{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T18:12:42Z","timestamp":1780337562615,"version":"3.54.1"},"reference-count":22,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","journal-cot.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Clinical Orthopaedics and Trauma"],"published-print":{"date-parts":[[2025,7]]},"DOI":"10.1016\/j.jcot.2025.103024","type":"journal-article","created":{"date-parts":[[2025,4,19]],"date-time":"2025-04-19T15:48:17Z","timestamp":1745077697000},"page":"103024","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"special_numbering":"C","title":["Finite element analysis of sliding vs static configuration of partial threaded cannulated compression screws for Pauwels type III fracture neck of femur"],"prefix":"10.1016","volume":"66","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5715-1809","authenticated-orcid":false,"given":"Amit","family":"Kumar","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Somesh","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1501-4889","authenticated-orcid":false,"given":"Ajeet","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2164-0029","authenticated-orcid":false,"given":"Kumar","family":"Keshav","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anurag","family":"Baghel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pulak","family":"Sharma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"Suppl 1","key":"10.1016\/j.jcot.2025.103024_bib1","doi-asserted-by":"crossref","first-page":"S27","DOI":"10.1097\/BOT.0000000000001365","article-title":"Biomechanics of femoral neck fractures and implications for fixation","volume":"33","author":"Augat","year":"2019","journal-title":"J Orthop Trauma"},{"issue":"1","key":"10.1016\/j.jcot.2025.103024_bib2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.4055\/cios.2019.11.1.1","article-title":"Biomechanical evaluation of internal fixation of pauwels type III femoral neck fractures: a systematic review of various fixation methods","volume":"11","author":"Cha","year":"2019","journal-title":"Clin Orthop Surg"},{"issue":"2","key":"10.1016\/j.jcot.2025.103024_bib3","first-page":"490","article-title":"Results of internal fixation of Pauwels type-3 vertical femoral neck fractures","volume":"91","author":"Parker","year":"2009","journal-title":"J Bone Joint Surg Am"},{"issue":"10","key":"10.1016\/j.jcot.2025.103024_bib4","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1097\/BOT.0000000000001551","article-title":"Femoral neck shortening after hip fracture fixation is associated with inferior hip function: results from the FAITH Trial","volume":"33","author":"Felton","year":"2019","journal-title":"J Orthop Trauma"},{"issue":"6","key":"10.1016\/j.jcot.2025.103024_bib5","doi-asserted-by":"crossref","first-page":"673","DOI":"10.3944\/AOTT.2014.14.0088","article-title":"Influence of number and orientation of screws on stability in the internal fixation of unstable femoral neck fractures","volume":"48","author":"Gumustas","year":"2014","journal-title":"Acta Orthop Traumatol Turc"},{"issue":"11","key":"10.1016\/j.jcot.2025.103024_bib6","doi-asserted-by":"crossref","first-page":"3408","DOI":"10.1016\/j.injury.2021.07.014","article-title":"Long-term differences in clinical prognosis between crossed- and parallel-cannulated screw fixation in vertical femoral neck fractures of non-geriatric patients","volume":"52","author":"Jiang","year":"2021","journal-title":"Injury"},{"issue":"3","key":"10.1016\/j.jcot.2025.103024_bib7","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1016\/j.jcot.2017.07.003","article-title":"Non-parallel screw fixation for femoral neck fractures in young adults","volume":"8","author":"Galal","year":"2017","journal-title":"J Clin Orthop Trauma"},{"key":"10.1016\/j.jcot.2025.103024_bib8","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/j.jor.2022.07.012","article-title":"Biplane double supported screw fixation for femoral neck fracture in young adults: a prospective cohort study","volume":"33","author":"Sami","year":"2022","journal-title":"J Orthop"},{"issue":"6","key":"10.1016\/j.jcot.2025.103024_bib9","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1007\/s00402-017-2689-8","article-title":"Femoral neck fracture osteosynthesis by the biplane double-supported screw fixation method (BDSF) reduces the risk of fixation failure: clinical outcomes in 207 patients","volume":"137","author":"Filipov","year":"2017","journal-title":"Arch Orthop Trauma Surg"},{"issue":"3","key":"10.1016\/j.jcot.2025.103024_bib10","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1007\/s12178-012-9127-x","article-title":"Contemporary management of femoral neck fractures: the young and the old","volume":"5","author":"Forsh","year":"2012","journal-title":"Curr Rev Musculoskelet Med"},{"issue":"1","key":"10.1016\/j.jcot.2025.103024_bib11","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1186\/s13018-021-02619-8","article-title":"Enhanced interfragmentary stability and improved clinical prognosis with use of the off-axis screw technique to treat vertical femoral neck fractures in nongeriatric patients","volume":"16","author":"Jiang","year":"2021","journal-title":"J Orthop Surg Res"},{"issue":"2","key":"10.1016\/j.jcot.2025.103024_bib12","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1016\/j.injury.2014.11.013","article-title":"Unique stability of femoral neck fractures treated with the novel biplane double-supported screw fixation method: a biomechanical cadaver study","volume":"46","author":"Filipov","year":"2015","journal-title":"Injury"},{"issue":"1","key":"10.1016\/j.jcot.2025.103024_bib13","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1186\/s13018-019-1148-3","article-title":"Comparison of three different internal fixation implants in treatment of femoral neck fracture-a finite element analysis","volume":"14","author":"Li","year":"2019","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"10.1016\/j.jcot.2025.103024_bib14","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1186\/s12938-023-01083-1","article-title":"Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis","volume":"22","author":"Huang","year":"2023","journal-title":"Biomed Eng Online"},{"issue":"1","key":"10.1016\/j.jcot.2025.103024_bib15","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1186\/s12891-020-03853-7","article-title":"Influence of the proximal screws of buttress plates on the stability of vertical femoral neck fractures: a finite element analysis","volume":"21","author":"Zhan","year":"2020","journal-title":"BMC Muscoskelet Disord"},{"key":"10.1016\/j.jcot.2025.103024_bib16","doi-asserted-by":"crossref","DOI":"10.1016\/j.cmpb.2021.106409","article-title":"Biomechanical study of two alternative methods for the treatment of vertical femoral neck fractures - a finite element analysis","volume":"211","author":"Xia","year":"2021","journal-title":"Comput Methods Progr Biomed"},{"issue":"1","key":"10.1016\/j.jcot.2025.103024_bib17","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1016\/j.rbo.2017.01.007","article-title":"Treatment of displaced femoral neck fractures in young patients with DHS and its association to osteonecrosis","volume":"53","author":"Schwartsmann","year":"2017","journal-title":"Rev Bras Ortop"},{"issue":"Suppl 1","key":"10.1016\/j.jcot.2025.103024_bib18","doi-asserted-by":"crossref","first-page":"S27","DOI":"10.1097\/BOT.0000000000001365","article-title":"Biomechanics of femoral neck fractures and implications for fixation","volume":"33","author":"Augat","year":"2019","journal-title":"J Orthop Trauma"},{"issue":"7","key":"10.1016\/j.jcot.2025.103024_bib19","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1002\/jor.22617","article-title":"Disadvantages of interfragmentary shear on fracture healing--mechanical insights through numerical simulation","volume":"32","author":"Steiner","year":"2014","journal-title":"J Orthop Res"},{"issue":"3","key":"10.1016\/j.jcot.2025.103024_bib20","doi-asserted-by":"crossref","DOI":"10.1097\/OI9.0000000000000138","article-title":"A systematic review of the use of titanium versus stainless steel implants for fracture fixation","volume":"4","author":"Barber","year":"2021","journal-title":"OTA Int"},{"issue":"8","key":"10.1016\/j.jcot.2025.103024_bib21","doi-asserted-by":"crossref","first-page":"1654","DOI":"10.2106\/JBJS.G.01353","article-title":"Results of internal fixation of Pauwels type-3 vertical femoral neck fractures","volume":"90","author":"Liporace","year":"2008","journal-title":"J Bone Joint Surg Am"},{"issue":"4","key":"10.1016\/j.jcot.2025.103024_bib22","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1111\/os.12503","article-title":"Comparison of transverse cancellous lag screw and ordinary cannulated screw fixations in treatment of vertical femoral neck fractures","volume":"11","author":"Dong","year":"2019","journal-title":"Orthop Surg"}],"container-title":["Journal of Clinical Orthopaedics and Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0976566225001213?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0976566225001213?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,6,23]],"date-time":"2025-06-23T20:15:31Z","timestamp":1750709731000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0976566225001213"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7]]},"references-count":22,"alternative-id":["S0976566225001213"],"URL":"https:\/\/doi.org\/10.1016\/j.jcot.2025.103024","relation":{},"ISSN":["0976-5662"],"issn-type":[{"value":"0976-5662","type":"print"}],"subject":[],"published":{"date-parts":[[2025,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Finite element analysis of sliding vs static configuration of partial threaded cannulated compression screws for Pauwels type III fracture neck of femur","name":"articletitle","label":"Article Title"},{"value":"Journal of Clinical Orthopaedics and Trauma","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.jcot.2025.103024","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 Delhi Orthopedic Association. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"103024"}}