{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T05:11:22Z","timestamp":1790140282913,"version":"4.0.1"},"reference-count":23,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2016,2,1]],"date-time":"2016-02-01T00:00:00Z","timestamp":1454284800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2016,2,1]],"date-time":"2016-02-01T00:00:00Z","timestamp":1454284800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["canadianjournalofophthalmology.ca","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Canadian Journal of Ophthalmology"],"published-print":{"date-parts":[[2016,2]]},"DOI":"10.1016\/j.jcjo.2015.09.014","type":"journal-article","created":{"date-parts":[[2016,2,13]],"date-time":"2016-02-13T13:13:15Z","timestamp":1455369195000},"page":"19-24","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":27,"title":["Comparison of intraocular pressure post penetrating keratoplasty vs Descemet\u2019s stripping endothelial keratoplasty"],"prefix":"10.1016","volume":"51","author":[{"given":"Rahul A.","family":"Sharma","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lulu LCD","family":"Bursztyn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth","family":"Golesic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rookaya","family":"Mather","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David P.","family":"Tingey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jcjo.2015.09.014_bib1","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1007\/BF01949227","article-title":"A successful total corneal transplant","volume":"64","author":"Zirm","year":"1906","journal-title":"Graefes Arch Ophthalmol"},{"key":"10.1016\/j.jcjo.2015.09.014_bib2","doi-asserted-by":"crossref","first-page":"1972","DOI":"10.1038\/eye.2008.377","article-title":"Management of patients with combined glaucoma and corneal transplant surgery","volume":"23","author":"Banitt","year":"2009","journal-title":"Eye"},{"key":"10.1016\/j.jcjo.2015.09.014_bib3","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1097\/ICU.0b013e3283360b95","article-title":"Descemet\u2019s stripping with automated endothelial keratoplasty and glaucoma","volume":"21","author":"Banitt","year":"2010","journal-title":"Curr Opin Ophthalmol"},{"key":"10.1016\/j.jcjo.2015.09.014_bib4","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1097\/ICO.0b013e3181c11bf3","article-title":"Descemet stripping automated endothelial keratoplasty in eyes with previous trabeculectomy and tube shunt procedures: intraoperative and early postoperative complications","volume":"29","author":"Phillips","year":"2010","journal-title":"Cornea"},{"key":"10.1016\/j.jcjo.2015.09.014_bib5","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1097\/ICU.0b013e3281a4775b","article-title":"Descemet\u2019s stripping endothelial keratoplasty","volume":"18","author":"Price","year":"2007","journal-title":"Curr Opin Ophthalmol"},{"key":"10.1016\/j.jcjo.2015.09.014_bib6","doi-asserted-by":"crossref","first-page":"339","DOI":"10.3928\/1081-597X-20050701-07","article-title":"Descemet\u2019s stripping with endothelial keratoplasty in 50 eyes: a refractive neutral corneal transplant","volume":"21","author":"Price","year":"2005","journal-title":"J Refract Surg"},{"key":"10.1016\/j.jcjo.2015.09.014_bib7","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/j.oftal.2010.09.003","article-title":"Comparison of Goldmann tonometry, pneumotonometry and the effect of central corneal thickness","volume":"85","author":"Molina","year":"2010","journal-title":"Arch Soc Esp Oftalmol"},{"key":"10.1016\/j.jcjo.2015.09.014_bib8","series-title":"Eye Banking Statistical Report","year":"2007"},{"key":"10.1016\/j.jcjo.2015.09.014_bib9","doi-asserted-by":"crossref","unstructured":"Boimer C, Lee K, Sharpen L, et al. Evolving surgical techniques of and indications for corneal transplantation in Ontario from 2000 to 2009. Can J Ophthalmol. 2011;46: 360-366.","DOI":"10.1016\/j.jcjo.2011.06.015"},{"key":"10.1016\/j.jcjo.2015.09.014_bib10","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1097\/ICO.0b013e31819c4e2c","article-title":"Early results of Descemet-stripping and automated endothelial keratoplasty (DSAEK) in patients with glaucoma drainage devices","volume":"28","author":"Riaz","year":"2009","journal-title":"Cornea"},{"key":"10.1016\/j.jcjo.2015.09.014_bib11","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1097\/IJG.0b013e3181af3202","article-title":"Safety of DSAEK in patients with previous glaucoma filtering surgery","volume":"19","author":"Esquenazi","year":"2010","journal-title":"J Glaucoma"},{"key":"10.1016\/j.jcjo.2015.09.014_bib12","doi-asserted-by":"crossref","first-page":"1972","DOI":"10.1038\/eye.2008.377","article-title":"Management of patients with combined glaucoma and corneal transplant surgery","volume":"23","author":"Banitt","year":"2009","journal-title":"Eye (Lond)"},{"key":"10.1016\/j.jcjo.2015.09.014_bib13","doi-asserted-by":"crossref","first-page":"1644","DOI":"10.1016\/j.ophtha.2009.05.034","article-title":"Visual acuity and IOP after Descemet\u2019s stripping endothelial keratoplasty in eyes with and without preexisting glaucoma","volume":"116","author":"Vajaranant","year":"2009","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jcjo.2015.09.014_bib14","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1007\/s00417-009-1199-y","article-title":"Intraocular pressure changes following Descemet\u2019s stripping with endothelial keratoplasty","volume":"248","author":"Espana","year":"2010","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"10.1016\/j.jcjo.2015.09.014_bib15","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1097\/ICO.0000000000000342","article-title":"Changes in intraocular pressure after descemet stripping automated endothelial keratoplasty: a retrospective analysis","volume":"34","author":"Muller","year":"2015","journal-title":"Cornea"},{"key":"10.1016\/j.jcjo.2015.09.014_bib16","doi-asserted-by":"crossref","first-page":"1083","DOI":"10.1097\/ICO.0b013e31828ea02a","article-title":"Long-term outcomes of penetrating keratoplasty and descemet stripping endothelial keratoplasty for Fuchs endothelial dystrophy: fellow eye comparison","volume":"32","author":"Kosker","year":"2013","journal-title":"Cornea"},{"key":"10.1016\/j.jcjo.2015.09.014_bib17","doi-asserted-by":"crossref","first-page":"1091","DOI":"10.1016\/j.ajo.2011.12.014","article-title":"Outcomes of trabeculectomy after descemet stripping automated endothelial keratoplasty: a comparison with penetrating keratoplasty","volume":"153","author":"Boey","year":"2012","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.jcjo.2015.09.014_bib18","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1007\/s10792-011-9512-2","article-title":"Glaucoma therapy escalation in eyes with pseudophakic corneal edema after penetrating keratoplasty and descemet\u2019s stripping automated endothelial keratoplasty","volume":"32","author":"Wandling","year":"2012","journal-title":"Int Ophthalmol"},{"key":"10.1016\/j.jcjo.2015.09.014_bib19","article-title":"Elevated intraocular pressure in patients undergoing penetrating keratoplasty and Descemet stripping endothelial keratoplasty","author":"Sandhu","year":"2015","journal-title":"J Glaucoma"},{"key":"10.1016\/j.jcjo.2015.09.014_bib20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/0039-6257(93)90053-A","article-title":"Sources of error with use of Goldmann-type tonometers","volume":"38","author":"Whiteacre","year":"1993","journal-title":"Surv Ophthalmol"},{"key":"10.1016\/j.jcjo.2015.09.014_bib21","doi-asserted-by":"crossref","first-page":"780","DOI":"10.1016\/j.ajo.2008.01.010","article-title":"Intraocular pressure measurements following Descemet stripping endothelial keratoplasty","volume":"145","author":"Vajaranant","year":"2008","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.jcjo.2015.09.014_bib22","doi-asserted-by":"crossref","first-page":"1936","DOI":"10.1016\/j.ophtha.2006.05.034","article-title":"Descemet\u2019s stripping with endothelial keratoplasty: comparative outcomes with microkeratome-dissected and manually dissected donor tissue","volume":"113","author":"Price","year":"2006","journal-title":"Ophthalmology"},{"key":"10.1016\/j.jcjo.2015.09.014_bib23","doi-asserted-by":"crossref","first-page":"500","DOI":"10.1001\/archopht.1963.00960050502012","article-title":"Corticosteroids and intraocular pressure","volume":"70","author":"Becker","year":"1963","journal-title":"Arch Ophthalmol"}],"container-title":["Canadian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0008418215004081?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0008418215004081?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,13]],"date-time":"2025-09-13T20:04:41Z","timestamp":1757793881000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0008418215004081"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,2]]},"references-count":23,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2016,2]]}},"alternative-id":["S0008418215004081"],"URL":"https:\/\/doi.org\/10.1016\/j.jcjo.2015.09.014","relation":{},"ISSN":["0008-4182"],"issn-type":[{"value":"0008-4182","type":"print"}],"subject":[],"published":{"date-parts":[[2016,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of intraocular pressure post penetrating keratoplasty vs Descemet\u2019s stripping endothelial keratoplasty","name":"articletitle","label":"Article Title"},{"value":"Canadian Journal of Ophthalmology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcjo.2015.09.014","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}