{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T05:15:13Z","timestamp":1783055713089,"version":"3.54.6"},"reference-count":38,"publisher":"Elsevier BV","issue":"8","license":[{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100007488","name":"Indian Institute of Technology Delhi","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100007488","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100018761","name":"Indo-German Science and Technology Centre","doi-asserted-by":"publisher","award":["2020\/add-bite\/48\/2021-22\/260"],"award-info":[{"award-number":["2020\/add-bite\/48\/2021-22\/260"]}],"id":[{"id":"10.13039\/501100018761","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Cranio-Maxillofacial Surgery"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1016\/j.jcms.2026.104595","type":"journal-article","created":{"date-parts":[[2026,5,20]],"date-time":"2026-05-20T13:05:14Z","timestamp":1779282314000},"page":"104595","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Why detailed modeling matters in the FE-based pre-clinical evaluation of temporomandibular joint implants"],"prefix":"10.1016","volume":"54","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6622-1242","authenticated-orcid":false,"given":"Girish","family":"Chandra","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1185-2060","authenticated-orcid":false,"given":"Rajdeep","family":"Ghosh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vivek","family":"Verma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4589-2527","authenticated-orcid":false,"given":"Kamalpreet","family":"Kaur","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ajoy","family":"Roychoudhury","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sudipto","family":"Mukherjee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anoop","family":"Chawla","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8290-2803","authenticated-orcid":false,"given":"Kaushik","family":"Mukherjee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.jcms.2026.104595_bib1","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1016\/j.jmbbm.2017.01.048","article-title":"A personalized 3D-printed prosthetic joint replacement for the human temporomandibular joint: from implant design to implantation","volume":"69","author":"Ackland","year":"2017","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"10.1016\/j.jcms.2026.104595_bib2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1177\/1687814015593890","article-title":"A comparative study on the customized design of mandibular reconstruction plates using finite element method","volume":"7","author":"Al-Ahmari","year":"2015","journal-title":"Adv. Mech. Eng."},{"key":"10.1016\/j.jcms.2026.104595_bib3","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.jcms.2018.10.022","article-title":"Treatment of end stage temporomandibular joint disorder using a temporomandibular joint total prosthesis: the Slovenian experience","volume":"47","author":"Balon","year":"2019","journal-title":"J. Cranio-Maxillofacial Surg."},{"key":"10.1016\/j.jcms.2026.104595_bib4","doi-asserted-by":"crossref","first-page":"2089","DOI":"10.1002\/jbm.b.35311","article-title":"Design and development of a patient-specific temporomandibular joint implant: probing the influence of bone condition on biomechanical response","volume":"111","author":"Banerjee","year":"2023","journal-title":"J. Biomed. Mater. Res. Part B Appl Biomater"},{"key":"10.1016\/j.jcms.2026.104595_bib5","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/j.jbspin.2007.01.019","article-title":"Evaluation of macrostructural bone biomechanics","volume":"74","author":"Beaupied","year":"2007","journal-title":"Jt. Bone Spine"},{"key":"10.1016\/j.jcms.2026.104595_bib7","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1359\/jbmr.2003.18.4.591","article-title":"How well are bones designed to resist fracture?","volume":"18","author":"Currey","year":"2003","journal-title":"J. Bone Miner. Res."},{"key":"10.1016\/j.jcms.2026.104595_bib8","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1080\/10255842.2010.538385","article-title":"A novel rapid prototyping and finite element method-based development of the patient-specific temporomandibular joint implant","volume":"15","author":"Deshmukh","year":"2012","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"10.1016\/j.jcms.2026.104595_bib9","doi-asserted-by":"crossref","DOI":"10.1016\/j.medengphy.2022.103941","article-title":"Comparative evaluation of a patient-specific customised plate designs and screws for partial mandibular reconstruction","volume":"111","author":"Dutta","year":"2023","journal-title":"Med. Eng. Phys."},{"key":"10.1016\/j.jcms.2026.104595_bib10","doi-asserted-by":"crossref","DOI":"10.3389\/fbioe.2023.1168783","article-title":"Biomechanical evaluation of different strain judging criteria on the prediction precision of cortical bone fracture simulation under compression","volume":"11","author":"Fan","year":"2023","journal-title":"Front. Bioeng. Biotechnol."},{"key":"10.1016\/j.jcms.2026.104595_bib11","article-title":"On the investigation of surface integrity of Ti6Al4V ELI using si-mixed electric discharge machining","volume":"13","author":"Farooq","year":"2020","journal-title":"Materials"},{"key":"10.1016\/j.jcms.2026.104595_bib12","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/j.jor.2019.09.013","article-title":"Stress shielding FE analysis on the temporomandibular joint","volume":"18","author":"Filardi","year":"2020","journal-title":"J. Orthop."},{"key":"10.1016\/j.jcms.2026.104595_bib13","series-title":"Healthcare Research and Related Technologies","first-page":"243","article-title":"Combined influence of material properties of bone and implant on bone growth over macro-textured implant surface BT \u2014 healthcare research and related technologies","author":"Ghosh","year":"2023"},{"key":"10.1016\/j.jcms.2026.104595_bib15","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1177\/09544119251342019","article-title":"Biomechanical evaluation of temporomandibular joint implants and periprosthetic bone under unilateral and bilateral clenching","volume":"239","author":"Ghosh","year":"2025","journal-title":"Proc. Inst. Mech. Eng. Part H J Eng Med"},{"key":"10.1016\/j.jcms.2026.104595_bib16","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.bjoms.2019.10.312","article-title":"Prospective study of five-year outcomes and postoperative complications after total temporomandibular joint replacement with two stock prosthetic systems","volume":"58","author":"Gonzalez-Perez","year":"2020","journal-title":"Br. J. Oral Maxillofac. Surg."},{"key":"10.1016\/j.jcms.2026.104595_bib17","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1002\/ar.22597","article-title":"Comparing the distribution of strains with the distribution of bone tissue in a human mandible: a finite element study","volume":"296","author":"Gr\u00f6ning","year":"2013","journal-title":"Anat. Rec."},{"key":"10.1016\/j.jcms.2026.104595_bib18","first-page":"114","article-title":"Mechanical basis of bone strength: influence of bone material, bone structure and muscle action","volume":"17","author":"Hart","year":"2017","journal-title":"J. Musculoskelet. Neuronal Interact."},{"key":"10.1016\/j.jcms.2026.104595_bib19","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1007\/s10006-016-0573-2","article-title":"Finite element analysis of stress distribution on the mandible and condylar fracture osteosynthesis during various clenching tasks","volume":"20","author":"Hijazi","year":"2016","journal-title":"Oral Maxillofac. Surg."},{"key":"10.1016\/j.jcms.2026.104595_bib20","doi-asserted-by":"crossref","DOI":"10.1186\/s12903-021-01905-5","article-title":"Biomechanical analysis of subcondylar fracture fixation using miniplates at different positions and of different lengths","volume":"21","author":"Huang","year":"2021","journal-title":"BMC Oral Health"},{"key":"10.1016\/j.jcms.2026.104595_bib21","doi-asserted-by":"crossref","first-page":"1194","DOI":"10.1016\/j.jcms.2015.04.016","article-title":"Biomechanical analysis of a temporomandibular joint condylar prosthesis during various clenching tasks","volume":"43","author":"Huang","year":"2015","journal-title":"J. Cranio-Maxillofacial Surg."},{"key":"10.1016\/j.jcms.2026.104595_bib22","doi-asserted-by":"crossref","first-page":"976","DOI":"10.1007\/s10439-009-9659-4","article-title":"Temporomandibular joint: disorders, treatments, and biomechanics","volume":"37","author":"Ingawal\u00e9","year":"2009","journal-title":"Ann. Biomed. Eng."},{"key":"10.1016\/j.jcms.2026.104595_bib23","doi-asserted-by":"crossref","DOI":"10.3390\/ma15124342","article-title":"Design and finite element analysis of patient-specific total temporomandibular joint implants","volume":"15","author":"Ingawale","year":"2022","journal-title":"Materials"},{"key":"10.1016\/j.jcms.2026.104595_bib24","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3389\/fmats.2015.00009","article-title":"Mechanical behavior of osteoporotic bone at sub-lamellar length scales","volume":"2","author":"Jimenez-Palomar","year":"2015","journal-title":"Front. Mater."},{"key":"10.1016\/j.jcms.2026.104595_bib25","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1177\/0022034509357716","article-title":"Finite element analysis of a TMJ implant","volume":"89","author":"Kashi","year":"2010","journal-title":"J. Dent. Res."},{"key":"10.1016\/j.jcms.2026.104595_bib26","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1007\/s12663-016-0903-9","article-title":"Evaluating the effect of minimizing screws on stabilization of symphysis mandibular fracture by 3D finite element analysis","volume":"16","author":"Kharmanda","year":"2017","journal-title":"J. Maxillofac. Oral Surg."},{"key":"10.1016\/j.jcms.2026.104595_bib27","doi-asserted-by":"crossref","first-page":"1152","DOI":"10.1016\/0278-2391(92)90145-P","article-title":"Critical analysis of mandibular reconstruction using AO reconstruction plates","volume":"50","author":"Kim","year":"1992","journal-title":"J. Oral Maxillofac. Surg."},{"key":"10.1016\/j.jcms.2026.104595_bib28","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1002\/ajpa.1330880107","article-title":"Three\u2010dimensional finite element stress analysis of the dentate human mandible","volume":"88","author":"Korioth","year":"1992","journal-title":"Am. J. Phys. Anthropol."},{"key":"10.1016\/j.jcms.2026.104595_bib29","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1016\/j.medengphy.2017.06.015","article-title":"Finite-element design and optimization of a three-dimensional tetrahedral porous titanium scaffold for the reconstruction of mandibular defects","volume":"47","author":"Luo","year":"2017","journal-title":"Med. Eng. Phys."},{"key":"10.1016\/j.jcms.2026.104595_bib30","doi-asserted-by":"crossref","first-page":"1008","DOI":"10.1016\/j.joms.2010.02.019","article-title":"Biomechanical analysis comparing natural and alloplastic temporomandibular joint replacement using a finite element model","volume":"69","author":"Mesnard","year":"2011","journal-title":"J. Oral Maxillofac. Surg."},{"key":"10.1016\/j.jcms.2026.104595_bib31","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1054\/jcms.2002.0297","article-title":"Photoelastic analysis of bone deformation in the region of the mandibular condyle during mastication","volume":"30","author":"Meyer","year":"2002","journal-title":"J. Cranio-Maxillofacial Surg."},{"key":"10.1016\/j.jcms.2026.104595_bib32","doi-asserted-by":"crossref","DOI":"10.3389\/fbioe.2023.1133869","article-title":"Experimental analysis and numerical fatigue life prediction of 3D-printed osteosynthesis plates","volume":"11","author":"Nakhaei","year":"2023","journal-title":"Front. Bioeng. Biotechnol."},{"key":"10.1016\/j.jcms.2026.104595_bib33","article-title":"Implant stability in different implantation stages: analysis of various interface conditions","volume":"19","author":"Niroomand","year":"2020","journal-title":"Inform. Med. Unlocked"},{"key":"10.1016\/j.jcms.2026.104595_bib34","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1016\/j.tripleo.2009.03.051","article-title":"Stability of locking and conventional 2.0-mm miniplate\/screw systems after sagittal split ramus osteotomy: finite element analysis","volume":"108","author":"Oguz","year":"2009","journal-title":"Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod."},{"key":"10.1016\/j.jcms.2026.104595_bib35","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-021-93564-3","article-title":"Biomechanical evaluation of the human mandible after temporomandibular joint replacement under different biting conditions","volume":"11","author":"Pinheiro","year":"2021","journal-title":"Sci. Rep."},{"key":"10.1016\/j.jcms.2026.104595_bib36","doi-asserted-by":"crossref","first-page":"2483","DOI":"10.1016\/j.jbiomech.2008.05.017","article-title":"An accurate estimation of bone density improves the accuracy of subject-specific finite element models","volume":"41","author":"Schileo","year":"2008","journal-title":"J. Biomech."},{"key":"10.1016\/j.jcms.2026.104595_bib37","doi-asserted-by":"crossref","first-page":"266","DOI":"10.5125\/jkaoms.2014.40.6.266","article-title":"Reconstruction plates used in the surgery for mandibular discontinuity defect","volume":"40","author":"Seol","year":"2014","journal-title":"J Korean Assoc Oral Maxillofac Surg"},{"key":"10.1016\/j.jcms.2026.104595_bib38","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1016\/j.jobcr.2020.07.013","article-title":"Finite element analysis of patient-specific TMJ implants to replace bilateral joints with simultaneous correction of facial deformity","volume":"10","author":"Vignesh","year":"2020","journal-title":"J. Oral Biol. Craniofac. Res."},{"key":"10.1016\/j.jcms.2026.104595_bib39","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1016\/j.bjps.2016.10.026","article-title":"Effect of interfragmentary gap on the mechanical behavior of mandibular angle fracture with three fixation designs: a finite element analysis","volume":"70","author":"Wang","year":"2017","journal-title":"J. Plast. Reconstr. Aesthetic Surg."},{"key":"10.1016\/j.jcms.2026.104595_bib40","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.jdsr.2020.03.001","article-title":"Clinical guidelines for total temporomandibular joint replacement","volume":"56","author":"Yoda","year":"2020","journal-title":"Jpn Dent Sci Rev"}],"container-title":["Journal of Cranio-Maxillofacial Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1010518226001526?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1010518226001526?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T04:15:51Z","timestamp":1783052151000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1010518226001526"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":38,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["S1010518226001526"],"URL":"https:\/\/doi.org\/10.1016\/j.jcms.2026.104595","relation":{},"ISSN":["1010-5182"],"issn-type":[{"value":"1010-5182","type":"print"}],"subject":[],"published":{"date-parts":[[2026,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Why detailed modeling matters in the FE-based pre-clinical evaluation of temporomandibular joint implants","name":"articletitle","label":"Article Title"},{"value":"Journal of Cranio-Maxillofacial Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcms.2026.104595","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"104595"}}