{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T03:36:08Z","timestamp":1777347368053,"version":"3.51.4"},"reference-count":16,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2014,5,1]],"date-time":"2014-05-01T00:00:00Z","timestamp":1398902400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2014,5,1]],"date-time":"2014-05-01T00:00:00Z","timestamp":1398902400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Clinical Anesthesia"],"published-print":{"date-parts":[[2014,5]]},"DOI":"10.1016\/j.jclinane.2013.10.012","type":"journal-article","created":{"date-parts":[[2014,5,5]],"date-time":"2014-05-05T16:45:47Z","timestamp":1399308347000},"page":"199-203","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":11,"title":["Comparison of the Airtraq and McCoy laryngoscopes using a rigid neck collar in patients with simulated difficult laryngoscopy"],"prefix":"10.1016","volume":"26","author":[{"given":"Qazi Ehsan","family":"Ali","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bikramjit","family":"Das","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Syed Hussain","family":"Amir","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Obaid Ahmed","family":"Siddiqui","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shaista","family":"Jamil","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.jclinane.2013.10.012_bb0005","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1007\/s00540-010-1038-7","article-title":"Efficacy of the Airtraq laryngoscope","volume":"25","author":"Nishikawa","year":"2011","journal-title":"J Anesth"},{"key":"10.1016\/j.jclinane.2013.10.012_bb0010","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1111\/j.1365-2044.2008.05757.x","article-title":"Optimising tracheal intubation success rate using the Airtraq laryngoscope","volume":"64","author":"Dhonneur","year":"2009","journal-title":"Anaesthesia"},{"key":"10.1016\/j.jclinane.2013.10.012_bb0015","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1097\/ALN.0b013e3181a8649f","article-title":"Cervical spine motion: a fluoroscopic comparison of the AirTraq Laryngoscope versus the Macintosh laryngoscope","volume":"111","author":"Turkstra","year":"2009","journal-title":"Anesthesiology"},{"key":"10.1016\/j.jclinane.2013.10.012_bb0020","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1111\/j.1365-2044.2006.04547.x","article-title":"Evaluation of intubation using the Airtraq or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy \u2013 a manikin study","volume":"61","author":"Maharaj","year":"2006","journal-title":"Anaesthesia"},{"key":"10.1016\/j.jclinane.2013.10.012_bb0025","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1016\/j.ajme.2012.03.002","article-title":"Comparative study between the use of Macintosh Laryngoscope and Airtraq in patients with cervical spine immobilization","volume":"48","author":"Tolon","year":"2012","journal-title":"Alexandria Med J"},{"key":"10.1016\/j.jclinane.2013.10.012_bb0030","doi-asserted-by":"crossref","first-page":"812","DOI":"10.1111\/j.1365-2044.1996.tb12606.x","article-title":"Laryngoscopy using the McCoy laryngoscope after application of a cervical collar","volume":"51","author":"Gabbott","year":"1996","journal-title":"Anaesthesia"},{"key":"10.1016\/j.jclinane.2013.10.012_bb0035","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1111\/j.1365-2044.1996.tb07659.x","article-title":"The use of the McCoy laryngoscope in patients with simulated cervical spine injuries","volume":"51","author":"Laurent","year":"1996","journal-title":"Anaesthesia"},{"key":"10.1016\/j.jclinane.2013.10.012_bb0040","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1046\/j.1365-2044.2000.01270.x","article-title":"A new practical classification of laryngeal view","volume":"55","author":"Cook","year":"2000","journal-title":"Anaesthesia"},{"key":"10.1016\/j.jclinane.2013.10.012_bb0045","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1007\/BF03013137","article-title":"Assessment of laryngeal view: percentage of glottic opening score vs Cormack and Lehane grading","volume":"46","author":"Ochroch","year":"1999","journal-title":"Can J Anesth"},{"key":"10.1016\/j.jclinane.2013.10.012_bb0050","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1111\/j.1365-2044.2006.04819.x","article-title":"A comparison of tracheal intubation using the Airtraq or the Macintosh laryngoscope in routine airway management: a randomised, controlled clinical trial","volume":"61","author":"Maharaj","year":"2006","journal-title":"Anaesthesia"},{"key":"10.1016\/j.jclinane.2013.10.012_bb0055","unstructured":"Elhospital.com [Internet]. King Systems: Airtraq optical laryngoscope disposable; c2008 [cited Jan. 10, 2012]. Available from: http:\/\/www.elhospital.com\/eh\/formas\/78685\/13-AirtraqLit.pdf."},{"key":"10.1016\/j.jclinane.2013.10.012_bb0060","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1093\/bja\/aei190","article-title":"Reduction in mouth opening with semi-rigid cervical collars","volume":"95","author":"Goutcher","year":"2005","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.jclinane.2013.10.012_bb0065","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1093\/bja\/aen288","article-title":"Airway scope and gum elastic bougie with Macintosh laryngoscope for tracheal intubation in patients with simulated restricted neck mobility","volume":"101","author":"Komatsu","year":"2008","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.jclinane.2013.10.012_bb0070","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1111\/j.1365-2044.1994.tb04254.x","article-title":"The effect of laryngoscopy of different cervical spine immobilisation techniques","volume":"49","author":"Heath","year":"1994","journal-title":"Anaesthesia"},{"key":"10.1016\/j.jclinane.2013.10.012_bb0075","doi-asserted-by":"crossref","first-page":"760","DOI":"10.1007\/BF03013911","article-title":"Tracheal intubation using Bullard laryngoscope for patients with a simulated difficult airway","volume":"46","author":"MacQuarrie","year":"1999","journal-title":"Can J Anaesth"},{"key":"10.1016\/j.jclinane.2013.10.012_bb0080","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1111\/j.1365-2044.1993.tb07133.x","article-title":"Orotracheal intubation in patients with potential cervical spine injuries. An indication for the gum elastic bougie","volume":"48","author":"Nolan","year":"1993","journal-title":"Anaesthesia"}],"container-title":["Journal of Clinical Anesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0952818014000300?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0952818014000300?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T09:02:17Z","timestamp":1760605337000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0952818014000300"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,5]]},"references-count":16,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2014,5]]}},"alternative-id":["S0952818014000300"],"URL":"https:\/\/doi.org\/10.1016\/j.jclinane.2013.10.012","relation":{},"ISSN":["0952-8180"],"issn-type":[{"value":"0952-8180","type":"print"}],"subject":[],"published":{"date-parts":[[2014,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of the Airtraq and McCoy laryngoscopes using a rigid neck collar in patients with simulated difficult laryngoscopy","name":"articletitle","label":"Article Title"},{"value":"Journal of Clinical Anesthesia","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jclinane.2013.10.012","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}