{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,26]],"date-time":"2026-10-26T20:53:39Z","timestamp":1793048019657,"version":"4.5.0"},"reference-count":32,"publisher":"Elsevier BV","issue":"9","license":[{"start":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T00:00:00Z","timestamp":1725148800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T00:00:00Z","timestamp":1725148800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,4,30]],"date-time":"2024-04-30T00:00:00Z","timestamp":1714435200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100020940","name":"National Institutes of Health","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100020940","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000038","name":"U.S. Food and Drug Administration","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000038","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100006279","name":"Abbott Cardiovascular","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100006279","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jacc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JACC: Heart Failure"],"published-print":{"date-parts":[[2024,9]]},"DOI":"10.1016\/j.jchf.2024.04.013","type":"journal-article","created":{"date-parts":[[2024,5,7]],"date-time":"2024-05-07T15:41:55Z","timestamp":1715096515000},"page":"1540-1549","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":54,"title":["Evaluation of the Hemocompatibility of\u00a0the Direct Oral Anticoagulant Apixaban in Left Ventricular Assist Devices"],"prefix":"10.1016","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8175-168X","authenticated-orcid":false,"given":"Palak","family":"Shah","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mary","family":"Looby","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3996-6721","authenticated-orcid":false,"given":"Matthew","family":"Dimond","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pramita","family":"Bagchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bhruga","family":"Shah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Iyad","family":"Isseh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Allman T.","family":"Rollins","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmad A.","family":"Abdul-Aziz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jamie","family":"Kennedy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel G.","family":"Tang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katherine M.","family":"Klein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samantha","family":"Casselman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christen","family":"Vermeulen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wendy","family":"Sheaffer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meredith","family":"Snipes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shashank S.","family":"Sinha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher M.","family":"O\u2019Connor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jchf.2024.04.013_bib1","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.1001\/jama.2022.16197","article-title":"Five-year outcomes in patients with fully magnetically levitated vs axial-flow left ventricular assist devices in the MOMENTUM 3 randomized trial","volume":"328","author":"Mehra","year":"2022","journal-title":"JAMA"},{"key":"10.1016\/j.jchf.2024.04.013_bib2","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1016\/j.athoracsur.2022.11.023","article-title":"The Society of Thoracic Surgeons Intermacs 2022 annual report: focus on the 2018 heart transplant allocation system","volume":"115","author":"Yuzefpolskaya","year":"2023","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jchf.2024.04.013_bib3","doi-asserted-by":"crossref","first-page":"1164","DOI":"10.1016\/j.healun.2017.05.008","article-title":"Bleeding and thrombosis associated with ventricular assist device therapy","volume":"36","author":"Shah","year":"2017","journal-title":"J\u00a0Heart Lung Transplant"},{"key":"10.1016\/j.jchf.2024.04.013_bib4","doi-asserted-by":"crossref","first-page":"2003","DOI":"10.1161\/CIRCULATIONAHA.117.028303","article-title":"Hemocompatibility-related outcomes in the MOMENTUM 3 trial at 6\u00a0months: a randomized controlled study of a fully magnetically levitated pump in advanced heart failure","volume":"135","author":"Uriel","year":"2017","journal-title":"Circulation"},{"key":"10.1016\/j.jchf.2024.04.013_bib5","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1016\/j.athoracsur.2021.12.011","article-title":"Twelfth Interagency Registry for Mechanically Assisted Circulatory Support report: readmissions after left ventricular assist device","volume":"113","author":"Shah","year":"2022","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jchf.2024.04.013_bib6","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.athoracsur.2023.11.004","article-title":"The Society of Thoracic Surgeons Intermacs 2023 annual report: focus on magnetically levitated devices","volume":"117","author":"Jorde","year":"2024","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jchf.2024.04.013_bib7","doi-asserted-by":"crossref","first-page":"4693","DOI":"10.1182\/bloodadvances.2020001830","article-title":"American Society of Hematology 2020 guidelines for management of venous thromboembolism: treatment of deep vein thrombosis and pulmonary embolism","volume":"4","author":"Ortel","year":"2020","journal-title":"Blood Adv"},{"issue":"1","key":"10.1016\/j.jchf.2024.04.013_bib8","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1016\/j.jacc.2019.01.011","volume":"74","author":"January","year":"2019","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jchf.2024.04.013_bib9","article-title":"Increased thromboembolic events with dabigatran compared with vitamin K antagonism in left ventricular assist device patients: a randomized controlled pilot trial","volume":"10","author":"Andreas","year":"2017","journal-title":"Circ Heart Fail"},{"key":"10.1016\/j.jchf.2024.04.013_bib10","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCHEARTFAILURE.120.007231","article-title":"Ex\u00a0vivo assessment of different oral anticoagulant regimens on pump thrombosis in a HeartWare ventricular assist device","volume":"14","author":"Rao","year":"2021","journal-title":"Circ Heart Fail"},{"key":"10.1016\/j.jchf.2024.04.013_bib11","doi-asserted-by":"crossref","first-page":"981","DOI":"10.1056\/NEJMoa1107039","article-title":"Apixaban versus warfarin in patients with atrial fibrillation","volume":"365","author":"Granger","year":"2011","journal-title":"N\u00a0Engl J Med"},{"issue":"6","key":"10.1016\/j.jchf.2024.04.013_bib12","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1016\/j.cardfail.2023.10.473","article-title":"Design and rationale for the Direct Oral Anti-Coagulant Apixaban in Left Ventricular Assist Devices (DOAC LVAD) study","volume":"30","author":"Dimond","year":"2024","journal-title":"J\u00a0Card Fail"},{"key":"10.1016\/j.jchf.2024.04.013_bib13","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1016\/j.jbi.2008.08.010","article-title":"Research electronic data capture (REDCap)\u2014a metadata-driven methodology and workflow process for providing translational research informatics support","volume":"42","author":"Harris","year":"2009","journal-title":"J\u00a0Biomed Inform"},{"key":"10.1016\/j.jchf.2024.04.013_bib14","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1055\/s-0038-1651587","article-title":"A\u00a0method to determine the optimal intensity of oral anticoagulant therapy","volume":"69","author":"Rosendaal","year":"1993","journal-title":"Thromb Haemost"},{"key":"10.1016\/j.jchf.2024.04.013_bib15","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1016\/j.healun.2020.03.010","article-title":"Updated definitions of adverse events for trials and registries of mechanical circulatory support: a consensus statement of the mechanical circulatory support academic research consortium","volume":"39","author":"Kormos","year":"2020","journal-title":"J\u00a0Heart Lung Transplant"},{"key":"10.1016\/j.jchf.2024.04.013_bib16","series-title":"ANOVA: Repeated Measures","author":"Girden","year":"1992"},{"key":"10.1016\/j.jchf.2024.04.013_bib17","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1111\/j.2517-6161.1995.tb02031.x","article-title":"Controlling the false discovery rate: a practical and powerful approach to multiple testing","volume":"57","author":"Benjamini","year":"1995","journal-title":"J\u00a0R Stat Soc Series B Stat Methodol"},{"key":"10.1016\/j.jchf.2024.04.013_bib18","first-page":"347","article-title":"Regression-based tests for overdispersion in the Poisson model","volume":"46","author":"Cameron","year":"1990","journal-title":"J\u00a0Econometrics"},{"key":"10.1016\/j.jchf.2024.04.013_bib19","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1161\/ATVBAHA.117.309223","article-title":"Anticoagulation for mechanical heart valves: will oral factor Xa inhibitors be effective?","volume":"37","author":"Chan","year":"2017","journal-title":"Arterioscler Thromb Vasc Biol"},{"key":"10.1016\/j.jchf.2024.04.013_bib20","article-title":"Dabigatran is less effective than warfarin at attenuating mechanical heart valve-induced thrombin generation","volume":"4","author":"Jaffer","year":"2015","journal-title":"J\u00a0Am Heart Assoc"},{"issue":"suppl 1","key":"10.1016\/j.jchf.2024.04.013_bib21","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1111\/j.1538-7836.2007.02473.x","article-title":"Factor Xa or thrombin: is factor Xa a better target?","volume":"5","author":"Ansell","year":"2007","journal-title":"J\u00a0Thromb Haemost"},{"key":"10.1016\/j.jchf.2024.04.013_bib22","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1097\/MAT.0b013e3181dfbab5","article-title":"Design concepts and principle of operation of the HeartWare ventricular assist system","volume":"56","author":"Larose","year":"2010","journal-title":"ASAIO J"},{"key":"10.1016\/j.jchf.2024.04.013_bib23","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1097\/MAT.0b013e3180536694","article-title":"Design features, developmental status, and experimental results with the HeartMate III centrifugal left ventricular assist system with a magnetically levitated rotor","volume":"53","author":"Farrar","year":"2007","journal-title":"ASAIO J"},{"key":"10.1016\/j.jchf.2024.04.013_bib24","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1016\/j.athoracsur.2019.12.005","article-title":"The Society of Thoracic Surgeons Intermacs 2019 annual report: the changing landscape of devices and indications","volume":"109","author":"Teuteberg","year":"2020","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jchf.2024.04.013_bib25","doi-asserted-by":"crossref","first-page":"E123","DOI":"10.1111\/aor.13848","article-title":"The use of direct oral anticoagulants in patients with ventricular assist devices: is there hope for Factor Xa inhibition?","volume":"45","author":"Meredith","year":"2021","journal-title":"Artif Organs"},{"key":"10.1016\/j.jchf.2024.04.013_bib26","first-page":"818","article-title":"The HVAD left ventricular assist device: risk factors for neurological events and risk mitigation strategies","volume":"3","author":"Teuteberg","year":"2015","journal-title":"J\u00a0Am Coll Cardiol HF"},{"key":"10.1016\/j.jchf.2024.04.013_bib27","doi-asserted-by":"crossref","DOI":"10.1001\/jamanetworkopen.2021.20064","article-title":"Oral anticoagulants for nonvalvular atrial fibrillation in patients with high risk of gastrointestinal bleeding","volume":"4","author":"Lip","year":"2021","journal-title":"JAMA Netw Open"},{"issue":"22","key":"10.1016\/j.jchf.2024.04.013_bib28","doi-asserted-by":"crossref","first-page":"2171","DOI":"10.1001\/jama.2023.23204","article-title":"Aspirin and hemocompatibility events with a left ventricular assist device in advanced heart failure: the ARIES-HM3 randomized clinical trial","volume":"330","author":"Mehra","year":"2023","journal-title":"JAMA"},{"key":"10.1016\/j.jchf.2024.04.013_bib29","first-page":"3268","article-title":"Clinical outcomes in patients with atrial fibrillation according to sex during anticoagulation with apixaban or warfarin: a secondary analysis of a randomized controlled trial","volume":"36","author":"Vinereanu","year":"2015","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jchf.2024.04.013_bib30","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/j.jacc.2018.04.066","article-title":"Sex-based differences in outcomes of oral anticoagulation in patients with atrial fibrillation","volume":"72","author":"Law","year":"2018","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jchf.2024.04.013_bib31","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1111\/aor.13116","article-title":"Meta-analysis of time in therapeutic range in continuous-flow left ventricular assist device patients receiving warfarin","volume":"42","author":"Martinez","year":"2018","journal-title":"Artif Organs"},{"key":"10.1016\/j.jchf.2024.04.013_bib32","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1097\/MAT.0000000000000449","article-title":"Time in therapeutic range for left ventricular assist device patients anticoagulated with warfarin: a correlation to clinical outcomes","volume":"63","author":"Halder","year":"2017","journal-title":"ASAIO J"}],"container-title":["JACC: Heart Failure"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2213177924003330?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2213177924003330?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T20:37:54Z","timestamp":1787171874000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2213177924003330"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9]]},"references-count":32,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2024,9]]}},"alternative-id":["S2213177924003330"],"URL":"https:\/\/doi.org\/10.1016\/j.jchf.2024.04.013","relation":{},"ISSN":["2213-1779"],"issn-type":[{"value":"2213-1779","type":"print"}],"subject":[],"published":{"date-parts":[[2024,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Evaluation of the Hemocompatibility of\u00a0the Direct Oral Anticoagulant Apixaban in Left Ventricular Assist Devices","name":"articletitle","label":"Article Title"},{"value":"JACC: Heart Failure","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jchf.2024.04.013","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.","name":"copyright","label":"Copyright"}]}}