{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T13:26:57Z","timestamp":1762867617997,"version":"build-2065373602"},"reference-count":11,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Cranio-Maxillofacial Surgery"],"published-print":{"date-parts":[[2019,1]]},"DOI":"10.1016\/j.jcms.2018.11.004","type":"journal-article","created":{"date-parts":[[2018,11,12]],"date-time":"2018-11-12T18:48:31Z","timestamp":1542048511000},"page":"99-105","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":14,"title":["An in-vitro evaluation of a novel design of miniplate for fixation of fracture segments in the transition zone of parasymphysis-body region of mandible using finite element analysis"],"prefix":"10.1016","volume":"47","author":[{"given":"Abhay","family":"Datarkar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shikha","family":"Tayal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abhishek","family":"Thote","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manlio","family":"Galie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"10","key":"10.1016\/j.jcms.2018.11.004_bib1","doi-asserted-by":"crossref","first-page":"1691","DOI":"10.1097\/00005537-200110000-00004","article-title":"5196 mandible fractures among 4381 active duty army soldiers, 1980 to 1998","volume":"111","author":"Boole","year":"2001","journal-title":"Laryngoscope"},{"issue":"2","key":"10.1016\/j.jcms.2018.11.004_bib6","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/0266-4356(85)90057-9","article-title":"Small plate osteosynthesis of mandibular fractures","volume":"23","author":"Cawood","year":"1985","journal-title":"Br J Oral Maxillofac Surg"},{"key":"10.1016\/j.jcms.2018.11.004_bib5","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/S0301-0503(78)80062-9","article-title":"Mandibular osteosynthesis by miniature screwed plates via a buccal approach","volume":"6","author":"Champy","year":"1978","journal-title":"J\u00a0Maxillofac Surg"},{"year":"2007","series-title":"Concepts and applications of finite element analysis","author":"Cook","key":"10.1016\/j.jcms.2018.11.004_bib11"},{"issue":"3","key":"10.1016\/j.jcms.2018.11.004_bib4","doi-asserted-by":"crossref","first-page":"e21","DOI":"10.1016\/j.tripleo.2009.11.003","article-title":"A\u00a0biomechanical analysis of titanium miniplates used for treatment of mandibular symphyseal fractures with the finite element method","volume":"109","author":"Ji","year":"2010","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endodontol"},{"issue":"6","key":"10.1016\/j.jcms.2018.11.004_bib10","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.tripleo.2006.12.016","article-title":"Evaluation of different miniplates in fixation of fractured human mandible with the finite element method","volume":"103","author":"Korkmaz","year":"2007","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endodontol"},{"issue":"5","key":"10.1016\/j.jcms.2018.11.004_bib8","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1115\/1.2244575","article-title":"Comparison of plate\u2013screw systems used in mandibular fracture reduction: finite element analysis","volume":"128","author":"Lovald","year":"2006","journal-title":"J\u00a0Biomech Eng"},{"issue":"10","key":"10.1016\/j.jcms.2018.11.004_bib2","doi-asserted-by":"crossref","first-page":"2012","DOI":"10.1016\/j.joms.2008.06.013","article-title":"A\u00a0biomechanical evaluation of plating techniques used for reconstructing mandibular symphysis\/parasymphysis fractures","volume":"66","author":"Madsen","year":"2008","journal-title":"J\u00a0Oral Maxillofac Surg"},{"issue":"3","key":"10.1016\/j.jcms.2018.11.004_bib9","first-page":"246","article-title":"Three-dimensional model of the human craniofacial skeleton: method and preliminary results using finite element analysis","volume":"10","author":"Tanne","year":"1988","journal-title":"J\u00a0Biomed Eng"},{"issue":"6","key":"10.1016\/j.jcms.2018.11.004_bib7","doi-asserted-by":"crossref","first-page":"678","DOI":"10.1067\/moe.2002.126451","article-title":"A\u00a03-dimensional finite-element analysis investigating the biomechanical behavior of the mandible and plate osteosynthesis in cases of fractures of the condylar process","volume":"94","author":"Wagner","year":"2002","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endodontol"},{"issue":"4","key":"10.1016\/j.jcms.2018.11.004_bib3","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1016\/j.ijom.2009.11.003","article-title":"Biomechanics of mandibular reconstruction: a review","volume":"39","author":"Wong","year":"2010","journal-title":"Int J Oral Maxillofac Surg"}],"container-title":["Journal of Cranio-Maxillofacial Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1010518218302385?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1010518218302385?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,19]],"date-time":"2025-10-19T14:41:16Z","timestamp":1760884876000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1010518218302385"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,1]]},"references-count":11,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,1]]}},"alternative-id":["S1010518218302385"],"URL":"https:\/\/doi.org\/10.1016\/j.jcms.2018.11.004","relation":{},"ISSN":["1010-5182"],"issn-type":[{"type":"print","value":"1010-5182"}],"subject":[],"published":{"date-parts":[[2019,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"An in-vitro evaluation of a novel design of miniplate for fixation of fracture segments in the transition zone of parasymphysis-body region of mandible using finite element analysis","name":"articletitle","label":"Article Title"},{"value":"Journal of Cranio-Maxillofacial Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcms.2018.11.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}