{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T17:05:32Z","timestamp":1793725532763,"version":"4.6.1"},"reference-count":77,"publisher":"Elsevier BV","issue":"12","license":[{"start":{"date-parts":[[2017,12,1]],"date-time":"2017-12-01T00:00:00Z","timestamp":1512086400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2017,12,1]],"date-time":"2017-12-01T00:00:00Z","timestamp":1512086400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2018,12,1]],"date-time":"2018-12-01T00:00:00Z","timestamp":1543622400000},"content-version":"vor","delay-in-days":365,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100008497","name":"Boston Scientific Corporation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008497","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100011949","name":"Abbott Vascular","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100011949","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jacc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JACC: Cardiovascular Imaging"],"published-print":{"date-parts":[[2017,12]]},"DOI":"10.1016\/j.jcmg.2017.09.008","type":"journal-article","created":{"date-parts":[[2017,12,5]],"date-time":"2017-12-05T12:55:11Z","timestamp":1512478511000},"page":"1487-1503","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":235,"title":["IVUS-Guided Versus OCT-Guided Coronary\u00a0Stent Implantation"],"prefix":"10.1016","volume":"10","author":[{"given":"Akiko","family":"Maehara","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mitsuaki","family":"Matsumura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ziad A.","family":"Ali","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gary S.","family":"Mintz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregg W.","family":"Stone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jcmg.2017.09.008_bib1","doi-asserted-by":"crossref","first-page":"1224","DOI":"10.1053\/euhj.1998.1028","article-title":"Treatment of calcified coronary lesions with Palmaz-Schatz stents. An intravascular ultrasound study","volume":"19","author":"Hoffmann","year":"1998","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jcmg.2017.09.008_bib2","doi-asserted-by":"crossref","first-page":"2209","DOI":"10.1253\/circj.CJ-14-0108","article-title":"Impact of target lesion coronary calcification on stent expansion","volume":"78","author":"Kobayashi","year":"2014","journal-title":"Circ J"},{"key":"10.1016\/j.jcmg.2017.09.008_bib3","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.ahj.2012.09.017","article-title":"A\u00a0prospective, randomized trial of intravascular-ultrasound guided compared to angiography guided stent implantation in complex coronary lesions: the AVIO trial","volume":"165","author":"Chieffo","year":"2013","journal-title":"Am Heart J"},{"key":"10.1016\/j.jcmg.2017.09.008_bib4","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1161\/CIRCULATIONAHA.113.003942","article-title":"Relationship between intravascular ultrasound guidance and clinical outcomes after drug-eluting stents: the Assessment Of Dual Antiplatelet Therapy with Drug-Eluting Stents (ADAPT-DES) study","volume":"129","author":"Witzenbichler","year":"2014","journal-title":"Circulation"},{"key":"10.1016\/j.jcmg.2017.09.008_bib5","doi-asserted-by":"crossref","first-page":"2618","DOI":"10.1016\/S0140-6736(16)31922-5","article-title":"Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial","volume":"388","author":"Ali","year":"2016","journal-title":"Lancet"},{"key":"10.1016\/j.jcmg.2017.09.008_bib6","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1016\/j.amjcard.2008.10.010","article-title":"An integrated TAXUS IV, V, and VI intravascular ultrasound analysis of the predictors of edge restenosis after bare metal or paclitaxel-eluting stents","volume":"103","author":"Liu","year":"2009","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jcmg.2017.09.008_bib7","doi-asserted-by":"crossref","first-page":"1408","DOI":"10.1016\/j.amjcard.2013.01.288","article-title":"Intravascular ultrasound predictors for edge restenosis after newer generation drug-eluting stent implantation","volume":"111","author":"Kang","year":"2013","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jcmg.2017.09.008_bib8","doi-asserted-by":"crossref","first-page":"e004231","DOI":"10.1161\/CIRCINTERVENTIONS.116.004231","article-title":"Optical coherence tomography predictors for edge restenosis after everolimus-eluting stent implantation","volume":"9","author":"Ino","year":"2016","journal-title":"Circ Cardiovasc Interv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib9","doi-asserted-by":"crossref","first-page":"1012","DOI":"10.1016\/S0002-9149(99)00006-5","article-title":"Does the specific intravascular ultrasound criterion used to optimize stent expansion have an impact on the probability of stent restenosis?","volume":"83","author":"Moussa","year":"1999","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jcmg.2017.09.008_bib10","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1161\/CIRCINTERVENTIONS.111.964643","article-title":"Comprehensive intravascular ultrasound assessment of stent area and its impact on restenosis and adverse cardiac events in 403 patients with unprotected left main disease","volume":"4","author":"Kang","year":"2011","journal-title":"Circ Cardiovasc Interv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib11","doi-asserted-by":"crossref","first-page":"1269","DOI":"10.1016\/j.jcin.2009.10.005","article-title":"Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxel-eluting stents: an integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials","volume":"2","author":"Doi","year":"2009","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib12","first-page":"873","article-title":"Intravascular ultrasound assessment of optimal stent area to prevent in-stent restenosis after zotarolimus-, everolimus-, and sirolimus-eluting stent implantation","volume":"83","author":"Song","year":"2014","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib13","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1016\/j.amjcard.2011.10.005","article-title":"Intravascular ultrasound findings of early stent thrombosis after primary percutaneous intervention in acute myocardial infarction: a Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) substudy","volume":"109","author":"Choi","year":"2012","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jcmg.2017.09.008_bib14","doi-asserted-by":"crossref","first-page":"995","DOI":"10.1016\/j.jacc.2004.12.066","article-title":"Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study","volume":"45","author":"Fujii","year":"2005","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcmg.2017.09.008_bib15","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1016\/j.jcin.2009.01.011","article-title":"A\u00a0volumetric intravascular ultrasound comparison of early drug-eluting stent thrombosis versus restenosis","volume":"5","author":"Liu","year":"2009","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib16","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1161\/CIRCINTERVENTIONS.110.959791","article-title":"Intravascular ultrasound findings of early stent thrombosis after primary percutaneous intervention in acute myocardial infarction: a Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) substudy","volume":"4","author":"Choi","year":"2011","journal-title":"Circ Cardiovasc Interv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib17","doi-asserted-by":"crossref","first-page":"1020","DOI":"10.1161\/CIRCULATIONAHA.114.014704","article-title":"Incidence and clinical significance of poststent optical coherence tomography findings: one-year follow-up study from a multicenter registry","volume":"132","author":"Soeda","year":"2015","journal-title":"Circulation"},{"key":"10.1016\/j.jcmg.2017.09.008_bib18","doi-asserted-by":"crossref","first-page":"1297","DOI":"10.1016\/j.jcmg.2015.08.013","article-title":"Clinical Impact of OCT Findings During PCI: the CLI-OPCI II Study","volume":"8","author":"Prati","year":"2015","journal-title":"J\u00a0Am Coll Cardiol Img"},{"key":"10.1016\/j.jcmg.2017.09.008_bib19","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1161\/CIRCINTERVENTIONS.113.000797","article-title":"Incidence, predictors, and clinical outcomes of acute and late stent malapposition detected by optical coherence tomography after drug-eluting stent implantation","volume":"7","author":"Im","year":"2014","journal-title":"Circ Cardiovasc Interv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib20","first-page":"566","article-title":"Role of residual acute stent malapposition in percutaneous coronary interventions","volume":"90","author":"Romagnoli","year":"2017","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib21","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.ahj.2014.11.012","article-title":"Suboptimal stent deployment is associated with subacute stent thrombosis: optical coherence tomography insights from a multicenter matched study. From the CLI Foundation investigators: the CLI-THRO study","volume":"169","author":"Prati","year":"2015","journal-title":"Am Heart J"},{"key":"10.1016\/j.jcmg.2017.09.008_bib22","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.1161\/CIRCULATIONAHA.109.906040","volume":"122","author":"Guo","year":"2010","journal-title":"Circulation"},{"key":"10.1016\/j.jcmg.2017.09.008_bib23","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1016\/j.jcin.2010.03.007","article-title":"Long-term impact of routinely detected early and late incomplete stent apposition: an integrated intravascular ultrasound analysis of the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, long lesion, and direct stent studies","volume":"3","author":"Steinberg","year":"2010","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib24","doi-asserted-by":"crossref","first-page":"e004438","DOI":"10.1161\/JAHA.116.004438","article-title":"Predictors and long-term clinical impact of acute stent malapposition: an Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents (ADAPT-DES) intravascular ultrasound substudy","volume":"5","author":"Wang","year":"2016","journal-title":"J\u00a0Am Heart Assoc"},{"key":"10.1016\/j.jcmg.2017.09.008_bib25","doi-asserted-by":"crossref","first-page":"e003552","DOI":"10.1161\/CIRCINTERVENTIONS.115.003553","article-title":"Prevalence, features, and prognostic importance of edge dissection after drug-eluting stent implantation: an ADAPT-DES Intravascular Ultrasound Substudy","volume":"9","author":"Kobayashi","year":"2016","journal-title":"Circ Cardiovasc Interv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib26","doi-asserted-by":"crossref","first-page":"1499","DOI":"10.1016\/j.jcin.2016.05.043","article-title":"Prevalence and clinical impact of tissue protrusion after stent implantation: an ADAPT-DES Intravascular Ultrasound Substudy","volume":"9","author":"Qiu","year":"2016","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib27","doi-asserted-by":"crossref","first-page":"1351","DOI":"10.1016\/j.amjcard.2015.07.058","article-title":"Mechanisms and patterns of intravascular ultrasound in-stent restenosis among bare metal stents and first- and second-generation drug-eluting stents","volume":"116","author":"Goto","year":"2015","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jcmg.2017.09.008_bib28","doi-asserted-by":"crossref","first-page":"294","DOI":"10.4244\/EIJ-D-16-00787","article-title":"Characteristics of early versus late in-stent restenosis in second-generation drug-eluting stents: an optical coherence tomography study","volume":"13","author":"Song","year":"2017","journal-title":"EuroIntervention"},{"key":"10.1016\/j.jcmg.2017.09.008_bib29","doi-asserted-by":"crossref","first-page":"1208","DOI":"10.1093\/eurheartj\/ehv711","article-title":"Mechanisms of stent thrombosis analysed by optical coherence tomography: insights from the national PESTO French registry","volume":"37","author":"Souteyrand","year":"2016","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jcmg.2017.09.008_bib30","doi-asserted-by":"crossref","first-page":"1058","DOI":"10.1016\/j.jacc.2011.09.079","article-title":"Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: a report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation","volume":"59","author":"Tearney","year":"2012","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcmg.2017.09.008_bib31","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1097\/MCA.0000000000000072","article-title":"Comprehensive overview of definitions for optical coherence tomography-based plaque and stent analyses","volume":"25","author":"Di Vito","year":"2014","journal-title":"Coron Artery Dis"},{"key":"10.1016\/j.jcmg.2017.09.008_bib32","doi-asserted-by":"crossref","first-page":"1478","DOI":"10.1016\/S0735-1097(01)01175-5","volume":"37","author":"Mintz","year":"2001","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcmg.2017.09.008_bib33","doi-asserted-by":"crossref","first-page":"756","DOI":"10.1093\/ehjci\/jev229","article-title":"Multi-laboratory inter-institute reproducibility study of IVOCT and IVUS assessments using published consensus document definitions","volume":"17","author":"Gerbaud","year":"2016","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"10.1016\/j.jcmg.2017.09.008_bib34","doi-asserted-by":"crossref","first-page":"1371","DOI":"10.1056\/NEJM198705283162204","article-title":"Compensatory enlargement of human atherosclerotic coronary arteries","volume":"316","author":"Glagov","year":"1987","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.jcmg.2017.09.008_bib35","doi-asserted-by":"crossref","first-page":"1095","DOI":"10.1016\/j.jcmg.2013.04.014","article-title":"Optical coherence tomography compared to intravascular ultrasound in coronary lesion assessment study: OPUS-CLASS study","volume":"6","author":"Kubo","year":"2013","journal-title":"J\u00a0Am Coll Cardiol Img"},{"key":"10.1016\/j.jcmg.2017.09.008_bib36","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1016\/j.jcin.2012.09.017","article-title":"Optical coherence tomography versus intravascular ultrasound to evaluate coronary artery disease and percutaneous coronary intervention","volume":"6","author":"Bezerra","year":"2013","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib37","doi-asserted-by":"crossref","first-page":"1841","DOI":"10.1253\/circj.CJ-09-0113","article-title":"Factors that influence measurements and accurate evaluation of stent apposition by optical coherence tomography. Assessment using a phantom model","volume":"73","author":"Sawada","year":"2009","journal-title":"Circ J"},{"key":"10.1016\/j.jcmg.2017.09.008_bib38","doi-asserted-by":"crossref","first-page":"823","DOI":"10.4244\/EIJV8I7A125","article-title":"Angiography alone versus angiography plus optical coherence tomography to guide decision-making during percutaneous coronary intervention: the Centro per la Lotta contro l'Infarto-Optimisation of Percutaneous Coronary Intervention (CLI-OPCI) study","volume":"8","author":"Prati","year":"2012","journal-title":"EuroIntervention"},{"key":"10.1016\/j.jcmg.2017.09.008_bib39","doi-asserted-by":"crossref","first-page":"906","DOI":"10.1161\/CIRCULATIONAHA.116.024393","volume":"134","author":"Meneveau","year":"2016","journal-title":"Circulation"},{"key":"10.1016\/j.jcmg.2017.09.008_bib40","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1161\/CIRCINTERVENTIONS.111.965111","article-title":"Impact of frequency-domain optical coherence tomography guidance for optimal coronary stent implantation in comparison with intravascular ultrasound guidance","volume":"5","author":"Habara","year":"2012","journal-title":"Circ Cardiovasc Interv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib41","doi-asserted-by":"crossref","first-page":"3139","DOI":"10.1093\/eurheartj\/ehx351","article-title":"Optical frequency domain imaging vs. intravascular ultrasound in percutaneous coronary intervention (OPINION trial): one-year angiographic and clinical results","volume":"38","author":"Kubo","year":"2017","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jcmg.2017.09.008_bib42","first-page":"467","article-title":"Safety of optical coherence tomography in daily practice: a comparison with intravascular ultrasound","volume":"18","author":"van der Sijde","year":"2017","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"10.1016\/j.jcmg.2017.09.008_bib43","doi-asserted-by":"crossref","first-page":"1102","DOI":"10.1161\/CIRCIMAGING.113.000448","article-title":"Intracoronary and noninvasive imaging for prediction of distal embolization and periprocedural myocardial infarction during native coronary artery percutaneous intervention","volume":"6","author":"Patel","year":"2013","journal-title":"Circ Cardiovasc Imaging"},{"key":"10.1016\/j.jcmg.2017.09.008_bib44","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1161\/CIRCINTERVENTIONS.108.821124","article-title":"Clinical significance of echo signal attenuation on intravascular ultrasound in patients with coronary artery disease","volume":"2","author":"Kimura","year":"2009","journal-title":"Circ Cardiovasc Interv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib45","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1016\/j.jcin.2010.01.015","article-title":"Impact of ultrasound attenuation and plaque rupture as detected by intravascular ultrasound on the incidence of no-reflow phenomenon after percutaneous coronary intervention in ST-segment elevation myocardial infarction","volume":"3","author":"Endo","year":"2010","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib46","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1161\/CIRCINTERVENTIONS.112.000248","article-title":"Increased thin-cap neoatheroma and periprocedural myocardial infarction in drug-eluting stent restenosis: multimodality intravascular imaging of drug-eluting and bare-metal stents","volume":"6","author":"Ali","year":"2013","journal-title":"Circ Cardiovasc Interv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib47","doi-asserted-by":"crossref","first-page":"2220","DOI":"10.1016\/j.jacc.2014.02.576","article-title":"Insights into echo-attenuated plaques, echolucent plaques, and plaques with spotty calcification: novel findings from comparisons among intravascular ultrasound, near-infrared spectroscopy, and pathological histology in 2,294 human coronary artery segments","volume":"63","author":"Pu","year":"2014","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcmg.2017.09.008_bib48","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1016\/S0002-8703(99)70496-5","article-title":"Calcified plaque cross-sectional area in human arteries: correlation between intravascular ultrasound and undecalcified histology","volume":"137","author":"Kostamaa","year":"1999","journal-title":"Am Heart J"},{"key":"10.1016\/j.jcmg.2017.09.008_bib49","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1016\/0002-8703(94)90614-9","article-title":"Detection of intralesional calcium by intracoronary ultrasound depends on the histologic pattern","volume":"128","author":"Friedrich","year":"1994","journal-title":"Am Heart J"},{"key":"10.1016\/j.jcmg.2017.09.008_bib50","doi-asserted-by":"crossref","first-page":"1959","DOI":"10.1161\/01.CIR.91.7.1959","article-title":"Patterns of calcification in coronary artery disease. A statistical analysis of intravascular ultrasound and coronary angiography in 1155 lesions","volume":"91","author":"Mintz","year":"1995","journal-title":"Circulation"},{"key":"10.1016\/j.jcmg.2017.09.008_bib51","doi-asserted-by":"crossref","first-page":"1413","DOI":"10.1253\/circj.CJ-15-1059","article-title":"Relationship between thickness of calcium on optical coherence tomography and crack formation after balloon dilatation in calcified plaque requiring rotational atherectomy","volume":"80","author":"Maejima","year":"2016","journal-title":"Circ J"},{"key":"10.1016\/j.jcmg.2017.09.008_bib52","doi-asserted-by":"crossref","first-page":"1228","DOI":"10.1016\/j.jcmg.2014.11.012","article-title":"Superficial calcium fracture After PCI as assessed by OCT","volume":"10","author":"Kubo","year":"2015","journal-title":"J\u00a0Am Coll Cardiol Img"},{"key":"10.1016\/j.jcmg.2017.09.008_bib53","doi-asserted-by":"crossref","first-page":"1214","DOI":"10.1053\/euhj.1998.1012","article-title":"Intravascular ultrasound-guided optimized stent deployment. Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study)","volume":"19","author":"de Jaegere","year":"1998","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jcmg.2017.09.008_bib54","doi-asserted-by":"crossref","first-page":"1479","DOI":"10.1016\/0735-1097(95)00088-L","article-title":"Atherosclerosis in angiographically \u201cnormal\u201d coronary artery reference segments: an intravascular ultrasound study with clinical correlations","volume":"25","author":"Mintz","year":"1995","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcmg.2017.09.008_bib55","doi-asserted-by":"crossref","first-page":"1704","DOI":"10.1016\/j.amjcard.2008.02.053","article-title":"Impact of stent deployment procedural factors on long-term effectiveness and safety of sirolimus-eluting stents (final results of the multicenter prospective STLLR trial)","volume":"101","author":"Costa","year":"2008","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jcmg.2017.09.008_bib56","unstructured":"Koyama K. A Prospective, Single-Center, Randomized Study to Assess Whether Co-registration of OCT and Angiography Can Reduce Geographic Miss. TCTMD. October 2016. Available at: https:\/\/www.tctmd.com\/slide\/prospective-single-center-randomized-study-assess-whether-co-registration-oct-and-angiography. Accessed March 13,\u00a02017."},{"key":"10.1016\/j.jcmg.2017.09.008_bib57","doi-asserted-by":"crossref","first-page":"855","DOI":"10.4244\/EIJV8I7A129","article-title":"Comparison of intravascular ultrasound versus angiography-guided drug-eluting stent implantation: a meta-analysis of one randomised trial and ten observational studies involving 19,619 patients","volume":"8","author":"Zhang","year":"2012","journal-title":"EuroIntervention"},{"key":"10.1016\/j.jcmg.2017.09.008_bib58","doi-asserted-by":"crossref","first-page":"1338","DOI":"10.1016\/j.amjcard.2013.12.043","article-title":"Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients enrolled in three randomized trials and 14 observational studies","volume":"113","author":"Ahn","year":"2014","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jcmg.2017.09.008_bib59","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1186\/s12872-015-0144-8","article-title":"Comparison of intravascular ultrasound guided versus angiography guided drug eluting stent implantation: a systematic review and meta-analysis","volume":"15","author":"Zhang","year":"2015","journal-title":"BMC Cardiovasc Disord"},{"key":"10.1016\/j.jcmg.2017.09.008_bib60","doi-asserted-by":"crossref","first-page":"2155","DOI":"10.1001\/jama.2015.15454","article-title":"Effect of intravascular ultrasound-guided vs angiography-guided everolimus-eluting stent implantation: the IVUS-XPL randomized clinical trial","volume":"314","author":"Hong","year":"2015","journal-title":"JAMA"},{"key":"10.1016\/j.jcmg.2017.09.008_bib61","doi-asserted-by":"crossref","first-page":"e003700","DOI":"10.1161\/CIRCINTERVENTIONS.116.003700","article-title":"Outcomes with intravascular ultrasound-guided stent implantation: a meta-analysis of randomized trials in the era of drug-eluting stents","volume":"9","author":"Elgendy","year":"2016","journal-title":"Circ Cardiovasc Interv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib62","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1016\/j.ijcard.2016.04.154","article-title":"Intravascular ultrasound-guided drug-eluting stent implantation: an updated meta-analysis of randomized control trials and observational studies","volume":"216","author":"Steinvil","year":"2016","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.jcmg.2017.09.008_bib63","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.ahj.2016.10.008","article-title":"Intravascular ultrasound-guided vs angiography-guided drug-eluting stent implantation in complex coronary lesions: meta-analysis of randomized trials","volume":"185","author":"Bavishi","year":"2017","journal-title":"Am Heart J"},{"key":"10.1016\/j.jcmg.2017.09.008_bib64","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1016\/j.jcin.2013.09.014","article-title":"Clinical impact of intravascular ultrasound guidance in drug-eluting stent implantation for unprotected left main coronary disease: pooled analysis at the patient-level of 4 registries","volume":"7","author":"de la Torre Hernandez","year":"2014","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib65","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1161\/CIRCINTERVENTIONS.108.799494","article-title":"Impact of intravascular ultrasound guidance on long-term mortality in stenting for unprotected left main coronary artery stenosis","volume":"2","author":"Park","year":"2009","journal-title":"Circ Cardiovasc Interv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib66","doi-asserted-by":"crossref","first-page":"e004813","DOI":"10.1161\/CIRCINTERVENTIONS.116.004813","article-title":"Intravascular ultrasound guidance is associated with better outcome in patients undergoing unprotected left main coronary artery stenting compared with angiography guidance alone","volume":"10","author":"Andell","year":"2017","journal-title":"Circ Cardiovasc Interv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib67","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1007\/s10198-015-0670-4","article-title":"Understanding the economic impact of intravascular ultrasound (IVUS)","volume":"17","author":"Alberti","year":"2016","journal-title":"Eur J Health Econ"},{"key":"10.1016\/j.jcmg.2017.09.008_bib68","doi-asserted-by":"crossref","first-page":"1715","DOI":"10.1016\/j.jcin.2015.07.026","article-title":"Relation between bioresorbable scaffold sizing using QCA-Dmax and clinical outcomes at 1 year in 1,232 patients from 3 study cohorts (ABSORB Cohort B, ABSORB EXTEND, and ABSORB II)","volume":"8","author":"Ishibashi","year":"2015","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib69","doi-asserted-by":"crossref","first-page":"921","DOI":"10.1016\/j.jacc.2015.12.019","article-title":"Bioresorbable coronary scaffold thrombosis","volume":"67","author":"Puricel","year":"2016","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcmg.2017.09.008_bib70","unstructured":"Ellis SG. Everolimus-Eluting Bioresorbable Vascular Scaffolds in Patients with Coronary Artery Disease: ABSORB III Trial 2-Year Results. TCTMD. March 2017. Available at: https:\/\/www.tctmd.com\/slide\/everolimus-eluting-bioresorbable-vascular-scaffolds-patients-coronary-artery-disease-absorb. Accessed July 30,\u00a02017."},{"key":"10.1016\/j.jcmg.2017.09.008_bib71","doi-asserted-by":"crossref","first-page":"1730","DOI":"10.4244\/EIJ-D-16-00247","article-title":"Clinical outcomes of a real-world cohort following bioresorbable vascular scaffold implantation utilising an optimised implantation strategy","volume":"12","author":"Tanaka","year":"2017","journal-title":"EuroIntervention"},{"key":"10.1016\/j.jcmg.2017.09.008_bib72","doi-asserted-by":"crossref","first-page":"1172","DOI":"10.1093\/eurheartj\/ehn553","article-title":"Late\u00a0stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis","volume":"31","author":"Hassan","year":"2010","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jcmg.2017.09.008_bib73","doi-asserted-by":"crossref","first-page":"1255","DOI":"10.1007\/s10554-013-0223-9","article-title":"Optical coherence tomography derived cut-off value of uncovered stent struts to predict adverse clinical outcomes after drug-eluting stent implantation","volume":"29","author":"Won","year":"2013","journal-title":"Int J Cardiovasc Imaging"},{"key":"10.1016\/j.jcmg.2017.09.008_bib74","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.jcin.2011.10.013","article-title":"Clinical presentation, management, and outcomes of angiographically documented early, later, and very late stent thrombosis","volume":"5","author":"Armstrong","year":"2012","journal-title":"J\u00a0Am Coll Cardiol Intv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib75","doi-asserted-by":"crossref","first-page":"1747","DOI":"10.4244\/EIJ-D-16-00471","article-title":"Possible mechanical causes of scaffold thrombosis: insights from case reports with intracoronary imaging","volume":"12","author":"Sotomi","year":"2017","journal-title":"EuroIntervention"},{"key":"10.1016\/j.jcmg.2017.09.008_bib76","first-page":"494","article-title":"Hybrid intravascular ultrasound and optical coherence tomography catheter for imaging of coronary atherosclerosis","volume":"81","author":"Li","year":"2013","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.jcmg.2017.09.008_bib77","unstructured":"Ramalingam R. Development and Testing of a Novel and Smart Hybrid IVUS-OCT Sensor for Intravascular Ultrasound. Available at: https:\/\/events.eventact.com\/ProgramView\/ViewAbstract.aspx?Abst=131952&Code=1872739 Accessed on July 31,\u00a02017."}],"container-title":["JACC: Cardiovascular Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1936878X1730918X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1936878X1730918X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T17:44:37Z","timestamp":1761846277000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1936878X1730918X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,12]]},"references-count":77,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2017,12]]}},"alternative-id":["S1936878X1730918X"],"URL":"https:\/\/doi.org\/10.1016\/j.jcmg.2017.09.008","relation":{},"ISSN":["1936-878X"],"issn-type":[{"value":"1936-878X","type":"print"}],"subject":[],"published":{"date-parts":[[2017,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"IVUS-Guided Versus OCT-Guided Coronary\u00a0Stent Implantation","name":"articletitle","label":"Article Title"},{"value":"JACC: Cardiovascular Imaging","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcmg.2017.09.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 by the American College of Cardiology Foundation. Published by Elsevier.","name":"copyright","label":"Copyright"}]}}