{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,27]],"date-time":"2026-09-27T04:30:15Z","timestamp":1790483415017,"version":"4.1.0"},"reference-count":20,"publisher":"Elsevier BV","issue":"10","license":[{"start":{"date-parts":[[2017,10,1]],"date-time":"2017-10-01T00:00:00Z","timestamp":1506816000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2017,10,1]],"date-time":"2017-10-01T00:00:00Z","timestamp":1506816000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Cranio-Maxillofacial Surgery"],"published-print":{"date-parts":[[2017,10]]},"DOI":"10.1016\/j.jcms.2017.07.006","type":"journal-article","created":{"date-parts":[[2017,7,25]],"date-time":"2017-07-25T16:06:00Z","timestamp":1500998760000},"page":"1662-1670","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":38,"title":["Accuracy and reproducibility of the DAVID SLS-2 scanner in three-dimensional facial imaging"],"prefix":"10.1016","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1216-1170","authenticated-orcid":false,"given":"Jesper Jared","family":"Secher","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tron Andre","family":"Darvann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Else Marie","family":"Pinholt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jcms.2017.07.006_bib1","series-title":"Silicio Dentistry\u2500The evolution of computational oral health science","first-page":"160","article-title":"Landmarker: a VTK-based tool for landmarking of polygonal surfaces","author":"Darvann","year":"2008"},{"issue":"2","key":"10.1016\/j.jcms.2017.07.006_bib2","doi-asserted-by":"crossref","first-page":"e307","DOI":"10.1097\/GOX.0000000000000184","article-title":"Current status of surgical planning for orthognathic surgery: traditional methods versus 3D surgical planning","volume":"3","author":"Hammoudeh","year":"2015","journal-title":"Plast Reconstr Surg Glob Open"},{"issue":"1","key":"10.1016\/j.jcms.2017.07.006_bib3","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1597\/14-142","article-title":"A\u00a0pilot study on the influence of facial expression on measurements in three-dimensional digital surfaces of the face in infants with cleft lip and palate","volume":"53","author":"Hermann","year":"2016","journal-title":"Cleft Palate Craniofacial J"},{"issue":"3","key":"10.1016\/j.jcms.2017.07.006_bib4","doi-asserted-by":"crossref","first-page":"105","DOI":"10.4041\/kjod.2015.45.3.105","article-title":"Accuracy and precision of integumental linear dimensions in a three-dimensional facial imaging system","volume":"45","author":"Kim","year":"2015","journal-title":"Korean J Orthod"},{"issue":"10","key":"10.1016\/j.jcms.2017.07.006_bib5","doi-asserted-by":"crossref","first-page":"2391","DOI":"10.1016\/j.joms.2009.10.017","article-title":"Registration of 3-dimensional facial photographs for clinical use","volume":"68","author":"Maal","year":"2010","journal-title":"J\u00a0Oral Maxillofac Surg"},{"issue":"10","key":"10.1016\/j.jcms.2017.07.006_bib6","doi-asserted-by":"crossref","first-page":"1994","DOI":"10.1016\/j.jcms.2015.08.007","article-title":"A\u00a0new 3D approach to evaluate facial profile changes following BSSO","volume":"43","author":"Meulstee","year":"2015","journal-title":"J\u00a0Craniomaxillofacial Surg"},{"issue":"10","key":"10.1016\/j.jcms.2017.07.006_bib7","doi-asserted-by":"crossref","first-page":"1719","DOI":"10.1016\/j.jcms.2016.08.008","article-title":"Evaluation of the accuracy of a mobile and a stationary system for three-dimensional facial scanning","volume":"44","author":"Modabber","year":"2016","journal-title":"J\u00a0Craniomaxillofacial Surg"},{"issue":"9","key":"10.1016\/j.jcms.2017.07.006_bib8","doi-asserted-by":"crossref","first-page":"1798","DOI":"10.1016\/j.jcms.2015.08.017","article-title":"The 3dMD photogrammetric photo system in cranio-maxillofacial surgery: validation of interexaminer variations and perceptions","volume":"43","author":"Nord","year":"2015","journal-title":"J\u00a0Craniomaxillofacial Surg"},{"issue":"4","key":"10.1016\/j.jcms.2017.07.006_bib9","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1016\/j.jcms.2015.03.003","article-title":"Measured symmetry of facial 3D shape and perceived facial symmetry and attractiveness before and after orthognathic surgery","volume":"43","author":"Ostwald","year":"2015","journal-title":"J\u00a0Craniomaxillofacial Surg"},{"issue":"7","key":"10.1016\/j.jcms.2017.07.006_bib10","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1016\/j.ijom.2011.02.015","article-title":"3D evaluation of postoperative swelling using two different cooling methods following orthognathic surgery: a randomised observer blind prospective pilot study","volume":"40","author":"Rana","year":"2011","journal-title":"Int J Oral Maxillofacial Surg"},{"issue":"3","key":"10.1016\/j.jcms.2017.07.006_bib11","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/j.jcms.2017.01.002","article-title":"Quantifying the effect of corrective surgery for trigonocephaly: a non-invasive, non-ionizing method using three-dimensional handheld scanning and statistical shape modelling","volume":"45","author":"Rodriguez-Florez","year":"2017","journal-title":"J\u00a0Craniomaxillofacial Surg"},{"issue":"8","key":"10.1016\/j.jcms.2017.07.006_bib12","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1109\/42.796284","article-title":"Nonrigid registration using free-form deformations: application to breast MR images","volume":"18","author":"Rueckert","year":"1999","journal-title":"IEEE Trans Med Imaging"},{"issue":"8","key":"10.1016\/j.jcms.2017.07.006_bib13","doi-asserted-by":"crossref","first-page":"1014","DOI":"10.1109\/TMI.2003.815865","article-title":"Automatic construction of 3-D statistical deformation models of the brain using nonrigid registration","volume":"22","author":"Rueckert","year":"2003","journal-title":"IEEE Trans Med Imaging"},{"key":"10.1016\/j.jcms.2017.07.006_bib14","series-title":"The design and implementation of an object-oriented toolkit for 3D graphics and visualization","author":"Scroeder","year":"1996"},{"key":"10.1016\/j.jcms.2017.07.006_bib15","series-title":"Biomedical image analysis, 1994, proceedings of the IEEE workshop","article-title":"Matching 3-D anatomical surfaces with non-rigid deformations using octree-splines","author":"Szeliski","year":"1994"},{"issue":"3","key":"10.1016\/j.jcms.2017.07.006_bib16","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1097\/00001665-200605000-00015","article-title":"Anthropometric precision and accuracy of digital three-dimensional photogrammetry: comparing the Genex and 3dMD imaging systems with one another and with direct anthropometry","volume":"17","author":"Weinberg","year":"2006","journal-title":"J\u00a0Craniofac Surg"},{"issue":"3","key":"10.1016\/j.jcms.2017.07.006_bib17","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1597\/06-175","article-title":"Validity and reliability of craniofacial anthropometric measurement of 3D digital photogrammetric images","volume":"45","author":"Wong","year":"2008","journal-title":"Cleft Palate Craniofac J"},{"issue":"3","key":"10.1016\/j.jcms.2017.07.006_bib18","doi-asserted-by":"crossref","first-page":"213","DOI":"10.11607\/ijp.4397","article-title":"Evaluation of the accuracy, reliability, and reproducibility of two different 3D face-scanning systems","volume":"29","author":"Ye","year":"2016","journal-title":"Int J Prosthodont"},{"issue":"2","key":"10.1016\/j.jcms.2017.07.006_bib19","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1007\/BF01427149","article-title":"Iterative point matching for registration of free-form curves and surfaces","volume":"13","author":"Zhang","year":"1994","journal-title":"Int J Comput Vis"},{"issue":"5","key":"10.1016\/j.jcms.2017.07.006_bib20","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1055\/s-0035-1565010","article-title":"Computer-designed splints for surgical transfer of 3D orthognathic planning","volume":"31","author":"Zinser","year":"2015","journal-title":"Facial Plast Surg"}],"container-title":["Journal of Cranio-Maxillofacial Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1010518217302445?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1010518217302445?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,19]],"date-time":"2025-10-19T14:37:16Z","timestamp":1760884636000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1010518217302445"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,10]]},"references-count":20,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2017,10]]}},"alternative-id":["S1010518217302445"],"URL":"https:\/\/doi.org\/10.1016\/j.jcms.2017.07.006","relation":{},"ISSN":["1010-5182"],"issn-type":[{"value":"1010-5182","type":"print"}],"subject":[],"published":{"date-parts":[[2017,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Accuracy and reproducibility of the DAVID SLS-2 scanner in three-dimensional facial imaging","name":"articletitle","label":"Article Title"},{"value":"Journal of Cranio-Maxillofacial Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcms.2017.07.006","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Published by Elsevier Ltd on behalf of European Association for Cranio-Maxillo-Facial Surgery.","name":"copyright","label":"Copyright"}]}}