{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T15:48:45Z","timestamp":1790092125251,"version":"4.0.1"},"reference-count":32,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2023,2,1]],"date-time":"2023-02-01T00:00:00Z","timestamp":1675209600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,2,1]],"date-time":"2023-02-01T00:00:00Z","timestamp":1675209600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,2,1]],"date-time":"2024-02-01T00:00:00Z","timestamp":1706745600000},"content-version":"vor","delay-in-days":365,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100000050","name":"National Heart Lung and Blood Institute","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000050","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000968","name":"American Heart Association Inc","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000968","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jacc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JACC: Cardiovascular Imaging"],"published-print":{"date-parts":[[2023,2]]},"DOI":"10.1016\/j.jcmg.2022.09.013","type":"journal-article","created":{"date-parts":[[2022,11,16]],"date-time":"2022-11-16T18:25:11Z","timestamp":1668623111000},"page":"224-235","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":25,"title":["Noninvasive Evaluation of Cardiac\u00a0Chamber Pressures Using Subharmonic-Aided Pressure Estimation\u00a0With Definity Microbubbles"],"prefix":"10.1016","volume":"16","author":[{"given":"Cara","family":"Esposito","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Priscilla","family":"Machado","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maureen E.","family":"McDonald","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael P.","family":"Savage","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Fischman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Praveen","family":"Mehrotra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ira S.","family":"Cohen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"II","given":"Nicholas","family":"Ruggiero","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul","family":"Walinsky","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alec","family":"Vishnevsky","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kristopher","family":"Dickie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marguerite","family":"Davis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Flemming","family":"Forsberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4324-8802","authenticated-orcid":false,"given":"Jaydev K.","family":"Dave","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jcmg.2022.09.013_bib1","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1161\/CIRCULATIONAHA.108.823591","article-title":"Recalibrating the barometer: is it time to take a critical look at noninvasive approaches to measuring filling pressures?","volume":"119","author":"Solomon","year":"2009","journal-title":"Circulation"},{"key":"10.1016\/j.jcmg.2022.09.013_bib2","doi-asserted-by":"crossref","first-page":"245","DOI":"10.2174\/138161209787354203","article-title":"Non-invasive methods and techniques for central blood pressure estimation: procedures, validation, reproducibility and limitations","volume":"15","author":"Papaioannou","year":"2009","journal-title":"Curr Pharm Des"},{"key":"10.1016\/j.jcmg.2022.09.013_bib3","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1148\/radiol.13121769","article-title":"Chronic liver disease: noninvasive subharmonic aided pressure estimation of hepatic venous pressure gradient","volume":"268","author":"Eisenbrey","year":"2013","journal-title":"Radiology"},{"key":"10.1016\/j.jcmg.2022.09.013_bib4","doi-asserted-by":"crossref","first-page":"1784","DOI":"10.1016\/j.ultrasmedbio.2012.06.013","article-title":"Investigating the efficacy of subharmonic aided pressure estimation for portal vein pressures and portal hypertension monitoring","volume":"38","author":"Dave","year":"2012","journal-title":"Ultrasound Med Biol"},{"key":"10.1016\/j.jcmg.2022.09.013_bib5","doi-asserted-by":"crossref","first-page":"2056","DOI":"10.1109\/TUFFC.2011.2056","article-title":"Noninvasive estimation of dynamic pressures in\u00a0vitro and in\u00a0vivo using the subharmonic response from microbubbles","volume":"58","author":"Dave","year":"2011","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"key":"10.1016\/j.jcmg.2022.09.013_bib6","doi-asserted-by":"crossref","first-page":"2718","DOI":"10.1016\/j.ultrasmedbio.2017.07.009","article-title":"Noninvasive intracardiac pressure measurements using subharmonic aided pressure estimation: proof of concept in humans","volume":"43","author":"Dave","year":"2017","journal-title":"Ultrasound Med Biol"},{"key":"10.1016\/j.jcmg.2022.09.013_bib7","first-page":"3","article-title":"Effect of pulse shaping on subharmonic aided pressure estimation in\u00a0vitro and in\u00a0vivo","volume":"36","author":"Gupta","year":"2017","journal-title":"J\u00a0Med Ultrasound"},{"key":"10.1016\/j.jcmg.2022.09.013_bib8","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1148\/radiol.2017161683","article-title":"Monitoring neoadjuvant chemotherapy for breast cancer by using three-dimensional subharmonic aided pressure estimation and imaging with US contrast agents: preliminary experience","volume":"285","author":"Nam","year":"2017","journal-title":"Radiology"},{"key":"10.1016\/j.jcmg.2022.09.013_bib9","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/S0301-5629(98)00163-X","article-title":"Pressure dependence of subharmonic signals from contrast microbubbles","volume":"25","author":"Shi","year":"1999","journal-title":"Ultrasound Med Biol"},{"key":"10.1016\/j.jcmg.2022.09.013_bib10","series-title":"Handbook of Polymer Applications in Medicine and Medical Devices","first-page":"253","article-title":"Microbubble applications in biomedicine","author":"Dastghey","year":"2014"},{"key":"10.1016\/j.jcmg.2022.09.013_bib11","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1109\/TUFFC.2019.2948759","article-title":"Optimal control of SonoVue microbubbles to estimate hydrostatic pressure","volume":"67","author":"Nio","year":"2020","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"key":"10.1016\/j.jcmg.2022.09.013_bib12","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1177\/016173461103300301","article-title":"Subharmonic contrast microbubble signals for noninvasive pressure estimation under static and dynamic flow conditions","volume":"33","author":"Halldorsdottir","year":"2011","journal-title":"Ultrason Imaging"},{"key":"10.1016\/j.jcmg.2022.09.013_bib13","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1109\/TUFFC.2020.3016264","article-title":"Developing an interface and investigating optimal parameters for real-time intra-cardiac subharmonic aided pressure estimation","volume":"68","author":"Esposito","year":"2021","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"key":"10.1016\/j.jcmg.2022.09.013_bib14","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1016\/j.urology.2019.12.025","article-title":"Transrectal subharmonic ultrasound imaging for prostate cancer detection","volume":"138","author":"Gupta","year":"2020","journal-title":"Urology"},{"key":"10.1016\/j.jcmg.2022.09.013_bib15","doi-asserted-by":"crossref","first-page":"880","DOI":"10.1016\/j.ultras.2012.12.010","article-title":"On the implementation of an automated acoustic output optimization algorithm for subharmonic aided pressure estimation","volume":"53","author":"Dave","year":"2013","journal-title":"Ultrasonics"},{"key":"10.1016\/j.jcmg.2022.09.013_bib16","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1093\/ajh\/hpac010","article-title":"Comparing central aortic pressures obtained using a sphygmocor device to pressures obtained using a pressure catheter","volume":"35","author":"Esposito","year":"2022","journal-title":"Am J Hypertens"},{"key":"10.1016\/j.jcmg.2022.09.013_bib17","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.jcmg.2011.08.017","article-title":"Noninvasive LV pressure estimation using subharmonic emissions from microbubbles","volume":"5","author":"Dave","year":"2012","journal-title":"J\u00a0Am Coll Cardiol Img"},{"key":"10.1016\/j.jcmg.2022.09.013_bib18","first-page":"307","article-title":"Measurement in medicine: the analysis of method comparison studies","volume":"32","author":"Altman","year":"1983","journal-title":"J\u00a0R Stat Soc Series D (The Statistician)"},{"key":"10.1016\/j.jcmg.2022.09.013_bib19","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1016\/j.echo.2008.07.019","article-title":"The safety of Definity and Option for ultrasound image enhancement: a retrospective analysis of 78,383 administered contrast doses","volume":"21","author":"Wei","year":"2008","journal-title":"J\u00a0Am Soc Echocardiogr"},{"key":"10.1016\/j.jcmg.2022.09.013_bib20","doi-asserted-by":"crossref","first-page":"790","DOI":"10.1016\/j.echo.2012.04.002","article-title":"CaRES (Contrast Echocardiography Registry for Safety Surveillance): a prospective multicenter study to evaluate the safety of the ultrasound contrast agent Definity in clinical practice","volume":"25","author":"Weiss","year":"2012","journal-title":"J\u00a0Am Soc Echocardiogr"},{"key":"10.1016\/j.jcmg.2022.09.013_bib21","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCIMAGING.116.005459","article-title":"Safety with echocardiographic contrast agents","volume":"10","author":"Muskula","year":"2017","journal-title":"Circ Cardiovasc Imaging"},{"key":"10.1016\/j.jcmg.2022.09.013_bib22","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1016\/j.echo.2021.05.002","article-title":"Expert consensus statement from the American Society of Echocardiography on hypersensitivity reactions to ultrasound enhancing agents in patients with allergy to polyethylene glycol","volume":"34","author":"Lindner","year":"2021","journal-title":"J\u00a0Am Soc Echocardiogr"},{"key":"10.1016\/j.jcmg.2022.09.013_bib23","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1001\/jama.1996.03540110043030","article-title":"The effectiveness of right heart catheterization in the initial care of critically ill patients","volume":"276","author":"Connors","year":"1996","journal-title":"JAMA"},{"key":"10.1016\/j.jcmg.2022.09.013_bib24","doi-asserted-by":"crossref","first-page":"1664","DOI":"10.1001\/jama.294.13.1664","article-title":"Impact of the pulmonary artery catheter in critically ill patients meta-analysis of randomized clinical trials","volume":"294","author":"Shah","year":"2005","journal-title":"JAMA"},{"key":"10.1016\/j.jcmg.2022.09.013_bib25","doi-asserted-by":"crossref","first-page":"H126","DOI":"10.1152\/ajpheart.00560.2011","article-title":"Subharmonic microbubble emissions for noninvasively tracking right ventricular pressures","volume":"302","author":"Dave","year":"2012","journal-title":"Am J Physiol Heart Circ"},{"issue":"2","key":"10.1016\/j.jcmg.2022.09.013_bib26","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1109\/TBME.1977.326112","article-title":"A\u00a0new noninvasive technique for cardiac pressure measurement: resonant scattering of ultrasound from bubbles","volume":"24","author":"Fairbank","year":"1977","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1016\/j.jcmg.2022.09.013_bib27","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1007\/BF02443844","article-title":"A\u00a0new approach to noninvasive manometry: interaction between ultrasound and bubbles","volume":"19","author":"H\u00f6k","year":"1981","journal-title":"Med Biol Eng Comput"},{"key":"10.1016\/j.jcmg.2022.09.013_bib28","unstructured":"Miwa H. Pressure measuring system with ultrasonic wave. In: Patent 4483345 United States of America 1984: Fujitsu Limited; Filed: August 4,\u00a01982."},{"key":"10.1016\/j.jcmg.2022.09.013_bib29","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/0041-624X(86)90004-1","article-title":"Fluid pressure measurement using bubbles insonified by two frequencies","volume":"24","author":"Shankar","year":"1986","journal-title":"Ultrasonics"},{"key":"10.1016\/j.jcmg.2022.09.013_bib30","doi-asserted-by":"crossref","first-page":"1407","DOI":"10.1016\/S0301-5629(99)00109-X","article-title":"Noninvasive measurement of the hydrostatic pressure in a fluid-filled cavity based on the disappearance time of micrometer-sized free gas bubbles","volume":"25","author":"Bouakaz","year":"1999","journal-title":"Ultrasound Med Biol"},{"issue":"166","key":"10.1016\/j.jcmg.2022.09.013_bib31","article-title":"Contrast-enhanced subharmonic aided pressure estimation (SHAPE) using ultrasound imaging with a focus on identifying portal hypertension","author":"Forsberg","year":"2020","journal-title":"J\u00a0Vis Exp"},{"issue":"4","key":"10.1016\/j.jcmg.2022.09.013_bib32","doi-asserted-by":"crossref","first-page":"2544","DOI":"10.1378\/chest.128.4.2544","article-title":"Comparative value of tissue Doppler imaging and m-mode color Doppler mitral flow propagation velocity for the evaluation of left ventricular filling pressure","volume":"128","author":"Kidawa","year":"2005","journal-title":"Chest"}],"container-title":["JACC: Cardiovascular Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1936878X22005575?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1936878X22005575?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T17:53:48Z","timestamp":1761846828000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1936878X22005575"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2]]},"references-count":32,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2023,2]]}},"alternative-id":["S1936878X22005575"],"URL":"https:\/\/doi.org\/10.1016\/j.jcmg.2022.09.013","relation":{},"ISSN":["1936-878X"],"issn-type":[{"value":"1936-878X","type":"print"}],"subject":[],"published":{"date-parts":[[2023,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Noninvasive Evaluation of Cardiac\u00a0Chamber Pressures Using Subharmonic-Aided Pressure Estimation\u00a0With Definity Microbubbles","name":"articletitle","label":"Article Title"},{"value":"JACC: Cardiovascular Imaging","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcmg.2022.09.013","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 by the American College of Cardiology Foundation. Published by Elsevier.","name":"copyright","label":"Copyright"}]}}