{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,21]],"date-time":"2026-02-21T01:53:52Z","timestamp":1771638832908,"version":"3.50.1"},"reference-count":18,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2023,8,1]],"date-time":"2023-08-01T00:00:00Z","timestamp":1690848000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,8,1]],"date-time":"2023-08-01T00:00:00Z","timestamp":1690848000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","journal-cot.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Clinical Orthopaedics and Trauma"],"published-print":{"date-parts":[[2023,8]]},"DOI":"10.1016\/j.jcot.2023.102229","type":"journal-article","created":{"date-parts":[[2023,7,21]],"date-time":"2023-07-21T21:22:27Z","timestamp":1689974547000},"page":"102229","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"special_numbering":"C","title":["Design and fabrication of a custom molded splint for tetraplegics"],"prefix":"10.1016","volume":"43","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6789-4059","authenticated-orcid":false,"given":"Komal","family":"Chhikara","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sweta","family":"Rathee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shakti A.","family":"Goel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jitesh","family":"Manghwani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.jcot.2023.102229_bib1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1179\/1079026813Z.000000000136","article-title":"Spinal cord injury facts and figures at a glance","volume":"36","year":"2013","journal-title":"J.\u00a0Spinal Cord. Med"},{"issue":"10","key":"10.1016\/j.jcot.2023.102229_bib2","doi-asserted-by":"crossref","first-page":"1371","DOI":"10.1089\/neu.2004.21.1371","article-title":"Targeting recovery: priorities of the spinal cord-injured population","volume":"21","author":"Anderson","year":"2004","journal-title":"J\u00a0Neurotrauma"},{"issue":"6","key":"10.1016\/j.jcot.2023.102229_bib3","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1080\/10790268.2017.1329076","article-title":"Assessment and management of acute spinal cord injury: From point of injury to rehabilitation","volume":"40","author":"Hachem","year":"2017","journal-title":"J\u00a0Spinal Cord Med"},{"issue":"6","key":"10.1016\/j.jcot.2023.102229_bib4","doi-asserted-by":"crossref","DOI":"10.1088\/1748-605X\/ac2b7a","article-title":"Mechanical properties of whole-body soft human tissues: a review","volume":"16","author":"Singh","year":"2021","journal-title":"Biomed Mater"},{"issue":"3","key":"10.1016\/j.jcot.2023.102229_bib5","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1016\/S0749-0712(02)00035-5","article-title":"The unoperated hand: the role of passive forces in hand function after tetraplegia","volume":"18","author":"Johanson","year":"2002","journal-title":"Hand Clin"},{"issue":"1","key":"10.1016\/j.jcot.2023.102229_bib6","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12984-018-0391-x","article-title":"Assisting hand function after spinal cord injury with a fabric-based soft robotic glove","volume":"15","author":"Cappello","year":"2018","journal-title":"J\u00a0NeuroEng Rehabil"},{"issue":"1","key":"10.1016\/j.jcot.2023.102229_bib7","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1038\/sj.sc.3101101","article-title":"Hand function of C6 and C7 tetraplegics 1\u201316 years following injury","volume":"39","author":"Harvey","year":"2001","journal-title":"Spinal Cord"},{"issue":"1","key":"10.1016\/j.jcot.2023.102229_bib8","first-page":"45","article-title":"Analysis OF power grip and PINCH grip among health care professionals","volume":"3","author":"M. P","year":"2016","journal-title":"Int J Physiother"},{"key":"10.1016\/j.jcot.2023.102229_bib9","unstructured":"G. J. Snoek, M. J. Ijzerman, F. In`tin`t Groen, T. S. Sto\u20acers, and G. Zilvold, \u201cUse of the NESS Handmaster to Restore Handfunction in Tetraplegia: Clinical Experiences in Ten Patients\u201d."},{"key":"10.1016\/j.jcot.2023.102229_bib10","series-title":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","first-page":"4936","article-title":"Motor-augmented wrist-driven orthosis: flexible grasp assistance for people with spinal cord injury","author":"McPherson","year":"2020"},{"issue":"8","key":"10.1016\/j.jcot.2023.102229_bib11","doi-asserted-by":"crossref","first-page":"807","DOI":"10.1191\/0269215503cr682oa","article-title":"Is hand splinting effective for adults following stroke? A systematic review and methodological critique of published research","volume":"17","author":"Lannin","year":"2003","journal-title":"Clin Rehabil"},{"issue":"18","key":"10.1016\/j.jcot.2023.102229_bib12","doi-asserted-by":"crossref","first-page":"9037","DOI":"10.3390\/app12189037","article-title":"Application of a 3D-printed writing\u2013typing assistive device in patients with cervical spinal cord injury","volume":"12","author":"Kim","year":"2022","journal-title":"Appl Sci"},{"key":"10.1016\/j.jcot.2023.102229_bib13","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1007\/978-1-4613-8087-0_11","article-title":"Orthotics","author":"Bedbrook","year":"1981","journal-title":"Care.Manag.Spinal Cord Inj."},{"issue":"1","key":"10.1016\/j.jcot.2023.102229_bib14","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1080\/10400435.1996.10132268","article-title":"Development of the Quebec user evaluation of satisfaction with assistive technology (QUEST)","volume":"8","author":"Demers","year":"2010","journal-title":"Assist Technol"},{"issue":"1","key":"10.1016\/j.jcot.2023.102229_bib15","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12984-019-0633-6","article-title":"Development of 3D-printed myoelectric hand orthosis for patients with spinal cord injury","volume":"16","author":"Yoo","year":"2019","journal-title":"J\u00a0NeuroEng Rehabil"},{"issue":"21","key":"10.1016\/j.jcot.2023.102229_bib16","doi-asserted-by":"crossref","first-page":"1958","DOI":"10.1089\/neu.2016.4423","article-title":"Functional priorities in persons with spinal cord injury: using discrete choice experiments to determine preferences","volume":"33","author":"Lo","year":"2016","journal-title":"J\u00a0Neurotrauma"},{"issue":"1","key":"10.1016\/j.jcot.2023.102229_bib17","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1038\/sj.sc.3101389","article-title":"Long-term exercise training in persons with spinal cord injury: effects on strength, arm ergometry performance and psychological well-being","volume":"41","author":"Hicks","year":"2002","journal-title":"Spinal Cord"},{"issue":"2","key":"10.1016\/j.jcot.2023.102229_bib18","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/S0004-9514(08)70043-6","article-title":"Short-term progressive resistance exercise may not be effective at increasing wrist strength in people with tetraplegia: a randomised controlled trial","volume":"54","author":"Glinsky","year":"2008","journal-title":"Aust J Physiother"}],"container-title":["Journal of Clinical Orthopaedics and Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0976566223001376?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0976566223001376?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,19]],"date-time":"2025-10-19T08:03:37Z","timestamp":1760861017000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0976566223001376"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8]]},"references-count":18,"alternative-id":["S0976566223001376"],"URL":"https:\/\/doi.org\/10.1016\/j.jcot.2023.102229","relation":{},"ISSN":["0976-5662"],"issn-type":[{"value":"0976-5662","type":"print"}],"subject":[],"published":{"date-parts":[[2023,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Design and fabrication of a custom molded splint for tetraplegics","name":"articletitle","label":"Article Title"},{"value":"Journal of Clinical Orthopaedics and Trauma","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcot.2023.102229","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 Delhi Orthopedic Association. All rights reserved.","name":"copyright","label":"Copyright"}],"article-number":"102229"}}