j.gie.2020.06.065","article-title":"EUS-guided portal pressure gradient measurement in patients with acute or subacute portal hypertension","volume":"93","author":"Zhang","year":"2021","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.jceh.2026.103496_bib13","doi-asserted-by":"crossref","DOI":"10.1002\/ccr3.6658","article-title":"Technique innovation of endoscopic ultrasound portal pressure gradient measurement using standard manometer set for portal hypertension assessment","volume":"10","author":"Lesmana","year":"2022","journal-title":"Clin Case Rep"},{"key":"10.1016\/j.jceh.2026.103496_bib14","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1016\/j.gie.2021.10.016","article-title":"Top tips regarding EUS-guided liver biopsy","volume":"95","author":"Diehl","year":"2022","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.jceh.2026.103496_bib15","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.gie.2024.07.030","article-title":"Top tips for EUS-guided portal pressure gradient measurement (with video)","volume":"101","author":"Adler","year":"2025","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.jceh.2026.103496_bib16","doi-asserted-by":"crossref","first-page":"1017","DOI":"10.1002\/hep.22742","article-title":"American Association for the Study of Liver Diseases. Liver biopsy","volume":"49","author":"Rockey","year":"2009","journal-title":"Hepatology"},{"key":"10.1016\/j.jceh.2026.103496_bib17","doi-asserted-by":"crossref","first-page":"1382","DOI":"10.1136\/gutjnl-2020-321299","article-title":"Guidelines on the use of liver biopsy in clinical practice from the British Society of Gastroenterology, the Royal College of Radiologists and the Royal College of Pathology","volume":"69","author":"Neuberger","year":"2020","journal-title":"Gut"},{"key":"10.1016\/j.jceh.2026.103496_bib18","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.jhep.2015.04.006","article-title":"Non-invasive tests for evaluation of liver disease severity and prognosis","volume":"63","year":"2015","journal-title":"J Hepatol"},{"key":"10.1016\/j.jceh.2026.103496_bib19","doi-asserted-by":"crossref","first-page":"1087","DOI":"10.1136\/jclinpath-2013-201440","article-title":"How often do our liver core biopsies reach current definitions of adequacy?","volume":"66","author":"Fryer","year":"2013","journal-title":"J Clin Pathol"},{"key":"10.1016\/j.jceh.2026.103496_bib20","doi-asserted-by":"crossref","first-page":"E938","DOI":"10.1055\/a-1165-1767","article-title":"EUS-guided fine-needle core liver biopsy with a modified one-pass, one-actuation wet suction technique comparing two types of EUS core needles","volume":"8","author":"Nieto","year":"2020","journal-title":"Endosc Int Open"},{"key":"10.1016\/j.jceh.2026.103496_bib21","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1016\/j.gie.2021.03.023","article-title":"Single-pass 1-needle actuation versus single-pass 3-needle actuation technique for EUS-guided liver biopsy sampling: a randomized prospective trial (with video)","volume":"94","author":"Ching-Companioni","year":"2021","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.jceh.2026.103496_bib22","doi-asserted-by":"crossref","first-page":"3586","DOI":"10.3748\/wjg.v28.i28.3586","article-title":"Update on endoscopic ultrasound-guided liver biopsy","volume":"28","author":"Rangwani","year":"2022","journal-title":"World J Gastroenterol"},{"key":"10.1016\/j.jceh.2026.103496_bib23","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1055\/a-2369-0759","article-title":"Correlation of endoscopic ultrasound-guided portal pressure gradient measurements with hepatic venous pressure gradient: a prospective study","volume":"57","author":"Martinez-Moreno","year":"2025","journal-title":"Endoscopy"},{"key":"10.1016\/j.jceh.2026.103496_bib24","doi-asserted-by":"crossref","first-page":"101466","DOI":"10.1016\/j.jhepr.2025.101466","article-title":"Endoscopic ultrasound-guided portosystemic pressure gradient measurement vs. transjugular balloon occlusion measurement in patients with cirrhosis (ENCOUNTER): A bicentric EU study","volume":"7","author":"Vanderschueren","year":"2025","journal-title":"JHEP Rep"}],"container-title":["Journal of Clinical and Experimental Hepatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0973688326000289?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0973688326000289?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,6,20]],"date-time":"2026-06-20T14:34:17Z","timestamp":1781966057000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0973688326000289"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5]]},"references-count":24,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,5]]}},"alternative-id":["S0973688326000289"],"URL":"https:\/\/doi.org\/10.1016\/j.jceh.2026.103496","relation":{},"ISSN":["0973-6883"],"issn-type":[{"value":"0973-6883","type":"print"}],"subject":[],"published":{"date-parts":[[2026,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"EUS-guided Liver Biopsy and Portosystemic Pressure Gradient Assessment (Using Modified Non-proprietary Setup) in Patients With Suspected cACLD or Cirrhosis","name":"articletitle","label":"Article Title"},{"value":"Journal of Clinical and Experimental Hepatology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jceh.2026.103496","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Indian National Association for Study of the Liver. Published by Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"103496"}}