{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,18]],"date-time":"2026-10-18T09:00:32Z","timestamp":1792314032741,"version":"4.4.0"},"reference-count":27,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2018,2,1]],"date-time":"2018-02-01T00:00:00Z","timestamp":1517443200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2018,2,1]],"date-time":"2018-02-01T00:00:00Z","timestamp":1517443200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Clinical Anesthesia"],"published-print":{"date-parts":[[2018,2]]},"DOI":"10.1016\/j.jclinane.2017.11.008","type":"journal-article","created":{"date-parts":[[2017,11,21]],"date-time":"2017-11-21T10:00:09Z","timestamp":1511258409000},"page":"69-75","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":65,"special_numbering":"C","title":["Videolaryngoscope versus Macintosh laryngoscope for tracheal intubation in adults with obesity: A systematic review and meta-analysis"],"prefix":"10.1016","volume":"44","author":[{"given":"Hiroshi","family":"Hoshijima","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yohei","family":"Denawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Asako","family":"Tominaga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"China","family":"Nakamura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshiya","family":"Shiga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Nagasaka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jclinane.2017.11.008_bb0005","doi-asserted-by":"crossref","first-page":"1160","DOI":"10.1111\/j.1365-2044.2011.06871.x","article-title":"Airtraq laryngoscope versus conventional Macintosh laryngoscope: a systematic review and meta-analysis","volume":"66","author":"Lu","year":"2011","journal-title":"Anaesthesia"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0010","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1007\/s12630-011-9620-5","article-title":"Glidescope(R) video-laryngoscopy versus direct laryngoscopy for endotracheal intubation: a systematic review and meta-analysis","volume":"59","author":"Griesdale","year":"2012","journal-title":"Can J Anaesth"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0015","doi-asserted-by":"crossref","first-page":"911","DOI":"10.1111\/anae.12705","article-title":"Pentax Airway Scope(R) vs Macintosh laryngoscope for tracheal intubation in adult patients: a systematic review and meta-analysis","volume":"69","author":"Hoshijima","year":"2014","journal-title":"Anaesthesia"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0020","doi-asserted-by":"crossref","first-page":"1082","DOI":"10.1213\/ANE.0b013e31822cf47d","article-title":"A randomized comparison between the Pentax AWS video laryngoscope and the Macintosh laryngoscope in morbidly obese patients","volume":"113","author":"Abdallah","year":"2011","journal-title":"Anesth Analg"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0025","doi-asserted-by":"crossref","first-page":"1090","DOI":"10.1111\/j.1399-6576.2011.02498.x","article-title":"GlideScope videolaryngoscope vs. Macintosh direct laryngoscope for intubation of morbidly obese patients: a randomized trial","volume":"55","author":"Andersen","year":"2011","journal-title":"Acta Anaesthesiol Scand"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0030","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1111\/j.1365-2044.2006.04819.x","article-title":"A comparison of tracheal intubation using the Airtraq or the Macintosh laryngoscope in routine airway management: a randomised, controlled clinical trial","volume":"61","author":"Maharaj","year":"2006","journal-title":"Anaesthesia"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0035","first-page":"147","article-title":"Prevalence of obesity in surgical patients: a comparative survey in the United States and Australia","volume":"17","author":"Riley","year":"1997","journal-title":"J Qual Clin Pract"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0040","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1213\/01.ANE.0000072547.75928.B0","article-title":"Difficult tracheal intubation is more common in obese than in lean patients","volume":"97","author":"Juvin","year":"2003","journal-title":"Anesth Analg."},{"key":"10.1016\/j.jclinane.2017.11.008_bb0045","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1097\/00000542-200508000-00027","article-title":"Predicting difficult intubation in apparently normal patients: a meta-analysis of bedside screening test performance","volume":"103","author":"Shiga","year":"2005","journal-title":"Anesthesiology"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0050","doi-asserted-by":"crossref","first-page":"1132","DOI":"10.1213\/ane.0b013e3181679659","article-title":"The importance of increased neck circumference to intubation difficulties in obese patients","volume":"106","author":"Gonzalez","year":"2008","journal-title":"Anesth Analg."},{"key":"10.1016\/j.jclinane.2017.11.008_bb0055","doi-asserted-by":"crossref","first-page":"1096","DOI":"10.1007\/s11695-008-9719-0","article-title":"Video-assisted versus conventional tracheal intubation in morbidly obese patients","volume":"19","author":"Dhonneur","year":"2009","journal-title":"Obes Surg"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0060","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/j.jclinane.2015.12.042","article-title":"Comparison of three video laryngoscopy devices to direct laryngoscopy for intubating obese patients: a randomized controlled trial","volume":"31","author":"Yumul","year":"2016","journal-title":"J Clin Anesth"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0065","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.jclinane.2016.10.023","article-title":"Comparison of the macintosh and airtraq laryngoscopes in morbidly obese patients: a randomized and prospective study","volume":"36","author":"Castillo-Monzon","year":"2017","journal-title":"J Clin Anesth"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0070","first-page":"190","article-title":"Preanesthetic assessment data do not influence the time for tracheal intubation with Airtraq video laryngoscope in obese patients","volume":"64","author":"Ranieri","year":"2014","journal-title":"Braz J Anesthesiol"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0075","doi-asserted-by":"crossref","first-page":"1045","DOI":"10.1017\/S0265021507000889","article-title":"Videolaryngoscopy improves intubation condition in morbidly obese patients","volume":"24","author":"Marrel","year":"2007","journal-title":"Eur J Anaesthesiol"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0080","doi-asserted-by":"crossref","first-page":"387","DOI":"10.3906\/sag-1306-71","article-title":"The McGrath Series 5 video laryngoscope versus the Macintosh laryngoscope: a randomized trial in obstetric patients","volume":"44","author":"Arici","year":"2014","journal-title":"Turk J Med Sci"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0085","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1093\/bja\/aem346","article-title":"Tracheal intubation of morbidly obese patients: a randomized trial comparing performance of Macintosh and Airtraq laryngoscopes","volume":"100","author":"Ndoko","year":"2008","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0090","first-page":"e123","article-title":"Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement","volume":"3","author":"Moher","year":"2009","journal-title":"Open Med"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0095","series-title":"The Cochrane collaboration","article-title":"Cochrane handbook for systematic reviews of interventions version 5.1.0","author":"Higgins","year":"2011"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0100","doi-asserted-by":"crossref","first-page":"1490","DOI":"10.1136\/bmj.328.7454.1490","article-title":"Grading quality of evidence and strength of recommendations","volume":"328","author":"Atkins","year":"2004","journal-title":"BMJ"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0105","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1136\/bmj.327.7414.557","article-title":"Measuring inconsistency in meta-analyses","volume":"327","author":"Higgins","year":"2003","journal-title":"BMJ"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0110","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1136\/bmj.315.7109.629","article-title":"Bias in meta-analysis detected by a simple, graphical test","volume":"315","author":"Egger","year":"1997","journal-title":"BMJ"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0115","doi-asserted-by":"crossref","first-page":"1088","DOI":"10.2307\/2533446","article-title":"Operating characteristics of a rank correlation test for publication bias","volume":"50","author":"Begg","year":"1994","journal-title":"Biometrics"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0120","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1007\/BF03027728","article-title":"Early clinical experience with a new videolaryngoscope (GlideScope) in 728 patients","volume":"52","author":"Cooper","year":"2005","journal-title":"Can J Anaesth"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0125","first-page":"451","article-title":"The clinical assessment of Glidescope in orotracheal intubation under general anesthesia","volume":"73","author":"Xue","year":"2007","journal-title":"Minerva Anestesiol"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0130","doi-asserted-by":"crossref","first-page":"35","DOI":"10.4103\/2229-5151.128011","article-title":"Videolaryngoscopy","volume":"4","author":"Chemsian","year":"2014","journal-title":"Int J Crit Illn Inj Sci"},{"key":"10.1016\/j.jclinane.2017.11.008_bb0135","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1111\/j.1399-6576.2010.02285.x","article-title":"Video-laryngoscopes in the adult airway management: a topical review of the literature","volume":"54","author":"Niforopoulou","year":"2010","journal-title":"Acta Anaesthesiol Scand"}],"container-title":["Journal of Clinical Anesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0952818017309789?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0952818017309789?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T09:09:01Z","timestamp":1760605741000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0952818017309789"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,2]]},"references-count":27,"alternative-id":["S0952818017309789"],"URL":"https:\/\/doi.org\/10.1016\/j.jclinane.2017.11.008","relation":{},"ISSN":["0952-8180"],"issn-type":[{"value":"0952-8180","type":"print"}],"subject":[],"published":{"date-parts":[[2018,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Videolaryngoscope versus Macintosh laryngoscope for tracheal intubation in adults with obesity: A systematic review and meta-analysis","name":"articletitle","label":"Article Title"},{"value":"Journal of Clinical Anesthesia","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jclinane.2017.11.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}