{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,16]],"date-time":"2025-09-16T19:21:27Z","timestamp":1758050487983,"version":"3.44.0"},"reference-count":20,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2013,8,1]],"date-time":"2013-08-01T00:00:00Z","timestamp":1375315200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2013,8,1]],"date-time":"2013-08-01T00:00:00Z","timestamp":1375315200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["canadianjournalofophthalmology.ca","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Canadian Journal of Ophthalmology"],"published-print":{"date-parts":[[2013,8]]},"DOI":"10.1016\/j.jcjo.2013.02.002","type":"journal-article","created":{"date-parts":[[2013,10,3]],"date-time":"2013-10-03T22:02:14Z","timestamp":1380837734000},"page":"259-264","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":5,"title":["Effect of intraoperative manipulation during iris-claw phakic IOL implantation on endothelium"],"prefix":"10.1016","volume":"48","author":[{"given":"Kyung-Sun","family":"Na","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sohee","family":"Jeon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Choun-Ki","family":"Joo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jcjo.2013.02.002_bib1","doi-asserted-by":"crossref","first-page":"310","DOI":"10.3928\/1081-597X-20000501-03","article-title":"Long-term results of correction of high myopia with an iris claw phakic intraocular lens","volume":"16","author":"Landesz","year":"2000","journal-title":"J Refract Surg"},{"key":"10.1016\/j.jcjo.2013.02.002_bib2","doi-asserted-by":"crossref","first-page":"634","DOI":"10.3928\/1081-597X-20011101-01","article-title":"Iris-claw phakic intraocular lens for high myopia","volume":"17","author":"Landesz","year":"2001","journal-title":"J Refract Surg"},{"key":"10.1016\/j.jcjo.2013.02.002_bib3","doi-asserted-by":"crossref","first-page":"1002","DOI":"10.1016\/j.ophtha.2007.08.022","article-title":"Five-year follow-up of 399 phakic Artisan-Verisyse implantation for myopia, hyperopia, and\/or astigmatism","volume":"115","author":"G\u00fcell","year":"2008","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jcjo.2013.02.002_bib4","doi-asserted-by":"crossref","first-page":"955","DOI":"10.1016\/S0161-6420(02)00964-8","article-title":"Comparison of iris-fixed Artisan lens implantation with excimer laser in situ keratomileusis in correcting myopia between -9.00 and -19.50 diopters: a randomized study","volume":"109","author":"El Danasoury","year":"2002","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jcjo.2013.02.002_bib5","doi-asserted-by":"crossref","first-page":"1163","DOI":"10.1016\/S0886-3350(00)00545-9","article-title":"Multicenter study of the Artisan phakic intraocular lens","volume":"26","author":"Budo","year":"2000","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.jcjo.2013.02.002_bib6","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1016\/j.ophtha.2007.08.039","article-title":"Three-year results of Artisan\/Verisyse phakic intraocular lens implantation. Results of the United States Food and Drug Administration clinical trial","volume":"115","author":"Stulting","year":"2008","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jcjo.2013.02.002_bib7","doi-asserted-by":"crossref","first-page":"1391","DOI":"10.1016\/S0161-6420(03)00405-6","article-title":"Three-year follow-up of the Artisan phakic intraocular lens for hypermetropia","volume":"110","author":"Saxena","year":"2003","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jcjo.2013.02.002_bib8","doi-asserted-by":"crossref","first-page":"784","DOI":"10.1016\/j.jcrs.2007.01.037","article-title":"Long-term endothelial changes in phakic eyes after Artisan intraocular lens implantation to correct myopia: five-year study","volume":"33","author":"Benedetti","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.jcjo.2013.02.002_bib9","doi-asserted-by":"crossref","first-page":"608","DOI":"10.1016\/j.ophtha.2007.05.036","article-title":"Long-term follow-up of endothelial cell change after Artisan phakic intraocular lens implantation","volume":"115","author":"Saxena","year":"2008","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jcjo.2013.02.002_bib10","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.1016\/S0886-3350(98)80096-5","article-title":"Endothelial study of iris-claw phakic lens: four year follow-up","volume":"24","author":"Menezo","year":"1998","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.jcjo.2013.02.002_bib11","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1016\/j.jcrs.2007.10.030","article-title":"Corneal endothelial decompensation after iris-claw phakic intraocular lens implantation","volume":"34","author":"Kim","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"10.1016\/j.jcjo.2013.02.002_bib12","doi-asserted-by":"crossref","first-page":"172","DOI":"10.3928\/1081-597X-20070201-09","article-title":"Endothelial cell loss after toric iris-fixated phakic intraocular lens implantation: three-year follow-up","volume":"23","author":"Tehrani","year":"2007","journal-title":"J Refract Surg"},{"key":"10.1016\/j.jcjo.2013.02.002_bib13","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/S0955-3681(89)80082-6","article-title":"Some optical aspects of implantation of an IOL in a myopic eye","volume":"1","author":"van der Heijde","year":"1989","journal-title":"Eur J Implant Refract Surg"},{"key":"10.1016\/j.jcjo.2013.02.002_bib14","first-page":"779","article-title":"Central corneal endothelial cell changes over a ten-year period","volume":"38","author":"Bourne","year":"1997","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.jcjo.2013.02.002_bib15","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1016\/j.ophtha.2003.05.025","article-title":"Initial results of endothelial cell counts after Artisan lens for phakic eyes: an evaluation of the United States Food and Drug Administration Ophtec Study","volume":"111","author":"Pop","year":"2004","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jcjo.2013.02.002_bib16","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1016\/S0014-4835(03)00209-4","article-title":"Prospects for endothelial transplantation","volume":"78","author":"Engelmann","year":"2004","journal-title":"Exp Eye Res"},{"key":"10.1016\/j.jcjo.2013.02.002_bib17","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1016\/j.exer.2005.06.012","article-title":"Cell cycle status in human corneal endothelium","volume":"81","author":"Joyce","year":"2005","journal-title":"Exp Eye Res"},{"key":"10.1016\/j.jcjo.2013.02.002_bib18","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1001\/archopht.126.6.775","article-title":"Prospective long-term evaluation of the efficacy, safety, and stability of the phakic intraocular lens for high myopia","volume":"126","author":"Silva","year":"2008","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.jcjo.2013.02.002_bib19","doi-asserted-by":"crossref","first-page":"546","DOI":"10.3928\/1081597X-20080501-15","article-title":"Long-term endothelial cell loss after traumatic dislocation and repositioning of Artisan phakic IOL","volume":"24","author":"de Sanctis","year":"2008","journal-title":"J Refract Surg"},{"key":"10.1016\/j.jcjo.2013.02.002_bib20","doi-asserted-by":"crossref","first-page":"102","DOI":"10.3928\/1081-597X-20060101-19","article-title":"Traumatic dislocation and successful re-enclavation of an Artisan phakic IOL with analysis of the endothelium","volume":"22","author":"Ioannidis","year":"2006","journal-title":"J Refract Surg"}],"container-title":["Canadian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0008418213000859?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0008418213000859?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,13]],"date-time":"2025-09-13T20:02:59Z","timestamp":1757793779000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0008418213000859"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,8]]},"references-count":20,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2013,8]]}},"alternative-id":["S0008418213000859"],"URL":"https:\/\/doi.org\/10.1016\/j.jcjo.2013.02.002","relation":{},"ISSN":["0008-4182"],"issn-type":[{"type":"print","value":"0008-4182"}],"subject":[],"published":{"date-parts":[[2013,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Effect of intraoperative manipulation during iris-claw phakic IOL implantation on endothelium","name":"articletitle","label":"Article Title"},{"value":"Canadian Journal of Ophthalmology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcjo.2013.02.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2013 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}