{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T02:44:54Z","timestamp":1785725094821,"version":"3.56.0"},"reference-count":32,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2021,2,1]],"date-time":"2021-02-01T00:00:00Z","timestamp":1612137600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,2,1]],"date-time":"2021-02-01T00:00:00Z","timestamp":1612137600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2022,2,1]],"date-time":"2022-02-01T00:00:00Z","timestamp":1643673600000},"content-version":"vor","delay-in-days":365,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/501100004663","name":"Ministry of Science and Technology, Taiwan","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100004663","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jacc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JACC: Cardiovascular Imaging"],"published-print":{"date-parts":[[2021,2]]},"DOI":"10.1016\/j.jcmg.2020.08.034","type":"journal-article","created":{"date-parts":[[2020,11,19]],"date-time":"2020-11-19T06:55:31Z","timestamp":1605768931000},"page":"335-345","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":44,"title":["Artificial Intelligence Aids Cardiac Image Quality Assessment for Improving Precision in Strain Measurements"],"prefix":"10.1016","volume":"14","author":[{"given":"Kuan-Chih","family":"Huang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chiun-Sheng","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mao-Yuan","family":"Su","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chung-Lieh","family":"Hung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi-Chin","family":"Ethan Tu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lung-Chun","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juey-Jen","family":"Hwang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jcmg.2020.08.034_bib1","first-page":"87","article-title":"Left ventricular dysfunction in cancer treatment","volume":"6","author":"Kenigsberg","year":"2018","journal-title":"J\u00a0Am Coll Cardiol HF"},{"key":"10.1016\/j.jcmg.2020.08.034_bib2","doi-asserted-by":"crossref","first-page":"1030","DOI":"10.1200\/JCO.2015.64.5515","article-title":"Cardiac surveillance guidelines for trastuzumab-containing therapy in early-stage breast cancer: getting to the heart of the Matter","volume":"34","author":"Dang","year":"2016","journal-title":"J\u00a0Clin Oncol"},{"key":"10.1016\/j.jcmg.2020.08.034_bib3","doi-asserted-by":"crossref","first-page":"2751","DOI":"10.1016\/j.jacc.2014.01.073","article-title":"Use of myocardial strain imaging by echocardiography for the early detection of cardiotoxicity in patients during and after cancer chemotherapy: a systematic review","volume":"63","author":"Thavendiranathan","year":"2014","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcmg.2020.08.034_bib4","doi-asserted-by":"crossref","first-page":"1397","DOI":"10.1161\/CIRCULATIONAHA.116.023463","article-title":"Detailed echocardiographic phenotyping in breast cancer patients: associations with ejection fraction decline, recovery, and heart failure symptoms over 3 years of follow-up","volume":"135","author":"Narayan","year":"2017","journal-title":"Circulation"},{"key":"10.1016\/j.jcmg.2020.08.034_bib5","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1016\/j.jcmg.2018.03.019","article-title":"Rationale and design of the strain surveillance of chemotherapy for improving cardiovascular outcomes","volume":"11","author":"Negishi","year":"2018","journal-title":"J\u00a0Am Coll Cardiol Img"},{"key":"10.1016\/j.jcmg.2020.08.034_bib6","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1016\/j.ultrasmedbio.2012.11.021","article-title":"What is the primary source of discordance in strain measurement between vendors: imaging or analysis?","volume":"39","author":"Negishi","year":"2013","journal-title":"Ultrasound Med Biol"},{"key":"10.1016\/j.jcmg.2020.08.034_bib7","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1530\/ERP-17-0047","article-title":"Impact of image quality on reliability of the measurements of left ventricular systolic function and global longitudinal strain in 2D echocardiography","volume":"5","author":"Nagata","year":"2018","journal-title":"Echo Res Pract"},{"key":"10.1016\/j.jcmg.2020.08.034_bib8","first-page":"707","article-title":"Intervendor consistency and reproducibility of left ventricular 2D global and regional strain with 2 different high-end ultrasound systems","volume":"18","author":"Shiino","year":"2017","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"10.1016\/j.jcmg.2020.08.034_bib9","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1016\/j.echo.2017.06.010","article-title":"Left ventricular global strain analysis by two-dimensional speckle-tracking echocardiography: the learning curve","volume":"30","author":"Chan","year":"2017","journal-title":"J\u00a0Am Soc Echocardiogr"},{"key":"10.1016\/j.jcmg.2020.08.034_bib10","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1016\/j.echo.2017.11.018","article-title":"Echocardiography core laboratory reproducibility of cardiac safety assessments in cardio-oncology","volume":"31","author":"Khouri","year":"2018","journal-title":"J\u00a0Am Soc Echocardiogr"},{"key":"10.1016\/j.jcmg.2020.08.034_bib11","doi-asserted-by":"crossref","first-page":"1144","DOI":"10.1016\/j.echo.2016.08.006","article-title":"Critical review of current approaches for echocardiographic reproducibility and reliability assessment in clinical research","volume":"29","author":"Crowley","year":"2016","journal-title":"J\u00a0Am Soc Echocardiogr"},{"key":"10.1016\/j.jcmg.2020.08.034_bib12","doi-asserted-by":"crossref","first-page":"1057","DOI":"10.1007\/s10554-018-1315-3","article-title":"Impact of acquisition and interpretation on total inter-observer variability in echocardiography: results from the quality assurance program of the STAAB cohort study","volume":"34","author":"Morbach","year":"2018","journal-title":"Int J Cardiovasc Imaging"},{"key":"10.1016\/j.jcmg.2020.08.034_bib13","doi-asserted-by":"crossref","first-page":"1623","DOI":"10.1161\/CIRCULATIONAHA.118.034338","article-title":"Fully automated echocardiogram interpretation in clinical practice: feasibility and diagnostic accuracy","volume":"138","author":"Zhang","year":"2018","journal-title":"Circulation"},{"key":"10.1016\/j.jcmg.2020.08.034_bib14","doi-asserted-by":"crossref","first-page":"1221","DOI":"10.1109\/TMI.2017.2690836","article-title":"Automatic quality assessment of echocardiograms using convolutional neural networks: feasibility on the apical four-chamber view","volume":"36","author":"Abdi","year":"2017","journal-title":"IEEE Trans Med Imaging"},{"key":"10.1016\/j.jcmg.2020.08.034_bib15","author":"Huang"},{"key":"10.1016\/j.jcmg.2020.08.034_bib16","author":"Zhou"},{"key":"10.1016\/j.jcmg.2020.08.034_bib17","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1056\/NEJMoa1703643","article-title":"Adjuvant pertuzumab and trastuzumab in early HER2-positive breast cancer","volume":"377","author":"von Minckwitz","year":"2017","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.jcmg.2020.08.034_bib18","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.ejca.2017.05.010","article-title":"Safety and tolerability of subcutaneous trastuzumab for the adjuvant treatment of human epidermal growth factor receptor 2-positive early breast cancer: SafeHer phase III study\u2019s primary analysis of 2573 patients","volume":"82","author":"Gligorov","year":"2017","journal-title":"Eur J Cancer"},{"key":"10.1016\/j.jcmg.2020.08.034_bib19","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/S1470-2045(17)30716-7","article-title":"Neoadjuvant trastuzumab, pertuzumab, and chemotherapy versus trastuzumab emtansine plus pertuzumab in patients with HER2-positive breast cancer (KRISTINE): a randomised, open-label, multicentre, phase 3 trial","volume":"19","author":"Hurvitz","year":"2018","journal-title":"Lancet Oncol"},{"key":"10.1016\/j.jcmg.2020.08.034_bib20","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1016\/j.jcmg.2016.12.025","article-title":"MRI-derived myocardial strain measures in normal subjects","volume":"11","author":"Vo","year":"2018","journal-title":"J\u00a0Am Coll Cardiol Img"},{"key":"10.1016\/j.jcmg.2020.08.034_bib21","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/S0002-9149(98)00826-1","article-title":"Comparison of native and contrast-enhanced harmonic echocardiography for visualization of left ventricular endocardial border","volume":"83","author":"Kasprzak","year":"1999","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.jcmg.2020.08.034_bib22","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1253\/circj.66.494","article-title":"Head-to-head comparison of fundamental, tissue harmonic and contrast harmonic imaging with or without an air-filled contrast agent, levovist, for endocardial border delineation in patients with poor quality images","volume":"66","author":"Yoshitani","year":"2002","journal-title":"Circ J"},{"key":"10.1016\/j.jcmg.2020.08.034_bib23","doi-asserted-by":"crossref","first-page":"1109","DOI":"10.1016\/j.jcmg.2018.03.003","article-title":"Single versus standard multiview assessment of global longitudinal strain for the diagnosis of cardiotoxicity during cancer therapy","volume":"11","author":"Thavendiranathan","year":"2018","journal-title":"J\u00a0Am Coll Cardiol Img"},{"key":"10.1016\/j.jcmg.2020.08.034_bib24","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1016\/j.echo.2015.01.021","article-title":"Intervendor variability of two-dimensional strain using vendor-specific and vendor-independent software","volume":"28","author":"Nagata","year":"2015","journal-title":"J\u00a0Am Soc Echocardiogr"},{"key":"10.1016\/j.jcmg.2020.08.034_bib25","doi-asserted-by":"crossref","first-page":"2768","DOI":"10.1093\/eurheartj\/ehw211","article-title":"2016 ESC position paper on cancer treatments and cardiovascular toxicity developed under the auspices of the ESC Committee for Practice Guidelines: The Task Force for cancer treatments and cardiovascular toxicity of the European Society of Cardiology (ESC)","volume":"37","author":"Zamorano","year":"2016","journal-title":"Eur Heart J"},{"key":"10.1016\/j.jcmg.2020.08.034_bib26","doi-asserted-by":"crossref","first-page":"911","DOI":"10.1016\/j.echo.2014.07.012","article-title":"Expert consensus for multimodality imaging evaluation of adult patients during and after cancer therapy: a report from the American Society of Echocardiography and the European Association of Cardiovascular Imaging","volume":"27","author":"Plana","year":"2014","journal-title":"J\u00a0Am Soc Echocardiogr"},{"key":"10.1016\/j.jcmg.2020.08.034_bib27","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1016\/j.echo.2019.04.001","article-title":"Machine learning-based three-dimensional echocardiographic quantification of right ventricular size and function: validation against cardiac magnetic resonance","volume":"32","author":"Genovese","year":"2019","journal-title":"J\u00a0Am Soc Echocardiogr"},{"key":"10.1016\/j.jcmg.2020.08.034_bib28","doi-asserted-by":"crossref","first-page":"2090","DOI":"10.1016\/j.jcmg.2019.04.018","article-title":"The impact of IAC-Echo accreditation and required quality assurance initiatives on transthoracic echocardiogram interpretation errors","volume":"12","author":"Yang","year":"2019","journal-title":"J\u00a0Am Coll Cardiol Img"},{"key":"10.1016\/j.jcmg.2020.08.034_bib29","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.jacc.2012.09.035","article-title":"Reproducibility of echocardiographic techniques for sequential assessment of left ventricular ejection fraction and volumes","volume":"61","author":"Thavendiranathan","year":"2013","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcmg.2020.08.034_bib30","doi-asserted-by":"crossref","first-page":"2360","DOI":"10.1016\/j.jacc.2018.08.2162","article-title":"Ejection fraction pros and cons: JACC state-of-the-art review","volume":"72","author":"Marwick","year":"2018","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.jcmg.2020.08.034_bib31","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1016\/j.echo.2017.05.018","article-title":"Three-dimensional echocardiographic automated quantification of left heart chamber volumes using an adaptive analytics algorithm: feasibility and impact of image quality in nonselected patients","volume":"30","author":"Medvedofsky","year":"2017","journal-title":"J\u00a0Am Soc Echocardiogr"},{"key":"10.1016\/j.jcmg.2020.08.034_bib32","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1016\/j.jcmg.2019.02.024","article-title":"A\u00a0deep learning approach for assessment of regional wall motion abnormality from echocardiographic images","volume":"13","author":"Kusunose","year":"2020","journal-title":"J\u00a0Am Coll Cardiol Img"}],"container-title":["JACC: Cardiovascular Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1936878X20308858?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1936878X20308858?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T17:51:22Z","timestamp":1761846682000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1936878X20308858"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2]]},"references-count":32,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,2]]}},"alternative-id":["S1936878X20308858"],"URL":"https:\/\/doi.org\/10.1016\/j.jcmg.2020.08.034","relation":{},"ISSN":["1936-878X"],"issn-type":[{"value":"1936-878X","type":"print"}],"subject":[],"published":{"date-parts":[[2021,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Artificial Intelligence Aids Cardiac Image Quality Assessment for Improving Precision in Strain Measurements","name":"articletitle","label":"Article Title"},{"value":"JACC: Cardiovascular Imaging","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcmg.2020.08.034","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 by the American College of Cardiology Foundation. Published by Elsevier.","name":"copyright","label":"Copyright"}]}}