{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,17]],"date-time":"2025-10-17T00:14:03Z","timestamp":1760660043330,"version":"build-2065373602"},"reference-count":28,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2011,8,1]],"date-time":"2011-08-01T00:00:00Z","timestamp":1312156800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2011,8,1]],"date-time":"2011-08-01T00:00:00Z","timestamp":1312156800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Clinical Anesthesia"],"published-print":{"date-parts":[[2011,8]]},"DOI":"10.1016\/j.jclinane.2010.11.002","type":"journal-article","created":{"date-parts":[[2011,6,19]],"date-time":"2011-06-19T12:37:33Z","timestamp":1308487053000},"page":"367-371","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":11,"title":["Prompt correction of endotracheal tube positioning after intubation prevents further inappropriate positions"],"prefix":"10.1016","volume":"23","author":[{"given":"Nugzar","family":"Rigini","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mona","family":"Boaz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tiberiu","family":"Ezri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shmuel","family":"Evron","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dimitry","family":"Trigub","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simon","family":"Jackobashvilli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexander","family":"Izakson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jclinane.2010.11.002_bb0005","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1177\/0310057X9302100520","article-title":"The Australian Incident Monitoring Study. Problems related to the endotracheal tube: an analysis of 2000 incident reports","volume":"21","author":"Szekely","year":"1993","journal-title":"Anaesth Intensive Care"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0010","doi-asserted-by":"crossref","first-page":"828","DOI":"10.1097\/00000542-199005000-00010","article-title":"Adverse respiratory events in anesthesia: a closed claim analysis","volume":"72","author":"Caplan","year":"1990","journal-title":"Anesthesiology"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0015","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1097\/00000542-199502000-00007","article-title":"Death and other complications of emergency airway management in critically ill adults. A prospective investigation of 297 tracheal intubations","volume":"82","author":"Schwartz","year":"1995","journal-title":"Anesthesiology"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0020","doi-asserted-by":"crossref","first-page":"1127","DOI":"10.1097\/00003246-199407000-00013","article-title":"Women are at greater risk than men for malpositioning of the endotracheal tube after emergent intubation","volume":"22","author":"Schwartz","year":"1994","journal-title":"Crit Care Med"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0025","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1213\/00000539-198912000-00025","article-title":"Biphasic carbon dioxide elimination waveform with right mainstem bronchial intubation","volume":"69","author":"Gilbert","year":"1989","journal-title":"Anesth Analg"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0030","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1213\/01.ANE.0000118104.23660.F3","article-title":"Auscultation of bilateral breath sounds does not rule out endobronchial intubation in children","volume":"99","author":"Verghese","year":"2004","journal-title":"Anesth Analg"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0035","series-title":"Airway Management: Principles and Practice","first-page":"531","article-title":"Confirmation of tracheal intubation","author":"Salem","year":"1996"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0040","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.jclinane.2005.08.008","article-title":"Use of the Rapiscope vs. chest auscultation for detection of accidental bronchial intubation in non-obese patients undergoing laparoscopic cholecystectomy","volume":"18","author":"Ezri","year":"2006","journal-title":"J Clin Anesth"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0045","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/S0952-8180(98)00051-8","article-title":"Assessment of the proper depth of endotracheal tube placement with the Trachlight","volume":"10","author":"Locker","year":"1998","journal-title":"J Clin Anesth"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0050","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1097\/00006565-199012000-00001","article-title":"Accuracy of flexible fiberoptic endoscopy in identifying abnormal endotracheal tube positions","volume":"6","author":"Dietrich","year":"1990","journal-title":"Pediatr Emerg Care"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0055","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1378\/chest.96.5.1043","article-title":"Assessment of routine chest roentgenograms and the physical examination to confirm endotracheal tube position","volume":"96","author":"Brunel","year":"1989","journal-title":"Chest"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0060","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1111\/j.1365-2044.1985.tb10508.x","article-title":"Fibre-optic assessment of tracheal tube position. A comparison of tracheal tube position as estimated by fibre-optic bronchoscopy and by chest X-ray","volume":"40","author":"O'Brien","year":"1985","journal-title":"Anaesthesia"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0065","first-page":"277","article-title":"Fibre-optic bronchoscopic evaluation of tracheal tube position","volume":"8","author":"Nielsen","year":"1991","journal-title":"Eur J Anaesthesiol"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0070","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1016\/S0889-8537(01)80012-2","article-title":"Verification of endotracheal tube position","volume":"19","author":"Salem","year":"2001","journal-title":"Anesthesiol Clin North America"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0075","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1097\/00000542-198708000-00019","article-title":"Endobronchial intubation: a preventable complication","volume":"67","author":"Owen","year":"1987","journal-title":"Anesthesiology"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0080","series-title":"Fiberoptic endoscopy and the difficult airway","first-page":"164","article-title":"Fiberoptic airway endoscopy in critical care","author":"Ovassapian","year":"1996"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0085","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1097\/00003246-197601000-00002","article-title":"Alteration of endotracheal tube position. Flexion and extension of the neck","volume":"4","author":"Conrardy","year":"1976","journal-title":"Crit Care Med"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0090","first-page":"355","article-title":"Indications, results and complications of flexible fiberoptic bronchoscopy: a 5-year experience in a referral population in Greece","volume":"12","author":"Kaparianos","year":"2008","journal-title":"Eur Rev Med Pharmacol Sci"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0095","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1378\/chest.107.2.430","article-title":"Complications of fiberoptic bronchoscopy at a university hospital","volume":"107","author":"Pue","year":"1995","journal-title":"Chest"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0100","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1378\/chest.98.1.165","article-title":"Self-extubations. A 12-month experience","volume":"98","author":"Cappolo","year":"1990","journal-title":"Chest"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0105","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1177\/0885066609340501","article-title":"Confirmation of endotracheal tube position: a narrative review","volume":"24","author":"Rudraraju","year":"2009","journal-title":"J Intensive Care Med"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0110","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1016\/j.jemermed.2004.12.008","article-title":"Intubation confirmation techniques associated with unrecognized non-tracheal intubations by pre-hospital providers","volume":"28","author":"Bair","year":"2005","journal-title":"J Emerg Med"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0115","first-page":"1380","article-title":"Does the Murphy eye reduce the reliability of chest auscultation in detecting endobronchial intubation?","volume":"88","author":"Sugiyama","year":"1999","journal-title":"Anesth Analg"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0120","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.jclinane.2006.06.005","article-title":"Proper insertion depth of endotracheal tubes in adults by topographic landmarks measurements","volume":"19","author":"Evron","year":"2007","journal-title":"J Clin Anesth"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0125","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1213\/00000539-199802000-00016","article-title":"Pneumoperitoneum as a risk factor for endobronchial intubation during laparoscopic gynecologic surgery","volume":"86","author":"Lobato","year":"1998","journal-title":"Anesth Analg"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0130","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1213\/00000539-200301000-00055","article-title":"The endotracheal tube moves more often in obese patients undergoing laparoscopy compared with open abdominal surgery","volume":"96","author":"Ezri","year":"2003","journal-title":"Anesth Analg"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0135","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1093\/bja\/ael186","article-title":"The clinical implication of the vocal cords-carina distance in anaesthetized Chinese adults during orotracheal intubation","volume":"97","author":"Chong","year":"2006","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.jclinane.2010.11.002_bb0140","first-page":"1369","article-title":"Diagnostic aspects and syndromal associations of short trachea with bronchial intubation","volume":"144","author":"Wells","year":"1990","journal-title":"Am J Dis Child"}],"container-title":["Journal of Clinical Anesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0952818011001310?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0952818011001310?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T08:58:47Z","timestamp":1760605127000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0952818011001310"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,8]]},"references-count":28,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2011,8]]}},"alternative-id":["S0952818011001310"],"URL":"https:\/\/doi.org\/10.1016\/j.jclinane.2010.11.002","relation":{},"ISSN":["0952-8180"],"issn-type":[{"type":"print","value":"0952-8180"}],"subject":[],"published":{"date-parts":[[2011,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Prompt correction of endotracheal tube positioning after intubation prevents further inappropriate positions","name":"articletitle","label":"Article Title"},{"value":"Journal of Clinical Anesthesia","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jclinane.2010.11.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2011 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}