{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T09:02:45Z","timestamp":1784019765552,"version":"3.55.0"},"reference-count":25,"publisher":"Elsevier BV","issue":"8","license":[{"start":{"date-parts":[[2012,8,1]],"date-time":"2012-08-01T00:00:00Z","timestamp":1343779200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2012,8,1]],"date-time":"2012-08-01T00:00:00Z","timestamp":1343779200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2013,8,1]],"date-time":"2013-08-01T00:00:00Z","timestamp":1375315200000},"content-version":"vor","delay-in-days":365,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jacc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JACC: Cardiovascular Interventions"],"published-print":{"date-parts":[[2012,8]]},"DOI":"10.1016\/j.jcin.2012.04.011","type":"journal-article","created":{"date-parts":[[2012,8,20]],"date-time":"2012-08-20T17:08:37Z","timestamp":1345482517000},"page":"858-865","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":96,"title":["Impact of Paravalvular Leakage on Outcome in Patients After Transcatheter Aortic Valve Implantation"],"prefix":"10.1016","volume":"5","author":[{"given":"Mariuca","family":"Vasa-Nicotera","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan-Malte","family":"Sinning","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Derek","family":"Chin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tiong Keng","family":"Lim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomasz","family":"Spyt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hasan","family":"Jilaihawi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eberhard","family":"Grube","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nikos","family":"Werner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Georg","family":"Nickenig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Kovac","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jcin.2012.04.011_bib1","doi-asserted-by":"crossref","first-page":"1597","DOI":"10.1056\/NEJMoa1008232","article-title":"Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery","volume":"363","author":"Leon","year":"2010","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jcin.2012.04.011_bib2","doi-asserted-by":"crossref","first-page":"2187","DOI":"10.1056\/NEJMoa1103510","article-title":"Transcatheter versus surgical aortic-valve replacement in high-risk patients","volume":"364","author":"Smith","year":"2011","journal-title":"N Engl J Med"},{"key":"10.1016\/j.jcin.2012.04.011_bib3","doi-asserted-by":"crossref","first-page":"3006","DOI":"10.1161\/01.CIR.0000047200.36165.B8","article-title":"Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description","volume":"106","author":"Cribier","year":"2002","journal-title":"Circulation"},{"key":"10.1016\/j.jcin.2012.04.011_bib4","doi-asserted-by":"crossref","first-page":"1616","DOI":"10.1161\/CIRCULATIONAHA.106.639450","article-title":"Percutaneous implantation of the CoreValve self-expanding valve prosthesis in high-risk patients with aortic valve disease: the Siegburg first-in-man study","volume":"114","author":"Grube","year":"2006","journal-title":"Circulation"},{"key":"10.1016\/j.jcin.2012.04.011_bib5","doi-asserted-by":"crossref","first-page":"3009","DOI":"10.1161\/CIRCULATIONAHA.108.837807","article-title":"Transcatheter aortic valve implantation: impact on clinical and valve-related outcomes","volume":"119","author":"Webb","year":"2009","journal-title":"Circulation"},{"key":"10.1016\/j.jcin.2012.04.011_bib6","doi-asserted-by":"crossref","first-page":"1080","DOI":"10.1016\/j.jacc.2009.12.014","article-title":"Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk acute and late outcomes of the multicenter Canadian experience","volume":"55","author":"Rod\u00e9s-Cabau","year":"2010","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jcin.2012.04.011_bib7","doi-asserted-by":"crossref","first-page":"2151","DOI":"10.1016\/j.jacc.2011.05.063","article-title":"Clinical outcomes of patients with severe aortic stenosis at increased surgical risk according to treatment modality","volume":"58","author":"Wenaweser","year":"2011","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jcin.2012.04.011_bib8","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1093\/eurheartj\/ehq339","article-title":"Transcatheter aortic valve implantation: first results from a multi-centre real-world registry","volume":"32","author":"Zahn","year":"2011","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jcin.2012.04.011_bib9","doi-asserted-by":"crossref","first-page":"1134","DOI":"10.1016\/j.jacc.2011.11.048","article-title":"Aortic regurgitation index defines severity of periprosthetic regurgitation and predicts outcome in patients after transcatheter aortic valve implantation","volume":"59","author":"Sinning","year":"2012","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jcin.2012.04.011_bib10","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1161\/CIRCULATIONAHA.110.946533","article-title":"Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis","volume":"123","author":"Tamburino","year":"2011","journal-title":"Circulation"},{"key":"10.1016\/j.jcin.2012.04.011_bib11","doi-asserted-by":"crossref","first-page":"57","DOI":"10.4244\/EIJV7I8A12","article-title":"Haemodynamic evaluation of aortic regurgitation after transcatheter aortic valve implantation using cardiovascular magnetic resonance","volume":"6","author":"Sherif","year":"2011","journal-title":"EuroIntervention"},{"key":"10.1016\/j.jcin.2012.04.011_bib12","first-page":"446","article-title":"Correlates on MSCT of paravalvular aortic regurgitation after transcatheter aortic valve implantation using the Medtronic CoreValve prosthesis","volume":"78","author":"Schultz","year":"2011","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jcin.2012.04.011_bib13","first-page":"432","article-title":"Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilatation","volume":"78","author":"Takagi","year":"2011","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jcin.2012.04.011_bib14","doi-asserted-by":"crossref","first-page":"821","DOI":"10.1016\/j.jcin.2009.07.003","article-title":"Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence","volume":"2","author":"D\u00e9taint","year":"2009","journal-title":"J Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcin.2012.04.011_bib15","doi-asserted-by":"crossref","first-page":"1883","DOI":"10.1016\/j.jacc.2009.01.060","article-title":"Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis","volume":"53","author":"Clavel","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jcin.2012.04.011_bib16","doi-asserted-by":"crossref","first-page":"899","DOI":"10.1136\/hrt.2010.217158","article-title":"Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome","volume":"97","author":"Abdel-Wahab","year":"2011","journal-title":"Heart"},{"key":"10.1016\/j.jcin.2012.04.011_bib17","doi-asserted-by":"crossref","first-page":"1141","DOI":"10.1016\/j.jcin.2010.09.009","article-title":"Renal function as predictor of mortality in patients after percutaneous transcatheter aortic valve implantation","volume":"3","author":"Sinning","year":"2010","journal-title":"J Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcin.2012.04.011_bib18","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1093\/eurheartj\/ehq406","article-title":"Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the valve academic Research Consortium","volume":"32","author":"Leon","year":"2011","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jcin.2012.04.011_bib19","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1016\/j.echo.2009.07.013","article-title":"Recommendations for evaluation of prosthetic valves with echocardiography and Doppler ultrasound","volume":"22","author":"Zoghbi","year":"2009","journal-title":"J Am Soc Echocardiogr"},{"key":"10.1016\/j.jcin.2012.04.011_bib20","doi-asserted-by":"crossref","first-page":"2189","DOI":"10.1093\/eurheartj\/ehr259","article-title":"EAE\/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease","volume":"32","author":"Zamorano","year":"2011","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jcin.2012.04.011_bib21","doi-asserted-by":"crossref","first-page":"1593","DOI":"10.1016\/0002-9149(84)90585-X","article-title":"Limitations of qualitative angiographic grading in aortic or mitral regurgitation","volume":"53","author":"Croft","year":"1984","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jcin.2012.04.011_bib22","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1016\/0002-9149(64)90027-X","article-title":"Left retrograde cardioangiography in acquired cardiac disease: technic, indications and interpretations in 700 cases","volume":"14","author":"Sellers","year":"1964","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jcin.2012.04.011_bib23","doi-asserted-by":"crossref","first-page":"1623","DOI":"10.1016\/j.jacc.2010.06.035","article-title":"Anatomic and procedural predictors of paravalvular aortic regurgitation after implantation of the Medtronic CoreValve bioprosthesis","volume":"56","author":"Sherif","year":"2010","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.jcin.2012.04.011_bib24","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1093\/eurheartj\/ehp537","article-title":"Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-Corevalve bioprosthesis","volume":"31","author":"Jilaihawi","year":"2010","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jcin.2012.04.011_bib25","doi-asserted-by":"crossref","first-page":"1114","DOI":"10.1016\/j.ahj.2011.01.025","article-title":"Clinical outcome and predictors for adverse events after transcatheter aortic valve implantation with the use of different devices and access routes","volume":"161","author":"Wenaweser","year":"2011","journal-title":"Am Heart J"}],"container-title":["JACC: Cardiovascular Interventions"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1936879812005560?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1936879812005560?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T17:58:22Z","timestamp":1761847102000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1936879812005560"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,8]]},"references-count":25,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2012,8]]}},"alternative-id":["S1936879812005560"],"URL":"https:\/\/doi.org\/10.1016\/j.jcin.2012.04.011","relation":{},"ISSN":["1936-8798"],"issn-type":[{"value":"1936-8798","type":"print"}],"subject":[],"published":{"date-parts":[[2012,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Impact of Paravalvular Leakage on Outcome in Patients After Transcatheter Aortic Valve Implantation","name":"articletitle","label":"Article Title"},{"value":"JACC: Cardiovascular Interventions","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcin.2012.04.011","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}