{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,20]],"date-time":"2026-03-20T19:39:16Z","timestamp":1774035556944,"version":"3.50.1"},"reference-count":15,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2011,9,1]],"date-time":"2011-09-01T00:00:00Z","timestamp":1314835200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2011,9,1]],"date-time":"2011-09-01T00:00:00Z","timestamp":1314835200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Clinical Anesthesia"],"published-print":{"date-parts":[[2011,9]]},"DOI":"10.1016\/j.jclinane.2011.01.004","type":"journal-article","created":{"date-parts":[[2011,9,11]],"date-time":"2011-09-11T17:57:00Z","timestamp":1315763820000},"page":"456-460","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":13,"title":["The Laryngeal Mask Airway Supreme for positive pressure ventilation during laparoscopic cholecystectomy"],"prefix":"10.1016","volume":"23","author":[{"given":"Jos\u00e9 M.","family":"Bele\u00f1a","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jos\u00e9 L.","family":"Gracia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jos\u00e9 L.","family":"Ayala","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M\u00f3nica","family":"N\u00fa\u00f1ez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jos\u00e9 A.","family":"Lorenzo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Agust\u00edn","family":"de los Reyes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jos\u00e9 L.","family":"P\u00e9rez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Javier","family":"Yuste","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jclinane.2011.01.004_bb0005","doi-asserted-by":"crossref","first-page":"824","DOI":"10.1093\/bja\/88.6.824","article-title":"ProSeal versus the Classic laryngeal mask airway for positive pressure ventilation during laparoscopic cholecystectomy","volume":"88","author":"Lu","year":"2002","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.jclinane.2011.01.004_bb0010","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1007\/BF03017420","article-title":"The LMA-ProSeal is an effective alternative to tracheal intubation for laparoscopic cholecystectomy","volume":"49","author":"Maltby","year":"2002","journal-title":"Can J Anaesth"},{"key":"10.1016\/j.jclinane.2011.01.004_bb0015","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1007\/BF03020191","article-title":"LMA-Classic and LMA-ProSeal are effective alternatives to endotracheal intubation for gynecologic laparoscopy","volume":"50","author":"Maltby","year":"2003","journal-title":"Can J Anaesth"},{"key":"10.1016\/j.jclinane.2011.01.004_bb0020","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1016\/S0952-8180(03)00085-0","article-title":"Standard Laryngeal Mask Airway and LMA-ProSeal during laparoscopic surgery","volume":"15","author":"Natalini","year":"2003","journal-title":"J Clin Anesth"},{"key":"10.1016\/j.jclinane.2011.01.004_bb0025","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1093\/bja\/82.2.286","article-title":"Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patients","volume":"82","author":"Keller","year":"1999","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.jclinane.2011.01.004_bb0030","doi-asserted-by":"crossref","first-page":"852","DOI":"10.1111\/j.1399-6576.2009.01986.x","article-title":"A new supraglottic airway device: LMA Supreme, comparison with LMA-ProSeal","volume":"53","author":"Hosten","year":"2009","journal-title":"Acta Anaesthesiol Scand"},{"key":"10.1016\/j.jclinane.2011.01.004_bb0035","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1097\/ALN.0b013e3181942c4d","article-title":"Prospective clinical and fiberoptic evaluation of the Supreme laryngeal mask airway","volume":"110","author":"Timmermann","year":"2009","journal-title":"Anesthesiology"},{"key":"10.1016\/j.jclinane.2011.01.004_bb0040","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1093\/bja\/aen174","article-title":"LMA-Supreme\u2013a new single-use LMA with gastric access: a report on its clinical efficacy","volume":"101","author":"Verghese","year":"2008","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.jclinane.2011.01.004_bb0045","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1111\/j.1365-2044.2008.05682.x","article-title":"The laryngeal mask airway Supreme \u2014a single use laryngeal mask airway with an oesophageal vent. A randomised, cross-over study with the laryngeal mask airway ProSeal in paralysed, anaesthetised patients","volume":"64","author":"Eschertzhuber","year":"2009","journal-title":"Anaesthesia"},{"key":"10.1016\/j.jclinane.2011.01.004_bb0050","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1111\/j.1365-2044.2008.05824.x","article-title":"Evaluation of the LMA Supreme in 100 non-paralysed patients","volume":"64","author":"Cook","year":"2009","journal-title":"Anaesthesia"},{"key":"10.1016\/j.jclinane.2011.01.004_bb0055","first-page":"770","article-title":"A comparison of the laryngeal mask airway ProSeal and the laryngeal tube airway in paralyzed anesthestized adult patients undergoing pressure-contolled ventilation","volume":"95","author":"Brimacombe","year":"2002","journal-title":"Anesth Analg"},{"key":"10.1016\/j.jclinane.2011.01.004_bb0060","doi-asserted-by":"crossref","first-page":"1351","DOI":"10.1097\/00000539-200111000-00064","article-title":"Positive pressure ventilation with the ProSeal versus classic laryngeal mask airway: a randomized, crossover study of healthy female patients","volume":"93","author":"Brimacombe","year":"2001","journal-title":"Anesth Analg"},{"key":"10.1016\/j.jclinane.2011.01.004_bb0065","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1093\/bja\/81.2.186","article-title":"The influence of cuff volume on oropharyngeal leak pressure and fibreoptic position with the laryngeal mask airway","volume":"81","author":"Keller","year":"1998","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.jclinane.2011.01.004_bb0070","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1111\/j.1365-2044.2007.05421.x","article-title":"The LMA Supreme\u2013a pilot study","volume":"63","author":"van Zundert","year":"2008","journal-title":"Anaesthesia"},{"key":"10.1016\/j.jclinane.2011.01.004_bb0075","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1093\/bja\/aeq223","article-title":"Usefulness of spirometry in air leak evaluation during laparoscopic surgery in an obese patient with LMA Supreme","volume":"105","author":"Carron","year":"2010","journal-title":"Br J Anaesth"}],"container-title":["Journal of Clinical Anesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0952818011002492?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0952818011002492?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T08:58:53Z","timestamp":1760605133000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0952818011002492"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,9]]},"references-count":15,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2011,9]]}},"alternative-id":["S0952818011002492"],"URL":"https:\/\/doi.org\/10.1016\/j.jclinane.2011.01.004","relation":{},"ISSN":["0952-8180"],"issn-type":[{"value":"0952-8180","type":"print"}],"subject":[],"published":{"date-parts":[[2011,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The Laryngeal Mask Airway Supreme for positive pressure ventilation during laparoscopic cholecystectomy","name":"articletitle","label":"Article Title"},{"value":"Journal of Clinical Anesthesia","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jclinane.2011.01.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2011 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}