{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T16:27:51Z","timestamp":1787761671922,"version":"build-2784847793"},"reference-count":39,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2017,1,1]],"date-time":"2017-01-01T00:00:00Z","timestamp":1483228800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2018,1,23]],"date-time":"2018-01-23T00:00:00Z","timestamp":1516665600000},"content-version":"vor","delay-in-days":387,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","interventions.onlinejacc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JACC: Cardiovascular Interventions"],"published-print":{"date-parts":[[2017,1]]},"DOI":"10.1016\/j.jcin.2016.11.002","type":"journal-article","created":{"date-parts":[[2017,1,16]],"date-time":"2017-01-16T23:25:14Z","timestamp":1484609114000},"page":"168-175","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":41,"title":["Balloon Post-Dilation Following Implantation of a Self-Expanding Transcatheter Aortic Valve\u00a0Bioprosthesis"],"prefix":"10.1016","volume":"10","author":[{"given":"J. Kevin","family":"Harrison","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G. Chad","family":"Hughes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael J.","family":"Reardon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Stoler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul","family":"Grayburn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Hebeler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanping","family":"Chang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey J.","family":"Popma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jcin.2016.11.002_bib1","doi-asserted-by":"crossref","first-page":"1972","DOI":"10.1016\/j.jacc.2014.02.556","article-title":"Transcatheter aortic valve replacement using a self-expanding bioprosthesis in patients with severe aortic stenosis at extreme risk for surgery","volume":"63","author":"Popma","year":"2014","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcin.2016.11.002_bib2","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1016\/j.jcin.2012.03.007","article-title":"Structural integrity of balloon-expandable stents after transcatheter aortic valve replacement: assessment bymultidetector computed tomography","volume":"5","author":"Willson","year":"2012","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcin.2016.11.002_bib3","doi-asserted-by":"crossref","first-page":"911","DOI":"10.1016\/j.jacc.2009.04.075","article-title":"Geometry and degree of apposition of the CoreValve ReValving system with multislice computed tomography after implantation in patients with aortic stenosis","volume":"54","author":"Schultz","year":"2009","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcin.2016.11.002_bib4","doi-asserted-by":"crossref","first-page":"1364","DOI":"10.1016\/j.jcmg.2015.07.012","article-title":"Regression of paravalvular aortic regurgitation and remodeling of self-expanding transcatheter aortic valve: an observation from the CoreValve U.S. Pivotal Trial","volume":"8","author":"Oh","year":"2015","journal-title":"J\u00a0Am Coll Cardiol Img"},{"key":"10.1016\/j.jcin.2016.11.002_bib5","doi-asserted-by":"crossref","first-page":"1790","DOI":"10.1056\/NEJMoa1400590","article-title":"Transcatheter aortic-valve replacement with a self-expanding prosthesis","volume":"370","author":"Adams","year":"2014","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.jcin.2016.11.002_bib6","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/j.jacc.2015.05.017","article-title":"2-Year outcomes in patients undergoing surgical or self-expanding transcatheter aortic valve replacement","volume":"66","author":"Reardon","year":"2015","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcin.2016.11.002_bib7","doi-asserted-by":"crossref","first-page":"1327","DOI":"10.1016\/j.jacc.2015.07.042","article-title":"2-year outcomes after iliofemoral self-expanding transcatheter aortic valve replacement in patients with severe aortic stenosis deemed extreme risk for surgery","volume":"66","author":"Yakubov","year":"2015","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcin.2016.11.002_bib8","doi-asserted-by":"crossref","first-page":"1247","DOI":"10.1016\/j.jcin.2012.09.003","article-title":"Impact of post-procedural aortic regurgitation on mortality after transcatheter aortic valve implantation","volume":"5","author":"Hayashida","year":"2012","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcin.2016.11.002_bib9","doi-asserted-by":"crossref","first-page":"1125","DOI":"10.1016\/j.jacc.2012.08.1039","article-title":"Paravalvular leak after transcatheter aortic valve replacement: the new Achilles' heel? A comprehensive review of the literature","volume":"61","author":"Genereux","year":"2013","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcin.2016.11.002_bib10","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1093\/eurheartj\/ehu384","article-title":"Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards sapien valve in the PARTNER trial: characterizing patients and impact on outcomes","volume":"36","author":"Kodali","year":"2015","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jcin.2016.11.002_bib11","doi-asserted-by":"crossref","first-page":"e21","DOI":"10.1016\/j.athoracsur.2012.08.082","article-title":"Pressure curve measurements during transcatheter aortic valve implantation: a useful tool to assess the severity of aortic regurgitation","volume":"95","author":"Noble","year":"2013","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.jcin.2016.11.002_bib12","doi-asserted-by":"crossref","first-page":"1134","DOI":"10.1016\/j.jacc.2011.11.048","article-title":"Aortic regurgitation index defines severity of peri-prosthetic regurgitation and predicts outcome in patients after transcatheter aortic valve implantation","volume":"59","author":"Sinning","year":"2012","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcin.2016.11.002_bib13","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.jacc.2013.02.088","article-title":"Evaluation and management of paravalvular aortic regurgitation after transcatheter aortic valve replacement","volume":"62","author":"Sinning","year":"2013","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcin.2016.11.002_bib14","first-page":"499","article-title":"Role of balloon postdilation following trancatheter aortic valve implantation","volume":"61","author":"Nombela-Franco","year":"2013","journal-title":"Minerva Cardioangiol"},{"key":"10.1016\/j.jcin.2016.11.002_bib15","doi-asserted-by":"crossref","first-page":"790","DOI":"10.1016\/j.jcin.2014.04.004","article-title":"Balloon post-dilation after transcatheter aortic valve replacement: a solution worth trying in patients with residual aortic insufficiency","volume":"7","author":"Nietlispach","year":"2014","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcin.2016.11.002_bib16","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1161\/CIRCINTERVENTIONS.112.971614","article-title":"Efficacy and safety of postdilatation to reduce paravalvular regurgitation during balloon-expandable transcatheter aortic valve replacement","volume":"6","author":"Daneault","year":"2013","journal-title":"Circ Cardiovasc Interv"},{"key":"10.1016\/j.jcin.2016.11.002_bib17","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1016\/j.jcin.2014.02.013","article-title":"Outcomes with post-dilation following transcatheter aortic valve replacement: the PARTNER I trial (placement of aortic transcatheter valve)","volume":"7","author":"Hahn","year":"2014","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcin.2016.11.002_bib18","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1016\/j.jcin.2012.02.010","article-title":"Predictive factors, efficacy, and safety of balloon post-dilation after transcatheter aortic valve implantation with a balloon-expandable valve","volume":"5","author":"Nombela-Franco","year":"2012","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcin.2016.11.002_bib19","doi-asserted-by":"crossref","first-page":"756","DOI":"10.1002\/clc.22328","article-title":"Stroke after transcatheter aortic valve replacement: incidence, risk factors, prognosis, and preventive strategies","volume":"37","author":"Mastoris","year":"2014","journal-title":"Clin Cardiol"},{"key":"10.1016\/j.jcin.2016.11.002_bib20","doi-asserted-by":"crossref","first-page":"E609","DOI":"10.1002\/ccd.24906","article-title":"Massive aortic regurgitation following paravalvular balloon valvuloplasty of an Edwards SAPIEN valve treated by emergent CoreValve implantation: never cross a transcatheter aortic valve without a pigtail","volume":"82","author":"Noble","year":"2013","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jcin.2016.11.002_bib21","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1161\/CIRCULATIONAHA.113.002947","article-title":"Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement","volume":"128","author":"Barbanti","year":"2013","journal-title":"Circulation"},{"key":"10.1016\/j.jcin.2016.11.002_bib22","doi-asserted-by":"crossref","first-page":"912","DOI":"10.1007\/s00392-014-0729-8","article-title":"Ruptures of the device landing zone in patients undergoing transcatheter aortic valve implantation: an analysis of TAVI Karlsruhe (TAVIK) patients","volume":"103","author":"Schymik","year":"2014","journal-title":"Clin Res Cardiol"},{"key":"10.1016\/j.jcin.2016.11.002_bib23","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1093\/eurheartj\/ehq406","article-title":"Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium","volume":"32","author":"Leon","year":"2011","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jcin.2016.11.002_bib24","doi-asserted-by":"crossref","first-page":"546","DOI":"10.4244\/EIJV8I5A85","article-title":"Impact of CT-guided valve sizing on post-procedural aortic regurgitation in transcatheter aortic valve implantation","volume":"8","author":"Hayashida","year":"2012","journal-title":"EuroIntervention"},{"key":"10.1016\/j.jcin.2016.11.002_bib25","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1002\/ccd.22993","article-title":"Correlates on MSCT of paravalvular aortic regurgitation after transcatheter aortic valve implantation using the Medtronic CoreValve prosthesis","volume":"78","author":"Schultz","year":"2011","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jcin.2016.11.002_bib26","doi-asserted-by":"crossref","first-page":"1830","DOI":"10.1016\/j.amjcard.2011.02.317","article-title":"Comparison of complete versus incomplete stent frame expansion after transcatheter aortic valve implantation with Medtronic CoreValve bioprosthesis","volume":"107","author":"Jilaihawi","year":"2011","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jcin.2016.11.002_bib27","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1002\/ccd.25486","article-title":"Is postdilatation useful after implantation of the Edwards valve?","volume":"85","author":"Watanabe","year":"2015","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jcin.2016.11.002_bib28","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1093\/eurheartj\/ehp552","article-title":"Acute kidney injury following transcatheter aortic valve implantation: predictive factors, prognostic value, and comparison with surgical aortic valve replacement","volume":"31","author":"Bagur","year":"2010","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jcin.2016.11.002_bib29","doi-asserted-by":"crossref","first-page":"E112","DOI":"10.1002\/ccd.25173","article-title":"Postdilatation for treatment of perivalvular aortic regurgitation after transcatheter aortic valve implantation","volume":"83","author":"Lasa","year":"2014","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jcin.2016.11.002_bib30","doi-asserted-by":"crossref","first-page":"976","DOI":"10.1016\/j.jacc.2013.10.014","article-title":"Underexpansion and ad hoc post-dilation in selected patients undergoing balloon-expandable transcatheter aortic valve replacement","volume":"63","author":"Barbanti","year":"2014","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcin.2016.11.002_bib31","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1016\/j.ijcard.2014.10.117","article-title":"Predictors of paravalvular aortic regurgitation following self-expanding Medtronic CoreValve implantation: the role of annulus size, degree of calcification, and balloon size during pre-implantation valvuloplasty and implant depth","volume":"179","author":"Ali","year":"2015","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.jcin.2016.11.002_bib32","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1002\/ccd.23003","article-title":"Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilatation","volume":"78","author":"Takagi","year":"2011","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jcin.2016.11.002_bib33","doi-asserted-by":"crossref","first-page":"1014","DOI":"10.1016\/j.jcin.2014.03.009","article-title":"Impact of balloon post-dilation on clinical outcomes after transcatheter aortic valve replacement with the self-expanding CoreValve prosthesis","volume":"7","author":"Barbanti","year":"2014","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcin.2016.11.002_bib34","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1016\/j.jcin.2014.03.007","article-title":"Quantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement","volume":"7","author":"Khalique","year":"2014","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcin.2016.11.002_bib35","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/j.jcin.2009.11.015","article-title":"Correlation of Device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis","volume":"3","author":"John","year":"2010","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcin.2016.11.002_bib36","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1002\/ccd.25417","article-title":"Transfemoral implantation of Edwards Sapien XT aortic valve without previous valvuloplasty: role of 2D\/3D transesophageal echocardiography","volume":"84","author":"Garcia","year":"2014","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jcin.2016.11.002_bib37","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1016\/j.jtcvs.2009.07.073","article-title":"Transcatheter valve-in-valve implantation for the treatment of stentless aortic valve dysfunction","volume":"140","author":"Rodes-Cabau","year":"2010","journal-title":"J\u00a0Thorac Cardiovasc Surg"},{"key":"10.1016\/j.jcin.2016.11.002_bib38","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1002\/ccd.22168","article-title":"\u201cValve-in-valve\u201d for the treatment of paravalvular leaks following transcatheter aortic valve implantation","volume":"74","author":"Rodes-Cabau","year":"2009","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jcin.2016.11.002_bib39","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1016\/j.jcin.2011.03.015","article-title":"Feasibility of transcatheter aortic valve implantation without balloon pre-dilation: a pilot study","volume":"4","author":"Grube","year":"2011","journal-title":"J\u00a0Am Coll Cardiol Intv"}],"updated-by":[{"DOI":"10.1016\/j.jcin.2017.05.047","type":"erratum","label":"Erratum","source":"publisher","updated":{"date-parts":[[2017,6,26]],"date-time":"2017-06-26T00:00:00Z","timestamp":1498435200000}}],"container-title":["JACC: Cardiovascular Interventions"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1936879816319781?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1936879816319781?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,6,21]],"date-time":"2024-06-21T21:09:54Z","timestamp":1719004194000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1936879816319781"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1]]},"references-count":39,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2017,1]]}},"alternative-id":["S1936879816319781"],"URL":"https:\/\/doi.org\/10.1016\/j.jcin.2016.11.002","relation":{"erratum":[{"id-type":"doi","id":"10.1016\/j.jcin.2017.05.047","asserted-by":"object"}]},"ISSN":["1936-8798"],"issn-type":[{"value":"1936-8798","type":"print"}],"subject":[],"published":{"date-parts":[[2017,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Balloon Post-Dilation Following Implantation of a Self-Expanding Transcatheter Aortic Valve\u00a0Bioprosthesis","name":"articletitle","label":"Article Title"},{"value":"JACC: Cardiovascular Interventions","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcin.2016.11.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 by the American College of Cardiology Foundation. Published by Elsevier.","name":"copyright","label":"Copyright"}]}}