{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T16:02:49Z","timestamp":1784822569752,"version":"3.55.0"},"reference-count":19,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2008,6,1]],"date-time":"2008-06-01T00:00:00Z","timestamp":1212278400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2008,6,1]],"date-time":"2008-06-01T00:00:00Z","timestamp":1212278400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Clinical Anesthesia"],"published-print":{"date-parts":[[2008,6]]},"DOI":"10.1016\/j.jclinane.2007.11.002","type":"journal-article","created":{"date-parts":[[2008,7,9]],"date-time":"2008-07-09T10:13:14Z","timestamp":1215598394000},"page":"247-252","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":87,"title":["Can ultrasound be useful for predicting the size of a left double-lumen bronchial tube? Tracheal width as measured by ultrasonography versus computed tomography"],"prefix":"10.1016","volume":"20","author":[{"given":"Alan","family":"\u0160usti\u0107","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Damir","family":"Mileti\u0107","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alen","family":"Proti\u0107","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aldo","family":"Ivan\u010di\u0107","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tedi","family":"Cicvari\u0107","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jclinane.2007.11.002_bib1","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1016\/S1053-0770(03)00046-6","article-title":"Left double-lumen tubes: clinical experience with 1,170 patients","volume":"17","author":"Brodsky","year":"2003","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.jclinane.2007.11.002_bib2","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1097\/00001503-200202000-00011","article-title":"Methods of lung separation","volume":"15","author":"Cohen","year":"2002","journal-title":"Curr Opin Anaesthesiol"},{"key":"10.1016\/j.jclinane.2007.11.002_bib3","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1097\/00000542-198711000-00018","article-title":"Margin of safety in positioning modern double-lumen endotracheal tube","volume":"67","author":"Benumof","year":"1987","journal-title":"Anesthesiology"},{"key":"10.1016\/j.jclinane.2007.11.002_bib4","doi-asserted-by":"crossref","first-page":"1243","DOI":"10.1213\/01.ANE.0000173750.04255.F1","article-title":"Tracheal perforation from double-lumen tubes: size may be important [Letter]","volume":"101","author":"Lohser","year":"2005","journal-title":"Anaesth Analg"},{"key":"10.1016\/j.jclinane.2007.11.002_bib5","first-page":"861","article-title":"Tracheal diameter predicts double-lumen tube size: a method for selecting left double-tubes","volume":"82","author":"Brodsky","year":"1996","journal-title":"Anesth Analg"},{"key":"10.1016\/j.jclinane.2007.11.002_bib6","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1053\/jcan.2001.21970","article-title":"The relationship between tracheal width and left bronchial width: implication for left-sided double-lumen tube selection","volume":"15","author":"Brodsky","year":"2001","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.jclinane.2007.11.002_bib7","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/j.jclinane.2004.07.008","article-title":"Tracheal width and left double-lumen tube size: a formula to estimate left-bronchial width","volume":"17","author":"Brodsky","year":"2005","journal-title":"J Clin Anesth"},{"key":"10.1016\/j.jclinane.2007.11.002_bib8","doi-asserted-by":"crossref","first-page":"783","DOI":"10.7863\/jum.1997.16.12.783","article-title":"Sonographic imaging of the trachea","volume":"16","author":"Shih","year":"1997","journal-title":"J Ultrasound Med"},{"key":"10.1016\/j.jclinane.2007.11.002_bib9","doi-asserted-by":"crossref","first-page":"1942","DOI":"10.1097\/00007632-200209010-00026","article-title":"Percutaneous dilatational tracheostomy versus surgical tracheostomy in patients with anterior cervical spine fixation: preliminary report","volume":"27","author":"\u0160usti\u0107","year":"2002","journal-title":"Spine"},{"key":"10.1016\/j.jclinane.2007.11.002_bib10","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1054\/bjom.1999.0072","article-title":"Percutaneous dilatational tracheostomy under ultrasound guidance","volume":"37","author":"Muhammad","year":"1999","journal-title":"Br J Oral Maxillofac Surg"},{"issue":"5 Suppl","key":"10.1016\/j.jclinane.2007.11.002_bib11","doi-asserted-by":"crossref","first-page":"S173","DOI":"10.1097\/01.CCM.0000260628.88402.8A","article-title":"Role of ultrasound in the airway management of critically ill patients","volume":"35","author":"\u0160usti\u0107","year":"2007","journal-title":"Crit Care Med"},{"key":"10.1016\/j.jclinane.2007.11.002_bib12","first-page":"990","article-title":"Comparison of three techniques to inflate the bronchial cuff of left polyvinyl chloride double-lumen tubes","volume":"77","author":"Hannallah","year":"1993","journal-title":"Anesth Analg"},{"key":"10.1016\/j.jclinane.2007.11.002_bib13","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1213\/00000539-199807000-00033","article-title":"Predicting the size of a double-lumen endobronchial tube based on tracheal diameter","volume":"87","author":"Chow","year":"1998","journal-title":"Anesth Analg"},{"key":"10.1016\/j.jclinane.2007.11.002_bib14","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1213\/00000539-199902000-00014","article-title":"Predicting the size of the double-lumen endotracheal tube using computed tomographic scan measurement of the left main bronchus diameter","volume":"88","author":"Chow","year":"1999","journal-title":"Anesth Analg"},{"key":"10.1016\/j.jclinane.2007.11.002_bib15","first-page":"1222","article-title":"The resting volume and compliance characteristics of the bronchial cuff of the left polyvinyl chloride double-lumen endobronchial tube","volume":"77","author":"Hannallah","year":"1993","journal-title":"Anesth Analg"},{"key":"10.1016\/j.jclinane.2007.11.002_bib16","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1016\/S1053-0770(99)90003-4","article-title":"Computed tomography-based tracheobronchial image reconstruction allows selection of the individually appropriate double-tube size","volume":"13","author":"Eberle","year":"1999","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.jclinane.2007.11.002_bib17","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/S1053-0770(97)90208-1","article-title":"Evaluation of an approach to choosing a left double-lumen tube size based on chest computed tomographic scan measurement of left mainstem bronchial diameter","volume":"11","author":"Hannallah","year":"1997","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.jclinane.2007.11.002_bib18","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1378\/chest.130.1.101","article-title":"Measurement of left mainstem bronchus using multiplane CT reconstructions and relationship between patient characteristics or tracheal diameters and left bronchial diameters","volume":"130","author":"Olivier","year":"2006","journal-title":"Chest"},{"key":"10.1016\/j.jclinane.2007.11.002_bib19","doi-asserted-by":"crossref","first-page":"899","DOI":"10.1097\/00005373-200011000-00018","article-title":"Positioning of a double-lumen endobronchal tube without the aid of any instruments: an implication for emergency management","volume":"49","author":"Bahk","year":"2000","journal-title":"J Trauma"}],"container-title":["Journal of Clinical Anesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0952818008000548?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0952818008000548?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T08:55:15Z","timestamp":1760604915000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0952818008000548"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,6]]},"references-count":19,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2008,6]]}},"alternative-id":["S0952818008000548"],"URL":"https:\/\/doi.org\/10.1016\/j.jclinane.2007.11.002","relation":{},"ISSN":["0952-8180"],"issn-type":[{"value":"0952-8180","type":"print"}],"subject":[],"published":{"date-parts":[[2008,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Can ultrasound be useful for predicting the size of a left double-lumen bronchial tube? Tracheal width as measured by ultrasonography versus computed tomography","name":"articletitle","label":"Article Title"},{"value":"Journal of Clinical Anesthesia","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jclinane.2007.11.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2008 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}