{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T22:31:16Z","timestamp":1782513076592,"version":"3.54.5"},"reference-count":39,"publisher":"Elsevier BV","issue":"8","license":[{"start":{"date-parts":[[2019,8,1]],"date-time":"2019-08-01T00:00:00Z","timestamp":1564617600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,8,1]],"date-time":"2019-08-01T00:00:00Z","timestamp":1564617600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2020,7,30]],"date-time":"2020-07-30T00:00:00Z","timestamp":1596067200000},"content-version":"am","delay-in-days":364,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100009592","name":"Beijing Municipal Science and Technology Commission","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100009592","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Cranio-Maxillofacial Surgery"],"published-print":{"date-parts":[[2019,8]]},"DOI":"10.1016\/j.jcms.2019.03.019","type":"journal-article","created":{"date-parts":[[2019,3,25]],"date-time":"2019-03-25T21:56:17Z","timestamp":1553550977000},"page":"1216-1221","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":26,"title":["Accuracy of a chairside fused deposition modeling 3D-printed single-tooth surgical template for implant placement: An in\u00a0vitro comparison with a light cured template"],"prefix":"10.1016","volume":"47","author":[{"given":"Yao","family":"Sun","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qian","family":"Ding","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lin","family":"Tang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lei","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuchun","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qiufei","family":"Xie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.jcms.2019.03.019_bib1","doi-asserted-by":"crossref","first-page":"190","DOI":"10.11607\/jomi.2691","article-title":"Implant positioning errors in freehand and computer-aided placement methods: a single-blind clinical comparative study","volume":"28","author":"Arisan","year":"2013","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"1","key":"10.1016\/j.jcms.2019.03.019_bib2","doi-asserted-by":"crossref","first-page":"92","DOI":"10.11607\/jomi.5004","article-title":"Implant placement accuracy using dynamic navigation","volume":"32","author":"Block","year":"2017","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"9","key":"10.1016\/j.jcms.2019.03.019_bib3","doi-asserted-by":"crossref","first-page":"E1578","DOI":"10.3390\/ma11091578","article-title":"A\u00a0feasibility study of processing polydimethylsiloxane(-)sodium carboxymethylcellulose composites by a low-cost fused deposition modeling 3D-printer","volume":"11","author":"Calcagnile","year":"2018","journal-title":"Materials (Basel)"},{"issue":"3","key":"10.1016\/j.jcms.2019.03.019_bib4","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1111\/cid.12120","article-title":"The influence of the tolerance between mechanical components on the accuracy of implants inserted with a stereolithographic surgical guide: a retrospective clinical study","volume":"17","author":"Cassetta","year":"2015","journal-title":"Clin Implant Dent Relat Res"},{"issue":"2","key":"10.1016\/j.jcms.2019.03.019_bib5","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1016\/j.ijom.2012.06.010","article-title":"The intrinsic error of a stereolithographic surgical template in implant guided surgery","volume":"42","author":"Cassetta","year":"2013","journal-title":"Int J Oral Maxillofac Surg"},{"key":"10.1016\/j.jcms.2019.03.019_bib6","doi-asserted-by":"crossref","first-page":"19207","DOI":"10.1038\/srep19207","article-title":"Application of FDM three-dimensional printing technology in the digital manufacture of custom edentulous mandible trays","volume":"6","author":"Chen","year":"2016","journal-title":"Sci Rep"},{"issue":"4","key":"10.1016\/j.jcms.2019.03.019_bib7","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1016\/S0022-3913(13)60053-0","article-title":"Impact of operator experience on the accuracy of implant placement with stereolithographic surgical templates: an in\u00a0vitro study","volume":"109","author":"Cushen","year":"2013","journal-title":"J\u00a0Prosthet Dent"},{"issue":"6","key":"10.1016\/j.jcms.2019.03.019_bib8","first-page":"342","article-title":"Quantitative evaluation of printing accuracy and tissue surface adaptation of mandibular complete denture polylactic acid pattern fabricated by fused deposition modeling technology","volume":"52","author":"Deng","year":"2017","journal-title":"Zhonghua Kou Qiang Yi Xue Za Zhi"},{"issue":"1","key":"10.1016\/j.jcms.2019.03.019_bib9","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1111\/prd.12175","article-title":"Current state of the art of computer-guided implant surgery","volume":"73","author":"D'Haese","year":"2017","journal-title":"Periodontol 2000"},{"issue":"3","key":"10.1016\/j.jcms.2019.03.019_bib10","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1111\/j.1708-8208.2010.00275.x","article-title":"Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature","volume":"14","author":"D'Haese","year":"2012","journal-title":"Clin Implant Dent Relat Res"},{"issue":"1","key":"10.1016\/j.jcms.2019.03.019_bib11","first-page":"128","article-title":"Accuracy of a newly developed open-source system for dental implant planning","volume":"27","author":"Dreiseidler","year":"2012","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"8","key":"10.1016\/j.jcms.2019.03.019_bib12","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1016\/j.bjoms.2008.03.019","article-title":"Geometric accuracy of digital volume tomography and conventional computed tomography","volume":"46","author":"Eggers","year":"2008","journal-title":"Br J Oral Maxillofac Surg"},{"issue":"1","key":"10.1016\/j.jcms.2019.03.019_bib13","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1108\/13552541011011695","article-title":"Error analysis of FDM fabricated medical replicas","volume":"16","author":"El-Katatny","year":"2010","journal-title":"Rapid Prototyp J"},{"issue":"3","key":"10.1016\/j.jcms.2019.03.019_bib14","doi-asserted-by":"crossref","first-page":"151","DOI":"10.11607\/jomi.5024","article-title":"An in\u00a0vitro model to evaluate the accuracy of guided implant placement based on the surgeon's experience","volume":"32","author":"Fernandez-Gil","year":"2017","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"8","key":"10.1016\/j.jcms.2019.03.019_bib15","first-page":"796","article-title":"Restoration-driven implant placement with restoration-generated site development","volume":"16","author":"Garber","year":"1995","journal-title":"Compend Contin Educ Dent"},{"issue":"5","key":"10.1016\/j.jcms.2019.03.019_bib16","doi-asserted-by":"crossref","first-page":"1424","DOI":"10.1148\/rg.2017160165","article-title":"Measuring and establishing the accuracy and reproducibility of 3D printed medical models","volume":"37","author":"George","year":"2017","journal-title":"Radiographics"},{"issue":"5","key":"10.1016\/j.jcms.2019.03.019_bib17","first-page":"266","article-title":"Digital image-guided manufacturing of a surgical template","volume":"5","author":"Hu","year":"2012","journal-title":"Chin J Pract Stomatol"},{"issue":"Suppl 6","key":"10.1016\/j.jcms.2019.03.019_bib18","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1111\/j.1600-0501.2012.02545.x","article-title":"Clinical advantages of computer-guided implant placement: a systematic review","volume":"23","author":"Hultin","year":"2012","journal-title":"Clin Oral Implants Res"},{"issue":"3","key":"10.1016\/j.jcms.2019.03.019_bib19","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1177\/1553350610371626","article-title":"Computer-aided maxillofacial surgery: an update","volume":"17","author":"Jayaratne","year":"2010","journal-title":"Surg Innov"},{"issue":"4","key":"10.1016\/j.jcms.2019.03.019_bib20","first-page":"356","article-title":"Implant treatment with fixed prostheses in the edentulous maxilla. Part 2: prosthetic technique and clinical maintenance in two patient cohorts restored between 1986 and 1987 and 15 years later","volume":"24","author":"Jemt","year":"2011","journal-title":"Int J Prosthodont"},{"issue":"Suppl","key":"10.1016\/j.jcms.2019.03.019_bib21","first-page":"92","article-title":"Computer technology applications in surgical implant dentistry: a systematic review","volume":"24","author":"Jung","year":"2009","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"1","key":"10.1016\/j.jcms.2019.03.019_bib22","first-page":"26","article-title":"CAD\/CAM guided surgery in implant dentistry: a brief review","volume":"107","author":"Kattadiyil","year":"2014","journal-title":"Alpha Omegan"},{"issue":"1","key":"10.1016\/j.jcms.2019.03.019_bib23","first-page":"93","article-title":"Tooth-supported surgical guides for guided placement of single-tooth implants","volume":"20","author":"Kurbad","year":"2017","journal-title":"Int J Comput Dent"},{"issue":"1\u20133","key":"10.1016\/j.jcms.2019.03.019_bib24","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1093\/rpd\/ncn154","article-title":"Comparative study of image quality for MSCT and CBCT scanners for dentomaxillofacial radiology applications","volume":"129","author":"Loubele","year":"2008","journal-title":"Radiat Prot Dosim"},{"issue":"22","key":"10.1016\/j.jcms.2019.03.019_bib25","doi-asserted-by":"crossref","first-page":"8493","DOI":"10.1016\/j.biortech.2010.05.092","article-title":"An overview of the recent developments in polylactide (PLA) research","volume":"101","author":"Madhavan","year":"2010","journal-title":"Bioresour Technol"},{"issue":"6","key":"10.1016\/j.jcms.2019.03.019_bib26","doi-asserted-by":"crossref","first-page":"804","DOI":"10.1016\/j.jcms.2017.02.015","article-title":"The impact of the fabrication method on the three-dimensional accuracy of an implant surgery template","volume":"45","author":"Matta","year":"2017","journal-title":"J\u00a0Craniomaxillofac Surg"},{"issue":"4","key":"10.1016\/j.jcms.2019.03.019_bib27","doi-asserted-by":"crossref","first-page":"349","DOI":"10.11607\/ijp.5709","article-title":"Polylactic acid as a material for three-dimensional printing of provisional restorations","volume":"31","author":"Molinero-Mourelle","year":"2018","journal-title":"Int J Prosthodont"},{"issue":"7","key":"10.1016\/j.jcms.2019.03.019_bib28","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1016\/j.jcms.2009.10.023","article-title":"Evaluation of the difference in accuracy between implant placement by virtual planning data and surgical guide templates versus the conventional free-hand method \u2014 a combined in vivo\u2013in vitro technique using cone-beam CT (Part II)","volume":"38","author":"Nickenig","year":"2010","journal-title":"J\u00a0Craniomaxillofac Surg"},{"key":"10.1016\/j.jcms.2019.03.019_bib29","doi-asserted-by":"crossref","first-page":"1125","DOI":"10.1002\/biot.201000135","article-title":"Polylactic acid (PLA): research, development and industrialization","volume":"5","author":"Pang","year":"2010","journal-title":"Biotechnol J"},{"issue":"4","key":"10.1016\/j.jcms.2019.03.019_bib30","doi-asserted-by":"crossref","first-page":"367","DOI":"10.11607\/ijp.5179","article-title":"Reliability of a CAD\/CAM surgical guide for implant placement: an in\u00a0vitro comparison of surgeons' experience levels and implant sites","volume":"30","author":"Park","year":"2017","journal-title":"Int J Prosthodont"},{"issue":"3","key":"10.1016\/j.jcms.2019.03.019_bib31","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1111\/clr.12327","article-title":"In-vitro evaluation of the tolerance of surgical instruments in templates for computer-assisted guided implantology produced by 3-D printing","volume":"26","author":"Schneider","year":"2015","journal-title":"Clin Oral Implants Res"},{"issue":"Suppl","key":"10.1016\/j.jcms.2019.03.019_bib32","doi-asserted-by":"crossref","first-page":"25","DOI":"10.11607\/jomi.2014suppl.g1.2","article-title":"Computer technology applications in surgical implant dentistry: a systematic review","volume":"29","author":"Tahmaseb","year":"2014","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"2","key":"10.1016\/j.jcms.2019.03.019_bib33","first-page":"87","article-title":"In\u00a0vitro comparison of guided versus freehand implant placement: use of a new combined TRIOS surface scanning, Implant Studio, CBCT, and stereolithographic virtually planned and guided technique","volume":"21","author":"Tan","year":"2018","journal-title":"Int J Comput Dent"},{"issue":"3","key":"10.1016\/j.jcms.2019.03.019_bib34","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/S0022-3913(12)60145-0","article-title":"Accuracy of three different types of stereolithographic surgical guide in implant placement: an in\u00a0vitro study","volume":"108","author":"Turbush","year":"2012","journal-title":"J\u00a0Prosthet Dent"},{"issue":"2","key":"10.1016\/j.jcms.2019.03.019_bib35","first-page":"234","article-title":"Accuracy of computer-aided oral implant surgery: a clinical and radiographic study","volume":"24","author":"Valente","year":"2009","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"Suppl 6","key":"10.1016\/j.jcms.2019.03.019_bib36","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1111\/j.1600-0501.2012.02552.x","article-title":"Accuracy of computer-aided implant placement","volume":"23","author":"Van Assche","year":"2012","journal-title":"Clin Oral Implants Res"},{"issue":"1","key":"10.1016\/j.jcms.2019.03.019_bib37","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1111\/prd.12056","article-title":"Different techniques of static\/dynamic guided implant surgery: modalities and indications","volume":"66","author":"Vercruyssen","year":"2014","journal-title":"Periodontol 2000"},{"issue":"3","key":"10.1016\/j.jcms.2019.03.019_bib38","doi-asserted-by":"crossref","first-page":"617","DOI":"10.11607\/jomi.5065","article-title":"The accuracy of implant placement by experienced surgeons: guided vs freehand approach in a simulated plastic model","volume":"32","author":"Vermeulen","year":"2017","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"Suppl 2","key":"10.1016\/j.jcms.2019.03.019_bib39","first-page":"e736","article-title":"Accuracy of image-fusion stereolithographic guides: mapping CT data with three-dimensional optical surface scanning","volume":"17","author":"Widmann","year":"2015","journal-title":"Clin Implant Dent Relat Res"}],"container-title":["Journal of Cranio-Maxillofacial Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1010518218310564?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1010518218310564?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,19]],"date-time":"2025-10-19T14:41:32Z","timestamp":1760884892000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1010518218310564"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8]]},"references-count":39,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2019,8]]}},"alternative-id":["S1010518218310564"],"URL":"https:\/\/doi.org\/10.1016\/j.jcms.2019.03.019","relation":{},"ISSN":["1010-5182"],"issn-type":[{"value":"1010-5182","type":"print"}],"subject":[],"published":{"date-parts":[[2019,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Accuracy of a chairside fused deposition modeling 3D-printed single-tooth surgical template for implant placement: An in\u00a0vitro comparison with a light cured template","name":"articletitle","label":"Article Title"},{"value":"Journal of Cranio-Maxillofacial Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcms.2019.03.019","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}