{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,24]],"date-time":"2026-07-24T23:25:10Z","timestamp":1784935510249,"version":"3.55.0"},"reference-count":91,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"vor","delay-in-days":731,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100015539","name":"Australian Government","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100015539","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000925","name":"National Health and Medical Research Council","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000925","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","cysticfibrosisjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Cystic Fibrosis"],"published-print":{"date-parts":[[2023,1]]},"DOI":"10.1016\/j.jcf.2022.07.013","type":"journal-article","created":{"date-parts":[[2022,7,26]],"date-time":"2022-07-26T23:44:31Z","timestamp":1658879071000},"page":"39-49","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":20,"title":["Continuous glucose monitoring versus self-monitoring of blood glucose in the management of cystic fibrosis related diabetes: A systematic review and meta-analysis"],"prefix":"10.1016","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5456-2699","authenticated-orcid":false,"given":"Shanal","family":"Kumar","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Georgia","family":"Soldatos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1323-4917","authenticated-orcid":false,"given":"Sanjeeva","family":"Ranasinha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Helena","family":"Teede","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1801-450X","authenticated-orcid":false,"given":"Michael","family":"Pallin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"4","key":"10.1016\/j.jcf.2022.07.013_bib0001","doi-asserted-by":"crossref","first-page":"233","DOI":"10.7326\/M13-0636","article-title":"Longevity of patients with cystic fibrosis in 2000 to 2010 and beyond: survival analysis of the cystic fibrosis foundation patient registry","volume":"161","author":"MacKenzie","year":"2014","journal-title":"Ann Intern Med"},{"issue":"3","key":"10.1016\/j.jcf.2022.07.013_bib0002","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1016\/j.jpeds.2005.06.043","article-title":"Cystic fibrosis birth rates in Canada: a decreasing trend since the onset of genetic testing","volume":"147","author":"Dupuis","year":"2005","journal-title":"J Pediatr"},{"issue":"3","key":"10.1016\/j.jcf.2022.07.013_bib0003","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1016\/S0022-3476(88)80315-9","article-title":"Diabetes mellitus associated with cystic fibrosis","volume":"112","author":"Finkelstein","year":"1988","journal-title":"J Pediatr"},{"issue":"2","key":"10.1016\/j.jcf.2022.07.013_bib0004","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1164\/rccm.201403-0576OC","article-title":"Diabetes-related mortality in adults with cystic fibrosis. Role of genotype and sex","volume":"191","author":"Lewis","year":"2015","journal-title":"Am J Respir Crit Care Med"},{"issue":"8","key":"10.1016\/j.jcf.2022.07.013_bib0005","first-page":"345","article-title":"Diabetes mellitus in patients with cystic fibrosis: the impact of diabetes mellitus on pulmonary function and clinical outcome","volume":"6","author":"Rosenecker","year":"2001","journal-title":"Eur J Med Res"},{"issue":"9","key":"10.1016\/j.jcf.2022.07.013_bib0006","doi-asserted-by":"crossref","first-page":"1626","DOI":"10.2337\/dc09-0586","article-title":"Cystic Fibrosis\u2013related diabetes: current trends in prevalence, incidence, and mortality","volume":"32","author":"Moran","year":"2009","journal-title":"Diabetes Care"},{"issue":"5","key":"10.1016\/j.jcf.2022.07.013_bib0007","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1002\/ppul.1142","article-title":"Presence of cystic fibrosis-related diabetes mellitus is tightly linked to poor lung function in patients with cystic fibrosis: data from the European epidemiologic registry of cystic fibrosis","volume":"32","author":"Koch","year":"2001","journal-title":"Pediatr Pulmonol"},{"issue":"6","key":"10.1016\/j.jcf.2022.07.013_bib0008","doi-asserted-by":"crossref","first-page":"947","DOI":"10.1007\/s10096-016-2621-0","article-title":"Staphylococcus aureus and pseudomonas aeruginosa co-infection is associated with cystic fibrosis-related diabetes and poor clinical outcomes","volume":"35","author":"Limoli","year":"2016","journal-title":"Eur J Clin Microbiol Infect Dis"},{"issue":"2","key":"10.1016\/j.jcf.2022.07.013_bib0009","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1378\/chest.11-0917","article-title":"Incidence and risk factors for pulmonary exacerbation treatment failures in patients with cystic fibrosis chronically infected with pseudomonas aeruginosa","volume":"141","author":"Parkins","year":"2012","journal-title":"Chest"},{"issue":"12","key":"10.1016\/j.jcf.2022.07.013_bib0010","doi-asserted-by":"crossref","first-page":"2677","DOI":"10.2337\/dc10-1279","article-title":"Epidemiology, pathophysiology, and prognostic implications of cystic fibrosis\u2013related diabetes","volume":"33","author":"Moran","year":"2010","journal-title":"Diabetes Care"},{"issue":"8","key":"10.1016\/j.jcf.2022.07.013_bib0011","doi-asserted-by":"crossref","first-page":"e98240","DOI":"10.1172\/jci.insight.98240","article-title":"Cystic fibrosis-related diabetes is caused by islet loss and inflammation","volume":"3","author":"Hart","year":"2018","journal-title":"JCI Insight"},{"issue":"4","key":"10.1016\/j.jcf.2022.07.013_bib0012","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1056\/NEJM198607243150402","article-title":"Impaired insulin action in puberty","volume":"315","author":"Amiel","year":"1986","journal-title":"N Engl J Med"},{"issue":"2","key":"10.1016\/j.jcf.2022.07.013_bib0013","doi-asserted-by":"crossref","DOI":"10.1097\/01.AOG.0000172421.04007.74","article-title":"The metabolic effects of pregnancy in cystic fibrosis","volume":"106","author":"Hardin","year":"2005","journal-title":"Obstetr Gynecol"},{"issue":"5","key":"10.1016\/j.jcf.2022.07.013_bib0014","doi-asserted-by":"crossref","first-page":"1082","DOI":"10.2337\/diabetes.48.5.1082","article-title":"Hepatic insulin resistance and defects in substrate utilization in cystic fibrosis","volume":"48","author":"Hardin","year":"1999","journal-title":"Diabetes"},{"issue":"5","key":"10.1016\/j.jcf.2022.07.013_bib0015","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1016\/S0022-3476(05)80032-0","article-title":"Pancreatic endocrine function in cystic fibrosis","volume":"118","author":"Moran","year":"1991","journal-title":"J Pediatr"},{"issue":"2","key":"10.1016\/j.jcf.2022.07.013_bib0016","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.jcf.2006.03.009","article-title":"Airway glucose concentrations and effect on growth of respiratory pathogens in cystic fibrosis","volume":"6","author":"Brennan","year":"2007","journal-title":"J Cyst Fibros"},{"issue":"2","key":"10.1016\/j.jcf.2022.07.013_bib0017","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1378\/chest.06-2888","article-title":"Incidence and risk factors for multiple antibiotic-resistant Pseudomonas aeruginosa in cystic fibrosis","volume":"132","author":"Merlo","year":"2007","journal-title":"Chest"},{"key":"10.1016\/j.jcf.2022.07.013_bib0018","doi-asserted-by":"crossref","DOI":"10.1016\/j.jcf.2021.03.004","article-title":"Continuous glucose monitoring indices predict poor FEV(1) recovery following cystic fibrosis pulmonary exacerbations","author":"Pallin","year":"2021","journal-title":"J Cyst Fibros"},{"issue":"5","key":"10.1016\/j.jcf.2022.07.013_bib0019","doi-asserted-by":"crossref","first-page":"1038","DOI":"10.1177\/193229681200600507","article-title":"Cystic fibrosis-related diabetes in adults: inpatient management of 121 patients during 410 admissions","volume":"6","author":"Rasouli","year":"2012","journal-title":"J Diabetes Sci Technol"},{"issue":"4","key":"10.1016\/j.jcf.2022.07.013_bib0020","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1016\/j.clnu.2014.08.016","article-title":"Carbohydrate intake and insulin requirement in children, adolescents and young adults with cystic fibrosis-related diabetes: a multicenter comparison to type 1 diabetes","volume":"34","author":"Scheuing","year":"2015","journal-title":"Clin Nutr"},{"issue":"1","key":"10.1016\/j.jcf.2022.07.013_bib0021","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1111\/pedi.12158","article-title":"Why is insulin pump treatment rarely used in adolescents and young adults with cystic fibrosis-related diabetes?","volume":"16","author":"Scheuing","year":"2015","journal-title":"Pediatr Diabetes"},{"key":"10.1016\/j.jcf.2022.07.013_bib0022","doi-asserted-by":"crossref","first-page":"S25","DOI":"10.1016\/j.jcf.2019.08.025","article-title":"Continuous glucose monitoring in cystic fibrosis - a practical guide","volume":"18","author":"Chan","year":"2019","journal-title":"J Cyst Fibros"},{"issue":"4","key":"10.1016\/j.jcf.2022.07.013_bib0023","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1001\/jama.2016.19975","article-title":"Effect of continuous glucose monitoring on glycemic control in adults with type 1 diabetes using insulin injections: the DIAMOND randomized clinical trial","volume":"317","author":"Beck","year":"2017","journal-title":"JAMA"},{"issue":"4","key":"10.1016\/j.jcf.2022.07.013_bib0024","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1001\/jama.2016.19976","article-title":"Continuous glucose monitoring vs conventional therapy for glycemic control in adults With Type 1 diabetes treated with multiple daily insulin injections: the GOLD randomized clinical trial","volume":"317","author":"Lind","year":"2017","journal-title":"JAMA"},{"issue":"6","key":"10.1016\/j.jcf.2022.07.013_bib0025","doi-asserted-by":"crossref","first-page":"736","DOI":"10.2337\/dc17-0133","article-title":"The impact of continuous glucose monitoring on markers of quality of life in adults with type 1 diabetes: further findings from the DIAMOND randomized clinical trial","volume":"40","author":"Polonsky","year":"2017","journal-title":"Diabetes Care"},{"issue":"12","key":"10.1016\/j.jcf.2022.07.013_bib0026","doi-asserted-by":"crossref","first-page":"2697","DOI":"10.2337\/dc10-1768","article-title":"Clinical care guidelines for cystic fibrosis\u2013related diabetes","volume":"33","author":"Moran","year":"2010","journal-title":"Diabetes Care"},{"issue":"1","key":"10.1016\/j.jcf.2022.07.013_bib0027","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.jcf.2005.09.001","article-title":"Relationship between glycosylated haemoglobin and mean plasma glucose concentration in cystic fibrosis","volume":"5","author":"Brennan","year":"2006","journal-title":"J Cyst Fibros"},{"issue":"7","key":"10.1016\/j.jcf.2022.07.013_bib0028","doi-asserted-by":"crossref","first-page":"1406","DOI":"10.2337\/dc17-2419","article-title":"Hemoglobin accurately predicts continuous glucose monitoring\u2013derived average glucose in youth and young adults with cystic fibrosis","volume":"41","author":"Chan","year":"2018","journal-title":"Diabetes Care"},{"issue":"7","key":"10.1016\/j.jcf.2022.07.013_bib0029","first-page":"90","article-title":"Accelerated red blood cell turnover can invalidate the use of hemoglobin A1c as a diagnostic test for cystic fibrosis related diabetes","volume":"45","author":"Hardin","year":"1999","journal-title":"Pediatr Res"},{"issue":"4","key":"10.1016\/j.jcf.2022.07.013_bib0030","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1046\/j.1442-200X.1999.t01-1-01083.x","article-title":"Effects of iron deficiency anemia on hemoglobin A1c in type 1 diabetes mellitus","volume":"41","author":"Tarim","year":"1999","journal-title":"Pediatr Int"},{"issue":"3","key":"10.1016\/j.jcf.2022.07.013_bib0031","doi-asserted-by":"crossref","DOI":"10.3390\/nu14030673","article-title":"Iron deficiency in cystic fibrosis: a cross-sectional single-centre study in a referral adult centre","volume":"14","author":"Lobbes","year":"2022","journal-title":"Nutrients"},{"issue":"5","key":"10.1016\/j.jcf.2022.07.013_bib0032","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1177\/0884533608323426","article-title":"Anemia in cystic fibrosis: incidence, mechanisms, and association with pulmonary function and vitamin deficiency","volume":"23","author":"von Drygalski","year":"2008","journal-title":"Nutr Clin Pract"},{"issue":"6","key":"10.1016\/j.jcf.2022.07.013_bib0033","doi-asserted-by":"crossref","first-page":"e166","DOI":"10.1038\/nutd.2015.16","article-title":"Implications of iron deficiency\/anemia on the classification of diabetes using HbA1c","volume":"5","author":"Attard","year":"2015","journal-title":"Nutr Diabetes"},{"issue":"7","key":"10.1016\/j.jcf.2022.07.013_bib0034","doi-asserted-by":"crossref","first-page":"1577","DOI":"10.2337\/dc10-2289","article-title":"Hyperglycemia and death in cystic fibrosis-related diabetes","volume":"34","author":"Adler","year":"2011","journal-title":"Diabetes Care"},{"issue":"7","key":"10.1016\/j.jcf.2022.07.013_bib0035","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pmed.1000097","article-title":"Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement","volume":"6","author":"Moher","year":"2009","journal-title":"PLoS Med"},{"key":"10.1016\/j.jcf.2022.07.013_bib0036","unstructured":"Kumar S.P.M., Soldatos G., Teede H.. PROSPERO 2021 CRD42021245817 Available from: https:\/\/www.crd.york.ac.uk\/prospero\/display_record.php?ID=CRD42021245817. 2021."},{"issue":"12","key":"10.1016\/j.jcf.2022.07.013_bib0037","doi-asserted-by":"crossref","first-page":"1631","DOI":"10.2337\/dc17-1600","article-title":"International consensus on use of continuous glucose monitoring","volume":"40","author":"Danne","year":"2017","journal-title":"Diabetes Care"},{"key":"10.1016\/j.jcf.2022.07.013_bib0038","doi-asserted-by":"crossref","first-page":"i4919","DOI":"10.1136\/bmj.i4919","article-title":"ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions","volume":"355","author":"Sterne","year":"2016","journal-title":"BMJ"},{"issue":"7109","key":"10.1016\/j.jcf.2022.07.013_bib0039","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1136\/bmj.315.7109.629","article-title":"Bias in meta-analysis detected by a simple, graphical test","volume":"315","author":"Egger","year":"1997","journal-title":"BMJ"},{"issue":"1","key":"10.1016\/j.jcf.2022.07.013_bib0040","doi-asserted-by":"crossref","first-page":"S142","DOI":"10.1016\/S1569-1993(15)30502-6","article-title":"Use of an insulin pump combined with the FreeStyle Libre interstitial glucose monitor in a needle-phobic adolescent with cystic fibrosis-related diabetes","volume":"14","author":"Campbell","year":"2015","journal-title":"J Cyst Fibros"},{"issue":"3","key":"10.1016\/j.jcf.2022.07.013_bib0041","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1016\/j.jcf.2006.08.004","article-title":"Cystic fibrosis related diabetes in an extremely young patient","volume":"6","author":"Casas","year":"2007","journal-title":"J Cyst Fibros"},{"key":"10.1016\/j.jcf.2022.07.013_bib0042","article-title":"Sustained glycemic control with ivacaftor in cystic fibrosis-related diabetes","volume":"7","author":"Christian","year":"2019","journal-title":"J Investig Med High Impact Case Rep"},{"issue":"7","key":"10.1016\/j.jcf.2022.07.013_bib0043","doi-asserted-by":"crossref","DOI":"10.1210\/clinem\/dgaa167","article-title":"Semaglutide in cystic fibrosis-related diabetes","volume":"105","author":"Gnanapragasam","year":"2020","journal-title":"J Clin Endocrinol Metab"},{"issue":"1","key":"10.1016\/j.jcf.2022.07.013_bib0044","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1080\/09674845.2012.11978245","article-title":"Rapid progression to diabetes in a four-year-old girl with cystic fibrosis","volume":"69","author":"Pirgon","year":"2012","journal-title":"Br J Biomed Sci"},{"issue":"1","key":"10.1016\/j.jcf.2022.07.013_bib0045","first-page":"98","article-title":"Managing cystic fibrosis related diabetes patients on enteral feed: are we well equipped?","volume":"28","author":"Rayanagoudar","year":"2011","journal-title":"Diabet Med"},{"issue":"1","key":"10.1016\/j.jcf.2022.07.013_bib0046","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.jcf.2005.09.002","article-title":"Use of continuous subcutaneous insulin infusion in cystic fibrosis patients with cystic fibrosis-related diabetes awaiting transplantation","volume":"5","author":"Reali","year":"2006","journal-title":"J Cyst Fibros"},{"key":"10.1016\/j.jcf.2022.07.013_bib0047","first-page":"68","article-title":"Effectiveness of CHO-counting on glycometabolic control and comparison between the methods of I\/CHO ratio calculation in subjects with cystic fibrosis-related diabetes (CFRD)","author":"Grancini","year":"2019","journal-title":"Diabetes"},{"issue":"2","key":"10.1016\/j.jcf.2022.07.013_bib0048","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/j.jcf.2007.07.004","article-title":"Glargine versus NPH insulin in cystic fibrosis related diabetes","volume":"7","author":"Grover","year":"2008","journal-title":"J Cyst Fibros"},{"issue":"1","key":"10.1016\/j.jcf.2022.07.013_bib0049","article-title":"Continuous glucose monitoring as a useful decision-making tool for adults with cystic fibrosis","volume":"16","author":"Balzer","year":"2014","journal-title":"Internet J Pulm Med"},{"issue":"1","key":"10.1016\/j.jcf.2022.07.013_bib0050","first-page":"S105","article-title":"Utility of an ultra-long acting insulin to treat cystic fibrosis related diabetes","volume":"14","author":"Dyce","year":"2015","journal-title":"J Cyst Fibros"},{"key":"10.1016\/j.jcf.2022.07.013_bib0051","first-page":"417","article-title":"A multi-disciplinary approach to glycaemic control in CFRD utilising continuous glucose monitoring (CGM): 571","volume":"48","author":"Dyce","year":"2013","journal-title":"Pediatr Pulmonol"},{"key":"10.1016\/j.jcf.2022.07.013_bib0052","doi-asserted-by":"crossref","first-page":"S126","DOI":"10.1016\/S1569-1993(20)30582-8","article-title":"The impact of FreeStyle Libre flash glucose monitoring system on HbA1c in patients with cystic fibrosis-related diabetes","volume":"19","author":"Hagan","year":"2020","journal-title":"J Cyst Fibros"},{"issue":"35","key":"10.1016\/j.jcf.2022.07.013_bib0053","first-page":"372","article-title":"The effects of a 10 week home-based supervised exercise training program in individuals with cystic fibrosis related diabetes","volume":"47","author":"Muniandy","year":"2012","journal-title":"Pediatr Pulmonol"},{"issue":"2","key":"10.1016\/j.jcf.2022.07.013_bib0054","doi-asserted-by":"crossref","first-page":"86","DOI":"10.4103\/JOD.JOD_13_19","article-title":"Use of continuous glucose monitoring in diagnosis and management of cystic fibrosis-related diabetes in children","volume":"11","author":"Ng","year":"2020","journal-title":"J Diabetol"},{"key":"10.1016\/j.jcf.2022.07.013_bib0055","first-page":"19","article-title":"WS15.4 early experience of flash glucose monitoring using the freestyle Libre system in adults with cystic fibrosis-related diabetes (CFRD) attending a large regional UK Centre","author":"Shimmin","year":"2020","journal-title":"J Cyst Fibros"},{"issue":"1","key":"10.1016\/j.jcf.2022.07.013_bib0056","doi-asserted-by":"crossref","first-page":"S148","DOI":"10.1016\/S1569-1993(17)30674-4","article-title":"The impact of continuous glucose monitoring on HbA1c in patients with cystic fibrosis related diabetes","volume":"16","author":"Stackhouse","year":"2017","journal-title":"J Cyst Fibros"},{"issue":"1","key":"10.1016\/j.jcf.2022.07.013_bib0057","first-page":"18","article-title":"Feasibility and efficacy of combined pancreatic islet-lung transplantation in cystic fibrosisrelated diabetes: a pilot study","volume":"33","author":"Bonnette","year":"2020","journal-title":"Transpl Int"},{"issue":"1","key":"10.1016\/j.jcf.2022.07.013_bib0058","doi-asserted-by":"crossref","first-page":"S103","DOI":"10.1016\/S1569-1993(15)30354-4","article-title":"Evolution of glycemia, insulinemia and glycosylated hemoglobin in a CF pediatric population","volume":"14","author":"Denis","year":"2015","journal-title":"J Cyst Fibros"},{"issue":"3","key":"10.1016\/j.jcf.2022.07.013_bib0059","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1016\/j.jcf.2008.12.001","article-title":"Use of the insulin pump in treat cystic fibrosis related diabetes","volume":"8","author":"Hardin","year":"2009","journal-title":"J Cyst Fibros"},{"issue":"2","key":"10.1016\/j.jcf.2022.07.013_bib0060","first-page":"84","article-title":"The effect of CFTR modulators on the progression of cystic fibrosis-related diabetes","volume":"55","author":"Hasan","year":"2020","journal-title":"Pediatr Pulmonol"},{"issue":"34","key":"10.1016\/j.jcf.2022.07.013_bib0061","first-page":"405","article-title":"Effect of repaglinide therapy in adult patients with cystic fibrosis related diabetes","volume":"46","author":"Hubert","year":"2011","journal-title":"Pediatr Pulmonol"},{"issue":"1","key":"10.1016\/j.jcf.2022.07.013_bib0062","first-page":"10","article-title":"Improvement in diabetes control following the introduction of joint cystic fibrosis related diabetes clinics in adult patients","volume":"34","author":"Kettley","year":"2017","journal-title":"Diabet Med"},{"issue":"1","key":"10.1016\/j.jcf.2022.07.013_bib0063","first-page":"24","article-title":"Impact of joint clinics on glycaemic control in individuals with cystic-fibrosis-related diabetes","volume":"30","author":"Sullivan","year":"2013","journal-title":"Diabet Med"},{"issue":"35","key":"10.1016\/j.jcf.2022.07.013_bib0064","first-page":"420","article-title":"Continuous glucose monitoring (CGM) for cystic fibrosis related diabetes (CFRD): sweet success or bitter disappointment?","volume":"47","author":"Dyce","year":"2012","journal-title":"Pediatr Pulmonol"},{"issue":"10","key":"10.1016\/j.jcf.2022.07.013_bib0065","doi-asserted-by":"crossref","first-page":"333","DOI":"10.20452\/pamw.1087","article-title":"Efficacy and safety comparison of continuous glucose monitoring and self-monitoring of blood glucose in type 1 diabetes: systematic review and meta-analysis","volume":"121","author":"Wojciechowski","year":"2011","journal-title":"Pol Arch Med Wewn"},{"issue":"3","key":"10.1016\/j.jcf.2022.07.013_bib0066","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1111\/cen.13290","article-title":"Real-time continuous glucose monitoring in type 1 diabetes: a systematic review and individual patient data meta-analysis","volume":"86","author":"Benkhadra","year":"2017","journal-title":"Clin Endocrinol"},{"issue":"4","key":"10.1016\/j.jcf.2022.07.013_bib0067","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1530\/EJE-11-0642","article-title":"Beneficial effect of real-time continuous glucose monitoring system on glycemic control in type 1 diabetic patients: systematic review and meta-analysis of randomized trials","volume":"166","author":"Szypowska","year":"2012","journal-title":"Eur J Endocrinol"},{"issue":"1","key":"10.1016\/j.jcf.2022.07.013_bib0068","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1186\/1758-5996-5-39","article-title":"Systematic review and meta-analysis of the effectiveness of continuous glucose monitoring (CGM) on glucose control in diabetes","volume":"5","author":"Poolsup","year":"2013","journal-title":"Diabetol Metab Syndr"},{"issue":"5","key":"10.1016\/j.jcf.2022.07.013_bib0069","doi-asserted-by":"crossref","first-page":"1146","DOI":"10.2337\/dc19-1459","article-title":"Effects of continuous glucose monitoring on metrics of glycemic control in diabetes: a systematic review with meta-analysis of randomized controlled trials","volume":"43","author":"Maiorino","year":"2020","journal-title":"Diabetes Care"},{"issue":"4","key":"10.1016\/j.jcf.2022.07.013_bib0070","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1111\/j.1464-5491.2010.03177.x","article-title":"Real-time continuous glucose monitoring system for treatment of diabetes: a systematic review","volume":"28","author":"Hoeks","year":"2011","journal-title":"Diabet Med"},{"issue":"5","key":"10.1016\/j.jcf.2022.07.013_bib0071","doi-asserted-by":"crossref","first-page":"1094","DOI":"10.1177\/193229681200600513","article-title":"Comparative analysis of the efficacy of continuous glucose monitoring and self-monitoring of blood glucose in type 1 diabetes mellitus","volume":"6","author":"Floyd","year":"2012","journal-title":"J Diabetes Sci Technol"},{"issue":"5","key":"10.1016\/j.jcf.2022.07.013_bib0072","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1089\/dia.2019.0345","article-title":"Systematic review of randomized controlled trials evaluating glycemic efficacy and patient satisfaction of intermittent-scanned continuous glucose monitoring in patients with diabetes","volume":"22","author":"Cowart","year":"2019","journal-title":"Diabetes Technol Ther"},{"issue":"1","key":"10.1016\/j.jcf.2022.07.013_bib0073","doi-asserted-by":"crossref","first-page":"e16166","DOI":"10.1371\/journal.pone.0016166","article-title":"Glucose depletion in the airway surface liquid is essential for sterility of the airways","volume":"6","author":"Pezzulo","year":"2011","journal-title":"PLoS One"},{"issue":"4","key":"10.1016\/j.jcf.2022.07.013_bib0074","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1016\/j.jcf.2013.11.005","article-title":"Early assessment of glucose abnormalities during continuous glucose monitoring associated with lung function impairment in cystic fibrosis patients","volume":"13","author":"Leclercq","year":"2014","journal-title":"J Cyst Fibros"},{"issue":"6","key":"10.1016\/j.jcf.2022.07.013_bib0075","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1016\/j.jcf.2018.03.008","article-title":"Continuous glucose monitoring abnormalities in cystic fibrosis youth correlate with pulmonary function decline","volume":"17","author":"Chan","year":"2018","journal-title":"J Cyst Fibros"},{"issue":"2","key":"10.1016\/j.jcf.2022.07.013_bib0076","doi-asserted-by":"crossref","first-page":"221","DOI":"10.2337\/dc09-1492","article-title":"Early glucose abnormalities in cystic fibrosis are preceded by poor weight gain","volume":"33","author":"Hameed","year":"2010","journal-title":"Diabetes Care"},{"issue":"8","key":"10.1016\/j.jcf.2022.07.013_bib0077","doi-asserted-by":"crossref","first-page":"1593","DOI":"10.2337\/dci19-0028","article-title":"Clinical Targets for continuous glucose monitoring data interpretation: recommendations from the international consensus on time in range","volume":"42","author":"Battelino","year":"2019","journal-title":"Diabetes Care"},{"issue":"3","key":"10.1016\/j.jcf.2022.07.013_bib0078","doi-asserted-by":"crossref","first-page":"400","DOI":"10.2337\/dc18-1444","article-title":"Validation of time in range as an outcome measure for diabetes clinical trials","volume":"42","author":"Beck","year":"2019","journal-title":"Diabetes Care"},{"issue":"5","key":"10.1016\/j.jcf.2022.07.013_bib0079","doi-asserted-by":"crossref","first-page":"1056","DOI":"10.2337\/dc06-1576","article-title":"Microvascular complications in cystic fibrosis\u2013related diabetes","volume":"30","author":"Schwarzenberg","year":"2007","journal-title":"Diabetes Care"},{"issue":"3","key":"10.1016\/j.jcf.2022.07.013_bib0080","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1016\/j.jcf.2017.01.018","article-title":"Association between glucose intolerance and bacterial colonisation in an adult population with cystic fibrosis, emergence of Stenotrophomonas maltophilia","volume":"16","author":"Lehoux Dubois","year":"2017","journal-title":"J Cyst Fibros"},{"key":"10.1016\/j.jcf.2022.07.013_bib0081","doi-asserted-by":"crossref","first-page":"37955","DOI":"10.1038\/srep37955","article-title":"Hyperglycaemia and Pseudomonas aeruginosa acidify cystic fibrosis airway surface liquid by elevating epithelial monocarboxylate transporter 2 dependent lactate-H(+) secretion","volume":"6","author":"Garnett","year":"2016","journal-title":"Sci Rep"},{"issue":"5","key":"10.1016\/j.jcf.2022.07.013_bib0082","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1016\/j.jcf.2015.12.011","article-title":"Advanced glycation end products are elevated in cystic fibrosis-related diabetes and correlate with worse lung function","volume":"15","author":"Hunt","year":"2016","journal-title":"J Cyst Fibros"},{"issue":"6","key":"10.1016\/j.jcf.2022.07.013_bib0083","doi-asserted-by":"crossref","first-page":"798","DOI":"10.1016\/j.jcf.2018.05.005","article-title":"Continuous glucose monitoring guided insulin therapy is associated with improved clinical outcomes in cystic fibrosis-related diabetes","volume":"17","author":"Frost","year":"2018","journal-title":"J Cyst Fibros"},{"issue":"5","key":"10.1016\/j.jcf.2022.07.013_bib0084","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1016\/j.diabet.2010.08.001","article-title":"Continuous glucose monitoring reduces both hypoglycaemia and HbA1c in hypoglycaemia-prone type 1 diabetic patients treated with a portable pump","volume":"36","author":"Radermecker","year":"2010","journal-title":"Diabetes Metab"},{"key":"10.1016\/j.jcf.2022.07.013_bib0085","doi-asserted-by":"crossref","unstructured":"Haliloglu B., Gokdemir Y., Atay Z., Abali S., Guran T., Karakoc F., et\u00a0al. Hypoglycemia is common in children with cystic fibrosis and seen predominantly in females. 2017;18(7):607-13.","DOI":"10.1111\/pedi.12470"},{"issue":"3","key":"10.1016\/j.jcf.2022.07.013_bib0086","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1007\/s13300-016-0194-7","article-title":"Patterns and impact of hypoglycemia, hyperglycemia, and glucose variability on inpatients with insulin-treated cystic fibrosis-related diabetes","volume":"7","author":"Jones","year":"2016","journal-title":"Diabetes Ther"},{"issue":"4","key":"10.1016\/j.jcf.2022.07.013_bib0087","doi-asserted-by":"crossref","first-page":"795","DOI":"10.2337\/dc10-1989","article-title":"Effect of continuous glucose monitoring on hypoglycemia in type 1 diabetes","volume":"34","author":"Battelino","year":"2011","journal-title":"Diabetes Care"},{"issue":"S2","key":"10.1016\/j.jcf.2022.07.013_bib0088","doi-asserted-by":"crossref","first-page":"S2.3","DOI":"10.1089\/dia.2015.0417","article-title":"Continuous glucose monitoring: a review of successes, challenges, and opportunities","volume":"18","author":"Rodbard","year":"2016","journal-title":"Diabetes Technol Ther"},{"issue":"11","key":"10.1016\/j.jcf.2022.07.013_bib0089","article-title":"Continuous glucose monitoring systems for monitoring cystic fibrosis-related diabetes","volume":"11","author":"Toner","year":"2021","journal-title":"Cochrane Database Syst Rev"},{"issue":"6","key":"10.1016\/j.jcf.2022.07.013_bib0090","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1089\/dia.2021.0354","article-title":"The effect of control IQ hybrid closed loop technology on glycemic control in adolescents and adults with cystic fibrosis-related diabetes","volume":"24","author":"Scully","year":"2022","journal-title":"Diabetes Technol Ther"},{"issue":"1","key":"10.1016\/j.jcf.2022.07.013_bib0091","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.jcf.2019.08.002","article-title":"Automated glycemic control with the bionic pancreas in cystic fibrosis-related diabetes: a pilot study","volume":"19","author":"Sherwood","year":"2020","journal-title":"J Cyst Fibros"}],"container-title":["Journal of Cystic Fibrosis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1569199322006336?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1569199322006336?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T21:46:54Z","timestamp":1761601614000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1569199322006336"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1]]},"references-count":91,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2023,1]]}},"alternative-id":["S1569199322006336"],"URL":"https:\/\/doi.org\/10.1016\/j.jcf.2022.07.013","relation":{},"ISSN":["1569-1993"],"issn-type":[{"value":"1569-1993","type":"print"}],"subject":[],"published":{"date-parts":[[2023,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Continuous glucose monitoring versus self-monitoring of blood glucose in the management of cystic fibrosis related diabetes: A systematic review and meta-analysis","name":"articletitle","label":"Article Title"},{"value":"Journal of Cystic Fibrosis","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcf.2022.07.013","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 European Cystic Fibrosis Society. Published by Elsevier B.V.","name":"copyright","label":"Copyright"}]}}