{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T01:54:21Z","timestamp":1767146061734,"version":"build-2238731810"},"reference-count":22,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2005,8,1]],"date-time":"2005-08-01T00:00:00Z","timestamp":1122854400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2005,8,1]],"date-time":"2005-08-01T00:00:00Z","timestamp":1122854400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Clinical Anesthesia"],"published-print":{"date-parts":[[2005,8]]},"DOI":"10.1016\/j.jclinane.2004.08.007","type":"journal-article","created":{"date-parts":[[2005,8,14]],"date-time":"2005-08-14T07:35:40Z","timestamp":1124004940000},"page":"334-338","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["The usefulness of the modified laryngoscopic blade for training novice laryngoscopists"],"prefix":"10.1016","volume":"17","author":[{"given":"Jaemin","family":"Lee","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Byung Sam","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hae Wone","family":"Chang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoonki","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jclinane.2004.08.007_bib1","first-page":"163","article-title":"Oral complications associated with endotracheal general anesthesia","volume":"28","author":"Chen","year":"1990","journal-title":"Ma Zui Xue Za Zhi"},{"key":"10.1016\/j.jclinane.2004.08.007_bib2","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1097\/00004311-198902720-00010","article-title":"Anesthesia-induced dental injury","volume":"27","author":"Rosenberg","year":"1989","journal-title":"Int Anesthesiol Clin"},{"key":"10.1016\/j.jclinane.2004.08.007_bib3","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1177\/0310057X0002800202","article-title":"Dental trauma associated with anaesthesia","volume":"28","author":"Owen","year":"2000","journal-title":"Anaesth Intensive Care"},{"key":"10.1016\/j.jclinane.2004.08.007_bib4","doi-asserted-by":"crossref","first-page":"1302","DOI":"10.1097\/00000542-199905000-00013","article-title":"Perianesthetic dental injuries; frequency, outcomes, and risk factors","volume":"90","author":"Warner","year":"1999","journal-title":"Anesthesiology"},{"key":"10.1016\/j.jclinane.2004.08.007_bib5","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1111\/j.1365-2044.1987.tb03110.x","article-title":"Modification of Macintosh laryngoscope for difficult intubation","volume":"42","author":"Callander","year":"1987","journal-title":"Anaesthesia"},{"key":"10.1016\/j.jclinane.2004.08.007_bib6","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1093\/bja\/61.2.211","article-title":"Predicting difficult intubation","volume":"61","author":"Wilson","year":"1988","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.jclinane.2004.08.007_bib7","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1007\/BF03018781","article-title":"The Callander laryngoscope blade modification is associated with a decreased risk of dental contact","volume":"51","author":"Lee","year":"2004","journal-title":"Can J Anaesth"},{"key":"10.1016\/j.jclinane.2004.08.007_bib8","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1213\/00000539-199410000-00004","article-title":"Determination of the distance between the laryngoscope blade and the upper incisors during direct laryngoscopy: comparisons of a curved, an angulated straight, and two straight blades","volume":"79","author":"Watanabe","year":"1994","journal-title":"Anesth Analg"},{"key":"10.1016\/j.jclinane.2004.08.007_bib9","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1111\/j.1365-2044.1984.tb08932.x","article-title":"Difficult tracheal intubation in obstetrics","volume":"39","author":"Cormack","year":"1984","journal-title":"Anaesthesia"},{"key":"10.1016\/j.jclinane.2004.08.007_bib10","doi-asserted-by":"crossref","first-page":"480","DOI":"10.14219\/jada.archive.1986.0035","article-title":"Dental complications during and after tracheal intubation","volume":"112","author":"Lockhart","year":"1986","journal-title":"J Am Dent Assoc"},{"key":"10.1016\/j.jclinane.2004.08.007_bib11","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1177\/0310057X8701500304","article-title":"Dental damage during anaesthesia and surgery","volume":"15","author":"Burton","year":"1987","journal-title":"Anaesth Intensive Care"},{"key":"10.1016\/j.jclinane.2004.08.007_bib12","doi-asserted-by":"crossref","first-page":"653","DOI":"10.1213\/00000539-199803000-00037","article-title":"Learning manual skills in anesthesiology: is there a recommended number of cases for anesthetic procedures?","volume":"86","author":"Konrad","year":"1998","journal-title":"Anesth Analg"},{"key":"10.1016\/j.jclinane.2004.08.007_bib13","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1213\/00000539-195807000-00017","article-title":"Improved laryngoscope blade designed for ease of manipulation and reduction of trauma","volume":"37","author":"Bizzarri","year":"1958","journal-title":"Anesth Analg"},{"key":"10.1016\/j.jclinane.2004.08.007_bib14","doi-asserted-by":"crossref","first-page":"662","DOI":"10.1111\/j.1365-2044.1997.134-az0133.x","article-title":"Reshaping the Macintosh blade using biomechanical modeling. A prospective comparative study in patients","volume":"52","author":"Bucx","year":"1997","journal-title":"Anaesthesia"},{"key":"10.1016\/j.jclinane.2004.08.007_bib15","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1097\/00000542-198807000-00024","article-title":"An angulated laryngoscope for routine and difficult tracheal intubation","volume":"69","author":"Bellhouse","year":"1988","journal-title":"Anesthesiology"},{"key":"10.1016\/j.jclinane.2004.08.007_bib16","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1111\/j.1365-2044.1993.tb07075.x","article-title":"The levering laryngoscope","volume":"48","author":"McCoy","year":"1993","journal-title":"Anaesthesia"},{"key":"10.1016\/j.jclinane.2004.08.007_bib17","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1097\/00000542-198108000-00020","article-title":"A modified laryngoscope blade for dental protection","volume":"55","author":"Lisman","year":"1981","journal-title":"Anesthesiology"},{"key":"10.1016\/j.jclinane.2004.08.007_bib18","first-page":"47","article-title":"Laryngoscope modification to avoid perioral trauma due to laryngoscopy","volume":"29","author":"Nique","year":"1982","journal-title":"Anesth Prog"},{"key":"10.1016\/j.jclinane.2004.08.007_bib19","doi-asserted-by":"crossref","first-page":"810","DOI":"10.1097\/00000542-198911000-00041","article-title":"Protecting teeth during endotracheal intubation","volume":"71","author":"Haddy","year":"1989","journal-title":"Anesthesiology"},{"key":"10.1016\/j.jclinane.2004.08.007_bib20","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1213\/00000539-199701000-00054","article-title":"Prevention of dental trauma during endotracheal intubation","volume":"84","author":"Ghabash","year":"1997","journal-title":"Anesth Analg"},{"key":"10.1016\/j.jclinane.2004.08.007_bib21","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1111\/j.1399-6576.1988.tb02733.x","article-title":"Difficulties with tooth protectors in endotracheal intubation","volume":"32","author":"Aromaa","year":"1988","journal-title":"Acta Anaesthesiol Scand"},{"key":"10.1016\/j.jclinane.2004.08.007_bib22","first-page":"1257","article-title":"Determination of the distance between the upper incisors and the laryngoscope blade during laryngoscopy: comparisons of the McCoy, the Macintosh, the Miller, and the Belscope blades","volume":"47","author":"Bito","year":"1998","journal-title":"Masui"}],"updated-by":[{"DOI":"10.1016\/j.jclinane.2005.10.001","type":"erratum","label":"Erratum","source":"publisher","updated":{"date-parts":[[2005,11,1]],"date-time":"2005-11-01T00:00:00Z","timestamp":1130803200000}}],"container-title":["Journal of Clinical Anesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0952818005000814?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0952818005000814?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T08:53:15Z","timestamp":1760604795000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0952818005000814"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,8]]},"references-count":22,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2005,8]]}},"alternative-id":["S0952818005000814"],"URL":"https:\/\/doi.org\/10.1016\/j.jclinane.2004.08.007","relation":{},"ISSN":["0952-8180"],"issn-type":[{"value":"0952-8180","type":"print"}],"subject":[],"published":{"date-parts":[[2005,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The usefulness of the modified laryngoscopic blade for training novice laryngoscopists","name":"articletitle","label":"Article Title"},{"value":"Journal of Clinical Anesthesia","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jclinane.2004.08.007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2005 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}