{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T18:33:56Z","timestamp":1786991636580,"version":"build-2736575974"},"reference-count":26,"publisher":"Elsevier BV","issue":"10","license":[{"start":{"date-parts":[[2019,5,1]],"date-time":"2019-05-01T00:00:00Z","timestamp":1556668800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,5,1]],"date-time":"2019-05-01T00:00:00Z","timestamp":1556668800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2020,5,28]],"date-time":"2020-05-28T00:00:00Z","timestamp":1590624000000},"content-version":"vor","delay-in-days":393,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100011949","name":"Abbott Vascular","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100011949","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002996","name":"Hartstichting","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100002996","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jacc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JACC: Cardiovascular Interventions"],"published-print":{"date-parts":[[2019,5]]},"DOI":"10.1016\/j.jcin.2019.03.004","type":"journal-article","created":{"date-parts":[[2019,4,24]],"date-time":"2019-04-24T15:54:24Z","timestamp":1556121264000},"page":"967-979","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":8,"title":["Myocardial Blood Flow and Coronary Flow Reserve During 3 Years Following Bioresorbable Vascular Scaffold Versus Metallic Drug-Eluting Stent Implantation"],"prefix":"10.1016","volume":"12","author":[{"given":"Wijnand J.","family":"Stuijfzand","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan P.","family":"Schumacher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roel S.","family":"Driessen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adriaan A.","family":"Lammertsma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amber L.","family":"Bakker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mischa T.","family":"Rijnierse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Albert C.","family":"van Rossum","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter M.","family":"van de Ven","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Nap","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yolande","family":"Appelman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Niels","family":"van Royen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maarten A.","family":"van Leeuwen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jorrit S.","family":"Lemkes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pieter G.","family":"Raijmakers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul","family":"Knaapen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jcin.2019.03.004_bib1","first-page":"301","article-title":"The ABSORB bioresorbable vascular scaffold: an evolution or revolution in interventional cardiology?","volume":"53","author":"Gogas","year":"2012","journal-title":"Hellenic J Cardiol"},{"key":"10.1016\/j.jcin.2019.03.004_bib2","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1093\/eurheartj\/ehr384","article-title":"From metallic cages to transient bioresorbable scaffolds: change in paradigm of coronary revascularization in the upcoming decade?","volume":"33","author":"Serruys","year":"2012","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jcin.2019.03.004_bib3","doi-asserted-by":"crossref","first-page":"1325","DOI":"10.1093\/eurheartj\/ehr466","volume":"33","author":"Brugaletta","year":"2012","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jcin.2019.03.004_bib4","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1161\/CIRCULATIONAHA.114.011939","article-title":"Global coronary flow reserve is associated with adverse cardiovascular events independently of luminal angiographic severity and modifies the effect of early revascularization","volume":"131","author":"Taqueti","year":"2015","journal-title":"Circulation"},{"key":"10.1016\/j.jcin.2019.03.004_bib5","doi-asserted-by":"crossref","first-page":"2215","DOI":"10.1161\/CIRCULATIONAHA.111.050427","article-title":"Improved cardiac risk assessment with noninvasive measures of coronary flow reserve","volume":"124","author":"Murthy","year":"2011","journal-title":"Circulation"},{"key":"10.1016\/j.jcin.2019.03.004_bib6","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1111\/j.1475-097X.2008.00794.x","article-title":"Assessment of coronary blood flow and the reactivity of the microcirculation non-invasively with transthoracic echocardiography","volume":"28","author":"Kiviniemi","year":"2008","journal-title":"Clin Physiol Funct Imaging"},{"key":"10.1016\/j.jcin.2019.03.004_bib7","doi-asserted-by":"crossref","first-page":"e584","DOI":"10.4244\/EIJV12I5A98","article-title":"Evaluation of myocardial blood flow and coronary flow reserve after implantation of a bioresorbable vascular scaffold versus metal drug-eluting stent: an interim one-month analysis of the VANISH trial","volume":"12","author":"Stuijfzand","year":"2016","journal-title":"EuroIntervention"},{"key":"10.1016\/j.jcin.2019.03.004_bib8","doi-asserted-by":"crossref","first-page":"1058","DOI":"10.1016\/j.jacc.2011.09.079","article-title":"Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: a report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation","volume":"59","author":"Tearney","year":"2012","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcin.2019.03.004_bib9","doi-asserted-by":"crossref","first-page":"1498","DOI":"10.4244\/EIJY15M10_03","article-title":"Comparative analysis method of permanent metallic stents (XIENCE) and bioresorbable poly-L-lactic (PLLA) scaffolds (Absorb) on optical coherence tomography at baseline and follow-up","volume":"12","author":"Nakatani","year":"2016","journal-title":"EuroIntervention"},{"key":"10.1016\/j.jcin.2019.03.004_bib10","doi-asserted-by":"crossref","first-page":"1231","DOI":"10.1016\/j.jcin.2016.03.027","article-title":"The impact of post-procedural asymmetry, expansion, and eccentricity of bioresorbable everolimus-eluting scaffold and metallic everolimus-eluting stent on clinical outcomes in the ABSORB II trial","volume":"9","author":"Suwannasom","year":"2016","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcin.2019.03.004_bib11","doi-asserted-by":"crossref","first-page":"2288","DOI":"10.1161\/CIRCULATIONAHA.109.921528","volume":"122","author":"Onuma","year":"2010","journal-title":"Circulation"},{"key":"10.1016\/j.jcin.2019.03.004_bib12","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1093\/ehjci\/jex035","article-title":"Randomized comparison of sirolimus eluting, and biolimus eluting bioresorbable polymer stents: the SORT-OUT VII optical coherence tomography study","volume":"19","author":"Andreasen","year":"2018","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"10.1016\/j.jcin.2019.03.004_bib13","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1007\/s00259-011-1956-0","article-title":"Coronary risk factors and myocardial blood flow in patients evaluated for coronary artery disease: a quantitative [15O]H2O PET\/CT study","volume":"39","author":"Danad","year":"2012","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"10.1016\/j.jcin.2019.03.004_bib14","first-page":"419","article-title":"PET-measured responses of MBF to cold pressor testing correlate with indices of coronary vasomotion on quantitative coronary angiography","volume":"45","author":"Schindler","year":"2004","journal-title":"J\u00a0Nucl Med"},{"key":"10.1016\/j.jcin.2019.03.004_bib15","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1007\/s00259-011-1730-3","article-title":"Automatic generation of absolute myocardial blood flow images using [15O]H2O and a clinical PET\/CT scanner","volume":"38","author":"Harms","year":"2011","journal-title":"Eur J Nucl Med"},{"key":"10.1016\/j.jcin.2019.03.004_bib16","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1161\/hc0402.102975","article-title":"Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association","volume":"105","author":"Cerqueira","year":"2002","journal-title":"Circulation"},{"key":"10.1016\/j.jcin.2019.03.004_bib17","doi-asserted-by":"crossref","first-page":"897","DOI":"10.1016\/S0140-6736(09)60325-1","article-title":"A\u00a0bioabsorbable everolimus-eluting coronary stent system (ABSORB):2-year outcomes and results from multiple imaging methods","volume":"373","author":"Serruys","year":"2009","journal-title":"Lancet"},{"key":"10.1016\/j.jcin.2019.03.004_bib18","doi-asserted-by":"crossref","first-page":"728","DOI":"10.1016\/j.jcin.2015.12.018","volume":"9","author":"Gogas","year":"2016","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcin.2019.03.004_bib19","doi-asserted-by":"crossref","first-page":"2479","DOI":"10.1016\/S0140-6736(16)32050-5","article-title":"Comparison of an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent for the treatment of coronary artery stenosis (ABSORB II): a 3 year, randomised, controlled, single-blind, multicentre clinical trial","volume":"388","author":"Serruys","year":"2016","journal-title":"Lancet"},{"key":"10.1016\/j.jcin.2019.03.004_bib20","doi-asserted-by":"crossref","first-page":"786","DOI":"10.1016\/j.jcin.2016.12.020","article-title":"Vasomotor response to nitroglycerine over 5 years follow-up after everolimus-eluting bioresorbable scaffold implantation","volume":"10","author":"Dudek","year":"2017","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcin.2019.03.004_bib21","first-page":"1420","article-title":"Repeatability of cold pressor test-induced flow increase assessed with H(2)(15)O and PET","volume":"47","author":"Siegrist","year":"2006","journal-title":"J\u00a0Nucl Med"},{"key":"10.1016\/j.jcin.2019.03.004_bib22","doi-asserted-by":"crossref","first-page":"1559","DOI":"10.1016\/j.jcin.2018.04.026","article-title":"Long-term coronary functional assessment of the infarct-related artery treated with everolimus-eluting bioresorbable scaffolds or everolimus-eluting metallic stents: insights of the TROFI II trial","volume":"11","author":"Gomez-Lara","year":"2018","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcin.2019.03.004_bib23","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/j.jcmg.2011.09.020","article-title":"Is discordance of coronary flow reserve and fractional flow reserve due to methodology or clinically relevant coronary pathophysiology?","volume":"5","author":"Johnson","year":"2012","journal-title":"J\u00a0Am Coll Cardiol Img"},{"key":"10.1016\/j.jcin.2019.03.004_bib24","doi-asserted-by":"crossref","first-page":"e998","DOI":"10.4244\/EIJV12I8A163","article-title":"Is quantitative coronary angiography reliable in assessing the lumen gain after treatment with the everolimus-eluting bioresorbable polylactide scaffold?","volume":"12","author":"Sotomi","year":"2016","journal-title":"EuroIntervention"},{"key":"10.1016\/j.jcin.2019.03.004_bib25","doi-asserted-by":"crossref","first-page":"2298","DOI":"10.1016\/j.jacc.2015.09.054","article-title":"Bioresorbable vascular scaffolds versus metallic stents in patients with coronary artery disease: ABSORB\u00a0China trial","volume":"66","author":"Gao","year":"2015","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcin.2019.03.004_bib26","doi-asserted-by":"crossref","first-page":"1313","DOI":"10.1016\/j.jcin.2018.01.274","article-title":"Angiography alone versus angiography plus optical coherence tomography to guide percutaneous coronary intervention: outcomes from the Pan-London PCI Cohort","volume":"11","author":"Jones","year":"2018","journal-title":"J\u00a0Am Coll Cardiol Intv"}],"container-title":["JACC: Cardiovascular Interventions"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1936879819306594?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1936879819306594?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T18:09:01Z","timestamp":1761847741000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1936879819306594"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5]]},"references-count":26,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2019,5]]}},"alternative-id":["S1936879819306594"],"URL":"https:\/\/doi.org\/10.1016\/j.jcin.2019.03.004","relation":{},"ISSN":["1936-8798"],"issn-type":[{"value":"1936-8798","type":"print"}],"subject":[],"published":{"date-parts":[[2019,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Myocardial Blood Flow and Coronary Flow Reserve During 3 Years Following Bioresorbable Vascular Scaffold Versus Metallic Drug-Eluting Stent Implantation","name":"articletitle","label":"Article Title"},{"value":"JACC: Cardiovascular Interventions","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcin.2019.03.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 by the American College of Cardiology Foundation. Published by Elsevier.","name":"copyright","label":"Copyright"}]}}