{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T17:20:12Z","timestamp":1792603212851,"version":"4.5.0"},"reference-count":75,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"vor","delay-in-days":366,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.com.au","clinicalkey.es","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JACC: Heart Failure"],"published-print":{"date-parts":[[2024,1]]},"DOI":"10.1016\/j.jchf.2023.08.019","type":"journal-article","created":{"date-parts":[[2023,10,24]],"date-time":"2023-10-24T23:06:11Z","timestamp":1698188771000},"page":"16-27","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":9,"title":["Value of Invasive Hemodynamic Assessments in Patients Supported by\u00a0Continuous-Flow Left Ventricular Assist Devices"],"prefix":"10.1016","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1638-7820","authenticated-orcid":false,"given":"Eduard","family":"Rodenas-Alesina","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3440-0523","authenticated-orcid":false,"given":"Darshan H.","family":"Brahmbhatt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Susanna","family":"Mak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heather J.","family":"Ross","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adriana","family":"Luk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vivek","family":"Rao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2824-1215","authenticated-orcid":false,"given":"Filio","family":"Billia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"3","key":"10.1016\/j.jchf.2023.08.019_bib1","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1016\/j.athoracsur.2021.12.011","article-title":"Twelfth interagency registry for mechanically assisted circulatory support report: readmissions after left ventricular assist device","volume":"113","author":"Shah","year":"2022","journal-title":"Ann Thorac Surg"},{"issue":"3","key":"10.1016\/j.jchf.2023.08.019_bib2","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1097\/MAT.0000000000001486","article-title":"Analysis of trends and outcomes of 90 and 180\u00a0day readmissions after left ventricular assist device implantation","volume":"68","author":"Briasoulis","year":"2022","journal-title":"ASAIO J"},{"issue":"23","key":"10.1016\/j.jchf.2023.08.019_bib3","doi-asserted-by":"crossref","first-page":"2294","DOI":"10.1016\/j.jacc.2021.09.1362","article-title":"Evolution of late right heart failure with left ventricular assist devices and association with outcomes","volume":"78","author":"Rame","year":"2021","journal-title":"J\u00a0Am Coll Cardiol"},{"issue":"6","key":"10.1016\/j.jchf.2023.08.019_bib4","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCHEARTFAILURE.122.009960","article-title":"Use of a pulmonary artery pressure sensor to manage patients with left ventricular assist devices","volume":"16","author":"Thohan","year":"2023","journal-title":"Circ Heart Fail"},{"issue":"4","key":"10.1016\/j.jchf.2023.08.019_bib5","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCHEARTFAILURE.119.006067","article-title":"Impact of hemodynamic ramp test-guided HVAD speed\u00a0and medication adjustments on clinical outcomes","volume":"12","author":"Uriel","year":"2019","journal-title":"Circ Heart Fail"},{"issue":"1","key":"10.1016\/j.jchf.2023.08.019_bib6","doi-asserted-by":"crossref","first-page":"6","DOI":"10.21693\/1933-088X-19.1.6","article-title":"Modern right heart catheterization: beyond simple hemodynamics","volume":"19","author":"Bonno","year":"2020","journal-title":"Adv Pulm Hypertens"},{"issue":"18","key":"10.1016\/j.jchf.2023.08.019_bib7","doi-asserted-by":"crossref","first-page":"1764","DOI":"10.1016\/j.jacc.2012.07.052","article-title":"Development of a novel echocardiography ramp test for speed optimization and diagnosis of device thrombosis in continuous-flow left ventricular assist devices: the Columbia ramp study","volume":"60","author":"Uriel","year":"2012","journal-title":"J\u00a0Am Coll Cardiol"},{"issue":"2","key":"10.1016\/j.jchf.2023.08.019_bib8","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1097\/MAT.0000000000000617","article-title":"Unrecognized left heart failure in LVAD recipients: the role of routine invasive hemodynamic testing","volume":"64","author":"Shah","year":"2018","journal-title":"ASAIO J"},{"issue":"4","key":"10.1016\/j.jchf.2023.08.019_bib9","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1097\/MAT.0000000000000528","article-title":"Cardiac output assessment in patients supported with left ventricular assist device: discordance between thermodilution and indirect Fick cardiac output measurements","volume":"63","author":"Tehrani","year":"2017","journal-title":"ASAIO J"},{"issue":"2","key":"10.1016\/j.jchf.2023.08.019_bib10","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1016\/j.healun.2022.10.021","article-title":"Cardiac output assessment methods in left ventricular assist device patients: a problem of heteroscedasticity","volume":"42","author":"Azih","year":"2023","journal-title":"J\u00a0Heart Lung Transplant"},{"issue":"1","key":"10.1016\/j.jchf.2023.08.019_bib11","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1097\/MAT.0000000000000024","article-title":"The effects of continuous and intermittent reduced speed modes on renal and intestinal perfusion in an ovine model","volume":"60","author":"Tuzun","year":"2014","journal-title":"ASAIO J"},{"issue":"5","key":"10.1016\/j.jchf.2023.08.019_bib12","doi-asserted-by":"crossref","first-page":"1361","DOI":"10.1016\/j.athoracsur.2019.04.050","article-title":"Right atrial pressure waveform predicts right ventricular failure after left ventricular assist device implantation","volume":"108","author":"Samura","year":"2019","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jchf.2023.08.019_bib13","doi-asserted-by":"crossref","DOI":"10.3389\/fcvm.2022.847205","article-title":"Diastolic plateau - invasive hemodynamic marker of adverse outcome among left ventricular assist device patients","volume":"9","author":"Grupper","year":"2022","journal-title":"Front Cardiovasc Med"},{"issue":"4","key":"10.1016\/j.jchf.2023.08.019_bib14","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1016\/j.cardfail.2020.01.012","article-title":"HVAD flow waveform estimates left ventricular filling pressure","volume":"26","author":"Imamura","year":"2020","journal-title":"J\u00a0Card Fail"},{"issue":"1","key":"10.1016\/j.jchf.2023.08.019_bib15","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1097\/MAT.0000000000000604","article-title":"HVAD waveform analysis as a noninvasive marker of pulmonary capillary wedge pressure: a first step toward the development of a smart left ventricular assist device pump","volume":"64","author":"Grinstein","year":"2018","journal-title":"ASAIO J"},{"issue":"7 Pt 1","key":"10.1016\/j.jchf.2023.08.019_bib16","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1016\/j.jcmg.2018.01.026","article-title":"Noninvasive assessment of hemodynamic status in HeartWare left ventricular assist device patients: validation of an echocardiographic approach","volume":"12","author":"Frea","year":"2019","journal-title":"J\u00a0Am Coll Cardiol Img"},{"issue":"4","key":"10.1016\/j.jchf.2023.08.019_bib17","doi-asserted-by":"crossref","first-page":"2846","DOI":"10.1002\/ehf2.13359","article-title":"Effects of echo-optimization of left ventricular assist devices on functional capacity, a randomized controlled trial","volume":"8","author":"Lilliu","year":"2021","journal-title":"ESC Heart Fail"},{"issue":"12","key":"10.1016\/j.jchf.2023.08.019_bib18","doi-asserted-by":"crossref","first-page":"1231","DOI":"10.1016\/j.jacc.2014.06.1188","article-title":"Echocardiographic evaluation of hemodynamics in patients with systolic heart failure supported by a continuous-flow LVAD","volume":"64","author":"Estep","year":"2014","journal-title":"J\u00a0Am Coll Cardiol"},{"issue":"3","key":"10.1016\/j.jchf.2023.08.019_bib19","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1097\/MAT.0000000000000194","article-title":"Relation between pressure and volume unloading during ramp testing in patients supported with a continuous-flow left ventricular assist device","volume":"61","author":"Jung","year":"2015","journal-title":"ASAIO J"},{"issue":"9","key":"10.1016\/j.jchf.2023.08.019_bib20","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1016\/j.cardfail.2018.07.004","article-title":"Echocardiographic predictors of hemodynamics in patients supported with left ventricular assist devices","volume":"24","author":"Grinstein","year":"2018","journal-title":"J\u00a0Card Fail"},{"issue":"5","key":"10.1016\/j.jchf.2023.08.019_bib21","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1002\/ejhf.1372","article-title":"Optimal haemodynamics during left ventricular assist device support are associated with reduced haemocompatibility-related adverse events","volume":"21","author":"Imamura","year":"2019","journal-title":"Eur J Heart Fail"},{"issue":"7","key":"10.1016\/j.jchf.2023.08.019_bib22","article-title":"Decoupling between diastolic pulmonary artery and pulmonary capillary wedge pressures is associated with right ventricular dysfunction and hemocompatibility-related adverse events in patients with left ventricular assist devices","volume":"9","author":"Imamura","year":"2020","journal-title":"J\u00a0Am Heart Assoc"},{"issue":"2","key":"10.1016\/j.jchf.2023.08.019_bib23","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1111\/aor.13792","article-title":"Inadequate left ventricular unloading during ramp is associated with hospitalization or death during left ventricular assist device support","volume":"45","author":"Rosenbaum","year":"2021","journal-title":"Artif Organs"},{"issue":"9","key":"10.1016\/j.jchf.2023.08.019_bib24","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCHEARTFAILURE.117.003882","article-title":"Decoupling between diastolic pulmonary artery pressure and pulmonary capillary wedge pressure as a prognostic factor after continuous flow ventricular assist device implantation","volume":"10","author":"Imamura","year":"2017","journal-title":"Circ Heart Fail"},{"issue":"3","key":"10.1016\/j.jchf.2023.08.019_bib25","first-page":"208","article-title":"Hemodynamic ramp tests in patients with left ventricular assist devices","volume":"4","author":"Uriel","year":"2016","journal-title":"J\u00a0Am Coll Cardiol HF"},{"issue":"11","key":"10.1016\/j.jchf.2023.08.019_bib26","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1016\/j.healun.2010.05.032","article-title":"Echocardiographic assessment of flow across continuous-flow ventricular assist devices at low speeds","volume":"29","author":"George","year":"2010","journal-title":"J\u00a0Heart Lung Transplant"},{"issue":"5","key":"10.1016\/j.jchf.2023.08.019_bib27","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1016\/j.cardfail.2021.01.004","article-title":"Understanding longitudinal changes in pulmonary vascular resistance after left ventricular assist device implantation","volume":"27","author":"Gulati","year":"2021","journal-title":"J\u00a0Card Fail"},{"issue":"2","key":"10.1016\/j.jchf.2023.08.019_bib28","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1097\/MAT.0000000000001214","article-title":"Short-term ventricular structural changes following left ventricular assist device implantation","volume":"67","author":"Sayer","year":"2021","journal-title":"ASAIO J"},{"issue":"3","key":"10.1016\/j.jchf.2023.08.019_bib29","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1097\/MAT.0000000000001497","article-title":"Variability in blood pressure assessment in patients supported with the HeartMate 3TM","volume":"68","author":"Cowger","year":"2022","journal-title":"ASAIO J"},{"issue":"18","key":"10.1016\/j.jchf.2023.08.019_bib30","doi-asserted-by":"crossref","first-page":"1782","DOI":"10.1016\/j.jacc.2021.08.047","article-title":"Matrix-degrading enzyme expression and aortic fibrosis during continuous-flow left ventricular mechanical support","volume":"78","author":"Ambardekar","year":"2021","journal-title":"J\u00a0Am Coll Cardiol"},{"issue":"1","key":"10.1016\/j.jchf.2023.08.019_bib31","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1097\/MAT.0000000000001159","article-title":"Correction of high afterload improves low cardiac output in patients supported on left ventricular assist device therapy","volume":"67","author":"Rosenbaum","year":"2021","journal-title":"ASAIO J"},{"issue":"6","key":"10.1016\/j.jchf.2023.08.019_bib32","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCHEARTFAILURE.122.009671","article-title":"Ramping up the pressure on the right ventricle","volume":"15","author":"Savaris","year":"2022","journal-title":"Circ Heart Fail"},{"issue":"21","key":"10.1016\/j.jchf.2023.08.019_bib33","doi-asserted-by":"crossref","first-page":"2016","DOI":"10.1161\/CIRCULATIONAHA.120.046415","article-title":"Prospective multicenter study of myocardial recovery using left ventricular assist devices (RESTAGE-HF [Remission from Stage D Heart\u00a0Failure]): medium-term and primary end point results","volume":"142","author":"Birks","year":"2020","journal-title":"Circulation"},{"issue":"9","key":"10.1016\/j.jchf.2023.08.019_bib34","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1016\/j.cardfail.2018.08.003","article-title":"Decoupling between diastolic pulmonary arterial pressure and pulmonary arterial wedge pressure at incremental left ventricular assist device (LVAD) speeds is associated with worse prognosis after LVAD implantation","volume":"24","author":"Imamura","year":"2018","journal-title":"J\u00a0Card Fail"},{"key":"10.1016\/j.jchf.2023.08.019_bib35","doi-asserted-by":"crossref","DOI":"10.3389\/fcvm.2022.1040251","article-title":"Prediction, prevention, and management of right ventricular failure after left ventricular assist device implantation: a comprehensive review","volume":"9","author":"Rodenas-Alesina","year":"2022","journal-title":"Front Cardiovasc Med"},{"issue":"3","key":"10.1016\/j.jchf.2023.08.019_bib36","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1097\/MAT.0000000000000483","article-title":"Pump speed optimization in stable patients with a left ventricular assist device","volume":"63","author":"Couperus","year":"2017","journal-title":"ASAIO J"},{"issue":"1","key":"10.1016\/j.jchf.2023.08.019_bib37","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCHEARTFAILURE.121.009101","article-title":"Invasive right ventricular pressure-volume analysis: basic principles, clinical applications, and practical recommendations","volume":"15","author":"Brener","year":"2022","journal-title":"Circ Heart Fail"},{"issue":"2 Pt 1","key":"10.1016\/j.jchf.2023.08.019_bib38","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.jcmg.2016.12.019","article-title":"3D morphological changes in LV and RV during LVAD ramp studies","volume":"11","author":"Addetia","year":"2018","journal-title":"J\u00a0Am Coll Cardiol Img"},{"issue":"9","key":"10.1016\/j.jchf.2023.08.019_bib39","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1016\/j.cardfail.2021.04.019","article-title":"Right ventricular pressure-volume analysis during left ventricular assist device speed optimization studies: insights into interventricular interactions and right ventricular failure","volume":"27","author":"Brener","year":"2021","journal-title":"J\u00a0Card Fail"},{"issue":"3","key":"10.1016\/j.jchf.2023.08.019_bib40","doi-asserted-by":"crossref","first-page":"e40","DOI":"10.1097\/MAT.0000000000000640","article-title":"Orthostatic hypotension in patients with left ventricular assist devices: acquired autonomic dysfunction","volume":"64","author":"Fudim","year":"2018","journal-title":"ASAIO J"},{"issue":"23","key":"10.1016\/j.jchf.2023.08.019_bib41","doi-asserted-by":"crossref","first-page":"2241","DOI":"10.1056\/NEJMoa0909938","article-title":"Advanced heart failure treated with continuous-flow left ventricular assist device","volume":"361","author":"Slaughter","year":"2009","journal-title":"N\u00a0Engl J Med"},{"issue":"4","key":"10.1016\/j.jchf.2023.08.019_bib42","first-page":"291","article-title":"Echocardiographic ramp test for continuous-flow left ventricular assist devices: do loading conditions matter?","volume":"3","author":"Adatya","year":"2015","journal-title":"J\u00a0Am Coll Cardiol HF"},{"issue":"10","key":"10.1016\/j.jchf.2023.08.019_bib43","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1016\/j.cardfail.2015.06.010","article-title":"Left ventricular decompression during speed optimization ramps in patients supported by continuous-flow left ventricular assist devices: device-specific performance characteristics and impact on diagnostic algorithms","volume":"21","author":"Uriel","year":"2015","journal-title":"J\u00a0Card Fail"},{"issue":"6","key":"10.1016\/j.jchf.2023.08.019_bib44","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1016\/j.jcmg.2015.06.020","article-title":"Accurate quantification methods for aortic insufficiency severity in patients with LVAD: role of diastolic flow acceleration and systolic-to-diastolic peak velocity ratio of outflow cannula","volume":"9","author":"Grinstein","year":"2016","journal-title":"J\u00a0Am Coll Cardiol Img"},{"issue":"8","key":"10.1016\/j.jchf.2023.08.019_bib45","doi-asserted-by":"crossref","first-page":"976","DOI":"10.1016\/j.healun.2016.05.009","article-title":"Novel echocardiographic parameters of aortic insufficiency in continuous-flow left ventricular assist devices and clinical outcome","volume":"35","author":"Grinstein","year":"2016","journal-title":"J\u00a0Heart Lung Transplant"},{"issue":"7","key":"10.1016\/j.jchf.2023.08.019_bib46","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/j.cardfail.2017.04.012","article-title":"The hemodynamic effects of aortic insufficiency in patients supported with continuous-flow left ventricular assist devices","volume":"23","author":"Sayer","year":"2017","journal-title":"J\u00a0Card Fail"},{"issue":"5","key":"10.1016\/j.jchf.2023.08.019_bib47","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1016\/j.cardfail.2020.01.020","article-title":"Longitudinal trajectories of hemodynamics following left ventricular assist device implantation","volume":"26","author":"Fujino","year":"2020","journal-title":"J\u00a0Card Fail"},{"issue":"2","key":"10.1016\/j.jchf.2023.08.019_bib48","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1097\/MAT.0000000000000467","article-title":"Pulmonary arterial compliance improves rapidly after left ventricular assist device implantation","volume":"63","author":"Masri","year":"2017","journal-title":"ASAIO J"},{"issue":"4","key":"10.1016\/j.jchf.2023.08.019_bib49","first-page":"971","article-title":"Reversibility of fixed pulmonary hypertension in left ventricular assist device support recipients","volume":"40","author":"Mikus","year":"2011","journal-title":"Eur J Cardiothorac Surg"},{"issue":"3","key":"10.1016\/j.jchf.2023.08.019_bib50","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.cardfail.2016.06.421","article-title":"Left ventricular assist devices or inotropes for decreasing pulmonary vascular resistance in patients with pulmonary hypertension listed for heart transplantation","volume":"23","author":"Al-Kindi","year":"2017","journal-title":"J\u00a0Card Fail"},{"issue":"7","key":"10.1016\/j.jchf.2023.08.019_bib51","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1016\/j.healun.2016.01.1225","article-title":"Right ventricular afterload sensitivity dramatically increases after left ventricular assist device implantation: a multi-center hemodynamic analysis","volume":"35","author":"Houston","year":"2016","journal-title":"J\u00a0Heart Lung Transplant"},{"issue":"4","key":"10.1016\/j.jchf.2023.08.019_bib52","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1016\/j.healun.2012.12.018","article-title":"Impact of continuous-flow left ventricular assist device support on right ventricular function","volume":"32","author":"Morgan","year":"2013","journal-title":"J\u00a0Heart Lung Transplant"},{"issue":"12","key":"10.1016\/j.jchf.2023.08.019_bib53","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1111\/aor.12733","article-title":"Cardiac index declines during long-term left ventricular device support","volume":"40","author":"Kalathiya","year":"2016","journal-title":"Artif Organs"},{"issue":"2","key":"10.1016\/j.jchf.2023.08.019_bib54","first-page":"89","article-title":"Postimplant phosphodiesterase-5 inhibitor use in centrifugal flow left ventricular assist devices","volume":"10","author":"Xanthopoulos","year":"2022","journal-title":"J\u00a0Am Coll Cardiol HF"},{"issue":"4","key":"10.1016\/j.jchf.2023.08.019_bib55","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1016\/j.cardfail.2020.12.018","article-title":"Phosphodiesterase-5 inhibitors and outcomes during left ventricular assist device support: a systematic review and meta-analysis","volume":"27","author":"Kittipibul","year":"2021","journal-title":"J\u00a0Card Fail"},{"issue":"4","key":"10.1016\/j.jchf.2023.08.019_bib56","doi-asserted-by":"crossref","first-page":"S12","DOI":"10.1016\/j.healun.2021.01.1767","article-title":"First results of soprano: macitentan in patients (pts) with pulmonary hypertension (PH) post-left ventricular assist device (LVAD) implantation","volume":"40","author":"Frantz","year":"2021","journal-title":"J\u00a0Heart Lung Transplant"},{"issue":"4","key":"10.1016\/j.jchf.2023.08.019_bib57","doi-asserted-by":"crossref","first-page":"2728","DOI":"10.1002\/ehf2.14366","article-title":"Phosphodiesterase-5 inhibitors for left ventricular assist device implantation complicated by right ventricular failure","volume":"10","author":"Papathanasiou","year":"2023","journal-title":"ESC Heart Fail"},{"issue":"15","key":"10.1016\/j.jchf.2023.08.019_bib58","doi-asserted-by":"crossref","first-page":"1255","DOI":"10.1093\/eurheartj\/ehx700","article-title":"Sildenafil for improving outcomes in patients with corrected valvular heart disease and persistent pulmonary hypertension: a multicenter, double-blind, randomized clinical trial","volume":"39","author":"Bermejo","year":"2018","journal-title":"Eur Heart J"},{"issue":"4","key":"10.1016\/j.jchf.2023.08.019_bib59","doi-asserted-by":"crossref","first-page":"2170","DOI":"10.1002\/ehf2.13952","article-title":"Sacubitril\/valsartan affects pulmonary arterial pressure in heart failure with preserved ejection fraction and pulmonary hypertension","volume":"9","author":"Codina","year":"2022","journal-title":"ESC Heart Fail"},{"issue":"5","key":"10.1016\/j.jchf.2023.08.019_bib60","first-page":"360","article-title":"levosimendan improves hemodynamics and exercise tolerance in PH-HFpEF: results of the randomized placebo-controlled HELP trial","volume":"9","author":"Burkhoff","year":"2021","journal-title":"J\u00a0Am Coll Cardiol HF"},{"issue":"1","key":"10.1016\/j.jchf.2023.08.019_bib61","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1016\/j.jacc.2023.04.045","article-title":"Adverse hemodynamic consequences of continuous left ventricular mechanical support: JACC Review Topic of the Week","volume":"82","author":"Grinstein","year":"2023","journal-title":"J\u00a0Am Coll Cardiol"},{"issue":"10","key":"10.1016\/j.jchf.2023.08.019_bib62","first-page":"758","article-title":"Prognostic value of peak oxygen uptake in patients supported with left ventricular assist devices (PRO-VAD)","volume":"9","author":"Mirza","year":"2021","journal-title":"J\u00a0Am Coll Cardiol HF"},{"issue":"4","key":"10.1016\/j.jchf.2023.08.019_bib63","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1016\/j.healun.2014.11.004","article-title":"Effect of exercise and pump speed modulation on invasive hemodynamics in patients with centrifugal continuous-flow left ventricular assist devices","volume":"34","author":"Muthiah","year":"2015","journal-title":"J\u00a0Heart Lung Transplant"},{"issue":"1","key":"10.1016\/j.jchf.2023.08.019_bib64","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1097\/MAT.0000000000001169","article-title":"High right ventricular afterload is associated with impaired exercise tolerance in patients with left ventricular assist devices","volume":"67","author":"Ton","year":"2021","journal-title":"ASAIO J"},{"issue":"4","key":"10.1016\/j.jchf.2023.08.019_bib65","first-page":"291","article-title":"Hemodynamic response to exercise in patients supported by continuous flow left ventricular assist devices","volume":"8","author":"Moss","year":"2020","journal-title":"J\u00a0Am Coll Cardiol HF"},{"issue":"2","key":"10.1016\/j.jchf.2023.08.019_bib66","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.healun.2020.11.009","article-title":"Right ventricular function and cardiopulmonary performance among patients with heart failure supported by durable mechanical circulatory support devices","volume":"40","author":"Tran","year":"2021","journal-title":"J\u00a0Heart Lung Transplant"},{"issue":"9","key":"10.1016\/j.jchf.2023.08.019_bib67","first-page":"703","article-title":"Further peripheral vascular dysfunction in heart failure patients with a continuous-flow left ventricular assist device: the role of pulsatility","volume":"3","author":"Witman","year":"2015","journal-title":"J\u00a0Am Coll Cardiol HF"},{"issue":"3","key":"10.1016\/j.jchf.2023.08.019_bib68","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1002\/ehf2.12629","article-title":"Outcomes of patients after successful left ventricular assist device explantation: a EUROMACS study","volume":"7","author":"Antonides","year":"2020","journal-title":"ESC Heart Fail"},{"issue":"4","key":"10.1016\/j.jchf.2023.08.019_bib69","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1016\/j.cjca.2018.11.015","article-title":"Evaluation of cardiac recovery in ventricular assist device recipients: particularities, reliability, and practical challenges","volume":"35","author":"Dandel","year":"2019","journal-title":"Can J Cardiol"},{"issue":"8","key":"10.1016\/j.jchf.2023.08.019_bib70","doi-asserted-by":"crossref","first-page":"880","DOI":"10.1016\/j.healun.2017.02.022","article-title":"Hemodynamic phenotyping based on exercise catheterization predicts outcome in patients with heart failure and reduced ejection fraction","volume":"36","author":"Rieth","year":"2017","journal-title":"J\u00a0Heart Lung Transplant"},{"issue":"5","key":"10.1016\/j.jchf.2023.08.019_bib71","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCHEARTFAILURE.117.004750","article-title":"Pulmonary capillary wedge pressure patterns during exercise predict exercise capacity and incident heart failure","volume":"11","author":"Eisman","year":"2018","journal-title":"Circ Heart Fail"},{"issue":"1","key":"10.1016\/j.jchf.2023.08.019_bib72","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCHEARTFAILURE.116.003694","article-title":"Predicting success: left ventricular assist device explantation evaluation protocol using comprehensive cardiopulmonary exercise testing","volume":"10","author":"Steiner","year":"2017","journal-title":"Circ Heart Fail"},{"issue":"7","key":"10.1016\/j.jchf.2023.08.019_bib73","doi-asserted-by":"crossref","first-page":"1124","DOI":"10.1253\/circj.CJ-20-0070","article-title":"Recovery from exhaustion of the Frank-Starling mechanism by mechanical unloading with a continuous-flow ventricular assist device","volume":"84","author":"Saito","year":"2020","journal-title":"Circ J"},{"issue":"4","key":"10.1016\/j.jchf.2023.08.019_bib74","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1002\/ejhf.52","article-title":"Effect of increasing pump speed during exercise on peak oxygen uptake in heart failure patients supported with a continuous-flow left ventricular assist device. A double-blind randomized study","volume":"16","author":"Jung","year":"2014","journal-title":"Eur J Heart Fail"},{"issue":"2","key":"10.1016\/j.jchf.2023.08.019_bib75","doi-asserted-by":"crossref","first-page":"e29","DOI":"10.1097\/MAT.0000000000000976","article-title":"Rate response pacing in left ventricular assist device patients","volume":"66","author":"Alvarez Villela","year":"2020","journal-title":"ASAIO J"}],"container-title":["JACC: Heart Failure"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2213177923005462?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2213177923005462?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T01:48:44Z","timestamp":1735696124000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2213177923005462"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1]]},"references-count":75,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024,1]]}},"alternative-id":["S2213177923005462"],"URL":"https:\/\/doi.org\/10.1016\/j.jchf.2023.08.019","relation":{},"ISSN":["2213-1779"],"issn-type":[{"value":"2213-1779","type":"print"}],"subject":[],"published":{"date-parts":[[2024,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Value of Invasive Hemodynamic Assessments in Patients Supported by\u00a0Continuous-Flow Left Ventricular Assist Devices","name":"articletitle","label":"Article Title"},{"value":"JACC: Heart Failure","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jchf.2023.08.019","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 the American College of Cardiology Foundation. Published by Elsevier.","name":"copyright","label":"Copyright"}]}}